RE636 Wireless Outdoor Siren Strobe
Connect+™ Encrypted
The RE636 Wireless Outdoor Siren Strobe is an auditory
warning device that produces high volume warning sounds and
visual strobing.
Features
• Multi-cadence siren
• 100 dBA minimum at 1m
• 2-5 year battery life (batteries included) or AC powered
(RE012-17 sold separately)
• 5-year warranty
Sounds a high volume warning for burglary, smoke and carbon
monoxide alarm conditions. Volume is adjustable through the
Connect+ Installer application, or through the interactive service
provider’s web portal.
Enroll by placing the panel and siren into wireless enrollment
mode. The siren’s PWR and RF LEDs will blink back and forth
when in enrollment mode. If the siren has never been enrolled,
enrollment mode will start automatically when opening the
cover. To overwrite a previously enrolled ID, power up the
device while holding the tamper. When the red RF LED
illuminates, release the tamper switch. After enrolling the siren,
take the panel out of wireless enrollment mode.
• Once the siren is properly enrolled, test functionality in a
desired location.
• The panel supports up to eight RE636 sirens at one time.
Mounting Holes
A
T
S
L
L
N
I
G
E
U
D
I
Replace batteries by opening the cover and removing the inner
cover to gain access to the 3 C-cell batteries.
• To remove inner cover, push down the two latches, then
pull out the clear inner cover.
Mounting can be done by securing the siren to a surface with the
mounting screws (included) at the three slotted mounting holes.
Ensure arrows inside are pointed up.
Pro Tips
• Cover can hang from bottom of enclosure and inner cover can
clip into cover for convenience while work is being done inside
enclosure.
• To change the strobe lens, unscrew the cover screw until it
is past the lens, and then push on the corner of the lens to
loosen and remove. Select desired color.
• Power (PWR) LED will turn on when the siren is awake (every
18 seconds on battery and always when powered from wall).
• RF LED will blink when a packet is received.
• Enroll packets are automatically sent every 18 seconds when
in enroll mode. Pressing or releasing the tamper switch while
sensor is in enroll mode will send another enroll packet.
Use the panel installation guide to verify proper system setup.
Inner cover
removal
latches

Specications
Physical
Housing Dimensions
Weight with Batteries
Mounting Hardware
Environmental
Operating Temperature
Maximum Humidity
Sensor Specications
Frequency
Replacement Battery
Battery Life
Battery Voltage
Current Draw
Sounder Loudness
Wall Connection (Optional)
Transmitted Indications
Certication
RE636 FCC, IC
Specications subject to change without notice
12.0 x 11.2 x 2.2 inches (30.5 x 28.4 x 5.6 centimeters)
2.6 pounds (41.6 ounces)
3 Stainless Steel Mounting Screws
0°F to 130°F (-18°C to 55°C)
85% non-condensing relative humidity
433 MHz
3 Energizer® C-Cell Batteries
2-5 years, non rechargeable
4.5 VDC (nominal)
4uA (Sleep), 16mA (AC Power), 1.05A (Alarm)
100 dBA, minimum at 1m
US 2-prong electrical outlet blades (RE012-17)
Low Battery, Supervisions, Cover Tamper, Wall Tamper
AC/NZS 60950-1:2015
ETSI EN 300 220-2 V2.4.1 / AS/NZS 4268:2012
ETSI EN 301 489-1 V1.9.2
ETSI EN 301 489-3 V1.6.1
WARRANTY
Alula will replace all non-portable products that are defective in
their rst ve (5) years, and all portable products that are defective
in their rst two (2) years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE636
47-0063-00 • REV A • 2019-05-30
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE636
TRADEMARKS
Alula and Connect+ are trademarks owned by Alula Holdings, LLC.
Energizer is a registered trademark owned by Energizer Brands, LLC.