INSTALLATION
OPERATING
MAINTENANCE
O’Fallon, MO USA 63368 - Tel.: 1 800 695-1901
©2014 Reznor, LLC. All rights reserved. All other trademarks are
the property of their respective organizations.
Reznor LLC
www.ReznorHVAC.com
INSTRUCTIONS
ECR Model (2 kW to 5 kW)
WARNING
When using electrical appliances, basic precautions should
always be taken to reduce the risk of fi re, electrical shock
and injury, including the following:
Read carefully these instructions before installation, operation of
the heater. Failure to adhere to the instructions could result in fi re,
electric shock, serious personal injury, and death or property damage.
Review frequently for continuing safe operation and instruction of
future users, if necessary.
IMPORTANT
INSTRUCTIONS
INSTRUCTIONS
- The installation must be executed by a qualifi ed technician.
- Must be installed solidly. This heater could weight up to 31 lb
(14 kg).
- The motor is thermally protected.
- All wiring must be in accordance with National and local
Electrical Codes.
- Heater must be grounded as a precaution against possible shock.
- To avoid possible electrical shock, disconnect all power at the
main panel prior to wiring.
- Verify the power supply voltage coming to the heater matches the
heater nameplate rating before energizing heater.
- When installed, heater must be electrically grounded in
accordance with the National Electrical Code.
CAUTION
- High temperature, risk of fi re, keep electrical cords, drapery,
furnishings, and other combustibles at least 36 in. (915 mm) from
the front of the heater. To reduce the risk of fi re, do not store or
use gasoline or other fl ammable vapors and liquids in the vicinity
of the heater.
- Ceiling installation only.
- Use copper wire only.
STANDARD CEILING MOUNTING (Fig. 1)
1. Never install the air-forced diffuser at less than 8 ft. (250 cm)
from the fl oor and 12 in. (30 cm) from adjacent walls.
2. Provide an opening in the ceiling of
23 X 23 X 6 3/16 in. (580 X 580 X 160 mm).
3. Convey the wires of power supply to the opening provided.
4. Remove the appropriate knock-out from the recess box
for the electrical supply.
5. Attach fi rmly the heater using provided screws.
6. Connect the heater leads to the supply leads according
to the national and local codes. See wiring diagram.
7. Install the front cover using provided screws (4).
INSTRUCTIONS
The heater must be properly installed before it is used.
START UP
- Turn the power on at the circuit breaker panel.
- Electronic thermostat: be sure to set it on the fan mode.
- Built-in tamperproof thermostat: the setting can be done with a
small slotted screwdriver.
- On a call for heat from either remote thermostat or unit mounted
thermostat, the elements and fan will be energized.
- When the thermostat is satisfi ed, elements will be deenergized.
- The fan will continue to run until the residual heat is removed
from the heater. Then the fan will stop.
Automatic Reset Thermal High Limit
The heater has an automatic reset thermal high limit that will
deenergize the heating elements if the interior temperatures of
heater exceed its setting. The limit will automatically reset when
the heater interior temperatures fall below its setting.
AMERICAN VERSION ONLY
This heater includes a visual alarm to warn that parts of the heater
are getting excessively hot. If the light turns on, immediately
turn the heater off and inspect for any objects on or adjacent to
the heater that may have blocked the airfl ow or otherwise caused
high temperatures to have occured.DO NOT OPERATE THE
HEATER WHEN THE ALARM LIGHT IS ON.
Fig. 1
Model (2 kW to 5 kW)
Standard Ceiling Mounting
INSTRUCTIONS
- The heater motor is permanently lubricated.
- Wait until the housing and heating elements cool before
performing maintenance.
- Once a year, remove the front cover and use a vacuum cleaner or
compressed air to remove the dust accumulation inside the heater.
- Cleaning should be done while the heater is disconnected from
the power supply circuit.
- A qualifi ed technician should perform any other servicing.
WARRANTY
The manufacturer warrants the electric heating element for a
ten (10) year period; and its component parts against defects in
material and workmanship for a one (1) year period following the
date of purchase, under normal use and service, when proof of
purchase of such is provided to the manufacturer. The obligation of
the manufacturer, under the terms of this warranty, will be to supply
a new unit and this omits the manufacturer to bear the installation
costs or other secondary charges linked to replacing the unit or the
component part(s).
KEEP THIS INSTRUCTION PAMPHLET
FOR THE USER
Fig. 2
Model (2 kW to 5 kW)
Drop Ceiling Mounting
SAVE THESE
INSTRUCTIONS
SUSPENDED CEILING MOUNTING (Fig. 2)
1. Never install the air-forced diffuser at less than 8 ft. (250 cm)
from the fl oor and 12 in. (30 cm) from adjacent walls.
2. Convey the wires of power supply to the ceiling space.
3. Suspend the heater fi rmly (without the front cover) using
chains, steel wires (use the supplied hooks) or steel bar
by taking care of leaving enough space between the heater
and the drop ceiling in anticipation of step # 5.
4. Connect the heater leads to the supply leads according
to the national and local codes. See wiring diagram.
5. Gently sit the front cover on the drop ceiling structure.
6. Lower the heater and adjust its height so that it rests on
the front cover already in place.
7. Mount the front cover to the heater using provided screws (4).
OPTIONS
See installation pamphlet provided with the various options for
the installation of those options.
IMPORTANT
Connect the control (thermostat or relay)
to the T1-T2 position on the terminal block.
Do not interrupt power supply to control this heater.
INS134-200404-04
INSTRUCTIONS
INSTRUCTIONS
INSTRUCTIONS
O’Fallon, MO USA 63368 - Tel.: 1 800 695-1901
©2014 Reznor, LLC. All rights reserved. All other trademarks are the
property of their respective organizations.
Reznor LLC
www.ReznorHVAC.com
INSTRUCTIONS
Modèle ECR (2 kW à 5 kW)
AVERTISSEMENT
Lors de l’utilisation d’appareils électriques, il est important de respecter les
règles de sécurité de base, notamment les consignes suivantes, pour réduire
les risques d’incendie, de choc électrique et de blessure.
Lire attentivement ces instructions avant de procéder à l’installation ou
l’utilisation de cet appareil. Ne pas respecter ces instructions peut entraîner
un incendie, une électrocution, des blessures graves, la mort ou des dégâts
matériels. Consultez-les régulièrement pour assurer un bon fonctionnement
sécuritaire et renseigner les futurs utilisateurs, le cas échéant.
INSTRUCTIONS
IMPORTANTES
D’INSTALLATION
ATTENTION
MONTAGE PLAFOND STANDARD (Fig. 1)
D’UTILISATION
L’appareil doit être installé correctement avant de l’utiliser.
MISE EN MARCHE
- Mettre l’alimentation sur le disjoncteur du panneau électrique.
- Thermostat électronique: S’assurer de sélectionner le mode ventiloconvecteur (FAN mode).
- Thermostat intégré anti-vandale, l’ajustement se fait à l’aide d’un
tournevis plat.
- Dès que le thermostat mural ou le thermostat intégré à l’appareil
envoi une demande de chauffage, les éléments commencent à
chauffer et le ventilateur démarre.
- Lorsque la température désirée est atteinte au thermostat, les éléments
cessent de chauffer.
- Le ventilateur continue de fonctionner jusqu’à ce que la chaleur
résiduelle soit évacuée de l’appareil. Le ventilateur s’éteint ensuite de
lui-même.
Protection thermique à réenclenchement automatique
L’appareil est muni d’une protection thermique à réenclenchement
automatique qui éteint les éléments chauffants lorsque la température
interne de l’appareil dépasse sa valeur de réglage. Ce dispositif remet
l’appareil de chauffage en marche dès que la température interne a
baissé sous sa valeur de réglage.
VERSION AMÉRICAINE SEULEMENT
Cet appareil contient une alarme visuelle (lumière rouge) qui vous
indique qu’une composante interne de l’appareil est excessivement
chaude. Si la lumière s’allume, arrêter immédiatement l’appareil
et vérifi er que l’entrée et la sortie d’air ne sont pas bouchées d’une
manière ou d’une autre ce qui causerait les températures trop élevées.
Si aucune obstruction n’est visible, l’appareil doit être vérifi é par une
personne qualifi ée. L’APPAREIL NE DOIT PAS ÊTRE UTILISÉ SI
LA LUMIÈRE EST ALLUMÉE.
D’ENTRETIEN
- Le moteur de l’appareil de chauffage est lubrifi é de manière
permanente.
- Attendre que le boîtier et les éléments de l’appareil aient refroidi
avant de procéder à l’entretien.
- Une fois par an, retirer le plafonnier de l’appareil et utiliser un
aspirateur ou de l’air compressé pour enlever l’accumulation de
poussière à l’intérieur. Le nettoyage doit être fait après avoir coupé
l’alimentation électrique de l’appareil.
- Un technicien qualifi é peut accomplir tous autres services.
GARANTIE
Le manufacturier garantie l’appareil contre les vices de matériel
ou de défauts de fabrication pour une période d’un (1) an et les
éléments chauffants pour d’une période de dix (10) ans. Cette
garantie s’applique en fonction d’un usage et d’un entretien
normal à compter de la date d’achat et sur présentation d’une
facture attestant cette date. La responsabilité du fabriquant est
limitée au remplacement du produit (appareil) seulement et ne
comprend d’aucune façon le coût de branchement ou de la pose
de l’appareil ou de la pièce de remplacement.
CE GUIDE DOIT ÊTRE CONSERVÉ
POUR L’UTILISATEUR
CONSERVER CES
INSTRUCTIONS
MONTAGE PLAFOND SUSPENDU (Fig. 2)
OPTIONS
IMPORTANT
Brancher le contrôle (thermostat ou relais) aux bornes T1-T2.
Ne jamais interrompre la ligne d’alimentation
pour contrôler cet appareil
Fig. 1
Modèle (2 kW à 5 kW)
Montage plafond standard
Fig. 2
Modèle (2 kW à 5 kW)
Montage plafond suspendu
INS134-200404-04