ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia
ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA
ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshire OX14 4RY UK
ResMed Offices Australia, Austria, Belgium, Brazil, China, Finland, France, Germany, Greece, Hong Kong, India, Ireland, Italy, Japan, Malaysia, Mexico,
Netherlands, New Zealand, Norway, Portugal, Singapore, South Africa, Spain, Sweden, Switzerland, UK, USA (see www.resmed.com for contact details).
Protected by patents: AU 691200, AU 697652, AU 709279, AU 724589, AU 730844, AU 736723, AU 750095, AU 750761, AU 764761, AU 779327, AU
2002231456, CN 02804930.6, EP 0651971, EP 0661071, EP 0920845, EP 0934723, EP 1028769, EP 1126893, EP 1502618, EP 1144036, JP 3580776, JP
3778797, NZ 504595, US 5199424, US 5245995, US 5522382, US 5704345, US 6029665, US 6138675, US 6240921, US 6363933, US 6367474, US 6425395,
US 6502572, US 6591834, US 6705315, US 6745768, US 6817361, US 6988498, US 7040317, US 7100608. Other patents pending.
Protected by design registrations: AU 302180, AU 302181, AU 302182, AU 302183, AU 302184, AU 302185, AU 302186, CN 200430121212.2, CN
200430121213.7, CN 200430121211.8, CN 200430121214.1, CN 200430121215.6, CN 200430121216.0, CN 200430121217.5, EU 269436, EU 815071, HK
0412901.9, JP 1257662, JP 1257663, JP 1266956, JP 1266957, JP 1267270, JP 1267271, NZ 405614, NZ 406923, NZ 406924, NZ 406925, NZ 406926, NZ
406927, NZ 406928, US D544598, US D553228, US D557406, US D557407, US D560795, US D561891, US D565160. Others pending.
S8, S8 AutoSet, S8 Elite and SmartStart are trademarks of ResMed Ltd and AutoSet and HumidAire are registered in U.S. Patent and Trademark Office.
The S8 AutoSet Spirit II self-adjusting sleep apnea system is indicated for the treatment
of obstructive sleep apnoea (OSA) in adult patients. The S8 AutoSet Spirit II selfadjusting sleep apnoea system has two treatment modes: AutoSet and fixed-pressure
CPAP. The S8 AutoSet Spirit II
S8 AutoScore II
TheS8 AutoScore II continuous positive airway pressure (CPAP) system is indicated for
the treatment of obstructive sleep apnoea (OSA) in adult patients. The S8 AutoScore II
CPAP system is intended for home and hospital use.
Contraindications
Your S8 Series II is not a life-support device and may stop operating during power
failure or certain fault conditions. It should not be used by patients who are dependent
on continuous therapy.
Positive airway pressure therapy may be contraindicated in some patients with the
following pre-existing conditions:
• severe bullous lung disease
• pneumothorax
• pathologically low blood pressure
• dehydration
• cerebrospinal fluid leak, recent cranial surgery, or trauma.
Adverse Effects
Patients should report unusual chest pain, severe headache, or increased
breathlessness to their prescribing physician. An acute upper respiratory tract infection
may require temporary discontinuation of treatment.
The following side effects may arise during the course of therapy with the CPAP device:
• drying of the nose, mouth, or throat
• nosebleed
• bloating
• ear or sinus discomfort
• eye irritation
• skin rashes
• chest discomfort.
system is intended for home and hospital use.
1Introduction
Parts of the S8 Series II system
Carry handle
Screen
Keypad
Air outlet
DC
AC
Data Card
slot
Your S8 Series II device comprises:
• S8 Series II device
• Power cord
• Carry bag
• 2 m air tubing.
Optional components include:
• Integrated humidifier
• Front cap
• 3 m air tubing
• DC-12 converter
• ResMed Tubing Wrap.
Masks
A list of masks (and their settings) compatible with these devices can be found on
www.resmed.com, on the Products page under Service and Support.
Humidifiers
A list of humidifiers compatible with ResMed devices can be found on
www.resmed.com, on the Products page under Service and Support.
ResScan Data Card
The ResScan Data Card may be used with the S8 Series II either to help your clinician
monitor your treatment or provide you with updates to your device settings.
2
Using the S8 Series II
!
!
Setting Up
1 Connect the power cord to the socket at the rear of the S8 Series II device.
2 Plug the other end of the power cord into the power outlet.
3 Connect one end of the air tubing firmly onto the air outlet.
4 Connect the assembled mask system to the free end of air tubing.
For information on assembling your mask, see your mask manual.
2
1
3
4
WARNING
• Make sure the power cord and plug are in good condition and the
equipment is not damaged.
• Only ResMed air tubing should be used with the device. A different type
of air tubing may alter the pressure you actually receive, reducing the
effectiveness of your treatment.
• Blocking the hose and/or air inlet of the device while in operation could
lead to overheating of the device.
CAUTION
• Be careful not to place the device where it can be bumped or where
someone is likely to trip over the power cord.
• If you put the device on the floor, make sure the area is free from dust
and clear of bedding, clothes or other objects that could block the air
inlet.
• Make sure the area around the device is dry and clean.
3Using the S8 Series II
How to Use the Control Panel
LCD screen
Start/Stop key
Keypad
The control panel of the S8 Series II includes an LCD screen which displays the
menus and treatment screens as well as a keypad for navigating through the
menus and delivering treatment.
The S8 Series II keypad has the following keys:
KeyFunction
Start/Stop
Starts or stops treatment.
Up
Down
Left
Right
The keypad and LCD are equipped with backlights that come on when the device
is powered. The LCD backlight turns off after two minutes of inactivity, and
comes back on when you press a key. The keypad backlight is always on while
the S8 Series II is on.
Allows you to increase settings options and scroll through
the S8 Series II menu.
Allows you to decrease settings options and scroll through
the S8 Series II menu.
Performs the function indicated by the guiding text
displayed above it on the LCD screen (eg, change).
Performs the function indicated by the guiding text
displayed above it on the LCD screen (eg, exit)
.
Selecting the Mask Type
To ensure your device functions as intended with your selected mask, you need to
select the mask type that you are using.
1 With the RAMP or SETTLING screen displayed, press . (In CPAP mode, the
standby screen displays RAMP. In AutoSet mode (S8 AutoSet Spirit II only) the
standby screen displays SETTLING.)
Press until MASK is displayed.
2
Press to change the setting.
3
4
Press or until you see the setting that you require.
!
MASK FIT:
*****
excelnt
4
Press to apply.
5
Using the Mask-fitting Feature
You can use the S8 Series II mask-fitting feature to help you fit your mask properly. This
feature delivers air pressure for a three-minute period, prior to starting treatment,
during which you can check and adjust your mask fit to minimise leaks.
Note: Make sure that the mask setting on the MASK screen is the same as the mask
you are using.
1 Fit your mask as described in the mask user instructions.
2 With the RAMP or SETTLING screens displayed, hold down for at least
three seconds until air pressure delivery starts.
Your device will ramp to the mask-fit pressure and will remain at this pressure
for three minutes.
The following displays on the LCD screen indicating that the mask-fitting feature
is operating, where: ***** is an excellent fit;****- is a very good fit; ***-- is a
good fit; while **---, *---- and ----- each require you to adjust your mask.
3 Adjust your mask, mask cushion and headgear until you have a secure and
comfortable fit.
After three minutes, the pressure reverts to the set pressure and treatment will
begin. If you do not wish to wait three minutes, hold down for at least
three seconds to start treatment immediately.
If you press for less than three seconds, the unit will return to standby
mode (the RAMP or SETTLING screen).
Starting Treatment
1 Make sure the power is on.
The product name is displayed briefly on the screen, then the standby screen
displays RAMP (or SETTLING). The key and LCD backlights also turn on.
Lie down and arrange the air tubing so that it is free to move if you turn in your
2
sleep.
CAUTION
Do not leave long lengths of air tubing around the top of your bed. They could
twist around your head or neck while you are sleeping.
Alter the ramp or settling time if required.