Resol GA3 User Manual

GA3
Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this unit.
Manual
www.resol.de
RESOL Large Display GA3
*48003860*
Large Display GA3
© RESOL 08179 GA3.monus.indd
| 2
Table of contents
Safety advice .............................................................................................2
Technical data and overview of functions .............................................. 3
1. Installation ...........................................................................................3
1.1 Mounting ..........................................................................................................3
1.2 Electrical connection .....................................................................................4
2. Commissioning ................................................................................... 3
2.1 Connection to the RESOL VBus
®
...............................................................4
3. Displays ................................................................................................ 4
Imprint ...................................................................................................4
Technical data Housing: High-grade steel frame with multiplex-wood elements Dimensions: 530 x 630 x 100 mm Protection type: IP30 (suitable for dry interior
locations)
Display: numerical 7-segment LED display Segment size: 45 x 26 mm, 10°- digit inclination Ambient temperature: 32 ... 104 °F Alimentation:
110 ... 240V~ (via mains adapter, included in delivery scope)
Power consumption: max. 9 VA Bus connection: RESOL VBus
®
Safety advice
Please pay attention to the following safety advice in order to avoid danger and damage to people and property.
Regulations
Attention should be paid to
- the statutory provisions for pre­vention of industrial accidents,
- the statutory provisions for envi­ronmental protection,
- the Health and Safety at Work Act 1974, - Part P of the Building Regu­lations 2005,
- BS7671 Requirements for electri­cal installations and relevant safety regulations of DIN, EN and VDE
These instructions are exclusively ad-
dressed to authorised skilled personnel.
- Only qualified electricians should carry out electrical works.
- Initial installation must be effected by qualified personnel named by the manufacturer.
Appropriate Usage
The large display GA3 may only be used for visualising the data issued by the controller in solar thermal systems in compliance with the technical data specified in this manual.
Improper use excludes all liability claims.
Declaration of conformity
We, RESOL Elektronische Regelungen GmbH, D-45527 Hattingen, declare under our sole responsibility that our product GA3 complies with the following standards:
EN 55 014-1 EN 60 730-1 According to the regulations of the above directives, the product is labelled with
:
89/336/EWG 73/ 23/EWG Hattingen, 13. June 2007 RESOL - Elektronische Regelungen GmbH
ppa. Gerald Neuse
Subject to changes without prior notice. Errors excepted.
Large Display GA3
© RESOL 08179 GA3.monus.indd
3 |
100
530,6
400
20
Ø14
Ø6
65,3
9V
• Visualisationofcollectorandstoretemperatureas
well as of heat quantity
• one6-digitandtwo4-digit7-segmentLEDdisplays
• easyconnectionviaRESOLVBus
®
• anti-reectivewindow
• powersupplyviamainsadapter
• automaticcontrollerrecognition
The RESOL Large display GA3 is designed for simple con­nection to RESOL controllers via the RESOL VBus
®
. It is used for visualising the data issued by the controller: collec­tor and store temperature as well as heat quantity produced in the solar system.
The use of high-efficient LEDs and antireflective filter glass assures a high optical brilliance and good readability - even in poor lighting conditions and at a larger distance.
1. Installation
The device must only be located in dr y interior rooms. It is not suitable for installa-
1.1 Mounting
There are two fastening holes at the rear side of the GA3 by means of which the GA3 can be attached to a corresponding wall mounting device.
Please make sure that the wall mounting device is correctly fastened to the wall (screws, nails, etc.) in order to prevent damage.
Please pay attention to the valid local regulations when mounting the device.
tion in hazardous locations and should be protected from electromagnetic fields!
1.2 Electrical connection
First of all, connect the enclosed 9V-mains adapter to the mains terminals of the GA3 (9V DC, see bottom side), and then to the mains!
Mains connection
2. Commissioning
The large display GA3 as well as further VBus®-modules can be connected to the RESOL VBus® in parallel. The bus cable can be extended with a two-wire cable (bell wire). The cable carries low voltage and must not run together in a cable conduit with cables carrying a voltage higher than 50 V (please pay attention to the valid local regulations such as VDE regulations for Germany). The cross section must be at least 0,5 mm2 and the cable can be extended to up to 50 m in the case of a single connection.
Large Display GA3
© RESOL 08179 GA3.monus.indd
| 4
Collector temperature in °F
Store temperature in °F
Energy yield in kWh.
Note: If no indication is shown in the display, please
check the connection at the VBus
®
terminals.
2.1. ConnectiontotheRESOLVBus
®
Connect the enclosed connection cable of the GA3 (accessory
bag) with the stripped ends and either polarity to the VBus®-
terminals.
Connect the cinch plug of the cable to the upper or lower
cinch socket (parallel connection) of the GA3.
During commissioning, the GA3 is in an initialisation phase.
The controller is automatically recognized.
Afterwards, the GA3 is ready for use.
12
S1 S2 S3
3456
Temp.Sensor
Pt1000
LNR1NR2N
201918171615
S4
78
141312
VBus
910
1 (1)A (1220 ...240) V~
(1)A (220 ... 240)V~
R1 R2
T4A
220 ...240 V~
Example: Connection to the DeltaSol® BS Plus
3. Displays
Distributed by:
RESOL-ElektronischeRegelungenGmbH
Heiskampstraße 10
45527 Hattingen / Germany
Tel.: +49 (0) 23 24 / 96 48 - 0
Fax: +49 (0) 23 24 / 96 48 - 755
www.resol.de
info@resol.de
Important notice
We took a lot of care with the text and drawings of this manualand to the best of our knowledge and consent. As faults can never be excluded, please note:
Your own calculations and plans, under consideration of the current standards and directives should only be basis for your projects. We do not offer a guarantee for the completeness of the drawings and texts of this manual - they only represent some examples They can only be used at your own risk. No liability is assumed for incorrect, incomplete or false information and / or the resulting damages.
Please note
The design and the specifications are to be changed without prior notice
The illustrations may differ from the original product.
Imprint