AN AIR–WATER HEAT PUMP
FOR HEATING AND COOLING WITH A BUILT-IN
ELECTRIC BOILER
Model: LWRc-8kW
Operational Manual (7.4.2014)
• Read this manual carefully; failure to do so could cause irreversible damage to
your device
• The REVEL Company will not be liable for any damage caused by the
installation or the assembly of the heat pump in a manner that is
in contradiction with this Operational Manual
• The effective ambient air temperature must be between -20 °C and + 43 °C
• The temperature of the water entering the heat pump must not exceed 60 °C
On very cold days the built-in electric boiler or another heat source may be connected
(see the bivalence points on the chart below)
Illustration of the heat pump function
Heat transferred
to water

Important Information
1. In the case of using water or simply an additive mixture, it is necessary to
ensure the continuous operation of the circulator that causes the water to flow
through the LWRc-8kW. It is recommended to use a 5% industrial ethanol as an
additive mixture based on its extending of the freeze function and the radical
reduction in the tear strength of the ice.
2. When operating at low temperatures, the unit automatically provides defrosting,
which is accompanied by the drainage of the defrosted air-humidity condensate
in a volume of 0–1 litres per hour.
3. The device comes equipped with a heating cable that is in operation during
defrosting. It is functional to lead the heating cable loop into a sewer or a
drainage outlet, for example.
4. In the event of the accidental occurrence of poor drainage of the condensate and
the subsequent freezing of the heat pump, it is necessary to defrost the device by
means of a brief external intervention, e.g. using a tent and a heat gun.
It is necessary to protect the heat pump at the inlet of heating water by a
regularly cleaned filter
5. It is possible to purchase an installation kit (USP) for the heat pump that
implements both a protective and an operational function. When installing it
into an existing heating system with the possibility of the temperature reaching
more than 60 °C, its use represents a condition for granting a warranty for the
heat pump.
The Technical and Performance Parameters of the HP
Nominal heating/cooling capacity
Power supply for the compressor and the electric boiler
Operating current /max. current at start-up
Electric boiler power input
Effective working temperature
Dimensions (length/width/height)

Heat loss of the house (kW)