Notice
1. All information included in this document is current as of the date this document is issued. Such information, however, is
subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please
confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to
additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website.
2. Renesas Electronics does not assume any liability for infringement of patents, copyrights, or other intellectual property rights
of third parties by or arising from the use of Renesas Electronics products or technical information described in this document.
No license, express, implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights
of Renesas Electronics or others.
3. You should not alter, modify, copy, or otherwise misappropriate any Renesas Electronics product, whether in whole or in part.
4. Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation of
semiconductor products and application examples. You are fully responsible for the incorporation of these circuits, software,
and information in the design of your equipment. Renesas Electronics assumes no responsibility for any losses incurred by
you or third parties arising from the use of these circuits, software, or information.
5. When exporting the products or technology described in this document, you should comply with the applicable export control
laws and regulations and follow the procedures required by such laws and regulations. You should not use Renesas
Electronics products or the technology described in this document for any purpose relating to military applications or use by
the military, including but not limited to the development of weapons of mass destruction. Renesas Electronics products and
technology may not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited
under any applicable domestic or foreign laws or regulations.
6. Renesas Electronics has used reasonable care in preparing the information included in this document, but Renesas Electronics
does not warrant that such informatio n is error free. Renesas Electronics assumes no liability whatsoever for any damages
incurred by you resulting from errors in or omissions from the information included herein.
7. Renesas Electronics products are classified according to the following three quality grades: “Standard”, “High Quality”, and
“Specific”. The recommended applications for each Renesas Electronics product depends on the product’s quality grade, as
indicated below. You must check the quality grade of each Renesas Electronics product before using it in a particular
application. You may not use any Renesas Electronics product for any application categorized as “Specific” without the prior
written consent of Renesas Electronics. Further, you may not use any Renesas Electronics product for any application for
which it is not intended without the prior written consent of Renesas Electronics. Renesas Electronics shall not be in any way
liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an
application categorized as “Specific” or for which the product is not intended where you have failed to obtain the prior written
consent of Renesas Electronics. The quality grade of each Renesas Electronics product is “Standard” unless otherwise
expressly specified in a Ren esas E lectronics data sheets or dat a books, etc.
“Standard”: Computers; office equipment; communications equipment; test and measurement equipment; audio and visual
equipment; home electron ic appliances; machine tools; personal electronic equipment; and industrial robots.
crime systems; safety equipment; and medical equipment not specifically designed for life support.
“Specific”: Aircraft; aerospace equipment; submersible repeaters; nuclear reactor control systems; medical equipment or
systems for life support (e.g. artificial life support devices or systems), surgical implantations, or healthcare
intervention (e.g. excision, etc.), and any other appl i cations or purposes that pose a d irect threat to human life.
8. You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics,
especially with respect to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation
characteristics, installation and other product characteristics. Renesas Electronics shall have no liability for malfunctions or
damages arising out of the use of Renesas Electronics products beyond such specified ranges.
9. Although Renesas Electronics endeavors to improve the quality and reliability of its products, semiconductor products have
specific characteristics such as t he occu rrence o f failure at a certai n rate an d malfunct io ns under cert ain u se con dition s. Further,
Renesas Electronics prod ucts are not subject to radiation resistance design. Please be sure to implement safety measures to
guard them against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a
Renesas Electronics product, such as safety design for hardware and software including but not limited to redundancy, fire
control and malfunction prevention, appropriate treatment for aging degradation or any other appropriate measures. Because
the evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or system
manufactured by you.
10. Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental
compatibility of each Renesas Electronics product. Please use Renesas Electronics products in compliance with all applicable
laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS
Directive. Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with
applicable laws and regulations.
11. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written consent of Renesas
Electronics.
12. Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this
document or Renesas Electronics products, or if you have any other inquiries.
(Note 1) “Renesas Electronics” as used in this document means Renesas Electronics Corporation an d also includes its majority-
owned subsidiaries.
(Note 2) “Renesas Electronics product(s)” means any product developed or manufactured by or for Renesas Electronics.
User’s Manual
M37906T-PRB
User’s Manual
Pod Probe for 7906 Group MCUs
Rev.1.00 2003.09
• AXS69204201 is a product of Matsushita Electric Works, Ltd.
• Renesas Technology Corporation and Renesas Solutions Corporation put the maximum effort into making semiconductor products better
and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal
injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate
measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention against any
malfunction or mishap.
• These materials are intended as a reference to assist our customers in the selection of the Renesas Technology product best suited to
the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas
Technology Corporation, Renesas Solutions Corporation or a third party.
• Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any damage, or infringement of any
third-party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples
contained in these materials.
• All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information
on products at the time of publication of these materials, and are subject to change by Renesas Technology Corporation and Renesas
Solutions Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact
Renesas Technology Corporation, Renesas Solutions Corporation or an authorized Renesas Technology product distributor for the latest
product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or
typographical errors. Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any damage,
liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Renesas Technology
Corporation and Renesas Solutions Corporation by various means, including the Renesas home page (http://www.renesas.com).
• When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms,
please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and
products. Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any damage, liability or
other loss resulting from the information contained herein.
• Renesas Technology semiconductors are not designed or manufactured for use in a device or system that is used under circumstances
in which human life is potentially at stake. Please contact Renesas Technology Corporation, Renesas Solutions Corporation or an
authorized Renesas Technology product distributor when considering the use of a product contained herein for any specific purposes,
such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
• The prior written approval of Renesas Technology Corporation and Renesas Solutions Corporation is necessary to reprint or reproduce
in whole or in part these materials.
• If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the
Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to
the export control laws and regulations of Japan and/or the country of destination is prohibited.
• Please contact Renesas Technology Corporation or Renesas Solutions Corporation for further details on these materials or the products
contained therein.
Keep safety first in your circuit designs!
Notes regarding these materials
• This product is a development supporting unit for use in your program development and evaluation stages. In mass-producing your
program you have finished developing, be sure to make a judgment on your own risk that it can be put to practical use by performing
integration test, evaluation, or some experiment else.
• In no event shall Renesas Solutions Corporation be liable for any consequence arising from the use of this product.
• Renesas Solutions Corporation strives to renovate or provide a workaround for product malfunction at some charge or without charge.
However, this does not necessarily mean that Renesas Solutions Corporation guarantees the renovation or the provision under any
circumstances.
• This product has been developed by assuming its use for program development and evaluation in laboratories. Therefore, it does not fall
under the application of Electrical Appliance and Material Safety Law and protection against electromagnetic interference when used in
Japan.
For inquiries about the contents of this document or product, fill in the text file the installer of the emulator debugger generates in the
following directory and email to your local distributor.
The M37906T-PRB is a pod probe for the 7906 Group of Renesas 16-bit microcomputers. The
M37906T-PRB is used by connecting to the PC4701 emulator main unit and the M37900T2-RPD-E
emulation pod main unit (option).
This manual mainly explains specifications and how to set up the M37906T-PRB. For detail
information about the emulator main unit, emulation pod main unit, and emulator debugger, refer to
each user's manual.
Emulator main unit: PC4701 User's Manual
Emulation pod main unit: M37900T2-RPD-E User's Manual
Emulator debugger: M3T-PD79 User's Manual
To check the components of this product, refer to "2.2 Package Components" (page 17) in this
manual. If there is any question or doubt about this product, contact your local distributor.
To use the product properly
Precautions for Safety:
•Both in this User's Manual and on the product itself, several icons are used to insure
proper handling of this product and also to prevent injuries to you or other persons,
or damage to your properties.
• The icons' graphic images and meanings are given in "Chapter 1 Precautions for
Safety". Be sure to read this chapter before using the product.
( 3 / 40 )
Contents
Chapter 1. Precautions for Safety ...........................................................................................7
1.1 Safety Symbols and Meanings ..............................................................................8
Warning for Installation...................................................................................9
Warning for Use Environment.........................................................................9
Caution to Be Taken for Modifying This Product ...........................................9
Cautions to Be Taken for This Product ...........................................................9
Notes on Target System .................................................................................10
Note on Reset Input from the Target System ................................................10
Notes on Stack Area ......................................................................................10
Note on MCU Files........................................................................................10
Notes on EMEM Dialog ................................................................................11
Note on Boot Mode........................................................................................11
Note on Breaks Used with Internal Resources ..............................................11
Note on Debug Monitor Area ........................................................................11
Note on Interface with the Target System .....................................................12
Notes on Service-Life of the MCU's Internal Flash ROM ............................12
Note on Debug Commands during STP/WIT Instruction .............................12
Notes on Disabling Watchdog Function ........................................................12
Note on Real-Time RAM Monitor ................................................................12
Note on Coverage Measurement....................................................................12
Note on Differences between Actual MCU and Emulator ............................13
6.4 How to Request for Repair..................................................................................37
( 5 / 40 )
MEMO
( 6 / 40 )
Chapter 1. Precautions for Safety
This chapter describes precautions for using this product safely and properly. For precautions for the emulator main unit,
the emulation pod main unit and the emulator debugger, refer to each user's manual included with your product.
1.1 Safety Symbols and Meanings ..................................................................................................... 8
WARNING
CAUTION
IMPORTANT
Warning for Installation...............................................................................................9
Warning for Use Environment.....................................................................................9
Caution to Be Taken for Modifying This Product ....................................................... 9
Cautions to Be Taken for This Product........................................................................ 9
Notes on Target System ............................................................................................. 10
Note on Reset Input from the Target System............................................................. 10
Notes on Stack Area................................................................................................... 10
Note on MCU Files....................................................................................................10
Notes on EMEM Dialog ............................................................................................ 11
Note on Boot Mode....................................................................................................11
Note on Breaks Used with Internal Resources ..........................................................11
Note on Debug Monitor Area .................................................................................... 11
Note on Interface with the Target System ................................................................. 12
Notes on Service-Life of the MCU's Internal Flash ROM ........................................12
Note on Debug Commands during STP/WIT Instruction.......................................... 12
Notes on Disabling Watchdog Function .................................................................... 12
Note on Real-Time RAM Monitor ............................................................................12
Note on Coverage Measurement................................................................................12
Note on Differences between Actual MCU and Emulator ........................................ 13
( 7 / 40 )
Chapter 1. Precautions for Safety
In both the user's manual and on the product itself, several icons are used to insure proper handling
of this product and also to prevent injuries to you or other persons, or damage to your properties.
This chapter describes the precautions which should be taken in order to use this product safely and
properly. Be sure to read this chapter before using this product.
1.1 Safety Symbols and Meanings
If the requirements shown in the "WARNING"
WARNING
CAUTION
IMPORTANT
In addition to the three above, the following are also used as appropriate.
sentences are ignored, the equipment may
cause serious personal injury or death.
If the requirements shown in the "CAUTION"
sentences are ignored, the equipment may
malfunction.
It means important information on using this
product.
means WARNING or CAUTION.
Example: CAUTION AGAINST AN ELECTRIC SHOCK
means PROHIBITION.
Example: DISASSEMBLY PROHIBITED
means A FORCIBLE ACTION.
Example:
The following pages describe the symbols "WARNING", "CAUTION", and "IMPORTANT".
UNPLUG THE POWER CABLE FROM THE RECEPTACLE.
( 8 / 40 )
WARNING
Warning for Installation:
• Do not set this product in water or areas of high humidity. Spilling water or some other liquid into
the main unit can cause an unrepairable damage.
Warning for Use Environment:
• This equipment is to be used in an environment with a maximum ambient temperature of 35°C. Care
should be taken that this temperature is not exceeded.
CAUTION
Caution to Be Taken for Modifying This Product:
• Do not disassemble or modify this product. Disassembling or modifying this product can cause
damage. Disassembling and modifying the product will void your warranty.
Cautions to Be Taken for This Product:
• Use caution when handling the main unit. Be careful not to apply a mechanical shock.
• Do not touch the connector pins of the emulator main unit and the target MCU connector pins
directly. Static electricity may damage the internal circuits.
• Do not pull the pod probe by the flexible cable (FLX120-RPD) for connecting to the emulator main
unit or the flexible cable (FLX100) for connecting the target system. The cable may cause a break.
•Flexible cable FLX120-RPD and FLX100 are different from earlier models. The slits make them
more flexible. However, excessive flexing or force may break conductors.
•Do not use inch-size screws for this equipment. The screws used in this equipment are all ISO
(meter-size) type screws. When replacing screws, use same type screws as equipped before.
( 9 / 40 )
Notes on Target System:
• The Vcc pin of emulator is connected to the target system to observe the voltage of the target system.
Therefore the emulator cannot supply the power to the target system. Design your system so that
the target system is powered separately.
• The voltage of the target system should be within the range of the MCU specification and suit to
the emulator MCUs as shown below:
- For 5.0V version MCUs: +4.5 to +5.5V
•Do not change the voltage of the target system after turning on the power.
• Before powering on your emulator system, check that the host machine, the PC4701, M37900T2RPD-E, the converter board and target system are all connected correctly. Next, turn on the power
to each equipment following the procedure below.
(1) Turn ON/OFF the target system and the PC4701 as simultaneously as possible.
(2) When the PC4701 and emulator debugger M3T-PD79 start up, check the target status LEDs
on the emulator main unit's front panel to see if this product is ready to operate.
• Is the power supplied?Check that target status LED (POWER) is ON.
• Is the clock supplied?Check that target status LED (CLOCK) is ON.
IMPORTANT
Note on Reset Input from the Target System:
• The reset input from the target system is accepted only while a user program is being executed (only
while the RUN status LED on the PC4701's front panel is lit).
Notes on Stack Area:
• With this product, a maximum 26 bytes of the user stack is consumed as work area.
• If the user stack does not have enough area, do not use areas which cannot be used as stack (SFR
area, RAM area which stores data, or ROM area) as work area. Using areas like this is a cause of
user program crashes and destabilized emulator control. Therefore, ensure the +26 byte maximum
capacity used by the user program as the user stack area.
Note on MCU Files:
• When starting up the emulator debugger M3T-PD79, select the MCU file corresponding to the
MCU which is going to be debugged by Init dialog (MCU files are included with the emulator
debugger M3T-PD79).
MCUMCU file name
M37906F8M37906F8.MCU
M37906M4M37906M4.MCU
( 10 / 40 )
Notes on EMEM Dialog:
• When setting the EMEM dialog box of emulator debugger M3T-PD79, pay attention to the
following:
(1) Processor Mode
Specify a processor mode for the target MCU to be debugged. With 7906 Group MCUs, only
the single-chip mode is specifiable. If the MD0 pin setting is not "L" level, emulator debugger
M3T-PD79 outputs an error message. In such a case, check the pin settings on the target
system.
(2) Emem Address
Allocate the 1MB emulation memory that is included in the emulation pod. For the 7906
Group, it is not necessary to set this because this group operates only in the single-chip mode.
(3) ROM Address
Disable the allocated emulation memory against writes by the user program. For the 7906
Group, it is not necessary to set this because this group operates only in the single-chip mode.
(4) DMA Address
In this dialog box, set a transfer area when using the MCU's DMA function, and executing 1bus transfer between emulation memory and the target system. For the 7906 Group, do not set
such areas because this group does not have the DMA function.
IMPORTANT
(5) 8-bit bus mode Address
When accessing external data buses in 8-bit width using the chip select wait controller when
BYTE pin = Low, set this address for the relevant area. For the 7906 Group, it is not necessary
to set this because this group operates only in the single-chip mode.
(6) Map Address
Set external or internal for the allocated emulation memory area. For the 7906 Group, it is not
necessary to set this because this group operates only in the single-chip mode.
Note on Boot Mode:
• It is not possible to debug the MCUs in the boot mode using this emulator system.
(The MD1 pin of the MCU is fixed to the "L" level.)
Note on Breaks Used with Internal Resources:
•H/W breaks cannot be used with internal resources (SFR, internal RAM and internal flash ROM)
when using emulator PC4701L.
Note on Debug Monitor Area:
• The debug monitor area is fixed to the "FF" bank. It cannot be set to other banks.