ResMed 1 h4i, 248672, 248672/1 User Manual

H4i
HEATED HUMIDIFIER
User Guide
English
H4i™
HEATED HUMIDIFIER
User Guide
English
Manufacturer:
ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia.
Distributed by:
ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK.
See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip.
H4i, S8, Stellar and VPAP are trademarks of ResMed Ltd. Stellar and VPAP are registered in U.S. Patent and Trademark Office.
© 2013 ResMed Ltd. 248672/1 2013-02
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Indications for use 1 Contraindications 1
Components of your H4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Setting up your H4i for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Preparation 1 System setup 2 Filling the water chamber 3 Detaching your H4i 3
Starting and stopping treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warming your H4i with the VPAP or S8 Series 4 Warming your H4i with the Stellar 4 Starting your treatment 4 Stopping your treatment 5
Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Disassembling the H4i cleanable water chamber 5 Cleaning your H4i 6 Reassembling the H4i cleanable water chamber 7 Reassembling your H4i 8 Servicing 8 Frequently asked questions 8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Humidifier performance 10 Symbols which appear on the device 11
General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Limited warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Introduction
Cover seal
Cover
Connector seal
Air outlet
Latch
Heater plate
Water chamber
Docking station
Control dial
Accessories:
H4i Water Chamber
H4i Cleanable Water Chamber
ResMed Tubing Wrap
Spill guard
Indicator light
(b)
(a)
The H4i™ is designed to moisten the air delivered to your airway during Positive Airway Pressure (PAP) therapy.
Indications for use
The H4i is indicated for humidification of the air delivered from a ResMed compatible CPAP, bilevel and non-invasive ventilation device. The H4i is for use only as recommended by a physician.
Contraindications
The H4i is contraindicated for use with patients whose upper (supraglottic) airway has been bypassed. Please also refer to the relevant system manual for contraindications associated with PAP therapy.
Components of your H4i
English
Setting up your H4i for use
Preparation
Remove the connector plug from your flow generator (a) and attach it to the back of the docking station (b).
1Introduction
System setup
!
3
4
5
1
2
1 Align your H4i with your flow generator and push them together until they click into
place. Connect the power cord to the socket on the rear of your flow generator.
2 3 Plug the other end of the power cord into the power outlet.
Place the combined unit on a firm, level surface near your bed at a level lower than your sleeping position. Ensure the surface is not sensitive to heat and/or moisture, or use a protective mat.
Connect one end of the air tubing firmly onto the air outlet.
4 5 Connect the assembled mask system to the free end of air tubing.
WARNING
Make sure your flow generator is switched off at the power outlet before
connecting the H4i.
The H4i docking station should only be connected or disconnected when the
water chamber is empty.
Water must be prevented from entering your flow generator. Do not
transport the flow generator with the H4i attached.
The H4i is contraindicated for invasive use. An external humidifier approved
for invasive use is recommended according to EN ISO 8185.