Renogy MPPT20CC User Manual

Page 1
MPPT20CC
14288 Central Ave., Suite A Chino, CA 91710
RENOGY 20A Maximum Power Point Tracking Solar Charge Controller Manual
1-800-330-8678
Page 2
1
Contents
1. Important Safety Information 2
2. General Information 3
2.1 Overview 3
2.2 Optional Accessories 5
3. Installation Instructions 6
3.1 General Installation Notes 6
3.2 Mounting 6
3.3 Wiring 7
4. Operation 10
4.1 MPPT Technology 10
4.2 Battery Charging Information 12
4.3 LED Indications 13
4.4 Setting Operation 15
5. Protections, Troubleshooting and Maintenance 19
5.1 Protection 19
5.2 Troubleshooting 20
5.3 Maintenance 21
6. Warranty 22
7. Technical Specifications 23
Page 3
2
1. Important Safety Information
Save These Instructions
This manual contains important safety, installation and operating instructions for the MPPT20CC controller. The following symbols are used throughout this manual to indicate potentially dangerous conditions or mark important safety
instructions. Please take care when meeting these symbols.
WARNING: Indicates a potentially dangerous condition. Use extreme
caution when performing this task.
CAUTION: Indicates a critical procedure for safe and proper operation
of the controller
NOTE: Indicates a procedure or function that is important for the safe
and proper operation of the controller. General Safety Information
• Read all of the instructions and cautions in the manual before beginning installation.
• There are no user serviceable parts inside the MPPT20CC. Do not
disassemble or attempt to repair the controller.
• Disconnect the solar module and fuse/breakers near to battery before installing or adjusting the MPPT20CC.
• Install external fuses/breakers as required.
• Do not allow water to enter the controller.
• Confirm that the power connections are tightened to avoid excessive
heating from a loose connection.
Page 4
3
2. General Information
2.1 Overview
The RENOGY MPPT series controller is suitable for off-grid solar applications. It protects the battery from being over-charged by the solar modules and over­discharged by the loads. The controller features a smart tracking algorithm that maximizes the energy from the solar PV module(s) and charge the battery. At the same time, the low voltage disconnect function (LVD) will prevent the battery from over discharging.
The MPPT20CC controller charging process has been optimized for long battery life and improved system performance. The comprehensive self-diagnostics and electronic protection functions can prevent damage from installation mistakes or system faults. In addition, the MPPT20CC controller has a RJ45 interface to allow communication with a meter for remote monitoring. The MPPT20CC has
the following features:
• 12V / 24V auto recognition.
• Advanced maximum power point tracking technology to optimize the use
of the PV system.
• Peak conversion efficiency of 97 %, high Tracking efficiency of 99%.
• Fast sweeping of the entire I-V curve, several seconds tracking speed.
• Widely used, automatic recognition of day and night.
• Timer function with 1-15 hour option for streetlight.
• Unique dual timer function; enhance the flexibility lighting systems.
• Sealed, Gel and Flooded battery option.
• Adopting temperature compensation and correcting the charging and
discharging parameters automatically, improving battery lifetime.
• Electronic protection: Overcharging, over-discharging, overload, and short circuit.
• Reverse protection: Any combination of solar module and battery, without
causing damage to any component.
• Excellent thermal design and natural air-cooling.
• RJ45 interface for use with the remote meter MT-5, convenient to check
operating parameters of controllers.
Although the MPPT20CC controller is very simple to configure and use, please take your time to read the operator's manual and become familiar with the controller. This will help you make full use of all the functions and improve your solar PV system.
Page 5
4
Description of MPPT20CC controller:!
Figure 2-1 MPPT20CC Characteristics
1. Charging Status LED indicator
2. Battery Status LED indicator
3. Temperature Sensor
4. Setting Indicators
5. LED Digital Display the load work mode and status.
6. Setting Button (in manual mode used for load ON/OFF)
7. Solar Module Terminals
8. Battery Terminals
9. Load Terminals
10. RJ45 Communication Interface (for remote meter MT-5)
RJ45
Page 6
5
2.2 Optional Accessories
Remote Meter (Model: MT-5)
The digital remote meter displays system operating information, error indications,
and self-diagnostics read-out. Information is displayed on a backlit LCD display. The large numerical display and icons are easy to read and large buttons make navigating the meter menus easy. The meter can be flush mounted in a wall or surface mounted using the mounting frame (included). The MT-5 is supplied with 2 m of cable and a mounting frame. The MT-5 connects to the RJ45 port on the
MPPT20CC.
Page 7
6
3. Installation Instructions
3.1 General Installation Notes
• Read through the entire installation section first before beginning installation.
• Be very careful when working with batteries. Wear eye protection. Have
fresh water available to wash and clean any contact with battery acid.
• Uses insulated tools and avoid placing metal objects near the batteries.
• Explosive battery gasses may be present during charging. Be certain
there is sufficient ventilation to release the gasses.
• Avoid direct sunlight and do not install in locations where water can enter
the controller.
• Loose power connections and/or corroded wires may result in resistive
connections that melt wire insulation, burn surrounding materials, or even
cause fire. Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in mobile applications.
• Use with Gel, Sealed or Flooded batteries only.
• Battery connection may be wired to one battery or a bank of batteries. The
following instructions refer to a single battery, but it is implied that the battery connection can be made to either one battery or a group of
batteries.
• Select the system cables according to 3A/mm2 current density.
3.2 Mounting
NOTE: When mounting the MPPT20CC, ensure free airflow through the controller heat sink fins. There should be at least 150mm of clearance above and below the controller to allow for cooling. If mounted in an
enclosure, ventilation is highly recommended.
WARNING: Risk of explosion! Never install the MPPT20CC in a sealed
enclose with flooded batteries! Do not install in a confined area where
battery gas can accumulate.
Page 8
7
Step 1: Choose mounting location
Locate the MPPT20CC on a vertical surface protected from direct sunlight, high
temperature, and water.
Step 2: Check for Clearance
Place the MPPT20CC in the location where it will be mounted. Verify that there is sufficient room to run wires and that there is sufficient room above and below the controller for airflow.
Step 3: Mark Holes
Use a pencil or pen to mark the four (4) mounting hole locations on the mounting
surface.
Step 4: Drill Holes
Remove the controller and drill four sizeable holes in the marked locations.
Step 5: Secure Controller
Place the controller on the surface and align the mounting holes with the drilled holes in step 4. Secure the controller in place using the mounting screws.
3.3 Wiring
NOTE: A recommended connection order has been provided for
maximum safety during installation.
NOTE: The MPPT20CC is a negative ground controller. Any negative connection of the solar module, battery or load can be earth grounded.
CAUTION: Don’t connect the loads with surge power exceeding the
ratings of the controller.
CAUTION: For mobile applications, be sure to secure all wiring. Use cable clamps to prevent cables from swaying when the vehicle is in motion. Unsecured cables create loose and resistive connections, which may lead
to excessive heating and/or fire.
Page 9
8
Step 1: Battery Wiring
WARNING: Risk of explosion or fire! Never short circuit battery
positive (+) and negative (-) or cables
Figure 3-1 Battery wiring
Before connecting the battery, measure the battery voltage. It must be over 9V to power the controller. For 24V, the voltage must be greater than 18V to properly detect a 24V battery. The 12/24V battery detection is automatic and the check is
only performed at start-up.
Wire an in-line fuse holder no more than 150mm from the battery positive terminal. Do not insert a fuse at this time. Confirm the connection correct and then turn on the power.
Step 2: Load Wiring
The MPPT20CC load output can connect DC electronic devices of which the rated voltage is the same as the battery. MPPT20CC will provide battery the voltage to the loads. See Section 4.4 Setting Operation for more details about the
load control.
Figure 3-2 Load wiring
Connect load positive (+) and negative (-) to the MPPT20CC load output as shown in figure 3-2. Exercise caution when connecting to the load terminals, there may be an existing voltage, which may cause a short circuit. An in-line fuse holder should be wired in series in the load positive (+) or negative (-) wire as
Page 10
9
shown. Do not insert a fuse at this time. Confirm the connection is correct and
then turn on the power.
If wiring the load connection to a load distribution panel, each load circuit should
be fused separately. The total load draw should not exceed the 20A load rating.
Step 3: Solar Module Wiring
WARNING: Risk of electric shock! Exercise caution when handling solar wiring. The solar module(s) high voltage output can cause severe shock or injury. Cover the solar module(s) from the sun before installing solar wiring.
The MPPT20CC can accept 12V or 24V nominal off-grid solar module arrays. Grid-tie solar module(s) may be used if the open circuit voltage does not exceed the maximum solar input rating. The solar module(s) nominal voltage must be
equal to or greater than the nominal battery voltage.
Figure 3-3 Solar Module wiring
Step 4: Accessories (option)
Install Remote Meter (purchased separately) if required. Refer to the instructions
provided for detailed installation procedures.
Step 5: Confirm Wiring
Double-check the wiring in step1 through 4. Confirm correct polarity at each
connection. Verify that all power terminals are tightened.
Step 6: Confirm Power-up
When battery power is applied and the MPPT20CC powers up, the battery led
indicator will be green. If the MPPT20CC does not power-up or battery status LEDs error exists, refer to Section 5 “Troubleshooting”
Page 11
10
4. Operation
4.1 MPPT Technology
The MPPT20CC utilizes Maximum Power Point Tracking technology to extract maximum power from the solar module(s). The tracking algorithm is fully automatic and does not require user adjustment. MPPT technology will track the array’s maximum power point voltage (Vmp) as it varies with weather conditions, ensuring that the maximum power is harvested from the array throughout the
course of the day.
Current Boost
In many cases, MPPT20CC MPPT technology will boost the solar charge current. For example, a system may have 8 Amps of solar current flowing into the charge controller and 10 Amps of charge current flowing out to the battery. The MPPT20CC does not create current! Rest assured that the power into the charge controller is the same as the power out of the MPPT20CC. Since power is the product of voltage and current (Volts × Amps), the following is true*:
• Power Into the controller = Power Out of the controller
• Volts In × Amps In = Volts Out × Amps Out
*Assuming 100% efficiency. Actually, the losses in wiring and conversion exist. If the solar module’s Vmp is greater than the battery voltage, it follows that the battery current must be proportionally greater than the solar input current so that input and output power are balanced. The greater the difference between the
maximum power voltage and the battery voltage, the greater the current boost. Current boost can be substantial in systems where the solar array is of a
higher nominal voltage than the battery.
An Advantage Over Traditional Controllers
Traditional controllers connect the solar module directly to the battery when recharging. This requires that the solar module operate in a voltage range that is below the module’s Vmp. In a 12V system for example, the battery voltage may range from 11-15Vdc but the module’s Vmp is typically around 16 or 17V.Figure 4-1 shows a typical current vs. voltage output curve for a nominal 12V off-grid
module.
Page 12
11
Figure 4-1 Nominal 12V Solar Module I-V curve and output power graph
The array Vmp is the voltage where the product of current and voltage (Amps × Volts) is greatest, which falls on the knee of the solar module I-V curve as shown in Figure 4-1. Because Traditional controllers do not operate at the Vmp of the solar modules(s), energy is wasted that could otherwise be used to charge the battery and power system loads. The greater the difference between battery
voltage and the Vmp of the module, the more energy is wasted.
MPPT20CC MPPT technology will always operate at the Vmp resulting in less
wasted energy compared to traditional controllers.
Conditions that Limits the Effectiveness of MPPT
The Vmp of a solar module decreases as the temperature of the module increases. In very hot weather, the Vmp may be close or even less than battery voltage. In this situation, there will be very little or no MPPT gain compared to traditional controllers. However, systems with modules of higher nominal voltage than the battery bank will always have an array Vmp greater than battery voltage. Additionally, the savings in wiring due to reduced solar current make MPPT
worthwhile even in hot climates.
Typical Battery Voltage Range
Maximum
Power Point
Traditional
Controller
Range
Maximum
Power Point
Current vs. Voltage (12V System)
Output Power (12V System)
Operating
Page 13
12
4.2 Battery Charging Information Four Charging Stages
The MPPT20CC has a 4-stage battery-charging algorithm for rapid, efficient, and safe battery charging.
Figure 4-2 MPPT20CC MPPT charging algorithm
Bulk Charge
In this stage, the battery voltage has not yet reached boost voltage and 100% of available solar power is used to recharge the battery.
Boost Charge
When the battery has recharged to the Boost voltage set point, constant-voltage regulation is used to prevent heating and excessive battery gassing. The Boost stage remains 120 minutes and then goes to Float Charge. Each time when the controller is powered on, it checks if the battery is over-discharged or overvoltage. If none of these conditions are encountered, the controller will enter into boost charging stage.
Float Charge
After the Boost voltage stage, MPPT20CC will reduce the battery voltage to float voltage set point. When the battery is fully recharged, there will be no more chemical reactions and all the charge current transforms into heat and gas at this point. The controller reduces the voltage to the floating stage, charging with a smaller voltage and current. It will reduce the temperature of battery and prevent gassing, but charging the battery slightly at the same time. The purpose of Float stage is to offset the power consumption caused by self-consumption and small loads in the whole system, while maintaining full battery storage capacity.
In Float stage, loads can continue to draw power from the battery. In the event that the system load(s) exceed the solar charge current, the controller will no longer be able to maintain the battery at the Float set point. Should the battery voltage remains below the boost reconnect charging voltage, the controller will exit Float stage and return to Bulk charging.
Page 14
13
Equalize
WARNING: Risk of explosion! Equalizing flooded batteries can
produce explosive gases, so a well-ventilated battery box is necessary.
NOTE: Equipment damage! Equalization may increase battery
voltage to a level damaging to sensitive DC loads. Ensure that all load allowable input voltages are greater than the equalizing charging set point voltage.
NOTE: Equipment damage! Over-charging and excessive gas precipitation may damage the battery plates and activate material shedding on them. Too high an equalizing charge or for too long may cause damage. Please carefully review the specific requirements of the battery used in the system.
Certain types of batteries benefit from periodic equalizing charge, which can stir the electrolyte, balance battery voltage and complete chemical reaction. Equalizing charge increases the battery voltage, higher than the standard complement voltage, which gasifies the battery electrolyte.
If it detects that the battery is being over discharged, the solar controller will automatically turn the battery to equalization charging stage, and the equalization charging will be 120 minutes. Equalizing charge and boost charge are not carried out constantly in a full charge process to avoid too much gas precipitation or overheating of battery.
4.3 LED Indications
Figure 4-3 Charge controller LED indicators
LED Digital Display
Battery Indicator
Charging Indicator
Page 15
14
Charging Indicator
The green LED indicator will turn on whenever sunlight is available for battery charging. Under normal charging conditions, the green charging LED will stay on at all times. The charging LED indicator flashes when the battery reaches over-
voltage. Please refer to section 5 for troubleshooting.
Color
Indication
Operating State
Green
On Solid
Charging
Green
Flashing
Battery over-voltage
Table 4-1 Charging LED indicators
Battery Indicator
Color
Indication
Operating State
Green
On Solid
Normal (battery)
Green
Flashing
Full (battery)
Orange
On Solid
Low (battery)
Red
On Solid
Over Discharged (battery)*
Table 4-2 Battery LED indicators *Please refer to Chapter 5 for troubleshooting
PV Overvoltage Display
If the solar input open circuit voltage (Voc) exceeds the maximum rating, the array will remain disconnected until the Voc falls safely below the maximum rating.
Color
Indication
Operating State
Red
LED Digital Display shows letter “P"
PV Overvoltage
Table 4-3 PV Overvoltage LED Display
PV Overcurrent Display
If the solar input current exceeds the maximum rating, the array will be disconnected automatically.
Color
Indication
Operating State
Red
LED Digital Display shows letter “C"
PV Overcurrent
Table 4-4 PV Overcurrent LED Display
Page 16
15
Load indicator
When the load amperage is 1.25 times of rated current for 60 seconds, 1.5 times of rated current for 5 seconds (overload), or there is a load short circuit, the Battery LED indicator will be flashing RED. Please refer to section 5 for troubleshooting.
Color
Indication
Load Status
Red
Battery indicator flashing red
Overload or Short circuit
Table 4-5 Load LED indicators
4.4 Setting Operation
Dual Timer Function
Figure 4-4 Dual timer function diagram
The default night length is 10 hours. The controller can learn the night length referring to the previous night so as to adapt to the different seasons. However, it will take some time to learn it.
Notes: When the “OFF” time set on Timer 2 is later than local sunrise
time, the controller will turn off the load output at sunrise.
Load Control Settings
1. Dusk-to-Dawn (Light ON + Light OFF)
When solar module voltage goes below the point of NTTV (Night Time Threshold Voltage) at sunset, the solar controller will recognize the starting voltage and turn on the load after 10 minutes delay; When solar module voltage goes above point of DTTV (Day Time Threshold Voltage), the solar controller will recognize the starting voltage and turn off the load after 10 minutes delay.
2. Light ON + Timer (1-15H on)
When solar module voltage goes below the point of NTTV (Night Time Threshold Voltage) at sunset; the solar controller will recognize the starting voltage and turn
Page 17
16
on the load after 10 minutes delay for several hours which users set on the timer. The timer setting operation is referred to as “Load Work Mode Setting”.
3. Test Mode
It is used to test the system and the same as Dusk to Dawn. But there is no 10­minute delay when controller recognizes the starting voltage. When below the starting voltage, the controller will turn on the load, if higher, it will turn off load. The test mode makes it easy to check the system installation.
4. Manual Mode
This mode is to turn on/off the load by the Setting button.
Load Work Mode Setting
Figure 4-5 Instruction figure on setting
Press the setting button once and the setting indicators will be changed once among Timer 1, Timer 2 and battery type.
When Timer 1 setting indicator is on, press the setting button for more than 5 seconds until the LED digital display flashes. Then press the setting button until the desired number appears according to the Table 4-6. The setting is finished when the digital display stops flashing.
Likewise, Timer 2 set-up instructions are the same as Timer 1 using Table 4-7 as reference.
Page 18
17
Timer 1
LED Digital No.
Disable
n
Dusk-to-Dawn, Load will be on all night
0
Load will be on for 1 hour after a ten minute delay since sunset
1
Load will be on for 2 hours after a ten minute delay since sunset
2
Load will be on for 3 hours after a ten minute delay since sunset
3
Load will be on for 4 hours after a ten minute delay since sunset
4
Load will be on for 5 hours after a ten minute delay since sunset
5
Load will be on for 6 hours after a ten minute delay since sunset
6
Load will be on for 7 hours after a ten minute delay since sunset
7
Load will be on for 8 hours after a ten minute delay since sunset
8
Load will be on for 9 hours after a ten minute delay since sunset
9
Load will be on for 10 hours after a ten minute delay since sunset
10
Load will be on for 11 hours after a ten minute delay since sunset
11
Load will be on for 12 hours after a ten minute delay since sunset
12
Load will be on for 13 hours after a ten minute delay since sunset
13
Load will be on for 14 hours after a ten minute delay since sunset
14
Load will be on for 15 hours after a ten minute delay since sunset
15
Test mode
16
ON/OFF mode
17
Table 4-6 Load work mode
Timer 2
LED Digital No.
Disable
n
Load will be on for 1 hour before sunrise
1
Load will be on for 2 hours before sunrise
2
Load will be on for 3 hours before sunrise
3
Load will be on for 4 hours before sunrise
4
Load will be on for 5 hours before sunrise
5
Load will be on for 6 hours before sunrise
6
Load will be on for 7 hours before sunrise
7
Load will be on for 8 hours before sunrise
8
Load will be on for 9 hours before sunrise
9
Load will be on for 10 hours before sunrise
10
Load will be on for 11 hours before sunrise
11
Load will be on for 12 hours before sunrise
12
Load will be on for 13 hours before sunrise
13
Load will be on for 14 hours before sunrise
14
Load will be on for 15 hours before sunrise
15
Table 4-7 Load work mode
Notes: If Timer 1 is Dusk-to-Dawn (0), Test mode (16) or ON/OFF
mode (17), Timer 2 will be disabled (n).
Page 19
18
Battery Type Setting
When the Battery setting indicator is on, press the “Setting” button and hold on 5 seconds until the battery type LED turns on. The led will be flashing. Continue to hold and the number will repeat from 1 to 3, and stop pressing until the desired
number appears according to the following setting table:
Battery type
Digital display
Sealed lead acid battery
1
Gel battery
2
Flooded battery
3
Table 4-8 Battery type setting
Page 20
19
5. Protections, Troubleshooting and
Maintenance
5.1 Protection
PV Array Short Circuit
If PV array short circuit occurs, clear it to resume normal operation.
PV Overvoltage
If PV Overvoltage occurs, the array will remain disconnected until the voltage falls safely below the maximum rating.
PV Overcurrent
If PV Overcurrent occurs, the array will be disconnected automatically.
Load Overload
If the load current exceeds the maximum load current rating, the controller will disconnect the load. Reapplying power or pressing the setting button will clear up the overloading fault.
Load Short Circuit
Fully protected against load wiring short-circuit. After one automatic load reconnect attempt. Reapplying power or pressing the setting button will clear the fault.
PV Reverse Polarity
Full protection against PV reverse polarity, no damage to the controller will result. Correct the wire connection to resume normal operation.
Battery Reverse Polarity
Full protection against battery reverse polarity, no damage to the controller will result. Correct the wire connection to resume normal operation.
Damaged Local Temperature Sensor
If the temperature sensor short-circuited or damaged, the controller will be charging or discharging at the default temperature 25°C to prevent the battery damaged from overcharging or over discharged.
Page 21
20
High Voltage Transients
PV is protected against high voltage transients. In lightning prone areas, additional external suppression is recommended.
5.2 Troubleshooting
Faults
Possible reasons
Troubleshooting
Charging LED indicator off during daytime when panels are in direct sunlight
PV array disconnection
Check that PV and battery wire connections are correct and tight.
Charging LED indicator is flashing green
Battery voltage higher than over voltage disconnect voltage (OVD)
Check if battery voltage over high. Disconnect the solar module.
Battery LED indicator is orange
Battery under voltage
Load output is normal, charging LED indicator will return to green automatically when fully charged.
Battery LED indicator is red
Battery over discharged
The controller cuts off the output automatically, LED indicator will return to green automatically when fully charged.
LED digital display shows “P”
PV Overvoltage
Check whether the PV parameters match with the controller’s; It will be reconnected automatically when the voltage falls safely below the maximum rating.
LED digital display shows “C”
PV Overcurrent
Check whether the PV parameters match with the controller’s. Please refer to the controller parameters for photovoltaic parameters selection.
Battery indicator is flashing red
Over load or short circuit
Overload: Please reduce the load and press the button once, the controller will resume working after 3s.
Short circuit: when the first short-circuit occurs, the controller will automatically resume to work after 10s; when a second short­circuit occurs, press the button, the controller will resume working after 3s.
Table 5-1 Troubleshooting
Page 22
21
5.3 Maintenance
The following inspections and maintenance tasks are recommended at least two
times per year for best controller performance:
• Check that the controller is securely mounted in a clean and dry environment.
• Check that the airflow and ventilation around the controller is not blocked.
Clear all dirt or fragments on the heat sink.
• Check all the exposed wires to make sure insulation is not damaged for serious sun exposure, frictional wear, dryness, insects or rats etc. Maintain or replace the wires if necessary.
• Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
• Check and confirm that the LED digital display is consistent. Pay attention
to any troubleshooting or error indication. Take necessary corrective
action.
• Confirm that all the system components are ground connected tightly and correctly.
• Confirm that all the terminals have no corrosion, insulation damaged, high temperature or burnt/discolored sign, tighten terminal screws to the suggested torque
• Inspect for dirt, insects and corrosion, and clear up.
• Check and confirm that lightning arrester is in good condition. Replace a
new one in time to avoid damaging of the controller and other equipment.
Warning: Risk of electric shock! Make sure all the power is turned off
before above operations, and then follow the corresponding inspections
and operations.
Page 23
22
6. Warranty
The MPPT20CC charge controller is warranted to be free from defects for a period of ONE (1) year from the date of shipment to the original end user. We will, at our option, repair or replace any such defective products.
Claim procedure:
Before requesting warranty service, check the Operation Manual to be certain that there is a problem with the controller. Return the defective product to us with shipping charges prepaid if problem cannot be solved. Provide proof of date and place of purchase. To obtain rapid service under this warranty, the returned products must include the model, serial number and detailed reason for the failure, the module type and size, type of batteries and system loads. This information is critical to a rapid evaluation of your warranty claim.
This warranty does not apply under the following conditions:
1. Damage by accident, negligence, abuse or improper use.
2. PV or load current exceeding the ratings of product.
3. Unauthorized product modification or attempted repair.
4. Damaged occurring during shipment.
5. Damage results from acts of nature such as lightning or extreme weather
6. Irreclaimable mechanical damage.
Page 24
23
7. Tec h nic a l S pec i fi c a ti o ns
Electrical Parameters
Description
Parameter
Nominal System Voltage
12VDC/24VDC Auto recognition
Rated Charge Current
20A
Rated Load Current
20A
Maximum Battery Voltage
32V
Max. Solar Input Voltage*
100VDC
Max. PV Input Power
260W (12V), 520W (24V)
Self-consumption**
<10mA (24V)
Charge Circuit Voltage Drop
≤ 0.26V
Discharge Circuit Voltage Drop
≤ 0.15V
Communication
TTL232 / 8 pin RJ45
Table 7-1 Electrical Parameters *Array voltage should never exceed maximum PV input voltage. Refer to the solar module
documentation to determine the highest expected array Voc (Open Circuit Voltage) as defined by the lowest expected ambient temperature for the system location.
**Charging & discharging circuit closed, LED digital display OFF, remote meter MT-5 disconnected.
Battery Parameters (Temp: 25°C)
Control Parameter
Battery Charging setting
Gel
Sealed
Flooded
High Volt Disconnect
16.0V; x2/24V
16.0V; x2/24V
16.0V; x2/24V
Charging Limit Voltage
15.5V; x2/24V
15.5V; x2/24V
15.5V; x2/24V
Over Voltage Reconnect
15.0V; x2/24V
15.0V; x2/24V
15.0V; x2/24V
Equalization Voltage
---
14.6V; x2/24V
14.8V; x2/24V
Boost Voltage
14.2V; x2/24V
14.4V; x2/24V
14.6V; x2/24V
Float Voltage
13.8V; x2/24V
13.8V; x2/24V
13.8V; x2/24V
Boost Return Voltage
13.2V; x2/24V
13.2V; x2/24V
13.2V; x2/24V
Low Voltage Reconnect
12.6V; x2/24V
12.6V; x2/24V
12.6V; x2/24V
Under Voltage Recover
12.2V; x2/24V
12.2V; x2/24V
12.2V; x2/24V
Under Voltage Warning
12.0V; x2/24V
12.0V; x2/24V
12.0V; x2/24V
Low Voltage Disconnect
11.1V; x2/24V
11.1V; x2/24V
11.1V; x2/24V
Discharging Limits Voltage
10.8V; x2/24V
10.8V; x2/24V
10.8V; x2/24V
Equalize Duration
---
2 hours
2 hours
Boost Duration
2 hours
2 hours
2 hours
Table 7-2 Battery Parameters
Page 25
24
Threshold Voltage
Description
Parameter
NTTV (Night Time Threshold Voltage)
5V; x2/24V
DTTV (Day Time Threshold Voltage)
6V; x2/24V
Table 7-3 Threshold Voltages
Temperature Compensation
Description
Parameter
Temperature Compensation Coefficient
(TEMPCO)*
-30mV/°C/12V (25°C ref)
Table 7-4 Temperature Compensation *Compensation of equalize, boost, float and low voltage disconnect voltage
Environmental Parameters
Environmental
Parameter
Ambient Temperature Range
-35 °C to +55 °C
Storage Temperature Range
-35 °C to +80 °C
Humidity Range
10% to 90% (NC)
Enclosure
IP30
Altitude
≤ 3000m
Table 7-5 Environmental Parameters
Mechanical Parameters
Mechanical
Parameter
Dimension
169 x 118 x 83 mm (6.65 x 4.65 x 3.28 in)
Mounting Holes
160 x 80 mm (6.30 x 3.15 in)
Mounting Hole Size
Φ 5 mm
Terminal
10 mm2
Weight
0.95 Kg (2.09 lbs.)
Table 7-6 Mechanical Parameters
Page 26
25
PV Power – Conversion Efficiency Curve
Illumination Intensity: 1000W/m2 Temperature: 25°C
1. Solar Module MPP Voltage (17V) / Nominal System Voltage (12V)
2. Solar Module MPP Voltage (34V) / Nominal System Voltage (12V)
Page 27
26
3. Solar Module MPP Voltage (68V) / Nominal System Voltage (12V)
4. Solar Module MPP Voltage (34V) / Nominal System Voltage (24V)
Page 28
27
5. Solar Module MPP Voltage (68V) / Nominal System Voltage (24V)
Page 29
28
MPPT20CC Dimensions (mm)
Loading...