Resolution CryptiX RE601 Installation Manual

Page 1
RE601_Cryptix-Compat_DWS_Instructions
24-Hour Tech Support Line: (715)808-0164
26-Feb-15
www.ResolutionProducts.com
Installation Guide RE601 CryptiX™-Compatible Standard Door / Window
Features
For sensing things that open or separate
Strong, reliable RF signal
10-15 year battery life
Cover tamper
Low Battery indication
3 total zones
Main reed switch + magnet
2 Optional External Contacts
Enrollment
Place panel in enrollment mode.
Sensor enrollment signal can be sent by one of these two ways.
Remove the battery tab.
Pull cover off to tamper device.
To set up zone and configure the sensor, log into the web based dealer portal
Installation
Place sensor on a door or window using the mounting holes.
Below are recommendations for sensor locations.
Mounting
holes
RE601_Cryptix-Compat_DWS_Instructions
24-Hour Tech Support Line: (715)808-0164
26-Feb-15
www.ResolutionProducts.com
Mount the sensor with magnet on the side of the sensor with the mark as pictured below.
Optional External Contact Mounting and Wiring
Optional External contact wiring.
External Input #1: Outer Terminal Zone + Center Common Terminal
External Input #2: Inner Terminal Zone + Center Common Terminal
Optional external contact zones are: normally closed – alarm on open.
No end-of-line resistors on external contact zones.
Note: External contacts not evaluated by ETL
Outer Terminal Zone
External Input #1
Center Common Terminal
Inner Terminal Zone
External Input #2
Magnet rests in
drilled hole on top of door.
E
xternal contact is
wired to the door window sensor through a hole drilled in the doorframe
Magnet Mark
Page 2
RE601_Cryptix-Compat_DWS_Instructions
24-Hour Tech Support Line: (715)808-0164
26-Feb-15
www.ResolutionProducts.com
Operation
Reed switch or optional external contact Alarm, when…
…magnet is pulled away from reed switch or
…external contact is opened Tamper, when cover is opened Supervisories, every hour
Specifications
Specifications subject to change without notice.
RE601_Cryptix-Compat_DWS_Instructions
24-Hour Tech Support Line: (715)808-0164
26-Feb-15
www.ResolutionProducts.com
Notices
Warranty Resolution Products, Inc. will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment.
FCC ID: U5X-RE301
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1)This device may not cause interference, and (2)This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)l'appareil ne doit pas produire de brouillage, et (2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE301
Manual: 47-0004-08 REV A