Revolabs 8000, Tandberg 6000 User Manual

Page 1
Revolabs Single Channel Wireless Microphone System- Tandberg 6000 / 8000 MXP Setup Guide
NOTES AND CAUTIONS:
This setup guide will guide you through the steps needed to properly connect a Revolabs Single Channel System to a Tandberg 6000 / 8000 MXP video codec.
2. Configuring the 6000 / 8000 MXP Video Codec
Note:
It is important to carefully follow these instructions in order and completely. Otherwise your Single Channel System and/or the video codec may not function properly. Please read through these instructions completely before proceeding. Contact Revolabs technical support if you have any questions.
Requirements for connecting systems:
1. Revolabs Single Channel System
2. Tandberg 6000 / 8000 MXP video codec
3. QTY 1 07-STEMIC-PPP Line-to-Mic Interface Cable*
* OPTIONAL FROM REVOLABS
NOTE: IMAGES OF SET UP SCREENS ARE DEFAULT SETTINGS FROM TANDBERG AND ARE PART OF THE TANDBERG MXP ADMINISTRATORS GUIDE © MAY 2008
Page 2
Connecting the Cables
CONNECTING A REVOLABS SINGLE CHANNEL TO TANDBERG 6000 / 8000 MXP VIDEO CODEC
1. Connect the 07-STEMIC-PPP cable between the 2.5mm analog output of the Revolabs Single Channel to the MIC 1 input of the Tandberg 6000 / 8000 MXP
Page 3
Configuring the 6000 / 8000 MXP Video Codec
CONFIGURING THE AUDIO MENUS OF THE 6000 / 8000 MXP VIDEO CODEC
1. Go to AUDIO SETTINGS
2. Select INPUTS
3. Confirm that MIC 1 is ON
4. Adjust the audio Input Type Level if necessary (recommend +8dB)
5. Speak into the Revolabs microphones that are connected to MIC 1. The audio meter should peak at about 5dB for normal speech.
Page 4
6. Return to previous menu and select ECHO CONTROL
7. Enable MIC 1 Echo Canceller (ON)
8. Return to previous menu and select AUDIO LEVELING (AGC)
9. Turn MIC Audio Leveling (AGC) OFF