RFS OR2-SBLP2-21F Technical Handbook

PICO REPEATERS
OR2-SBLP2 SERIES
TECHNICAL HANDBOOK
Radio Frequency Systems
2
INDEX
1. System Overview ........................................................................................................ 5
2. System Network Configuration................................................................................. 6
2.1. Service for Network........................................................................................... 6
2.2. NMS Network .................................................................................................... 7
3. System Configuration & Specification ..................................................................... 8
3.1. System Configuration........................................................................................ 8
WCDMA System configuration....................................................................... 8
3.2 Detail Frequency Information............................................................................. 8
3.3 OR2-SBLP2-21F General Performance Specification...................................... 8
3.4 OR2-SBLP2-21F Fading Performance Specification........................................ 9
3.5 System Configuration........................................................................................... 9
3.6 Environmental Specification ............................................................................... 9
3.7 Mechanical Specification ..................................................................................... 9
4. Housing...................................................................................................................... 10
4.1 Composition ........................................................................................................ 10
System Exterior .............................................................................................. 10
External Connectors ....................................................................................... 11
5. Module Specification................................................................................................ 13
5.1 Internal Antenna ................................................................................................ 13
Donor Antenna Specification ......................................................................... 13
Service Antenna Specification........................................................................ 13
5.2 External Antenna................................................................................................ 14
5.3 Power Adaptor.................................................................................................... 14
6. LCD Display Configuration..................................................................................... 15
6.1 LCD display Configuration ............................................................................... 15
6.2 Alarm and Status Display.................................................................................. 15
6.3 Downlink Input/ Output Power Display........................................................... 16
6.4 Control................................................................................................................. 16
7. Installation Guide..................................................................................................... 17
7.1. Accessory.......................................................................................................... 17
7.3. FA Control Guide............................................................................................ 17
Radio Frequency Systems
3
List of Figures
[Figure - 1] System Network Configuration..................................................................... 6
[Figure - 2] NMS Network 7
[Figure - 3] Front, Side View 10
[Figure - 4] Unit 11
[Figure - 5] External Connectors 11
Radio Frequency Systems
4
List of Tables
[Table - 1] RF System configuration................................................................................ 8
[Table - 2] Detail Frequency Information 8
[Table - 3] OR2-SBLP2-21F General Performance Specification 8
[Table - 4] OR2-SBLP2-21F Fading Performance Specification 9
[Table - 5] System Configuration 9
[Table - 6] Environmental Specification 9
[Table - 6] Mechanical Specification 12
[Table - 8] Service Antenna Specification 13
[Table - 9] Power Adaptor Specification 14
[Table - 10] LCD Segment Status Display 15
[Table - 11] LCD DownLink Power Scale Display 16
[Table - 12] Tact Switch 16
Radio Frequency Systems
5
1. System Overview
OR2-SBLP2-21F is used ‘For Mobile Operator use Only’.
OR2-SBLP2-21F is a digital repeater that provides optimized service with ICS (Interference Cancellation System) to make the most efficient way to enhance WCDMA network.
OR2-SBLP2-21F consists of the same components as normal RF repeater except DSP (Digital Signal Processing) part and it can overcome oscillation problem caused by lack of the isolation level between donor and coverage antennas.
OR2-SBLP2-21F can automatically compensate rapidly-changing input signals including echo feedback signals caused by multi-path environment and it has various advantages in terms of the operation and maintenance purposes.
OR2-SBLP2-21F consists of ICM (Interference Cancellation Module) that cancels feedback signals, RF signal amplifier, MCU (Main Control Unit), and modem (optional) to operate with NMS (Network Management System).
Radio Frequency Systems
6
2. System Network Configuration
2.1. Service for Network
OR2-SBLP2-21F is the advanced antenna-embedded ICS repeater for indoor coverage enhancement. This repeater adopted automatic setup feature with Plug & Play to save time and installation cost. Network layout with OR2-SBLP2-21F is as follows.
[Figure - 1] System Network Configuration
OR2-SBLP2-21F receives input signals through donor antenna from Node-B for DL and receives input signals through service antenna from a cell phone. They are all air-coupled.
OR2-SBLP2-21F system consists of ICM (Interference Cancellation Module) that cancels feedback signals between donor and service antennas, power supply, digital board including controller, RF board for Tx/Rx amplifier and filtering, and modem board to connect with NMS server.
OR2-SBLP2-21F receives Node-B RF signals as input via donor antenna and sends them to ICS of digital board and Down Link amplifier where they are amplified to a proper level to the service antenna. Also it receives mobile phone RF signals as input via service antenna and sends them to ICS and Up Link amplifier to the donor antenna.
ICS is to cancel echo feedback signals between donor antenna and service antenna. It consists of RF and digital parts.
Radio Frequency Systems
7
2.2. NMS Network
OR2-SBLP2-21F can be operated with its own RMS (Remote Monitoring System) or connected with the existing remote management system if the operator provides the protocols. The Connection between Remote management system and OR2-SBLP2-21F follows the standard of network operators.
[Figure - 2] NMS Network
Radio Frequency Systems
8
3. System Configuration & Specification
3.1. System Configuration
WCDMA System configuration
Item Specification Remark
Frequency Range
DL:2110.1MHz ~ 2125.1MHz UL:1920.1MHz ~ 1935.1MHz
Filter
Donor Antenna (Node-B) : Duplexer
Service Antenna (Mobile) : Duplexer
Ripple 3dB p-p/FA Ripple , ±1.5dB/Each FA Output
Down Link +13dBm/Total
Max Output
Up Link +13dBm/FA
Down Link -57dBm ~ -33dBm/Total
Input level
Up Link -47dBm/FA
Down Link 46dB~70dB 1dB Step AGC
Range
Up Link 46dB~70dB 1dB Step
System Delay < 10us
Waveform Quality EVM 12.5%
Peak Code Domain Error < -35dB
Frequency Stability < 0.01ppm
VSWR < 2.0:1
Noise Figure < 9dB
Up Link Only
@Full Range
Out-band ACLR
44.2dBc (@ Fc±5MHz)
49.2dBc (@ Fc±10MHz)
[Table - 1] RF System configuration
3.2 Detail Frequency Information
Parameter
Down Link
UARFCN DL
Up Link UARFCN UL
Center Frequency 2112.6MHz
2117.6MHz
2122.6MHz
10563 10588 10613
1922.6MHz
1927.6MHz
1932.6 MHz
9613 9638 9663
[Table - 2] Detail Frequency Information
3.3 OR2-SBLP2-21F General Performance Specification
Item Condition Specification Remark
Cancellation Window Length DL, UL 3 us
Gain Tracking Time Target Gain ±1dB < 10 Sec
Isolation Sensing Range
-10dB < Gain < 10dB (-5dB < Gain < 5dB)
Accuracy ±3
(Accuracy ±1)
[Table - 3] OR2-SBLP2-21F General Performance Specification
Radio Frequency Systems
9
3.4 OR2-SBLP2-21F Fading Performance Specification
Gain
Feedback Condition
(Multi-path 10)
Specification Remark
G = I + 10dB Static Static
EVM : 12.5%
Gain Variation : < ±2dB
No Fading
G = I 3Hz 3Hz
EVM : 12.5%
Gain Variation : < 2dB
General Operating
[Table - 4] OR2-SBLP2-21F Fading Performance Specification
3.5 System Configuration
Item Specification
Additional Features
(Attachment in details)
AGC(Automatic Gain Control) & Boundary AGC
Total Power Limit
Real time Isolation monitoring.
Feedback cancellation (Interference Cancellation)
DL over input power, Alarm and Shutdown
Automatic Setup & Manual Setup
LCD Display Status display ( Input, Isolation, Output)
Power Supply
DC
- Input Voltage : 5.1VDC ~ 5.5VDC
RF Connector SMBL Type Female
[Table - 5] System Configuration
3.6 Environmental Specification
Item Specification Remark
Operating
Temperature
-10°C ~ +50C
T 20°C (Chamber inner
temp. Vs. Repeater inner
temp.)
Operating Humidity 5% ~ 95%
Housing IP IP 34
Cold start 20°C
[Table - 6] Environmental Specification
3.7 Mechanical Specification
Characteristic Specification
Size 117mm(W) X 167mm(H) X 55mm(D) Weight 1.15Kg( Including Stand ) Power Consumption 18W
[Table - 7] Mechanical Specification
Radio Frequency Systems
10
4. Housing
4.1 Composition
System Exterior
[Figure - 3] Front, Side View
Donor Service
- internal antenna –
Radio Frequency Systems
11
A Type B Type
- Donor anntena option -
[Figure - 4] Unit
External Connectors
[Figure - 5] External Connectors
Radio Frequency Systems
12
Item Specification
Size 117mm(W) X 167mm(H) X 55mm(D)(Without Stand) Material Aluminum for rust protection Cooling Natural Convection with Heat Sink
Lock Bolt
Environmental
Condition
1. Indoor Type
2. T: below 20°
(T: Highest temperature in Chamber Vs. Highest
temperature of repeater inner part)
3.Vibration : 1.5G, 10~100Hz, 0.1oct/min, XYZ
[Table - 6] Mechanical Specification
Radio Frequency Systems
13
5. Module Specification
5.1 Internal Antenna
Donor Antenna Specification
Specification
Micro-strip Patch
Remark
1920MHz ~ 1980MHz Up link
Frequency Range
2110MHz ~ 2170MHz Down link
Polarization Vertical
Gain > 7dBi
F/B Ratio 15dB
Horizontal : 60°±10°
Beam width
Vertical : 60°±10°
V. S. W. R < 2.0 : 1
Power Capability 5 Watt
Impedance 50 ohms
Isolation < 70dB * anechoic
Dimension 99.5mm(W)×99.5mm(H)×12mm(D)
Electrical
Characteristic
Connector type SMBL Male
[Table - 7] Donor Antenna Specification
Service Antenna Specification
Specification
Micro-strip Patch
Remark
1920MHz ~ 1980MHz Up link Frequency Range 2110MHz ~ 2170MHz Down link
Polarization Horizontal
Gain > 7dBi
F/B Ratio 15dB
Horizontal : 60°±10° Beam width
Vertical : 60°±10°
V. S. W. R < 2.0 : 1
Power Capability
5 Watt
Impedance 50 ohms
Isolation < 70dB * anechoic
Dimension
99.5mm(W)×99.5mm(H)×12mm(D)
Electrical
Characteristic
Connector type SMBL Male
[Table - 8] Service Antenna Specification
Radio Frequency Systems
14
5.2 External Antenna
Specification
Micro-strip Patch
Remark
1920MHz ~ 1980MHz Up link
Frequency Range
2110MHz ~ 2170MHz Down link
Gain > 7dBi
F/B Ratio 15dB
Horizontal : 60°±10°
Beam width
Vertical : 60°±10°
V. S. W. R < 2.0 : 1
Power Capability 5 Watt
Impedance 50 ohms
Electrical
Characteristic
Connector type SMA Female
5.3 Power Adaptor
Parameter Specification
Rated input voltage AC100 ~ 240Vac Operating Voltage range AC 90 ~ 264Vac Rated input frequency 50/60Hz +/- 3Hz Rated input current 1.2A max. at 90 VAC input Inrush Current 60A pk @ Cold Start Nominal dc output voltage + 5.3V ±5% Minimum load current 0.05A Rating load current 4.7 A Line regulation ±2% Load regulation ±5% Configuration IEC320- C14 Inlet, Desk Top Type Switching efficiency 80% min.
Turn-on time
2.0sec max @ 115VAC/60Hz
2.0sec max @ 230VAC/60Hz Short circuit Protection 10minute max@264VAC/60Hz Operating temperature -10°~+50°(Humidity 10%~90%) Storage temperature -20°~+80°(Humidity 10%~90%)
[Table - 9] Power Adaptor Specification
Radio Frequency Systems
15
6. LCD Display Configuration
6.1 LCD display Configuration
Function Details Remark
Display LCD Indicator (Alarm, Status, Control) Control Tact SW#1, Tact SW#2 Up/Down Compatible
Back Light Blue Back Light For 3 Minute
6.2 Alarm and Status Display
Section Segment Details Remark
Input Power Scale Status
POWER
Output Power Scale Status
FA
FA (Frequency Allocation) Status / Control
PLL(Phase Locked Loop) Alarm
UL Over Output Power
Shutdown
Alarm
DL Over Output Power
Shutdown
Alarm
DL Over Input Power
Shutdown
Alarm
Up Link Isolation Lack Alarm
ALARM
Down Link Isolation Lack Alarm
[Table - 10] LCD Segment Status display
Radio Frequency Systems
16
6.3 Downlink Input/ Output Power Display
Input Power Range Scale Output Power Range
Scale
-85dBm 0 Segment ~-10dBm 0 Segment
-84 ~ -76dBm 1 Segment -9 ~-4dBm 1 Segment
-75 ~ -67dBm 2 Segment -3 ~ +2dBm 2 Segment
-66 ~ -58dBm 3 Segment +3 ~ +8dBm 3 Segment
-57 ~ -33dBm 4 Segment +9dBm~ 4 Segment
[Table - 11] LCD DownLink Power Scale Display
6.4 Control
No. Tact S/W#1 Tact S/W#2 Function
1 Release
(No Condition)
Push (More than 3 Sec)
Top and Bottom Reversal
2 Push
(More than 3 Sec)
Push (More than 3 Sec)
1. Enter FA Setup Mode(FA Flick)
2. Exit FA Setup Mode
3 Push
(Tick)
Release (No Condition)
Move to Right FA (in FA Setup Mode)
4 Release
(No Condition)
Push (Tick)
Move to Left FA (in FA Setup Mode)
5 Push
(More than 2 Sec)
Release (No Condition)
Set/Clear Correspond to FA
6 Release
(No Condition)
Push (More than 2 Sec)
Set/Clear Correspond to FA
[Table - 12] Tact Switch
Radio Frequency Systems
17
7. Installation Guide
7.1. Accessory
Pico Repeater 1EA
AC/DC Adaptor 1EA
Donor Antenna 1EA (Inside Repeater)
Service Antenna 1EA (Inside Repeater)
External Antenna 1EA
SMA To SMBL Adaptor Cable
7.2. Installation Chart
Connect the Power Adaptor to repeater power port before installation
After all set-up, power on the front side toward the service area according
to the installation place
Put the maximum DL Signal input level Area for repeater maximum Output
Check Isolation Alarm or an ETC alarm
7.3. FA Control Guide
Push #1 and #2 for 3sec to enter FA Setup Mode
If the shape which shows FA1 to FA3( )is blinking, you can start FA Setup
Push #1 or #2 shortly to select FA you want to use
After selecting FA, push #1 or #2 for 2sec to change setting status (If
it’s turned on/off, it will be turned off/on)
To finish Setup Mode, push #1 and #2 for 3sec
Loading...