Renu Electronics FlexiPanels FP4 Series, FP4043T, FP4043TN, FP4070T, FP4070TN User Manual

...
User Manual
FlexiPanels®Advance HMI
FP4 Series
FlexiPanels® Advance HMI
Page 2 of 17
© Renu Electronics Pvt. Ltd.
Table of Contents
INTRODUCTION ................................................................................................................................................... 3
BEFORE YOU START .............................................................................................................................................. 3
SAFETY PRECAUTIONS .......................................................................................................................................... 4
PRODUCT OVERVIEW ........................................................................................................................................... 5
INSTALLING FP4 PRODUCTS ........................................................................................................................................ 5
P
ANEL GUIDELINES ................................................................................................................................................................ 5
P
ANEL CUTOUT DIMENSIONS .................................................................................................................................................. 5
P
RODUCT DIMENSIONS .......................................................................................................................................................... 5
M
INIMUM CLEARANCES ......................................................................................................................................................... 7
M
OUNTING FP4 PRODUCTS .................................................................................................................................................... 7
C
ONNECTING POWER ............................................................................................................................................................. 7
G
ROUNDING ......................................................................................................................................................................... 7
PRODUCT SPECIFICATIONS ................................................................................................................................... 8
PRODUCT NOMENCLATURE / ORDERING PART NUMBER ................................................................................................... 8
D
ISPLAY SPECIFICATIONS ............................................................................................................................................ 8
CPU,
MEMORY AND POWER SUPPLY ............................................................................................................................ 9
P
OWER RATING ..................................................................................................................................................................... 9
C
OMMUNICATION INTERFACES .................................................................................................................................. 10
RS232
/ RS422 / RS485 PORT ............................................................................................................................................ 10
E
THERNET PORT .................................................................................................................................................................. 12
USB
DEVICE PORT ............................................................................................................................................................... 12
USB
HOST PORT ................................................................................................................................................................. 12
Y
TYPE CABLE...................................................................................................................................................................... 13
SD
CARD SLOT .................................................................................................................................................................... 13
A
CCESSORIES ........................................................................................................................................................ 14
P
ROGRAMMING CABLE ........................................................................................................................................................ 14
C
OMMUNICATION CABLE ...................................................................................................................................................... 14
DEFAULT PRODUCT SETTING .............................................................................................................................. 15
ENVIRONMENTAL SPECIFICATIONS AND APPROVALS ....................................................................................................... 15
REVISION HISTORY ............................................................................................................................................. 16
NOTES ............................................................................................................................................................... 17
FlexiPanels® Advance HMI
Page 3 of 17
© Renu Electronics Pvt. Ltd.
Introduction
FP4 Advance HMI series is a powerful, feature rich and versatile HMI product range with a complete range of screen size starting with compact 4.3” WQVGA TFT color display, covering most popular screen sizes in the industry (7”, 10.1”, 12.1”), till dynamic 15” XGA TFT color screen. These HMIs are powered by FlexiSoft® programming software and supports a powerful FlexiSoft® runtime for efficient performance. IEC61131-3 logic programming environment support give a unique edge to these products.
All the products are compliant to EMC directive 2014/30/EU and LVD directive 2014/35/EU and suitable for installation in hazardous locations, because they are listed for UL Class I Div. 2.
This user manual gives detailed information regarding the hardware specifications, operating conditions, installation, mounting and wiring. All the information published in this manual is produced and governed by Renu Electronics Pvt. Ltd. and is protected by Indian Copyright Act.
Before you start
FlexiPanels® FP4 series products are general purpose human machine interface devices,
suitable for a variety of industrial applications across various industries. However, Renu Electronics is not responsible or liable for any indirect or consequential damage resulting from the use of this product.
The user should check and confirm the suitability of the product before using in any specific
application.
The diagrams and examples in this manual are included for illustration purpose only. Renu
Electronics assume no responsibility or liability regarding actual use based on these diagrams or examples.
Reproduction of the contents of this manual, in any form (in part or in whole), is strictly
prohibited.
Following table shows various symbols that may be used in this manual to provide information
regarding safety, precautions and usage of the product:
WARNING: Indicates circumstances that may cause an explosion in hazardous environment, which may lead to injury or death, damage or economic loss
CAUTION: Indicates specific precautions to be taken by user during installation, operation and maintenance of the product
ATTENTION
ATTENTION: Indicates important information regarding application and functions of
the product
FlexiPanels® Advance HMI
Page 4 of 17
© Renu Electronics Pvt. Ltd.
Safety Precautions
This section of the manual provides information which is critical regarding safety and therefore the user is advised to go through the information in detail before installing the product. User may contact Renu Electronics technical support team at support@renuelectronics.com for any specific question(s) related to safety.
WARNING: EXPLOSION HAZARD
Do not disconnect equipment unless power has been removed or the area is known
to be nonhazardous.
Substitution of any component may impair suitability for Class I, Division 2. Secure any external connections that mate to this equipment by using screws, sliding
latches, threaded connectors or any other means provided with this product.
If this product contains batteries, they must only be changed in an area known to be
nonhazardous.
CAUTION: GENERAL PRECAUTIONS
Do not use this product for emergency stop. A separate physical switch, outside the
product must be used for any emergency stop operations.
Do not use the external power supply source that does not comply with the specified
power requirements of the product, it may cause malfunction or permanent damage to the product.
Do not attempt to open, dismantle or modify the p
roduct, doing so will void the
warranty.
This product is supplied as open-type equipment and it must be mounted within an
enclosure, suitably designed for specific environmental conditions.
When used in Class I, Division 2 hazardous location, the product must be mounted
in a suitable enclosure with proper wiring method that complies with the governing electrical codes.
The USB port is intended for temporary local programming purpose only and not
intended for permanent connection. If you connect or disconnect the USB cable with power applied to this product or any other device on USB network, and electrical arc can occur, which could cause explosion in hazardous location installations.
Make sure that connectors are securely tightened to properly seal the connections
against leaks.
Do not place the product in direct sunlight. Prolonged exposure to sunlight may degrade the LCD and housing.
FlexiPanels® Advance HMI
Page 5 of 17
© Renu Electronics Pvt. Ltd.
Product Overview
This section of the manual provides an overview of FP4 series products, its front and back view, installation details, dimensional details, mounting method and details.
Installing FP4 products
FP4 series products are designed for front panel mounting. Before installing the products, user should review the panel guidelines, panel cutout dimensions, product dimensions and minimum clearances.
Panel Guidelines
The panel must be at least 2mm (12gauge), so that it can provide the required support and proper sealing against water and dust. The panel surface must be flat, without any imperfection, to maintain adequate seal and IP rating. Maximum panel thickness allowed is 6mm (±0.2mm).
Panel Cutout Dimensions
The panel must be at least 2mm (12gauge), so that it can provide the required support and proper sealing against.
Model
Height (mm)
Width (mm)
FP4043T
80
111
FP4043TN
80
111
FP4070T
127
175
FP4070TN
127
175
FP4101T
178
256
FP4101TN
178
256
FP4121T
225
293
FP4121TN
225
293
FP4151T
285
386
FP4151TN
285
386
ATTENTION
ATTENTION: Panel cutout
Before making panel cutout, disconnect all electrical power from the panel. Make sure that area surrounding the panel cutout is clear. Make sure that metal cutting does not enter any component already installed in the
panel.
Product Dimensions
This section of the manual provides dimensional details of FP4 series products. All the dimensions shown below are measured in mm.
FlexiPanels® Advance HMI
Page 6 of 17
© Renu Electronics Pvt. Ltd.
FlexiPanels® Advance HMI
Page 7 of 17
© Renu Electronics Pvt. Ltd.
Minimum Clearances
Maintain clearance from enclosure walls, wires and other adjacent devices. Keep 2” space on all sides for adequate ventilation. Plan for adequate space around the product and inside the enclosure for ventilation and cabling. Take into consideration the heat produced by other devices in the enclosure. The ambient temperature around this product must be -10° to 60°C.
Mounting FP4 Products
FP4 series products must be installed on the front panel, using the clamp accessories shipped with the product. Before mounting, make sure that sealing gasket is properly positioned. This gasket forms a compression type seal. Do not use sealing compounds. Then, place the unit in the panel cutout and tighten the mounting screws evenly (torque 0.4Nm) to maintain water and dust resistance.
ATTENTION
ATTENTION: Mounting FP4 on Panel
Do not push LCD display when pushing the unit into the panel as it may damage the
display.
Connecting Power
FP4 series require 24VDC power supply. Follow the steps mentioned below to connect the power:
Make sure that terminal is not connected to power source Secure the 24VDC power wires Secure the functional earth ground wire to the functional earth ground terminal screw on terminal
block
Apply 24VDC power to the terminal
Grounding
The optimum method for grounding electronic equipment is to ground it separately from other high-power systems and to ground more than one unit of electronic equipment with a single-point ground. Following marked terminal is provided with the unit for grounding:
FlexiPanels® Advance HMI
Page 8 of 17
© Renu Electronics Pvt. Ltd.
Product Specifications
This section of the manual provides detail specifications of FP4 series products, ordering part numbers, operating conditions, environment and approvals.
Product Nomenclature / Ordering Part Number
FP4 series has 5 models, depending on display size and each model has two variants, based on Ethernet and SD Card slot support. Detail part number or ordering information is as follows:
Display Specifications
FP4 series products support high quality color TFT display range.
Size: 4.3” WQVGA color TFT with 4-wire analog resistive touch screen
Resolution: 480 x 272pixels Brightness: 400cd/m
2
Backlight life: 30,000Hrs.
Size: 7” WVGA color TFT with 4-wire analog resistive touch screen
Resolution: 800 x 480pixels Brightness: 350cd/m
2
Backlight life: 30,000Hrs.
Size: 10.1” WVGA color TFT with 4-wire analog resistive touch screen
Resolution: 1024 x 600pixels Brightness: 350cd/m
2
Backlight life: 50,000Hrs.
Size: 12.1” SVGA color TFT with 4-wire analog resistive touch screen
Resolution: 800 x 600pixels Brightness: 500cd/m
2
Backlight life: 70,000Hrs.
Size: 15” XGA color TFT with 4-wire analog resistive touch screen
Resolution: 1024 x 768pixels Brightness: 400cd/m
2
Backlight life: 50,000Hrs.
FlexiPanels® Advance HMI
Page 9 of 17
© Renu Electronics Pvt. Ltd.
CPU, Memory and Power Supply
Power Rating
Unit
Voltage
Current
Wattage
FP4043
24VDC
140mA
3.36W
FP4070
24VDC
320mA
7.68W
FP4101
24VDC
330mA
7.92W
FP4121
24VDC
420mA
10.08W
FP4151
24VDC
800mA
19.2W
ATTENTION
ATTENTION: Logging to External memory
The Ethernet models of FP4 series supports SD card slot, which can be used to log
the data directly on SD card. MicroSD HC card with capacity between 4GB to 32GB is supported. Supported speed classes are as follows:
While inserting or removing SD card, the device power must be turned off.
The user must take periodic backup of logged data to avoid loss of data.
CPU: 32-bit RISC processor eMMC: 4GB
RAM: 512MB
User
Application
Up to 1GB that includes user
application, data log, alarms,
retentive memory and logic memory
Power Supply:
24VDC (±15%) with isolation
RTC:
Built-in, date and time function
FlexiPanels® Advance HMI
Page 10 of 17
© Renu Electronics Pvt. Ltd.
Communication Interfaces
This section of the manual gives detail information regarding various communication interfaces supported by FP4 series products, including communication interfaces between FP4 and other RENU or any third-party device, interfaces for programming and monitoring.
RS232 / RS422 / RS485 Port
FP4 products support DB9 female port for RS232 / RS422 / RS485 communication. 4.3” and 7” models support one DB9 female port and 10.1”, 12.1” and 15” models support two DB9 female ports.
Pin number
Signal
1
TX+(RS422/RS485)
2
TXD(RS232)
3
RXD(RS232)
4
RX+(RS422/RS485)
5
GND
6
NC 7 NC
8
TX-(RS422/RS485)
9
RX-(RS422/RS485)
7” model support one terminal block port (COM 1).
Pin number
Signal
1
RX- 2 TX-
3
RX+
4
TX+
5
GND
6
RXD
7
TXD
FlexiPanels® Advance HMI
Page 11 of 17
© Renu Electronics Pvt. Ltd.
ATTENTION
ATTENTION: DB9 port
The 4.3” models have only one DB9 port that supports RS232 and RS422 / RS485
signal levels on different pins.
If user wants to connect different devices on RS232 and RS422 / RS485 levels,
simultaneously with 4.3” HMI, then he must use ‘Y’ type cable.
FlexiPanels® Advance HMI
Page 12 of 17
© Renu Electronics Pvt. Ltd.
Ethernet Port
FP2 series support Ethernet port as an ordering option. It’s having standard shielded RJ45 female jack with built-in speed and indication LED’S.
Pin number
Signal
1
TX+
2
TX-
3
RX+
4
NC
5
NC 6 RX-
7
NC
8
NC
USB Device Port
FP4 products support one Micro USB port for programming and monitoring.
Pin number
Signal
1
VCC
2
D-
3
D+
4
NC
5
GND
USB Host Port
FP4 products support one USB Host port that connects to USB 2.0 compatible pen drives. The pen drive can be used as external memory for data logging and transferring user application or firmware to the unit.
Pin number
Signal
1
VCC
2
D-
3
D+
4
GND
1
5
FlexiPanels® Advance HMI
Page 13 of 17
© Renu Electronics Pvt. Ltd.
Y Type Cable
Special “Y” cable for FP unit (two communication levels on one port).
SD Card Slot
Ethernet models of FP4 products support one SD card slot. SD card can be used as external memory for data logging and transferring user application or firmware to the unit. MicroSD HC card with capacity between 4GB to 32GB is supported.
Following speed classes are supported:
FlexiPanels® Advance HMI
Page 14 of 17
© Renu Electronics Pvt. Ltd.
Accessories:
Programming Cable (Download)
Micro USB
Part number: PC-USBAB-00-Micro
[Note: PC-USBAB-00: 2M cable, PC-USBAB-05: 5M cable, PC-USBAB-10: 10M cable]
Communication Cable
RS-232
Part number: IBM0909-1-00
[Note: IBM0909-1-00: 2M cable, IBM0909-1-05: 5M cable, IBM0909-1-10: 10M cable]
FlexiPanels® Advance HMI
Page 15 of 17
© Renu Electronics Pvt. Ltd.
Default Product Setting
Network Setting
DHCP
Brightness
Full Scale
Beeper
On
Default Language
English
RTC Settings
Current Date/Month/Year Current Time
Environmental Specifications and Approvals
Feature
Specifications
Operating Temperature
-10° to 60°C
Storage Temperature
-20° to 85°C
Relative Humidity
10 to 95% non-condensing
Shock
IEC 60068-2-27
25g, 11ms, 6 shocks per axis,
total 18 shocks (X, Y, Z)
Vibration
IEC 60068-2-6 5 to 150Hz, 3g peak (X, Y, Z)
EMC
EN 55011 : 2009/A1 : 2010
EN 61131-2 : 2007 EN 61000-6-2 : 2005/AC : 2005
EN 61000-6-4 : 2007/A1 : 2011
Protection
IP66 for front panel mounting
CE
Yes
UL
Yes (Class I Division 2)
RoHS
Yes
[Note: For UL Operating Temperature range is 0-50°C]
FlexiPanels® Advance HMI
Page 16 of 17
© Renu Electronics Pvt. Ltd.
Revision History
Revision
Description
Date
Prepared by
Approved by
1.0
First Draft
25/07/2018
PM
AR
1.1
1. Panel Cutout Information is Corrected
2. Added Power Rating in Product Specifications
3. Added Default Product Settings
07/12/2018
PM
AR
1.2
Ordering part number of 15" HMI is changed from
FP4150 to FP4151
13/12/2018
PM
AR
Renu Electronics reserves the right to change or discontinue specifications and features without prior notice.
FlexiPanels® Advance HMI
Page 17 of 17
© Renu Electronics Pvt. Ltd.
NOTES
Loading...