
Wireless
Security
Solutions
RE352 DSC-Compatible PINpad™
Features
• Secure, 4-digit Code to disarm
• 1-button arming
• Red/Green LED arming feedback
• Small, yet comfortable keypad
• Mounts on wall via VHB® tape, or screws
• Secure for carrying in purse or mounting on car visor
• Strong, reliable RF signal.
• 4-6 year battery life on CR2032 battery.
Key Instructions
• Enroll as a Key Fob.
• Code programming
• Enrolling:
Operation
Default access code is “1234”.
To change access code:
1. Enter current 4-digit access code.
2. Within 4 seconds, press and hold the “1” and “3” keys
simultaneously. After 3 seconds, Red LED will be lit.
3. Enter new 4-digit access code. After successfully changing
the code, the Green LED will be lit
4. Note new access code . BAD GUY CANNOT RESET CODE.
So it must be noted and remembered!
1. Refer to the DSC control unit installation manual.
2. If panel is capable of Wireless Enrollment Mode, put the
control panel in that mode and both the STAY or AWAY
buttons for 3 seconds.
Or, put panel in Serial Number Entry Mode and program in
the printed ESN.
3. Set up as you would a WS4939 4-Button Fob.
Button
Stay ARM STAY flashes double red
Away ARM AWAY flashes double red twice
PIN Code DISARM flashes double green
Stay + Away PANIC ALARM flashes red 8 times
Panel Action LED
Pictures
Status LED
Shows command sent
Battery Replacement
Screwdriver here
to open
Current 4-digit access code, and then…
1 + 3 Red LED,and then…
Enter New Code
=
Panic (Enroll)
+ Terminal up
RE352_DSC-Compat_PIN-Pad.doc Page 1 of 3 29-May-13
www.ResolutionProducts.com
RE352_DSC-Compat_PIN-Pad.doc Page 2 of 3 29-May-13
www.ResolutionProducts.com

Specifications
Secure replacement to a DSC WS4939 4-Button Key Fob.
Not supervised.
Replacement Battery: CR2032 Lithium / Manganese Dioxide
Temperature Range: 0F to 120F
Housing dimensions: 2x2.25x0.33 inches
1-way RF: Does not receive panel status
Specifications subject to change without notice.
Notices
“GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric
Company, Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies
Inc., and NAPCO Security Systems, Inc., respectively.
Resolution Products, Inc. products will function with one of either GE, Honeywell, DSC or
Napco systems. However, no Resolution product is produced by, endorsed by, nor is officially
associated with GE, Honeywell, DSC or Napco. Resolution recommends verifying proper
enrollment and operation, per control panel installation instructions, at installation.
Warranty
Resolution Products, Inc. will replace products that are defective in their first year.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could
void the user's authority to operate this equipment.
FCC ID: U5X-RE352
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may
cause undesired operation of the device.
Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence.
Son fonctionnement est soumis aux deux conditions suivantes:
1. Ce dispositif ne peut causer des interférences, et
2. Ce dispositif doit accepter toute interférence, y compris les interférences
qui peuvent causer un mauvais fonctionnement du dispositif.
IC: 8310A-RE352
RE352_DSC-Compat_PIN-Pad.doc Page 3 of 3 29-May-13
www.ResolutionProducts.com