Reya Dolphin Premium 12V10A, Dolphin Premium 12V15A, Dolphin Premium 12V25A, Dolphin Premium 12V40A, Dolphin Premium 24V20A Operating And Users Manual

OPERATING AND USERS MANUAL
UK
12V10A
Code REYA : 399000
12V15A
Code REYA : 399010
12V25A
Code REYA : 399020
12V40A
Code REYA : 399030
24V20A
Code REYA : 399040
Developed by mdp electronics for
Automatic battery chargers
WARNING
BEFORE OPERATION THIS MANUAL CONTAINS VITAL AND ESSEN­TIAL INFORMATION. IN ORDER TO AVOID ELECTRICAL SHOCkS OR OTHER DAMAGE, THE OWNER SHOULD READ AND UNDERS­TAND THIS IMPORTANT DOCUMENT BEFORE OPERATING THE CHARGER.
Contact REYA if you do not understand a state­ment.
This device is not intended for use by persons (in­cluding children) with physical, sensory or men­tal disability, or by persons lacking experience or knowledge, unless they have received from a person in charge of their safety adequate super­vision or preliminary instructions on how to use the device.
Before Installation.
4In order to avoid overcharging or irreversible damage to the materials, please follow closely all recommendations cited below. Do not install
this system near inammable materials. An owner
should seek guidance from an authorized DOL­PHIN dealer or the factory.
4Do not install this device near a heat source.
4It should not be installed in an airtight or badly
ventilated area.
4All ventilation ducts must be unobstructed.
4Leave at least 10 cms / three inches clearance
around the device for proper ventilation.
4Mount in a vertical position, to create natural ventilation for the charger. Note that the wiring connections are at the bottom of the charger.
4All electrical connections to and from the charger must remain accessible at all times.
NOT-PREMIUM rev 02
4This system should not be exposed to water or dust.
4It is strictly forbidden to tamper with the system casing in any way.
4This device is not a toy and must be kept out of the reach of children.
Connecting the Device.
In order to avoid all risk of electric shock or irreversible damage to the device, please follow very carefully the following recommendations
4This device is set to be connected to a mono­phase network 230V 50Hz or 115V 60Hz (except
10A & 15A)
4The installation to which the device is connec­ted must comply with the standards currently en­forced in the country of use.
4In order to protect the occupants, the input point must be attached to a differential circuit breaker. Please refer to the specic characteris­tics of the circuit breaker.
4For security reasons, the system’s PE terminal must strictly be connected to the installation’s
Earth (green/yellow wire in the cable section).
Please consult the wiring diagram.
4To prevent overheating, ensure the correct connection and size of cables.
4The input cable must not exceed 3 meters (10 feet) and the output cable 1.5 meters (5 feet).
4All cable connections and connectors must be maintained in good condition. Once the connection of the AC cable has been comple-
ted it is imperative to t the Winsta Wago snap
on security cover. See “Assembling the Shore Power Connector”
NOT-PREMIUM rev 02
UK
Start up precautions.
In order to avoid all risk of electric shock or irrever­sible damage to the device, please follow very carefully the following recommendations.
4Do not dismantle the device. The housing (pro-
tection against re) must be correctly mounted.
4This device complies with enforced standards; regarding emitted interference, protection against disturbances of external origins (refer to the paragraph on EMC – Technical Specica­tions.)
4When in use, avoid submitting the device to le- vels of interference, in particular electromagnetic and conducted, superior to those legally permit­ted (for example, the devise installed too close to an emitter) as this may cause irreversible da­mage.
4This device emits interference (electromagnetic and conducted) which complies with legal stan­dards. Ensure that materials used are compatible i.e. susceptible, with this device in order to avoid irreversible damage.
Series number.
This reference is found on a grey sticker on the side of the charger. It is made up of: 2 digits in­dicating the manufacturing year; 09 for 2009, a letter representing the month; C for March, and a 4 or 5 digit number indicating the production number.
Rev XX refers to the number of modications /
evolution of the product since its initial launch.
WARNING
NOT-PREMIUM rev 02
NB: Choosing the charging curve.
It is extremely important to choose the correct charging curve, one which is appropriate for the battery’s technology. An incorrect choice could cause irreversible damage.
4This is particularly true for charging curves where the charging voltage is higher than the manufac­turers’ recommended voltage levels.
4There is a high risk of overheating and emission of noxious gases
4Charging curve 4 is compatible with LiFeSo4 batteries that have a BMS (battery management system) installed.
4It is essential to consult the battery manufactu­rer’s recommendations.
Maintenance precautions.
4This device cannot be dismantled and thus the PC board is inaccessible. It is strictly forbidden to dismantle the housing for any reason. Electric shock possible.
4In order to prevent risk of electric shocks during maintenance, please follow closely all recom­mendations below before any maintenance be­gins.
4Any operation carried out to this effect must be carried out by an authorized electrician. In the event of damaged wires or cables, these must be replaced by an authorized electrician. The end user must not attempt to change them.
4The mains and battery connections must be dis­connected before any work is carried out in order to avoid transfer of energy
4Fuses must be replaced by fuses that have the same characteristics and performance levels.
NOT-PREMIUM rev 02
UK
Charging curve 1 Lead open
Battery type: Lead open
V.boost = 14.2V
V.oat = 13.2V
= 28,4V = 26,4V
Charging curve 2 GEL
Battery type: GEL, AGM, Spiral
V.boost = 14,2V
V.oat = 13,7V
= 28,4 = 27,4
Charging curve 3 Lead Calcium
Battery type: Lead Calcium
V.boost = 14,8V
V.oat = 13,7V
= 29,6 = 27,4
Charging curve 4 Power Supply or LiFeSo4 with integrated BMS
Battery type: Power supply or LiFeSo4+BMS
V.boost = 14,2V
V.oat = 14,2V
= 28,4 = 28,4
Weekly Equalization
automatic
Voltage Allowance +/- 2% Residual wave < 1% pp (BW < 20 MHz) Current 10A 15A 25A 40A 20A
Fuse
F15A
32V
Automotive
F20A
32V
Automotive
2xF15A
32V
Automotive
2xF25A
32V
Automotive
2xF15A
32V
Automotive
Protections
Against output overload, output short circuit,
excessive internal temperature, excessive battery temperature, output overvoltage,
battery reverse polarity (fuse)
General
Display
Tricoloured LED
Night mode (Diagram B)
/ / Button
Operating temp -10°C to +50°C / +14°F to +122°F Storage temp -20°C to +70°C / -4°F to +158°F Humidity 10% to 90% (without condensation) Ventilation Natural Forced fan cooling EMC EN61000-6-3 & EN61000-6-1 Security EN60335-2-29 (2002) Housing White aluminium – wall mounted Mounting 2 x 4mm screws Dimensions
(mm)
238(h)x120.5(w)x95.6(d)
354(h)x120.5(w)x 95.6(d)
Weight 1.3 kg / 2.87lbs 1.9 kg / 4.2lbs
Ac Connection
3 points, 20A 230V, 4mm
2
max
Ref : 770.813/G11-000 (WINSTA - WAGO)
Battery Connection
4 points, 40A 630V, 10mm
2
max
Ref : PC 6-16/4-G1F-10,16 (PHOENIX CONTACT)
12V 10A 12V 15A 12V 25A 12V 40A 24V 20A
WARNING
NOT-PREMIUM rev 02
Charge selector
Diagram A :
TECHNICAL SPECIFICATIONS
NOT-PREMIUM rev 02
UK
Button – Night Mode
Diagram B :
Input
Tension
230V +/- 15%
115V please
consult us
115V - 230V
(+/- 15%)
Frequency 50Hz - 60Hz (+/- 10%) Cos phi 0.6 typ 0.9 typ
Efciency 80% typ
Mains consumption 1.3A 1.9A 4A/2A 7A/3.5A
Fusible
T2A
250V
5x20mm
T3, 15A
220V
5x20mm
T6A
250V
5x20mm
T10A 250V
5x20mm
Output
Nb of outputs
3 isolated outputs
Nb charginig curves 4 possible charging curves.
Selection by external dip-switch
Curves types IUUo & automatic weekly equalization
Charging
proles
(Diagram A)
12V 10A 12V 15A 12V 25A 12V 40A 24V 20A
OPERATING INSTRUCTIONS
MODE
Absorption
Equalisation
End of Equalisation
Floating
Internal Temperature fault
Output voltage fault
Battery fuse fault
“Night” Mode 12V-25A 12V-40A 24V-20A
LED
Steady
yellow
(1)
Yellow
blinking
(2)
Green
blinking
(3)
Green (4)
Red
xed
(5)
Red
blinking
(6)
Red
Flashing
(7)
-
STATUS
The batteries are charging. Time required to complete Absorption mode varies depending on the initial status of the batteries, but is limited to 6 hours.
The batteries are coming to the end of the charging cycle. Time required to complete Equalization mode, depen­ding on the initial status of the batteries, varies from 30 minutes to 4 hours.
The batteries are almost charged. Floating mode will begin in less than 30 minutes.
The batteries are completely charged.
The charger is on Standby for a period of between 30 seconds and 10 minutes. Once the fault has been solved, the device will start up again automatically.
4If this problem arises, please
check the external temperature as well as the internal fan and the space around the charger.
The charger is on Standby for a pe­riod of 30 seconds. Once the fault has been solved, the device will start up again automatically.
4In reality, the PC Board has pro-
bably failed and the damage is irreversible.
The fuse should be replaced.
4Please check all connections as
well as the battery’s polarity and
status
This mode allows the charger to work without noise (from the fan). In this case, charging levels adapt. To activate this mode, press the button for about 2 seconds. To deactivate, a simple press of the button or the mode deactivates automatically after 10 hours.
NOT-PREMIUM rev 02
(1) (2)
(3) (4)
(5) (6) (7)
RACCORDEMENTS
Mounting (4mm screws)
Bottom
(Connector side)
Top
Program selector
Night mode selector button
Battery Fuse
Recommended
cable size
12V10A : 2.5 mm2 / 12 AWG
12V15A : 2.5 mm
2 /
12 AWG
12V25A : 4.0mm
2 /
10 AWG
12V40A : 6.0 mm
2 /
8 AWG
Lg cables : 1.5 m / 4.9 feet max
Recommended cable size
12V10A : 3 x 0.75 mm2 / 18 AWG 12V15A : 3 x 0.75 mm
2 /
18 AWG
12V25A : 3 x 1.5 mm
2 /
14 AWG
12V40A : 3 x 1.5 mm
2 /
14 AWG
Lg cables : 3 m / 9.8 feet max
12V-25A 12V-40A
24V-20A
12V-10A 12V-15A
Program selector
Battery Fuse
NOT-PREMIUM rev 02
UK
Cable type: according to local regulations
CONNECTION
NOT-PREMIUM rev 02
Wiring diagram
Assembling the shore power connector
7STEP 1:
Remove approx 2 cm of the outer sheath Remove approx 8 mm of the inner wires’ sheaths Tinplate the bare copper ends
7STEP 2:
Remove the security cap using an utility knife
7STEP 3:
Pull the conductor through the pre latched strain relief housing
7STEP 4:
Open the clamp with a screwdriver and insert the rst
cable up to the stop. Repeat this step for all three cables.
7STEP 5:
Latch the connector on to the strain relief housing.
7STEP 6:
Snap together the upper and lower parts of the strain relief housing and tighten it using the screw.
Dispatching
UK
DIMENSIONS
Dimensions 12V-10A / 12V-15A.
Dimensions 12V-25A / 12V-40A / 24V-20A
x2 ø5mm
20mm
[0.79inch]
95,6mm
[3.76inch]
120mm
[4.74inch]
238mm [9.37inch]
210mm [8.27inch]
352,5mm [13.88inch]
326mm [12.83inch]
120mm
[4.74inch]
95,6mm
[3.76inch]
20mm
[0.79inch]
x2 ø5mm
NOT-PREMIUM rev 02
WARRANTY
IN ORDER TO PREVENT ALL RISkS ARISING DUE TO THE INCORRECT USE OF THIS DEVICE, PLEASE CAREFULLY READ THE LIST OF POSSIBLE SITUA­TIONS OR FAULTS THAT ARE NOT COVERED BY THE WARRANTY.
4If the mechanical components of the device are not protected by the casing and fall, irreversi­ble damage of the ventilation system and certain electrical components may result.
4Modications made to the casing (and in parti- cular if holes are bored), may result in the deposit
of metallic shavings or lings onto the electronic
card and consequently may cause the malfunc­tion of or damage to the device.
4Interfering with or modications made to the
PC Board may result in unforeseen operations and consequently may cause the malfunction of or damage to the device.
4Use of a non-adapted power supply (as a ge­neral rule, the input voltage will be too high) may cause the malfunction of or damage to the de­vice.
4Over voltage from the mains or a lightening strike will usually cause irreversible damage to the PC Board.
4Replacement of battery fuses with fuse types other than those recommended (same charac­teristics) may cause the malfunction of or dama­ge to the device.
4Obvious connection errors will result in the mal­function of or damage to the device.
4Water gaining access to the interior of the de- vice may cause the malfunction of or damage to the device.
NOT-PREMIUM rev 02
NB: Choosing the charging curve.
It is extremely important to choose the correct charging curve one which is appropriate for the battery technology. An incorrect choice could cause irreversible damage.
4This is particularly true for charging curves where the charging voltage is higher than the manufac­turers’ recommended voltage levels.
4There is a high risk of overheating and emission of noxious gases
4Charging curve 4 is compatible with LiFeSo4 batteries that have a BMS (battery management system) installed.
4It is essential to consult the battery manufactu­rer’s recommendations.
Disposal.
This device contains electronic components & material that must be recycled once the device is obsolete. All obsolete electronic devices must be returned to a local distributor or to a specialized company for an environmentally friendly disposal.
NOT-PREMIUM rev 02
WARRANTY
UK
CE CONFORMITY
This product conforms to current European standards and has a CE mark. Please consult us for
the certicate of conformity.
For further information or assistance,
please contact:
REYA SAS
2599 Route de la Fènerie
06580 Pégomas
FRANCE
Tél : (33) 0 493 904 700
Fax : (33)0 493 902 440
e-mail : export@reya.com
www.reya.com
Loading...