Respironics Inspiration Elite Instructions Manual

Page 1
InspirationElite
Envisioning to morrow. Improvin g today.
SM
• English • Español • Português •
Ελληνικά
• Türkçe •
Български
• Magyar • Română • Čeština
• Slovensky • Slovenščina •
Русский
Inspiration Elite Nebulizer Compressor System INSTRUCTIONS Sistema compresor nebulizador Inspiration Elite INSTRUCCIONES INSTRUÇÕES do Sistema de Nebulizador com Compressor Inspiration Elite
ΟΔΗΓΙΕΣ για το σύστημα εκνεφωτή με συμπιεστή Inspiration Elite
Inspiration Elite Nebulizatör Kompresör Sistemi TALİMATLAR
ИНСТРУКЦИИ за работа с пулверизиращата компресорна система Inspiration Elite
Inspiration Elite kompresszoros porlasztórendszer ÚTMUTATÓ INSTRUC
Ţ
IUNI Sistem de comprimare şi nebulizare Inspiration Elite
NÁVOD pro kompresorový nebuliza
č
ní systém Inspiration Elite NÁVOD NA POUŽITIE rozprašovacieho kompresorového systému Inspiration Elite NAVODILA za sistem kompresorja in nebulizatorja Inspiration Elite
Аэрозольный аппарат
Inspiration Elite
с компрессором ИНСТРУКЦИИ
www.respironics.com
© 2009 Respironics, Inc. and its affiliates. ALL RIGHTS RESERVED Respironics and Inspiration Elite are trademarks of Respironics Inc. or companies within the group respectively, registered in the UK and other countries.
1054391 REV 2 11/09 bdc 12049
Made in China
Respironics New Jersey, Inc.
5 Wood Hollow Road Parsippany, New Jersey 07054 USA Tel: +1-724-387-4000 Fax: +1-724-387-5270
Respironics Deutschland GMBH
Gewerbestrasse 17 D-82211 Herrsching Germany Tel: +49 815293060 Fax: +49 8152930618
Respironics (UK) Ltd
Chichester Business Park City Fields Way, Tangmere, Chichester, West Sussex PO20 2FT UK Tel: +44 (0) 800 1300 845 Fax: +44 (0) 800 1300 846
12049_RIUK_InspirationEliteInstCOVER_SEUROPE_1054391_REV2_v1.indd 1 26/10/09 15:32:35
Page 2
Inspiration Elite nebulizer compressor system
Inspiration Elite Nebulizer Compressor System (A)
3
Parts of the system (B)
3
Unpacking your Inspiration Elite system
5
Important safeguards
5
How to use your Inspiration Elite
6
Care and cleaning
6
Glossary of symbols
6
Technical information
7
Warranty
7
Contents
Diagram A shows the Inspiration Elite.
Mouthpiece A1
Sidestream drug container A2
Nebulizer tubing A3
On/off switch A4
Air flow outlet A5
Air vents A6
Air inlet filter A7
Inspiration Elite Nebulizer Compressor System
Inspiration Elite is an electrical mains powered air compressor nebulizer system intended to provide a source of compressed air for medical purposes for use in home healthcare. It is to be used with a pneumatic nebulizer to produce aerosol particles of medication for respiratory therapy for both children and adults.
Diagram B shows the parts included with the system.
Sidestream drug container B1
Tubing B2
Mouthpiece B3
Child mask B4
Adult mask B5
Air inlet filters B6
Parts of the system
EN
ENGLISH
4
Inner back page
3
A3
A5
A7
B1
B2
B3
B4
B5
B6
A1
A B
A2
InspirationElite
A6
A4
12049_RIUK_InspirationEliteInstCOVER_SEUROPE_1054391_REV2_v1.indd 2 26/10/09 15:32:35
Page 3
EN
ENGLISH
5
Important safeguardsUnpacking your
Inspiration Elite system
When you unpack your Inspiration Elite from its shipping carton:
lSave the shipping carton.
lMake sure you have all the content items listed
and that they are not damaged.
l Report anything missing or damaged to
Respironics.
Do not install, maintain or operate this equipment without first reading and understanding these instructions for use.
If you are unable to understand any portion of these instructions, contact your healthcare provider or call Respironics Customer Service on:
+44 (0) 800 1300 845
Customer Service UK
+61 (02) 9666 4444
or (toll free) 1300 766 488 Customer Service Australia
+49 815293060
Customer Service Germany
+1-724-387-4000
or (toll free) +1-800-345-6443 Customer Service USA
When using electrical products, especially when children are present, safety precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING.
CAUTION! To reduce the risk of electrocution:
lAlways unplug this product immediately after using. lDo not place or store product where it can fall or be pulled into a bath or sink. lDo not place in or drop into water or other liquid. lDo not reach for product that has fallen into water. Unplug immediately.
CAUTION! To reduce the risk of burns, electrocution, fire or injury to persons:
lThis device should only be used on the advice of a physician. lThis product should never be left unattended when plugged in. lClose supervision is necessary when this product is used by, on, or near children or
physically challenged individuals.
l Use this product only for its intended use as described in this manual. Do not use attachments not
recommended by the manufacturer.
l Never operate this product if it has a damaged power cord or plug, if it is not working properly, if it has
been dropped or damaged, or dropped into water. Return the product to a service centre for examination and repair.
lKeep the power cord away from heated surfaces. lNever block the air opening of this product or place it on a soft surface, such as a
bed or couch, where the air openings may be blocked. Keep the air openings clear of dust, lint or hair.
lNever use while sleeping or drowsy. lNever drop or insert any object into any openings. lDo not use outdoors or operate where aerosol (spray) products are being used or
where oxygen is being administered in a closed area such as an oxygen tent.
lDo not use compressor and nebulizer separately. lTo reduce risk of electric shock, DO NOT DISASSEMBLE. lDO NOT MODIFY THIS PRODUCT.
12049_RIUK_InspirationEliteInstPAGES_SEUROPE_1054391_REV2_v1.indd 1 26/10/09 15:33:19
Page 4
EN
ENGLISH
6
Check the medication nebulizer cup for damage. (The nebulizer cup enclosed with your Inspiration Elite should be replaced regularly. Ask your healthcare provider for replacement guidelines and supplies).
Place your Inspiration Elite unit on a firm, flat surface near an electrical outlet and in an area where you can be seated comfortably during your treatment.
Plug the power cord into the electrical socket.
Do not operate the unit without the filter or with a clogged (dirty) filter. Operating the unit with a dirty filter can impair proper operation and cause damage that is not covered by the warranty.
Wash your hands before preparing your medication.
Assemble your nebulizer cup and add your prescribed medicine following your prescription and the separate nebulizer instructions.
Connect one end of the tubing to the bottom of the cup and the other end of the tubing to the air outlet on the unit.
Turn the power switch on (I) to begin your treatment.
When your treatment is complete, turn the power switch off (O) and unplug the unit.
Clean the medication nebulizer cup according to its instructions.
1
2
3
How to use your Inspiration Elite
4
Care and cleaning
5
6
7
8
9
10
lUnplug the unit before cleaning. lUse a damp cloth to wipe down the outside of the
compressor at least once each month (or more if necessary).
l Check the filter at least once each week. Replace
the filter when dirty. Replacement filters are available where you purchased this product.
lPack of 4: Part No. 1054388
lTo change the filter:
lLift up the filter and remove it by twisting and
pulling it straight up.
l The filter should be replaced when it becomes
discoloured. Do not wash or reuse the filter.
l After each cleaning, check that the unit is working
properly by verifying that air still comes out of the nozzle when the unit is turned to the ON position.
lThe unit is oil-free. Do not lubricate. lService should only be performed by an authorised
dealer. Unauthorised repair voids warranty.
KEEP THESE INSTRUCTIONS FOR FUTURE USE
Glossary of symbols
Caution: check the operating instructions
Follow operating instructions
~ Alternating current
RH Relative humidity
P Atmospheric pressure
I/O Switch ON/Switch OFF
Class II unit
Type B
Temperature limitations
Separate collection
0123
This device meets 93/42/EEC directive.
12049_RIUK_InspirationEliteInstPAGES_SEUROPE_1054391_REV2_v1.indd 2 26/10/09 15:33:19
Page 5
EN
ENGLISH
7
Technical information
MODEL
INSPIRATION ELITE
VOLTAGE 230V @ 50Hz, 0.55A AVERAGE POWER 50 W THERMAL OVERLOAD PROTECTOR Rating 150°C PLUG Euro 2 round pin plug FUSE 2.5amp, Slow blow fuse WEIGHT 1.5 kg DIMENSIONS (MAIN UNIT) 14 cm (W) x 9 cm (H) x 19 cm (D) MODE OF OPERATION 30 minutes ON/ 30 minutes OFF MAX A-WEIGHTED SOUND PRESSURE LEVEL 60dBA
PERFORMANCE
AVERAGE FLOW 5.4 SLPM @10 PSI (68.9 kPa) MAXIMUM PRESSURE 33.4 PSI (230 kPa) AVERAGE NEBULIZATION RATE 0.30 ml/min. PARTICLE SIZE Dv(50) 3.17µm
OPERATING CONDITIONS
TEMPERATURE 10°C to 35°C (50°F to 104°F) AIR HUMIDITY 10% RH to 95% RH OPERATING PRESSURE 9.8 PSI (68 kPa)
STORAGE/TRANSPORT CONDITIONS
TEMPERATURE -25°C to 70°C (-13°F to 158°F) AIR HUMIDITY 10% RH to 95% RH ATMOSPHERIC PRESSURE 700 to 1060 hPa
Nebulization rate and particle size is based on the SideStream handset, using saline.
Warranty
Respironics, Inc. warrants the Inspiration Elite compressor to be free from defects in materials and workmanship under normal use and operation for a period of 3 years from date of purchase from Respironics, Inc. The warranty is limited to repair or replacement, at Respironics, Inc.’s sole option, of any such component or equipment claimed to be defective when claim is shown to be bona fide by evaluation by Respironics, Inc. This warranty does not extend to any components or equipment subjected to misuse, improper operation, accidental damage, or unauthorised repairs, and is not extended to charges of, or for, labour repairs. All items returned must be properly packaged and shipped, prepaid, by the distributor servicing the unit. Respironics, Inc. shall not be liable to purchaser or others for loss of use of equipment or for indirect, or incidental or consequential damages that might arise.
CERTIFICATION
Electric Safety Standards EN60601-1. Respiratory therapy equipment. Nebulizing systems and their components EN13544-1. Electromagnetic Compatibility according to EN60601-1-2.
12049_RIUK_InspirationEliteInstPAGES_SEUROPE_1054391_REV2_v1.indd 3 26/10/09 15:33:19