ResMed 150 User Manual

Page 1
StellarTM 150
ADULT AND PAEDIATRIC VENTILATOR
Easy access to intelligent therapy
iVAPS
new
Remote
Alarm
With
and
Adult use
Paediatric use
iVAPS mode
Remote alarm
SpO
2
FiO
2
Page 2
Stellar 150: easy access to intelligent therapy
From hospital care to
homecare, invasive to
noninvasive applications,
paediatric to adult use …
ResMed’s Stellar 150
ventilator offers intelligent
ventilation in one easy,
accessible device.
Light, small and quiet,
Stellar 150 combines
simplicity with unique new
features, such as ResMed’s
iVAPS technology and a
remote alarm.
From set-up to therapy
management and monitoring,
Stellar 150 is the easiest
way to establish confidence
among clinical staff
and carers.
More in one
NEW! Extra assurance with remote alarm: Stellar 150’s louder fixed and
adjustable alarms have just been complemented by a new Remote Alarm which means that it is now even more suited to environments such as the hospital or for patients who need closer monitoring at home.
Mobility and portability: equipping patients for therapy on the move with an internal battery
2
battery
(the ResMed Power Station II) and the purpose-built Mobility bag to carry and protect the ventilator and accessories. The bag allows access to the Stellar user interface.
Integrated or external humidification options: the H4i™ Heated Humidifier
for Stellar completely integrates with the ventilator if required. HumiCare D900 works as an external active heated humidification option when consistent humidification in changing conditions is essential.
1
, an optional external
High oxygen delivery: the device can use up to 30 L/min FiO
can be reached.
2
3
of oxygen, so a high
Advanced technology
Low-inertia blower: comprised of
ResMed’s unique low-inertia motor and impeller; delivers higher performance more quietly than a conventional motor.
Removable, replaceable air path: for easier and quicker device cleaning and servicing, minimising any down-time.
Vsync and TiControl™: proven ResMed noninvasive ventilation (NIV) technologies work together to improve ventilation, disease management, patient comfort and sleep quality. Therapy acceptance improves because the patient’s breathing is more ‘in sync’ with their device.
1 Two hours capacity at EPAP 5 cm H2O, IPAP 15 cm H2O, 20 bpm 2 Eight hours capacity per battery at EPAP 5 cm H
H2O, 20 bpm
3 iVAPS can only be used with 4 L/min of O2
O, IPAP 15 cm
2
iVAPS* (intelligent Volume-Assured Pressure Support)
Intelligent: alveolar ventilation and an
intelligent Back-up Rate (iBR) for efficacy, synchrony and comfort
• Intelligently targets alveolar ventilation, accounting for anatomical dead space to ventilate the patient more effectively
• Provides an iBR when required, to help maintain or restore synchrony during or after events such as coughing and sighing
Personalised: the Learn Targets feature for easy and individualised set-up
• Learns the patient’s alveolar ventilation and sets targets accordingly
• Learns the patient’s spontaneous
respiratory rate and uses this as input for the iBR
• Minimises the need for constant
manual adjustment, while enabling clinicians to review and accept or change recommended target settings
Automatic: adaptable pressure support and an iBR for the patient’s changing ventilation needs
• Automatically adjusts the pressure
support to achieve and maintain the target alveolar ventilation; constantly monitors the patient’s actual ventilation in relation to the target ventilation
• Automatically determines when an
iBR is required; constantly monitors the patient’s actual respiratory rate in relation to the target rate
• Adapts to the patient’s changing
needs, such as during different stages of sleep
* iVAPS mode is for patients 30 kg and above.
Page 3
N
T
O
I
C
A
G
N
I
D
I
V
O
R
P
V
r
a
l
l
e
t
S
P
A
P
V
N
U
U
M
E
l
i
I
I
I
S
s
O
é
e
F
C
A
R
E
DEPENDENT PATIENTSNONDEPENDENT PATIENTS
VENTILATORS
Live comprehensive monitoring information at your fingertips
The Synchronisation screen displays spontaneous verses machine-triggered/ cycled breaths
iVAPS mode targets alveolar ventilation and the patient’s respiratory rate for efficacy, synchrony and comfort
Optimal accuracy and synchrony
Learn Circuit: at the push of a button the
device initiates this inbuilt test to measure and compensate for changes in circuit impedance (caused by the use of anti-bacterial filters, humidifiers and other accessories).
Pathology Defaults: a choice of disease-specific preset values, based on commonly-used clinical values for obstructive, restrictive, obesity hypoventilation and normal lung mechanics. Advanced settings are optimised so medical staff can focus on fine-tuning primary settings for each patient.
Mask selection and fitting: selecting the correct mask in the user menu enables the device to compensate for differences in mask vent flow and impedance. This optimises patient comfort and patient– ventilator synchrony. The Mask Fit feature delivers flow before therapy begins, to test for excessive mask leak; it helps achieve the best fit for the patient without over-tightening the mask.
Data and monitoring
Real-time monitoring on the LCD:
the Monitoring Menu provides essential data, including simultaneously-viewed flow and pressure curves, the Ti-bar graph to fine-tune ventilation, and SpO
monitoring.
FiO
2
Real-time remote monitoring:
EasyCare Tx software connects to Stellar 150 via the Tx Link, offering real-time remote titration, where settings can be changed remotely.
Summary data and reminders on the LCD: the Info Menu provides a snapshot
of therapy information for seven sessions at a time, with easy scrolling for up to 365 sessions. It also provides patient reminders like filter and mask replacements.
Downloadable data: the device stores usage and summary data for up to 365 treatment sessions and seven days of high-resolution, breath-by-breath data (including SpO
and FiO2); this can be
2
downloaded via USB or cable, using ResScan™ software.
and
2
The Event Summary screen provides a quick overview of the main events, such as setting changes and alarms
Page 4
Stellar 150 system and accessories—ordering information
Stellar 150 ANZ and APAC 24162
H4i Heated Humidifier for Stellar ANZ 26951 APAC 24930
HumiCare D900
18405
Mobility bag
24977
Pulse oximeter
22305 (Oximeter cable) 16936 (1 sensor and
25 tapes)
FiO2 monitoring kit (does not include FiO
2
monitoring sensor CAP008617) 24955
Remote Alarm II (does not include cables) ROW 27902
ResMed Power Station II Battery and bag 24921 DC cable 24959 Power supply 90W ANZ and APAC 36824
ResMed leak valve 24988
Specifications
STELLAR 150
MODES iVAPS (intelligent Volume-Assured
PRESSURE RANGE IPAP: 2–40 cm H
TiCONTROL Ti Max 0.3–4 sec
RESPIRATORY RATE 5–60 bpm
RISE TIME Min, 150–900 msec (approx.)
TRIGGER AND CYCLE Five sensitivity settings
ADJUSTABLE High Leak ALARMS Low Minute Ventilation
STANDARD FIXED Circuit disconnected ALARMS Over pressure
DIMENSIONS 230 x 170 x 120 mm (L x W x H)
WEIGHT 2.1 kg
AIR FILTER Electrostatic fibre mesh
AIR OUTLET 22 mm taper, compatible with
INTERNAL BATTERY Lithium-ion, 2 hours at EPAP 5,
POWER SUPPLY AC 100–240V 50–60Hz,
IEC 60601–1 Class II (double insulation) CLASSIFICATION Type BF Continuous operation
Pressure Support)
S/T (Spontaneous/Timed) PAC (Pressure Assisted Control) CPAP (Continuous Positive
Airway Pressure)
S (Spontaneous) T (Timed)
O
EPAP: 2–25 cm H
Ti Min 0.1–Ti Max
High Pressure Low Pressure High Respiratory Rate Low Respiratory Rate Apnea High FiO Low FiO Low SpO Non-vented mask
Blocked tube Internal battery empty (See Clinical Guide for full list of alarms)
ISO 5356–1:2004
IPAP 15, 20 bpm
2.2A AC 110V 400Hz,
2.2A DC 24V/3A
2
O
2
2
2
2
RESMED POWER STATION II
BATTERY TECHNOLOGY Lithium-ion
RECHARGE TIME 4 hours from fully empty to
BATTERY DURATION 8 hours per battery at
CAPACITY <100 Wh
DIMENSIONS 230 x 126 x 26 mm
(L x W x H)
BATTERY WEIGHT 0.9 kg
POWER SUPPLY Input range 100–240 V,
fully charged
EPAP 5 cm H 15 cm H batteries can be connected simultaneously. See www.resmed.com/RPSII for more details)
50–60 Hz, 1.0-1.5 A Nominal for aircraft use 110 V, 400 Hz
O, IPAP
2
O and 20 bpm (two
2
For more information
on Stellar 150
please visit
www.stellar150.com
Stellar 150 features
ResMed Germany Inc.
Fraunhoferstr. 16 82152 Martinsried Germany.
Distributed by: ResMed Ltd Bella Vista, NSW, Australia +61 (2) 8884 1000 or 1 800 658 189 (toll free). ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. See www.resmed.com for other ResMed locations worldwide. H4i, ResScan, SlimLine, Stellar and TiControl are trademarks of ResMed Ltd. Stellar is registered in U.S. Patent and Trademark Office. © 2012 ResMed Ltd. Specifications may change without notice. 1014183/4 2012-09
Global leaders in sleep and respiratory medicine www.resmed.com
Loading...