RF Hunter HF FOG130 Service Manual

F.O.G. CADDY
FILTRATOR
BATTERY
SERVICE INSTRUCTIONS
CAUTION: ALWAYS UNPLUG UNIT WHEN WORKING ON ELECTRICAL ITEMS.
PROBLEM PROBABLE CAUSE CORRECTIVE ACTION
1. Motor does not work A) Battery not charged 1. Charge Battery B) Blown Fuse 2. Replace Fuse:
Unscrew fuse holder cap located underneath the power unit. Remover the bad fuse and replace with the spare 15 AMP fuse provided with the unit. Replace the fuse holder cap by screwing the cap into place.
C) Defective Switch 4. Replace Switch
D) Defective Motor 5. Replace Motor
E) Defective Battery 6. Replace Battery
NOTE: To replace any component inside the Power Unit other than the fuse requires the removal of the Power Unit Housing Cover.
PROBLEM
1. Lack of Suction or Discharge A) Clogged Screen
C) Loose Fittings
D) Cracked and /or swollen Hose 4. Replace Hose
PROBABLE CAUSE CORRECTIVE ACTION
1. If this happens during operation, reverse the flow of the oil.
B) Hardened oil in pump or elsewhere
2. Place unit near heat source to loosen the hardened oil.
3. Check tightness of pump nipple/sockets and screen.
113 Crosby Road, Ste. #9, Dover, NH 03820-4370
Tel: (603) 742-9565 Fax: (603) 742-9608 (800) 332-9565
E-mail:
sales@rfhunter.com
Visit our website at
www.rfhunter.com
FOGSIB 4-06