Revolabs 01-8FUSIONEU-62, 05-TBLMICEU-OM-BLK-11, 01-4FUSIONEU-31, 03-EXEMICEU-BLK-11, 03-EXECHGEU-STD-11 Installation And User Manual

...
Microphones must be fully charged and paired to the
Charger Base prior to first use.
Rev 1.1
Revolabs Fusion™ Wireless
Microphone System
Page 2
Table of Contents
8-Microphone System
01-8FUSION-NM or 01-8FUSIONEU-NM (No microphones)
01-8FUSION-62 or 01-8FUSIONEU-62 (6 omni tabletops/2 wearable)
4- Microphone System
01-4FUSION-NM or 01-4FUSIONEU-NM (No microphones)
01-4FUSION-31 or 01-4FUSIONEU-31 (3 omni tabletops/1 wearable)
Part Numbers Covered in This Document
Page 37
EUROPEAN COMPLIANCE
This equipment has been approved in accordance with Council Directive 1999/5/EC “Radio Equipment and telecommunications Equipment.
Conformity of the Equipment with the guidelines below is attested by the CE mark. Model Numbers: 01-8FUSIONEU-NM Revolabs Fusion Base Station, European 01-4FUSIONEU-NM Revolabs Fusion Base Station, European 01-8FUSIONEU-62 Revolabs Fusion System with 6 tabletop
omni’s & 2 wearable mics, European
01-4FUSIONEU-31 Revolabs Fusion Base System with 3
tabletop omni’s & 1 wearable mics,
European 03-EXEMICEU-BLK-11 Revolabs Solo™ Executive Microphone 03-EXECHGEU-STD-11 Revolabs Solo™ Executive Charger 05-TBLMICEU-OM-BLK-11 Revolabs Solo™ Executive Table
Microphone Omni 05-TBLMICEU-DR-BLK-11 Revolabs Solo™ Executive Table
Microphone Cardioid 06-XLRMICEU-OM-BLK-11 Revolabs Solo™ Executive XLR
Microphone Adapter
STANDARDS TO WHICH CONFORMITY IS DECLARED: RF ETSI EN 301 406 V 1.4.1 03/2001 EMC ETSI EN 301 489-6 v1.2.1 (2002-04)
WEEE NOTIFICATION:
The Waste Electrical and Electronic Equipment (WEEE) directive (2002/96/EC) is intended to promote recycling of electrical and electronic equipment and their components at end of life.
2003/11/EC & 2002/95/EC “ROHS COMPLIANCE DIRECTIVE”: The products referenced herein are in compliance with the EU directive 2003/11/EC and EU directive 2002/95/EC.
SAFETY COMPLIANCE
TUV SUD AMERICA
Revolabs Fusion™
INDUSTRY CANADA NOTICE TO USERS Operation is subject to the following two conditions: (1) This device may not cause interference and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
IC: 6455A-01FUSION Revolabs Fusion™ Base Station 8 microphones IC; 6455A-01FUSION4 Revolabs Fusion™ Base Station 4 microphones IC: 6455A-01EXEMIC Revolabs Solo™ Executive Microphone
RESTRICTED USE WITH CERTAIN MEDICAL DEVICES
Hearing Aids
Some devices may interfere with some hearing aids. In the event of such interference, you may want to consult with your hearing aid manufacturer to discuss alternatives.
Other Medical Devices
If you use any other personal medical device, consult the manufacturer of your device to determine if it is adequately shielded from RF energy. Your physician may be able to assist you in obtaining this information.
EXPORT LAW ASSURANCES
This product is controlled under the export regulations of the United States of America and Canada. The Governments of the United States of America and Canada may restrict the exportation or re-exportation of this product to certain destinations. For further information contact the U.S. Department of Commerce or the Canadian Department of Foreign Affairs and International Trade. The use of wireless devices and their accessories may be prohibited or restricted in certain areas. Always obey the laws and regulations on the use of these products.
01-FUSION-8CH-NA & 01-FUSION-4CH-NA North America UPCS Usage Restriction
Due to the UPCS frequencies used, this product is licensed for operation only in the United States of America and Canada.
01-FUSION-8CH-EU & 01-FUSION-4CH-EU European Union Usage Restriction
Due to the DECT frequencies used, this product is licensed for operation only in the European Union countries.
Page 36
Installation Guide
Revolabs Fusion™
Page 3
Great audio, wireless mobility, and simple to install!
Simply plug the cable into the AV system or phone system and it works. No software configuration is necessary. Even the Fusion box is designed to be easy to use– vertically or horizontally. No equipment rack needed! Just set the Fusion system on the credenza!
Video Conferencing
Revolabs Fusion Wireless Microphone Solution includes all of the necessary cables to plug into any of the major video-conferencing solutions, including Lifesize, Polycom, Sony and Tandberg. It includes a remote control to control the sound volume in your conference room or in the conference room at the far end. Decide on where you want to put the Fusion system, whether you want to place it vertically or horizontally, plug in the cables and you are ready to have great wireless audio in any conference room!
Audio Conferencing
Plug the Fusion Wireless Microphone Solution into a telephone system and you are on your way to great wireless audio. There is a remote control dialer to dial the conference phone number and you may purchase new powered speakers or use existing powered speakers to hear the call. Decide on where you want to put the Fusion system, whether you want it vertical or horizontal, plug in the cables and you are ready to have great wireless audio in any conference room!
Rechargeable These Wireless Microphone Systems have a rechargeable battery that provides eight hours of talk time after each full charge. Revolabs Wireless Microphones recharge to 85% capacity in approximately 45 minutes.
Secure All of Revolabs Wireless Microphones use 128-bit encryption, so that no one can listen in.
Installation Guide
Page 4
Contents of box:
Fusion Base Station, Fusion Base Station vertical stand, AC power adapter for Base Station, four cables shown below, remote control, Charger Base, AC wall adapter for Charger Base, four or eight wireless microphones (optional). Optional boxes: Four or eight wireless microphones, Remote IR Sensor, speakers.
Fusion Set-up
Decide if want to place Fusion Base Station horizontally or vertically on a flat surface. To set-up vertically, place the Fusion Base Station vertical stand on the bottom of the Fusion unit. Tighten bolt into Fusion Base Station.
Fusion Base Station Placement
WARNING: Do not put Fusion Base Station behind metal doors.
If you are putting Fusion into a cabinet with non-metal doors, you need to use the Remote IR Sensor (part number 07-IRREMO-01) for remote to work. Plug the serial port end into the IR Remote port on the back Fusion panel, bring IR Sensor out of cabinet, and secure with Velcro.
Power
Plug power cord into the back of the Fusion Base Station and into wall outlet. Plug AC Adapter into the power outlet and the other end into the microphone Charger Base. Place wireless microphones in the Charger Base, let charge overnight or at least eight hours.
CABLE A
Speakers
CABLE B
Phone Cable
CABLE C
RCA
CABLE D
XLR
Page 35
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, it not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is en­couraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Revolabs Fusion™
Safety and General Information
Please read the following information to ensure safe use of your Revolabs system.
FCC User Information
FCC Registration Number: 0014898290 FCC ID: T5V-01-FUSION Revolabs Fusion™ Base Station 8 microphones FCC ID: T5V-01-FUSION4 Revolabs Fusion™ Base Station 4 microphones FCC ID: T5V-01-EXEMIC Revolabs Solo™ Executive Microphone
FCC NOTICE TO USERS
Users are not permitted to make changes or modify the equipment in any way. Changes or modifications not expressly approved by Revolabs, Inc. could void the user’s authority to operate the equipment. To meet FCC and Industry Canada RF radiation exposure limits for general population (uncontrolled exposure), a minimum of 7.9 inches (20 cm) separation distance must be maintained between the Fusion Base Station and users' and/or nearby persons' bodies at all times. Additionally, the Fusion Base Station must not be co-located with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This product has been found to comply with the Rules of 47 CFR Part 68 of the Federal Communications Commission and Technical Requirements For Connection of Terminal Equipment to the Telephone Network TIA-968-A-1, A­2 and A-3.
Certificate Number: US:6RMBR00BNEXIATC Date: April 14, 2006 IMPORTANT NOTE: FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIATION EXPOSURE STATEMENT This equipment complies with FCC radiation exposure limits for an uncontrolled environment.
Page 34
Installation Guide
Revolabs Fusion™
Audio Conferencing
Plug Cable A (single RCA to double RCA) single RCA connector into Fusion Base Station <Room Out> RCA port, and then plug the double RCA connectors into the speakers. Plug speakers into wall outlet. Must be powered speakers or a powered amplifier.
Plug one end of Cable B, the phone line cable, into the Fusion Base Station <Line In>, plug other end into phone jack. Dial with the remote.
If you ordered 01-8FUSION-62 6 omni tabletops/2 wearable microphones or 01-4FUSION-31 3 omni tabletops/1 wearable microphone. You are all set to go! Take out the Wireless Microphones, unmute them by pressing the mute button on the microphone and the system is ready for a conference!
If you selected your microphones separately with the 01-8FUSION-NM or 01-4FUSION-NM Fusion part numbers, you must first establish a connection between your microphones to the Fusion Base Station. This is called “pairing”. Refer to page x.
Video Conferencing
You must have the audio output going to a display with speakers coming from the Fusion Base Station, not the Video-conferencing Station. Plug Cable A (single RCA to double RCA) single RCA connector
into Fusion Base Station <Room Out> RCA port and then plug the double RCA connectors into the speakers or display with speakers.
Once you have configured your video-conferencing station as follows, then: If you ordered 01-8FUSION-62 6 omni tabletops/2 wearable microphones or 01-4FUSION-31 3 omni tabletops/1 wearable microphone. You are all set to go! Take out the Wireless Microphones, unmute them by pressing the mute button on the microphone and the system is ready for a conference! If you selected your microphones separately with the 01-8FUSION-NM or 01-4FUSION-NM Fusion part numbers, you must first establish a connection between your microphones to the Fusion Base Station. This is called “pairing”. Refer to page x.
Page 5
Installation Guide
Lifesize Installation
Plug red RCA connector of Cable C, the double RCA to double RCA cable, into the Fusion Base Station <Conf Out>, then plug the other end red RCA connector into the Lifesize video-station <Conf In>. Plug black RCA connector of Cable C, into the Fusion Base Station <Conf In>, and the other black RCA connector into the Lifesize video-station <Conf Out>.
Specifications
Dimensions, (L, W, H) and Weight: Fusion Base Station 16.45” (41.8 cm) x 8.46” (21.5 cm) x 1.7” (8.7 cm), 8.7 lbs (3.95 kg) Charger Base 8.3” (21.1 cm) x 4.3” (10.9 cm) x 1.0” (2.56 cm), 1.0 lb (0.45 kg) Wireless Microphones Wearable: 0.9” (2.3 cm) x 0.8” (2.0 cm) x 2.6” (6.6 cm), 0.05 lb (0.02 kg) TableTop: 1.5” (3.8 cm) x 0.8” (2.0 cm) x 3.3” (8.4 cm), 0.05 lb (0.02 kg) XLR Adapter: 0.9” (2.3 cm) x 0.8” (2.0 cm) x 4.0” (10.2 cm), 0.05 lb (0.02 kg) Radio Frequency: 01-8FUSION-XX 1.92 to 1.93 GHz (UPCS North America) 01-4FUSION-XX 1.92 to 1.93 GHz (UPCS North America) 01-8FUSIONEU-XX 1.88 to 1.90 GHz (DECT EU) 01-4FUSIONEU-XX 1.88 to 1.90 GHz (DECT EU) Connectors: Fusion Base Station IR Remote Serial DB9 CD Programming Serial DB9 - for Revolabs use only Audio Control RJ45 – for Revolabs use only Telephone Line-In RJ11 Telephone Set-In RJ11 Network RJ45 – for Revolabs use only XLR male Aux In RCA Plug Aux Out RCA Plug Record Out RCA Plug Room Out RCA Plug Conference In RCA Plug Conference Out RCA Plug Charger Base DC power input port, Proprietary 4 pin microphone charge jacks Microphone Proprietary 4 pin charge plugs, 2.5mm mono earplug port Power Requirements: Fusion Base Station 100-240V AC, 50-60 Hz, 10W (power cable varies by country) Charger Base 5V DC, 2 Amps (switching power supply varies by country)
Range: 100’ (30 meters) approx. (no obstructions) Maximum Microphones:
01-8FUSION-XX, 01-8FUSIONEU-XX 8 channels maximum 01-4FUSION-XX, 01-4FUSIONEU-XX 4 channels maximum
Battery: Lithium Polymer, 8 hours approx. talk time Charge Time: 2 hours approx. Audio Bandwidth 100-7000 Hz Security: 128-bit DSAA (DECT Standard Authentication Algorithm) authentication,
64 bit DECT Standard Cipher
Page 33
Revolabs Fusion™
Loading...
+ 13 hidden pages