Renishaw EVOLUTE FASTRACK, EVOLUT RTLA50 Installation Manual

RSLM high accuracy linear encoder
Installation guide
M-6183-9040-02-A
EVOLUTE™ RTLA50/FASTRACK ™ absolute linear encoder system
Contents
Product compliance 1
Storage and handling 2
Installation drawing: EVOLUTE readhead 3
Installation drawing: EVOLUTE readhead (side cable outlet) 4
Installation drawing: RTLA50/FASTRACK (with adhesive datum clamp) 5
RTLA50/FASTRACK installation 6
RTLA50/FASTRACK: Scale datum 7
Readhead mounting/installation 8
Electrical connections 8
Scale technical specifications 8
General specifications 9
Output signals 9
EVOLUTE RTLA50/FASTRACK installation guide
Product compliance
C
Renishaw plc declares that EVOLUTE complies with the applicable standards and regulations.
A copy of the EC Declaration of Conformity is available on request.
FCC compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.
RoHS compliance
Compliant with EC directive 2011/65/EU (RoHS).
Patents
Features of Renishaw’s encoder systems and similar products are the subjects of the following patents and patent applications:
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor.
The packaging of our products contains the following materials and can be recycled.
Packaging Component Material ISO 11469 Recycling Guidance
Outer box Cardboard Not applicable Recyclable
Polypropylene PP Recyclable
Inserts Low Density Polyethylene Foam LDPE Recyclable
Cardboard Not applicable Recyclable
Bags High Density Polyethylene Bag HDPE Recyclable
Metalised Polyethylene PE Recyclable
EVOLUTE RTLA50/FASTRACK installation guide
1
CN1260551 US7499827 JP4008356 GB2395005 CN1314511 EP1469969 JP5002559 CN102197282 EP2350570 JP2012507028 US20110173832 KR20110088506 CN102388295 EP2417423 KR20120014902 US2012007980 CN102460077 EP2438402 US20120072169 KR20120026579 US8141265 EP2294363 CN102057256 JP2011524534 KR20110033204
Further information
Further information relating to the EVOLUTE encoder range can be found in the EVOLUTE Data sheets available from your local representative. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means without the written prior permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
EVOLUTE RTLA50/FASTRACK installation guide
2
Storage and handling
Storage
Operating
Humidity
RTLA50 – 50 mm FASTRACK – 200 mm
NOTE: Ensure self-adhesive tape is on outside of bend radius.
Minimum bend radius
N-heptane
CH3(CH2)5CH
3
Propan-2-ol
CH3CHOHCH
3
Scale and readhead
95% relative humidity (non-condensing) to EN 60068-2-78
Readhead
Readhead Standard +80 °C 0 °C
System Standard +80 °C