Reval Onyx Directions For Use And Maintenance

ELECTRIC HI-LO BATHTUB
"ONYX" REF: 7440
DIRECTIONS FOR USE AND MAINTENANCE
It is essential to read these directions for use before using your bathtub.
A4AN7440UK.doc
Picture: Electric Hi-Lo Bathtub "Onyx" ref: 7440.00
Reval Continuing Care Ltd Unit 15 Brynmenyn Business Centre St. Theodore’s Way Brynmenyn Industrial Estate Bridgend S Wales CF32 9TZ Tel: 01656 721 001 Fax : 01656 720 006 sales@revalcc.com
- SUMMARY -
CONTENTS PAGES
GENERAL DRAWINGS / MEASUREMENTS 3
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
OPERATION 4
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TECHNICAL SPECIFICATIONS
GENERAL 4 TUB 4 PLUMBING 4 ELECTRICITY 4
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
DIRECTIONS FOR USE :
SHOWER HEAD 5 FILLING 5
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AIR WHIRLPOOL (IN OPTION)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AUTOMATIC STOP FILLING (IN OPTION)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CHROMOTHERAPY (IN OPTION)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
HYDRO-AROMATHERAPY (IN OPTION)
OPERATION 8
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CLEANING / MAINTENANCE
CLEANING OF THE TUB AND CONTROL PANEL 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MAINTENANCE FORM (LOGBOOK) 10
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UP / DOWN 5
OPERATION 6
OPERATION 6 CONTROL PROCESS OF THE CAPACITIVE SENSORS 6
OPERATION 7
CLEANING OF THE AIR WHIRLPOOL SYSTEM 9
Page 2/10
A4AN7440UK.doc
GENERAL DRAWINGS:
Sense mixer (bath & shower)
cleaning shower
shower flow valve
whirlpool control (option)
filling spout
approved shunting box of grounds
cold water feeding
+/-
~
MEASUREMENTS:
215cm
+/-
~
70cm
hi/lo sensitive control
aromatherapy control (option) chromatherapy control (option)
draining
doot to access to the plumbig components
door to access to the electric components
hot water feeding
110cm
12 nozzles for whirlpool (option)
draining plug
positions for feet-wedge
150cm (7440.00)
125cm (7440.01)
175cm (7440.00) 150cm (7440.01)
100cm
15cm
152cm
230cm (7440.00) 200cm (7440.01)
adjustable jack foot
handgrip
45cm
23cm
49cm
55cm
40cm
62cm
80cm
Page 3/10
A4AN7440UK.doc
OPERATION:
Hi/Lo of the bathtub "Onyx" is obtained thanks an electric jack and a gas jack, the first one is driven by an electric control.
To activate bath fill place hand over the bath fill sensor within 30mm. Bath will fill automatically to the fill level and stop automatically when water level indicator is reached. The water level can be stopped and restarted at any time.
Water temperature is adjusted simply by placing your hand over the hot or cold adjustment sensor.
A thermostaticley control patient shower is located in the mid position of the tub. This can be operated in a same way as the bath fill. The shower is programmed to run for two minutes then will stop automatically. The shower can be started or stopped at any time. The spray patterns can be adjusted on the shower head and the flow pressure can be adjusted via the flow adjustment control lever on the front of the bath.
A compressor assures whirlpool (in option). That is injection of air under pressure with adjustable flow through 12 nozzles equipped with anti-return valve and set at the bottom of the tub.
TECHNICAL SPECIFICATIONS:
GENERAL :
Maximum water volume (long bath) : 200 liters
Maximum water volume (short bath) : 180 liters
Adjustable height from 62 to 102cm
Empty weight (long bath) : 120 kg
Empty weight (short bath) : 110kg
Filling time: ~4 minutes to 3 bars
TUB :
Reinforced fiberglass tub white colour
Ergonomic tub without asperities with side handles.
PLUMBING :
Rada sense bath & shower concealed digital mixing valve offering programmable max, min & default temperatures, automatic temperature on outlet selection, duty flush and thermal disinfection with datalogging capabilities.
Shower flow control button.
Adjustable spray handset with 3 different spray actions.
Manual draining & overflow line.
Ø 50mm draining plug.
ELECTRICITY :
General electric feeding : 230V - 50Hz - 180W
General electric feeding with whirlpool: 230V - 50Hz - 1180W
Electric jack : 24V - 5,2A - IP66 - stroke 400mm -3000N
Pump of air whirlpool : 230V - 50Hz - 700W
Heater : 300W
Whirlpool control board: 5V
Page 4/10
A4AN7440UK.doc
TECHNICAL SPECIFICATIONS:
CONFORMITY:
73/23/CEE (low voltege directive)
89/336/CEE (EMC directive)
NF EN 60335-1 (electric standard for bathtub..)
NF EN 60335-2-60 (electric standard for bathtub...)
NF EN 1717 (Anti-pollution)
WRAS (n°0712094)
TMV2
TMV3
DO8
DIRECTIONS FOR USE:
ADJUSTMENT OF THE WATER TEMPERATURE
To adjust the water temperature,, pass your finger in front of the cold water sensitive captor (blue triangle) or in front of the hot water (red triangle) according to the temperature desired.
Cold
adjustment
sensor
Warm
adjustment
Sensor
Factory pre-set with PDA:
-Max outlet temperature for bath: 44°C.
-Max outlet temperature for shower: 41°C.
-Min outlet temperature for bath: 37°C.
-Min outlet temperature for shower: 33°C.
-Default outlet temperature for bath: 38°C.
-Default outlet temperature for shower: 36°C.
-Flow times (bath): 3min30s, allow to fill until “max water level” indication.
-Flow times (shower): 2min
BATH FILLING
The filling cavity of the Transcare tub requires less then 90 litres of water to be filled to its maximum level. When the tub is placed in recline position, this amount of water is sufficient to fully immerse the client. Fill only to the maximum water level indicator. The overflow drains are designed to prevent an accidental overflow.
Check the water temperature. If necessary , adjust it via the digital mixer.
Close the drain plug by turning the button in a clockwise direction.
Pass the finger in front of the pictogram of the tap.
WATER ADDITION
It is possible to add water into the bath when it is tilted. However, before levelling the bath to its upright position, the water level must be decreased by opening the drain plug to avoid water overflow and splashing.
Page 5/10
A4AN7440UK.doc
DIRECTIONS FOR USE:
PATIENT SHOWER
The shower head can be operated at any time.
Pass the finger in front of the pictogram of the shower head and adjust the flow intensity with the tap in
front of the bath.
Select the desired temperature by adjusting the temperature valve as described above.
The shower head spray can be adjusted from a wide to narrow flow.
After each use, turn off the valve.
THERMIC DESINFECTION
The « rada sense » control box is equipped with a system of thermic disinfection for its pipes, which is controlled by a PDA. Only a recognised technician can do this operation, so please call REVAL CC.
HYDROTHERAPY
Heated compressed fresh air is passed into the tub via 12 diffusers witch are aimed at the major muscle groups around the body. This helps to develop muscle tone, improved circulation and patient relaxation.
blower on / off
LED green colour
+/-
~
blower variable speed
blower massage mode
Auto switch off : 30 minutes after the user operates one of the buttons the last time The blower will switch OFF automatically.
Drying cycle : 30 minutes after manual or auto switch OFF, the blower starts up at High Speed for 2 secondes. Then it drop to Low Speed and increase gradually to High Speed within half a minute. Then it continues running 4 or 5 minutes at High Speed.
MAINTENANCE:
CLEANING THE CONTROL PANEL
To clean the “rada sense” control panel, take the magnetic key located behind the security door in front of the bath and pass it in front of the infra red of the control panel to desactivate it. To reactivate the control panel, do the inverse operation.
Page 6/10
A4AN7440UK.doc
CHROMOTHERAPY (OPTION):
Chromotherapy is dynamic LED (light emitting diode) therapy which utilises no less than two pairs of 51 coloured LED’s positioned under the bathwater level, designed to colour the bathwater and room lighting to provide a uniquely relaxing and atmospheric experience for service users. The LED’s automatically alternate in colour and on/off switching. This can also be set to manual adjustment for fine tuning the mood of the bathroom to suit the mood and requirements of the user. There are several lighting sequences that will create the perfect atmospheric sensation. This coupled with Reval's Hydro-Aromatherapy system deliver the ultimate in bathing comfort, relaxation and rehabilitation. The Chromotherapy control button allows the user or care giver total control when using the chromotherapy function. The chrome circular surface mounted button pad with function mode LED which informs the user as to the function status.
There are three main function modes:
1. On/Off - press function button once to switch on (led stable)
2. Auto colour change sequence - press button again for two seconds to activate auto colour sequence (LED flashes intermittently)
3. Manual colour sequence – press once to switch to manual colour sequence then again when you wish to change colour. After the sequence has run the system will switch to off mode! To reactivate, follow steps 1-3.
Page 7/10
A4AN7440UK.doc
HYDRO-AROMATHERAPY (OPTION):
Reval give all areas of patient well being and safety careful consideration. Its unique “Hydro-Aromatherapy” system combines the benefits of hydro-massage with the relaxing aromatic effects, of infused aroma essence, providing the ultimate bathing and rehabilitation experience. The “Hydro- Aromatherapy” system is compressed heated fresh air technology, which infuses aroma therapy oils at temperature into the hydrotherapy air jet which explodes into the bath water delivering controlled therapy with sensual and relaxing aromas assuring a totally unique and wonderful experience. Reval's new “Hydro-Aromatherapy” system has an ultra safe auto-clean function which self dries and cleans the internal air ducting pipe work after use automatically. The auto-clean function significantly reduces the risk and development of micro -biological organisms that can develop in humid and wet environments. Reval's unique air ducting system can be dismantled without the need for tools and can be termically cleaned during routine servicing in a matter of minutes. .
To operate:
1. Simply remove the chrome cap, take the wooden spatula, soak in aromatherapy oil and replace it in to the essence well. Replace the chrome cap) finger tight). Do not over tighten!
2. Switch the Hydro Aromatherapy system on via the circular control panel. Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bottom of the bath tub. The aroma is carried inside the bubbles and explodes on contact with the water releasing the sensual aromatic fragrances in to the air.
3. For extended use switch off and re-soak the spatula as described in points 1&2.
4. The hydro Aromatherapy has an alternating intensity function. To activate this potion press the button on the control panel. The intensity will increase and decrease automatically providing needed therapy without sensitivity and discomfort for those with sensitive joints and skin conditions.
5. The intensity can also be set at a fixed pressure for those who enjoy the continuous sensation and work­out. To fix the intensity level simply press the + or – button on the control panel until the desired intensity has been found.
6. To switch off press the middle button on the control panel marked 1/0.
7. The Hydro Aromatherapy system has a self cleaning function called “Auto Clean” Once the system has been switched off the status LED on the On/Off button changes from ON to Intermittent flashing. This indicates that the system has gone into stand-by mode and will Automatically switch on again and run for 5 minutes self drying any build up of humidity in the internal hydro plumbing system. After five minutes the system will shut down.
A4AN7440UK.doc
Page 8/10
CLEANING / MAINTENANCE:
CLEANING OF THE TUB AND CONTROL PANEL :
Only use liquid products (liquid soap).
Don't use abrasive products like "scouring cream" to avoid scratches on the tub surface "Gelcoat".
Furthermore, to eliminate calcareous marks settled by water moving, we recommend to use the scaler (Gel Servex ).
Do not swill down the outside of the tub.
Do not use liquid soap and the scaler (Gel Servex) on the control panel elements;
Thermostatic mixer, hi/lo sensitive control and whirlpool control.
DISINFECTION OF THE TUB
Spray a suitable cleaner or disinfectant onto the interior tub surface.
Let the disinfectant act the amount of time recommended by the manufacturer of the product.
Thoroughly rinse the interior tub surfaces.
Dry the interior tub surfaces with a soft cloth.
CLEANING OF THE AIR WHIRLPOOL SYSTEM
-For the efficient functioning of the whirlpool system, the nozzles have to be cleaned on a regular basis ( at
least once a year).
-Functioning of a whirlpool’s nozzle. Air is
blown through the nozzle and is discharged under the chromed air jet cap.
-There is a risk of heating the air jet cap if the
nozzles are not regularly cleaned. Layers of soap or deposit can hinder the circulation of the air. To clean the nozzles, please follow the next stages :
ère
1
Stage :
Switch off the whirlpool option and empty the bath.
ème
Stage :
2 Use a flat screwdriver to remove the air jet cap.
ème
Stage :
3 Clean the chromed air jet cap, the nozzle and the ball.
Then reposition the air jet cap on the nozzle.
ème
Stage :
4 . Press on the chromed cap right down. Check that it is
correctly positioned on the nozzle. Switch on the bath and the whirlpool system to check they are working properly.
Page 9/10
A4AN7440UK.doc
MAINTENANCE FORM (LOGBOOK):
Agent
signature)
(name and
Corrections
Observations
Tests
Hi/Lo tub
Safety parts
date
Control
A4AN7440UK.doc
Page 10/10
Loading...