Renkus-Heinz ICL-F-RN, ICL-F-TRIP-RN, ICL-F-DUAL-RN, IC Live Gen 5 User Manual

IC Live
Digitally Steerable Line Array Loudspeaker Systems
IC Live Gen5
USERS MANUAL
Assembly & Installation Instructions
ICL-F-RN • ICL-F-DUAL-RN • ICL-F-TRIP-RN
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions
5. Do not use this apparatus near water. The apparatus shall not be exposed to dripping or splashing and no objects lled with liquids, such as vases, shall be placed on it.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accor­dance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Make sure the power cord remains readily accessible at all times.
12. The AC Power Cord is the AC Mains disconnect.
13. Only use attachments/accessories specied by the manufacturer.
14. Disconnect this apparatus during lightning storms or when unused for long periods of time.
15. Refer all servicing to qualied service personnel. Ser­vicing is required when the apparatus has been dam­aged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE
CAUTION: THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVIC­ING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the use to the presence of uninsulated "Dangerous Voltage" within the product's en­closure that may be of sufficient magnitude to constitute a risk of electric shock to hu­mans.
The exclamanation point, within an equilateral presence of important operating and mainte­nance (servicing) instructions in the literature accompanying the product.
CAUTION
RISK OF ELECTRONIC SHOCK:
OPEN ONLY IF QUALIFIED AS
SERVICE PERSONNEL
To reiterate the above warnings: servicing instructions
are for use by qualied personnel only. To avoid elec­tric shock, do not perform any servicing other than that contained in the Operation Instructions unless you are qualied to do so. Refer all servicing to qualied personnel.
Erklärung der graphischen SymboleExplanation of Graphical Symbols
Der Blitz mit nach untenzielendem Pfeil in einem gleichseitigen Dreieck weist den Benutzer auf das Vorhandensein einer unisolierten, "gefährlichen Spannung" im Gehäuse hin, die stark genug sein kann, einer Person einen gefährlichen elektrischen Schlag zu versetzen.
Das Ausrufezeichen in einem gleichseitigen Dreieck weist den Benutzer auf wichtige Betriebs- und Wartungsvorschriften in den beiliegenden Unterlagen des Gerätes hin.
VORSICHT
GEFAHR EINES ELEKTRISCHEN SCHLAGES:
NUR VON QUALIFIZIEREM WARTUNGSPERSONAL
ZU ÖFFNEN
Eindrigliche Warnung: Wartungsvorschriften dienen nur der Benutzung durch qualizieres Personal. Zur Vermeidung eines elektrischen Schlages keine anderen als die in den Betriebsvorschriften beschriebenen Wartungsarbeiten ausführen, es sei denn Sei sind dafür qualifiziert. Wartungsarbeiten auszuführen.
Your Iconyx Gen 5 Steerable Column Loudspeaker contains no user-serviceable
parts and all service should be referred to qualified service personnel.
IMPORTANT
TABLE OF CONTENTS PAGE
INTRODUCTION 4
ASSEMBLY INSTRUCTIONS 5
INSTALLATION 8
HARDWARE CONNECTIONS & INDICATORS 11
FIRMWARE UPDATE 12
SERVICING AND TROUBLESHOOTING 13
USER NOTES 15
IC Live
Users Manual
INTRODUCTION
Congratulations on your purchase of a Renkus-Heinz RHAON II Empowered, digitally steered IC Live Gen 5 loudspeaker system.
We hope you enjoy it.
Your IC Live Gen 5 loudspeaker was carefully tested and inspected before leaving our factory and should have arrived in perfect condition. Please carefully inspect the shipping carton(s) and loudspeaker(s) for any noticeable damage, and if any damage is found, immediately notify the shipping company. Only you, the consignee, may institute a claim with the carrier for any damage incurred during shipping. Be sure to save the carton(s) and all packing material for the carrier’s inspection. It is also a good idea to save the carton and packing material even though the loudspeaker arrived in good condition. If you should ever need to ship the loudspeaker, it should be shipped in its original factory packaging.
Technical Support
If you have any questions about Renkus-Heinz loudspeakers or encounter a problem designing, installing, setting up or operating a Renkus-Heinz system, please call our technical support staff at +1 949-588-9997 and ask the operator for technical support. Hours of operation are Monday through Friday from 8:00 AM to 5:00 PM US Pacic Time.
The latest information is always available online at http://www.renkus-heinz.com under the Service and Support heading. You will also nd a support request form there.
About RHAON II
Your IC Live Gen 5 digitally-controlled, steerable column loudspeaker is RHAON II Empowered. RHAON II (“rayon two”), the Renkus-Heinz System Manager Software, combines digital audio distribution with precise control and supervision of Renkus-Heinz self-powered loudspeakers. RHAON II uses standard Ethernet hardware and on-board DSP (digital signal
processing) to allow self-powered Renkus-Heinz loudspeakers to respond to user input in real time.
IMPORTANT
If you will be controlling/supervising your RHAON II empowered system with a laptop, do not close the laptop’s lid or allow your laptop to go to sleep (hibernate) during operation.
4
Users Manual
IC Live
General Information
Your RHAON II empowered loudspeaker’s amplier/DSP stores all conguration settings, including the input source selection, in non-volatile memory (settings will remain through a power cycle). Analog Input 1 has been pre-selected at the factory so you can use the loudspeaker as an ordinary self-powered loudspeaker out of the box. Just connect a line level audio signal to Analog Input 1 and connect the AC power. If the loudspeaker was previously put into its standby power mode or another input was selected, it will be necessary to connect it to a computer running RHAON II to change these settings or press the RESET button next to the RJ45 port (see page 11).
You will need a computer with a NIC (Network Interface Card) and Windows-based RHAON II software to change the input selection, beam steering or any of the other DSP settings. Once your DSP settings are stored in non-volatile memory, the computer can be disconnected from the network. You will need to connect a computer only when you want to change the settings or when you want to view the status of connected loudspeakers.
Renkus-Heinz engineering has programmed the on board DSP to optimize the loudspeaker’s performance and to ensure its safe operation. Replace the amplier module only with another unit that has been factory programmed for the same loud­speaker. Contact our Technical Support Department for details and assistance.
ASSEMBLY INSTRUCTIONS
To simplify shipping and handling, ICL-F-DUAL-RN and ICL-F-TRIP-RN arrays are shipped as modules in separate cartons and need to be assembled in the eld. All the hardware needed to assemble them is included in the cartons.
The HK-ICL series mounting hinge kit is included with your array and will be packed with the other hardware.
In the following instructions, the term “module” is used to refer to one of the 8-channel sec­tions of the nished assembly, which is called a column or a array.
Prepare an assembly area. Each module is 4 feet long, so you need a at surface at least 8 feet long to assemble the dual array; 12 feet for the triple array. We suggest covering the assembly area with a heavy cloth or some other soft material to prevent damaging the nish on the cabi­nets while assembling them.
Place the modules in their respective positions on the assembly area. Avoid resting the mod­ules on their grille. The modules are heavy and may deform the grille. Instead, rest the modules on their sides or back.
Note: The proper way of assembling the modules is shown in the illustration at right. Note that the horn sections of the ICL-F-RN and ICL-F-RS modules are joined together to build the dual. Proper orientation of the ICL-LM-F-RS module in “Triple” arrays is also important. Make sure
the LM module’s rear panel LED display is at the bottom of the module.
5
Loading...
+ 11 hidden pages