RGF PTAC, ETAC Installation Instructions Manual

Page 1
Cleaner, Fresher Air in 24 Hours
New Advanced Environmental Air Treatment System
For PTAC & ETAC Units
NOTE: Please take time to read the attached assembly instructions.
All instructions and precautions should be adhered to while
operating this system.
Manufactured in the USA by RGF Environmental Group, Inc.
RGF Environmental Group, Inc.
PTAC 9-2012
Page 2
Page 3
The PTAC PHI Unit by RGF
The PHI line of products are designed to help eliminate sick building syndrome risks by reducing odors, air pollutants, bacteria and cold and virus causing germs through the patented Photohydroionization
®
(PHI) process. The PHI Cell easily mounts into existing PTAC air conditioning, heating and heat pump units. When the PTAC system is in operation, the PHI Cell uses an Advanced Oxidation Process to reduce airborne contaminants.
Quad-metallic coating
Proprietary UVX Long
life lamp
PHI Cell Features
Figure 1
Figure 2
Incoming air containing bacteria,
mold, smoke, virus and VOCs
Typical Installation
Purified air distributed to
conditioned space
Air Knight PTAC unit
Page 4
PTAC PHI Unit
INSTALLATION INSTRUCTIONS
Your kit contains the following:
• PTAC unit with high voltage 208-265V ballast and 3’ leads
• Four (4) mounting screws
• Four (4) wire nuts
• Two (2) wire tap splice connectors
• Instruction manual
NOTE: BE SURE PTAC UNIT IS UNPLUGGED AND POWER IS
DISCONNECTED BEFORE PROCEEDING WITH INSTALLATION.
INSTALLATION INSTRUCTIONS:
1. Remove plastic housing from PTAC unit by carefully lifting tabs off metal
frame.
CAUTION: NEVER LOOK DIRECTLY AT AN ILLUMINATED PHI CELL. THIS DEVICE PRODUCES GERMICIDAL UV LIGHT AND WILL CAUSE
DAMAGE TO EYES
Figure 3
Guardian Air REME HVAC Cell REME or Re-
flective Electro Magnetic Energy utilizes an
electromagnetic energy cell to create ionized
hydro peroxides™, a friendly oxidizer plasma
made from oxygen and humidity. This air purify-
ing plasma is propelled into the HVAC duct or
plenum by a silent plasma propulsion module
that has no moving parts, yet propels the
plasma at 2 cfm. This provides for fan or blower-
less operation on a 24-hour basis. The purifying plasma will be propelled
through the ducts whether the fan or blower is on or not. 24 volt installation
lets the REME run 24/7 without wiring to the fan/blower circuit. The oxidizer
plasma transfers the electrical charge (positively and negatively charged ions)
from the hydro peroxides to suspended (airborne) particles in the occupied
space causing them to bond together. This makes them too heavy to float en-
abling them to be drawn back to the filter. This is an excellent solution for in-
divuals that suffer from dust and dander allergies.
RGF’s Guardian Air PHI is designed to elimi-
nate sick building syndrome risks by reducing
odors, air pollutants, VOCs (chemical odors),
smoke, mold, bacteria and viruses*. The HVAC-
PHI Cells are easily mounted into air condition-
ing and heating systems air ducts where most
sick building problems start. When the HVAC
system is in operation the HVAC-PHI Cell cre-
ates an Advanced Oxidation Process consisting of: Hydro-peroxides, super
oxide ions and hydroxide ions. All are friendly oxidizers that revert back to
oxygen and hydrogen after the oxidation of the pollutant.
Additional RGF Products
In Duct Microbe, VOC and Allergen Solutions
Page 5
Figure 5
Figure 4
2. Remove metal screen by removing the 6 screws. (Refer to figure 4)
3. Attach unit to screen using the 4 screws. (Refer to figure 5)
LIMITED WARRANTY
This warranty supersedes and replaces any warranty statements made orally by the Sales Person, Distributor, or Dealer, or contained in the written instruc­tions or other brochures or informational documents related to this product.
Manufacturer warrants the new PTAC PHI equipment to be free from defects in material and workmanship under normal use and service when operated and maintained in strict accordance with manufacturer’s instructions for a period of twelve (12) months parts only. Shipping not included.)
Manufacturer’s obligation under this warranty is limited to repairing or replacing any part found to its satisfaction to be so defective. The manufacturer at its dis­cretion may replace / exchange the defective unit up to 90 days from the date of purchase. Hereafter it will need to be returned under a Returned Materials Authorization (RMA) for review and or repair (if found defective). This warranty does not cover parts damaged by decomposition from chemical action or wear caused by abrasive materials, nor does it cover damage resulting from misuse, abuse, or any other than its intended use, accident, neglect, or from improper operation, maintenance, installation, modification or adjustments.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HEREOF.
To obtain warranty service and return authorization number, contact your contractor or supplier.
Model number: UNV-PTAC
Replacement cell part number: PHIC-5GA
Hg- LAMP CONTAINS MERCURY Manage in accord with disposal laws.
See: www.lamprecycle.org
Page 6
Electrical Connection:
8. Mount ballast to inside of electrical enclosure cover by first
removing cover
Figure 10
9. Using double stick tape mount ballast to inside of electrical
enclosure cover.
Figure 11
LIMITED WARRANTY COMMON QUESTIONS
How long is the warranty?
•For one (1) year from initial start up.
Are there any parts not covered by this warranty (that the manufaturer will not repair or replace)?
•Yes. Parts damaged by decomposition from chemical action, hu­midity, moisture, or wear caused by abrasive materials. It does not cover damage resulting from misuse, abuse, or any other use other than its intended use. This warranty does not cover acci- dent, neglect, or from improper operation, maintenance, installa­tion, modification or adjustments.
•Parts not made by Manufacturer. However, your supplier will process the claim with the other manufacturer.
Steps to take when you have determined that your equipment is mal­functioning within the warranty period.
•Call your contractor or distributor and notify them of the problem or malfunction. (It may be a simple problem or oversight with a simple solution.)
•If it is determined that a part is malfunctioning due to a defect, ship
unit to your supplier or call supplier for other means of
return. An Equipment Warranty Form should be completed and
included.
•Your supplier will repair or exchange the defective unit with a work­ing replacement.
Things I should do to avoid problems or injuries when running my PTAC PHI Equipment.
•Thoroughly read and understand all Operating Instructions, Warnings and Precautions before commencing application.
•Place unit in a dry area when possible.
Page 7
• Using wire strippers remove 1/2” of insulation from ends of ballast wires and cell wires.
• Using supplied wire nuts attach wires from cell to wires from ballast. Blue to blue and red to red.
Figure 12
Figure 13
• Replace screen.
• Replace cover.
• Reconnect power and turn on unit to verify PHI unit operation. (Should notice faint blue glow from outlet vent area.)
• Replace enclosure cover
• Ensure PHI power cord is routed as shown (see figure 18)
• Ensure wire does not interfere with squirrel cage operation.
Figure 18
Page 8
• Locate input power cord terminal (directly below capacitor) and connect black wire (line) using supplied wire tap splice connector.
• To use the wire tap splice terminal first place around wire and press firmly.
• Now remove 1/2” of insulation from ballast power wire and press into holes on wire tap splice. White to white (neutral) black to black (line).
• Locate terminal N1 and connect white wire (neutral) using supplied wire tap splice connector.
Figure 14
Figure 15
Capacitor
Figure 16
Figure 17