Renesas M16C, М29 User Manual

Quick Start
Renesas Starter Kit for M16C/29
1. Installation
Do not connect the E8a module until the software support has been installed.
1 Insert the CD into your computer’s CD-ROM drive. The CD should automatically run the installation program. If the installer does not start, browse to
the RSK directory from the CD root folder and double click on ‘setup.exe’. 2 The installer will ask you which language is to be used, please choose the appropriate one. 3 On the first screen of the installer proper, click <Next>. 4 The License Agreement will be shown, click <Yes>. 5 The next screen asks you to pick the world region – please select and click <Next>. 6 Select the RSK you wish to install and click <Next>. 7 The destination folders are specified on the next screens. It is recommended to accept the default settings. Click <Next> to continue. 8 Click <Next> on all screens until the Installation process commences. 9 After the installation the machine’s site code will be shown, this is not important at this stage, click <Next> then <Finish>. 10 The Auto-update dialog box will be launched. Configure the Auto-update settings dialog to allow the installation to be checked for available updates.
D006174_11_S01_V04
2. Connection
11 Now connect the E8a to J5/E8 on the RSK using the ribbon cable. 12 Connect the E8a module to a spare USB port.
The ‘Found New Hardware’ Wizard will appear. Please follow the steps below to install the drivers. Note that administrator privileges are required for a Windows™ 2000/XP machine. Do not use the Windows Update to locate the driver.
13 Verify the “Recommended” option is selected and click <Next>. 14 If using Windows XP, skip to step 16; otherwise click <Next>. 15 Click <Next> to install the driver. 16 Click <Finish> to close the wizard.
Note: The Windows driver signing dialog may be displayed. Please accept the driver to continue.
3. HEW Workspace
HEW integrates various tools such as compiler, assembler, debugger and editor into a common graphical user interface. To learn more on how to use HEW, open the HEW manual installed on your computer (Start Menu > All Programs > Renesas > High-performance Embedded Workshop > Manual Navigator).
17 Launch HEW from the Start Menu. (Start Menu > All Programs > Renesas > Renesas High-performance Embedded Workshop). 18 In the “Welcome” dialog box: Verify “Create New Workspace” is selected. Click <OK> 19 In the “New Project Workspace” dialog box: Set the “CPU Family” to “M16C”, and verify the “Tool chain” is set to “Renesas M16C Standard” .Select
“E8A_RSKM16C29” from the left hand pane.
20 Enter a name for the workspace. The project name will be automatically completed with the Workspace name. You can change this name to
‘Tutorial’ if required. Click <OK>. 21 On the “E8A_RSKM16C29– Step 1” window: Select “Tutorial” and click <Next>. 22 On the “E8A_RSKM16C29– Step 2” window: Click <Finish>.
23 On the Project Generator Information window: Click <OK>.
The project that is created has two configurations. The Release configuration can be used for the final release code version. The Debug configuration allows modifications to the configuration for debugging.
24 Select the Debug build configuration in the left hand drop down list on the
tool bar.
25 Click on the ‘Build’ icon to compile, assemble and link the
project.
D006174_11_S01_V04
Loading...
+ 2 hidden pages