RE108 Hardwire to Wireless Takeover Translator, GE-Compatible
Features
• Converts hardwire zones into GE-compatible wireless signals.
• 8 Hardwire loops with end-of-line resistor detection.
• Unique wireless ID (or loop) for each zone, plus 1 for main device.
• Transmit diversity for long reliable range.
• PIR powering (via external supply).
• Back-up battery operation.
• Complete supervision of tampers, external power supply fault and low
battery.
Key Instructions
• Use with normally closed contacts in-line with 4.7 K-ohms end-of-line
resistors.
• 4-wire PIRs only.
• External supply: 7-14V AC or DC at least 50 mA.
• PIR usage: Adds requirements to external supply – see Specifications.
• 2 AAA Alkaline batteries are for backup in case of external supply
failure. Backup batteries cannot drive the PIR.
• Enrolling:
Loops enrolled by tampering (shorting).
Main device enrolled by tamper switch on the board.
Operation
• 8 Hardwire Zones wireless transmissions (8 unique IDs):
Alarm, when Device sees open circuit.
Tamper, when device sees short circuit.
Supervisories, every hour for each zone.
• Translator Main Zone wireless transmission (9
Tamper, when cover opened.
Low battery, when either low AAA batteries, OR loss of AC.
Supervisory every hour.
• LED Operation
Green LED: On if AC power present.
Red LED: On if device tamper or device low battery
th
unique ID):
RE108_Hardwire_to_GE-Compat_Translator.doc
Page 1 of 3 21-Sep-09
www.ResolutionProducts.com

Specifications
GE Device Type: 10 (all 8 zone ID’s and device ID)
Zone sensing duration: State sensed if held more than 600ms.
End-of-line Resistors: 4.7k-ohm, 5%.
Max wire run: 1000 feet
Backup batteries: Two AAA Alkaline.
External supply: 7-14V AC or DC, at least 50mA.
Current draw with supply: 4mA, normal operation.
PIR usage: Supply must be DC only. PIR may need tighter
AC Fail Conditions: AC gone for 15 minutes. Restores on AC
Device Low Battery Conditions: Low battery for 1 minute. Restores on
Back-up Battery Life on AC Fail: 2 years, all zones terminated in 4.7K;
Housing dimensions: 4x6x1 inches
Specifications subject to change without notice.
Internal Picture
voltage tolerance. Add PIR and device
current requirements together to get total
current need.
restore.
device tamper, AC restore.
longer if unused/open.