Outdoor Door/Window Sensor
Resolution Compatibles
Outdoor Door/Window Sensor is a full-featured security
transmitter with industry-leading wireless range and battery
life. It is designed to sense the opening and closing of
gates, sheds, and other outdoor open/close applications.
An alarm signal will be transmitted when the magnet is
pulled away from the sensor, or when an external contact is
opened.
Features
• Industry-leading wireless range and battery life
• Wide magnetic gap distance
• Two built-in external contact zones
• Secure encrypted wireless transmissions
• IP67 waterproof enclosure rating
• 5-year warranty
Enroll by placing the panel into wireless enrollment mode
and transmitting an enrollment signal from the sensor.
Interlogix, Qolsys, DSC, and Cryptix sensors can be
enrolled by pulling the battery tab or tampering the unit.
Honeywell and 2GIG sensors can be enrolled by tripping
the unit 3 times or holding the tamper and powering
up the device by pulling the battery tab. Honeywell
and 2GIG sensors must be enrolled as Loop 2 sensors.
Alternatively, all sensors can be enrolled by manually
entering the sensors serial number.
N
I
G
Mounting Screw Holes
Magnet
A
T
S
L
L
E
U
D
I
Enrollment Signal
• Interlogix External 2
• Power up the sensor while holding the tamper
• Honeywell & 2GIG External 1 & 2
• Should be enrolled as Loop 1 and Loop 3,
respectively. Enroll each external by tripping 3
times
• DSC Externals
• Trip desired external to enroll
Install by rst attaching the mounting plate and magnet to a
door, window, or fence using screws (provided) or cable ties
(not provided).
Mounting Tips
• Face of mounting plate marked “Flat Mount” is to be
mounted against at surfaces (e.g. square wood post).
• Face of mounting plate marked “Pole Mount” is to be
mounted against round surfaces (e.g. fence post).
Use the panel installation guide to verify proper system setup.
Alignment Marks
Cover-Securing Screw Hole

Make sure to align the alignment marks on the sensor and magnet
when mounting. Finish by latching the sensor to the mounting
plate and tightening the cover-securing screw to secure the sensor
in place.
Removal Tamper is implemented by screwing the provided
screw with rubber washer through the removal tamper screw
hole in the base and into the mounting surface. Remove the
battery for access to the removal tamper screw hole.
External Contacts can be installed by routing the wires through
the back of the enclosure. A thinned area in the enclosure must be
punched out with a screwdriver to allow the wires through. After
routing and connecting the wires, reseal the hole with silicone
• Use normally-closed contacts because the sensor will
transmit a signal when it sees an external contact open.
• Do not use End-of-Line Resistors.
• Wire the contact to one or both outside terminals using
the center terminal as common.
Removal tamper
screw hole
Thinned area for external
contact wires
Battery
Reed Switch
Pro Tips
Metal installs should include pre-drilling holes before using
screws to secure the mounting plate and magnet.
Wireless performance is optimized when mounted near the top
of the gate or door in a vertical orientation.
External 2
Common
External 1