RENESAS Hitachi Electric, Hitachi XX User Manual

To all our customers
Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.
The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas Technology Corporation on April 1st 2003. These operations include microcomputer, logic, analog and discrete devices, and memory chips other than DRAMs (flash memory, SRAMs etc.) Accordingly, although Hitachi, Hitachi, Ltd., Hitachi Semiconductors, and other Hitachi brand names are mentioned in the document, these names have in fact all been changed to Renesas Technology Corp. Thank you for your understanding. Except for our corporate trademark, logo and corporate statement, no changes whatsoever have been made to the contents of the document, and these changes do not constitute any alteration to the contents of the document itself.
Renesas Technology Home Page: http://www.renesas.com
Renesas T echnology Corp. Customer Support Dept. April 1, 2003
Cautions
Keep safety first in your circuit designs!
1. Renesas Technology Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble ma y occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention against any malfunction or mishap .
Notes regarding these materials
1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corporation product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corporation or a third party.
2. Renesas Technology Corporation assumes no responsibility for any damage, or infringement of any third-party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials.
3. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Renesas Technology Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact Renesas Technology Corporation or an authorized Renesas Technology Corporation product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Renesas Technology Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Renesas Technology Corporation by various means, including the Renesas Technology Corporation Semiconductor home page (http://www.renesas.com).
4. When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Renesas Technology Corporation assumes no re sponsibility for any damage, liability or other loss resulting from the information contained herein.
5. Renesas Technology Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Renesas Technology Corporation or an authorized Renesas Technology Corporation product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
6. The prior written approval of Renesas Technology Corporation is necessary to reprint or reproduce in whole or in part these materials.
7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
8. Please contact Renesas Technology Corporation for further details on these materials or the products contained therein.
HN29V25611AT-50H
256M AND type Flash Memory
More than 16,057-sector (271,299,072-bit)
ADE-203-1334A (Z)
Rev. 1.0
Apr. 5, 2002

Description

The Hitachi HN29V25611AT-50H Series is a CMOS Flash Memory with AND type multi-level memory cells. It has fully automatic programming and erase capabilities with a single 3.0 V power supply. The functions are controlled by simple external commands. To fit the I/O card applications, the unit of programming and erase is as small as (2048 + 64) bytes. Initial available sectors of HN29V25611AT-50H are more than 16,057 (98% of all sector address) and less than 16,384 sectors.

Features

On-board single power supply (VCC): VCC = 2.7 V to 3.6 V
OrganizationAND Flash Memory: (2048 + 64) bytes × (More than 16,057 sectors)Data register: (2048 + 64) bytes
Multi-level memory cell2 bit/per memory cell
Automatic programmingSector program time: 1.0 ms (typ)System bus freeAddress, data latch functionInternal automatic program verify functionStatus data polling function
Automatic eraseSingle sector erase time: 1.0 ms (typ)System bus freeInternal automatic erase verify functionStatus data polling function
HN29V25611AT-50H
Erase modeSingle sector erase ((2048 + 64) byte unit)
Fast serial read access time:First access time: 50 µs (max)Serial access time: 50 ns (max)
Low power dissipation:I
= 2 mA (typ) (Read)
CC1
I
= 20 mA (max) (Read)
CC2
I
= 50 µA (max) (Standby)
SB2
II
The following architecture is required for data reliability.Error correction: more than 3-bit error correction per each sector readSpare sectors: 1.8% (290 sectors) (min) within usable sectors

Ordering Information

Type No. Available sector Package
HN29V25611AT-50H More than 16,057 sectors 12.0 × 20.00 mm
= 40 mA (max) (Erase/Program)
CC3/ICC4
= 20 µA (max) (Deep standby)
SB3
48-pin plastic TSOP I (TFP-48DA)
2
0.5 mm pitch
2

Pin Arrangement

V
CC
1
NC*
1
NC*
1
NC*
V
SS
RES
RDY/Busy
SC
OE
I/O0 I/O1 I/O2 I/O3 V
CC
V
SS
I/O4 I/O5 I/O6 I/O7
CDE
WE
CE
1
NC*
V
SS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
48-pin TSOP
(Top view)
HN29V25611AT-50H
48
NC
47
NC
46
NC
45
NC
44
NC
43
NC
42
NC
41
NC
40
NC
39
NC
38
NC
37
NC
36
NC
35
NC
34
NC
33
NC
32
NC
31
NC
30
NC
29
NC
28
NC
27
NC
26
NC
25
NC
Note: 1. This pin can be used as the VSS pin.
3
HN29V25611AT-50H

Pin Description

Pin name Function
I/O0 to I/O7 Input/output
CE Chip enable OE Output enable WE Write enable CDE Command data enable
1
VCC*
1
VSS* RDY/Busy Ready/Busy RES Reset SC Serial clock NC No connection
Note: 1. All VCC and VSS pins should be connected to a common power supply and a ground, respectively.
Power supply Ground
4

Block Diagram

HN29V25611AT-50H
2048 + 64
I/O0
to
I/O7
RDY/Busy
V
CC
V
SS
Sector address buffer
• •
• Multiplexer
• • • • •
Data input buffer
X-decoder
Input
• data
• control
Y-address counter
16384 × (2048 + 64) × 8
memory matrix
Data register (2048 + 64)
Y-gating
Y-decoder
16057 - 16384
Data output buffer
CE OE
WE
SC
RES CDE
Control signal buffer
Read/Program/Erase control
5
HN29V25611AT-50H

Memory Map and Address

Sector address
3FFFH 3FFEH
3FFDH
0002H
0001H
0000H
000H
2048 bytes 2048 bytes 2048 bytes
2048 bytes
2048 bytes 2048 bytes
64 bytes 64 bytes
64 bytes
64 bytes
64 bytes 64 bytes
800H 83FH
1
16057 - 16384 sectors *
Column address
2048 + 64 bytes
Control bytes
I/O6
I/O5
I/O4
I/O3
I/O2
I/O1
Address Sector address
Column address
Notes: 1. Some failed sectors may exist in the device. The failed sectors can be recognized
by reading the sector valid data written in a part of the column address 800 to 83F (The specific address is TBD.). The sector valid data must be read and kept outside of the sector before the sector erase. When the sector is programmed, the sector valid data should be written back to the sector.
2. An × means "Don't care". The pin level can be set to either V to DC characteristics.
Cycles SA (1): First cycle SA (2): Second cycle CA (1): First cycle CA (2): Second cycle
I/O0
A0 A8 A0 A8
A1 A9 A1 A9
A2
A10
A2
A10
A3
A11
A3
A11
A5
A4
A13
A12
A5
A4
×
×
or VIH, referred
IL
A6
×*
A6
I/O7
A7
2
×
A7
×
×
6
HN29V25611AT-50H

Pin Function

CE: CE is used to select the device. The status returns to the standby at the rising edge of CE in the reading operation. However, the status does not return to the standby at the rising edge of CE in the busy state in programming and erase operation.
OE: Memory data and status register data can be read, when OE is VIL.
WE: Commands and address are latched at the rising edge of WE.
SC: Programming and reading data is latched at the rising edge of SC.
RES: RES pin must be kept at the V in the memory is protected against unintentional erase and programming. RES must be kept at the V
(VSS ± 0.2 V) level when VCC is turned on and off. In this way, data
ILR
IHR
(V
CC
± 0.2 V) level during any operations such as programming, erase and read.
CDE: Commands and data are latched when CDE is VIL and address is latched when CDE is VIH.
RDY/Busy: The RDY/Busy indicates the program/erase status of the flash memory. The RDY/ Busy signal
is initially at a high impedance state. It turns to a VOL level after the (40H) command in programming operation or the (B0H) command in erase operation. After the erase or programming operation finishes, the RDY/Busy signal turns back to the high impedance state.
I/O0 to I/O7: The I/O pins are used to input data, address and command, and are used to output memory data and status register data.

Mode Selection

Mode CE OE WE SC RES CDE RDY/Busy*3I/O0 to I/O7
4
Deep standby ×* Standby V Output disable V Status register read* Command write*
1
2
×××V ×××V
IH
V
IL
IH
V
V
IL
IL
V
V
IL
IH
V
× V
IH
V
× V
IH
V
V
IL
IL
Notes: 1. Default mode after the power on is the status register read mode (refer to status transition). From
I/O0 to I/O7 pins output the status, when CE = V condition).
2. Refer to the command definition. Data can be read, programmed and erased after commands are written in this mode.
3. The RDY/Busy bus should be pulled up to V
to maintain the VOH level while the RDY/Busy pin
CC
outputs a high impedance.
4. An × means “Don’t care”. The pin level can be set to either V
× V
ILR
× V
IHR
× V
IHR
× V
IHR
V
IHRVIL
and OE = VIL (conventional read operation
IL
OH
OH
OH
OH
V
OH
or VIH referred to DC characteristics.
IL
High-Z High-Z High-Z Status register outputs Din
7
HN29V25611AT-50H

Command Definition*

1, 2
First bus cycle Second bus cycle
Command
Bus cycles
Operation
3
mode*
Data in Operation
mode
Data in Data out
Read Serial read (1) (Without CA) 3 Write 00H Write SA (1)*
(With CA) 3 + 2h*6Write 00H Write SA (1)* Serial read (2) 3 Write F0H Write SA (1)* Read identifier codes 1 Write 90H Read ID* Data recovery read 1 Write 01H Read Recovery
Auto erase Single sector 4 Write 20H Write SA (1)* Auto program Program (1) (Without
CA*
7
)
4 Write 10H Write SA (1)*
(With CA*7) 4 + 2h*6Write 10H Write SA (1)* Program (2)*
10
4 Write 1FH Write SA (1)* Program (3) (Control bytes)*74 Write 0FH Write SA (1)* Program (4) (WithoutCA*7) 4 Write 11H Write SA (1)*
(With CA*7) 4 + 2h*6Write 11H Write SA (1)* Reset 1 Write FFH Clear status register 1 Write 50H Data recovery write 4 Write 12H Write SA (1)*
4
4
4
8, 9
data
4
4
4
4
4
4
4
4
8
Third bus cycle Fourth bus cycle
Command
Bus cycles
Operation mode
Data in Operation
Read Serial read (1) (Without CA) 3 Write SA (2)*
(With CA) 3 + 2h*6Write SA (2)*
Serial read (2) 3 Write SA (2)* Read identifier codes 1
Data recovery read 1 Auto erase Single sector 4 Write SA (2)* Auto program Program (1) (Without
CA*
7
)
4 Write SA (2)*
(With CA*7) 4 + 2h*6Write SA (2)*
Program (2)*
10
4 Write SA (2)* Program (3) (Control bytes)*74 Write SA (2)* Program (4) (WithoutCA*7) 4 Write SA (2)*
(With CA*7) 4 + 2h*6Write SA (2)* Reset 1 Clear status register 1 Data recovery write 4 Write SA (2)*
HN29V25611AT-50H
Data in
mode
4
4
Write CA (1)*
4
4
Write B0H*
4
Write 40H
4
Write CA (1)
4
Write 40H
4
Write 40H
4
Write 40H
4
Write CA (1)
4
Write 40H
5
11
*11, 12
*11, 12
*11, 12
*11, 12
*11, 12
9
HN29V25611AT-50H
Fifth bus cycle Sixth bus cycle
Bus
Command
cycles
Read Serial read (1) (Without CA) 3
(With CA) 3 + 2h*6Write CA (2)*
Serial read (2) 3 Read identifier codes 1
Data recovery read 1 Auto erase Single sector 4 Auto program Program (1) (Without
CA*
7
)
4
(With CA*7) 4 + 2h*6Write CA (2)*
Program (2)*
10
4 Program (3) (Control bytes)*74 Program (4) (WithoutCA*7)4
(With CA*7) 4 + 2h*6Write CA (2) Write 40H Reset 1 Clear status register 1 Data recovery write 4
Notes: 1. Commands and sector address are latched at rising edge of WE pulses. Program data is latched
at rising edge of SC pulses.
2. The chip is in the read status register mode when RES is set to V
3. Refer to the command read and write mode in mode selection.
4. SA (1) = Sector address (A0 to A7), SA (2) = Sector address (A8 to A13).
5. CA (1) = Column address (A0 to A7), CA (2) = Column address (A8 to A11). (0 A11 to A0 83FH)
6. The variable h is the input number of times of set of CA (1) and CA (2) (1 h 2048 + 64).
Set of CA (1) and CA (2) can be input without limitation.
7. By using program (1) and (3), data can additionally be programmed maximum 15 times for each
sector before erase.
8. ID = Identifier code; Manufacturer code (07H), Device code (9AH).
9. The manufacturer identifier code is output when CDE is low and the device identifier code is output
when CDE is high.
10.Before program (2) operations, data in the programmed sector must be erased.
11.No commands can be written during auto program and erase (when the RDY/Busy pin outputs a
V
).
OL
12.The fourth or sixth cycle of the auto program comes after the program data input is complete.
Operation mode
Data in Operation
mode
5
5
Write 40H
first time after the power up.
IHR
Data in
*11, 12
*11, 12
10
HN29V25611AT-50H

Mode Description

Read
Serial Read (1): Memory data D0 to D2111 in the sector of address SA is sequentially read. Output data is
not valid after the number of the SC pulse exceeds 2112. When CA is input, memory data D (m) to D (m + j) in the sector of address SA is sequentially read. Then output data is not valid after the number of the SC pulse exceeds (2112 to m). The mode turns back to the standby mode at any time when CE is VIH.
Serial Read (2): Memory data D2048 to D2111 in the sector of address SA is sequentially read. Output data is not valid after the number of the SC pulse exceeds 64. The mode turns back to the standby mode at any time when CE is VIH.
Automatic Erase
Single Sector Erase: Memory data D0 to D2111 in the sector of address SA is erased automatically by
internal control circuits. After the sector erase starts, the erasure completion can be checked through the RDY/Busy signal and status data polling. All the bits in the sector are "1" after the erase. The sector valid data stored in a part of memory data D2048 to D2111 must be read and kept outside of the sector before the sector erase.
Automatic Program
Program (1): Program data PD0 to PD2111 is programmed into the sector of address SA automatically by
internal control circuits. When CA is input, program data PD (m) to PD (m + j) is programmed from CA into the sector of address SA automatically by internal control circuits. By using program (1), data can additionally be programed 15 times for each sector before the following erase. When the column is programmed, the data of the column must be [FF]. After the programming starts, the program completion can be checked through the RDY/Busy signal and status data polling. Programmed bits in the sector turn from "1" to "0" when they are programmed. The sector valid data should be included in the program data PD2048 to PD2111.
Program (2): Program data PD0 to PD2111 is programmed into the sector of address SA automatically by internal control circuits. After the programming starts, the program completion can be checked through the RDY/Busy signal and status data polling. Programmed bits in the sector turn from "1" to "0" when they are programmed. The sector must be erased before programming. The sector valid data should be included in the program data PD2048 to PD2111.
Program (3): Program data PD2048 to PD2111 is programmed into the sector of address SA automatically by internal control circuits. By using program (3), data can additionally be programed 15 times for each sector befor the following erase. When the column is programmed, the data of the column must be [FF]. After the programming starts, the program completion can be checked through the RDY/Busy signal and status data polling. Programmed bits in the sector turn from "1" to "0" when they are programmed.
11
HN29V25611AT-50H
Program (4): Program data PD0 to PD2111 is programmed into the sector of address SA automatically by
internal control circuits. When CA is input, program data PD (m) to PD (m + j) is programmed from CA into the sector of address SA automatically by internal control circuits. By using program (4), data can be rewritten for each sector before the following erase. So the column data before programming operation are either "1" or "0". In this mode, E/W number of times must be counted whenever program (4) execute. After the programming starts, the program completion can be checked through the RDY/Busy signal and status data polling. The sector valid data should be included in the program data PD2048 to PD2111.
2111
16383
Sector address
Memory array
0
0
Serial read (2) Program (3)
2048
Register
2111
16383
Sector address
Memory array
0
0
Register
Serial read (1) (Without CA) Program (1) (Without CA) Program (2)
2111
16383
Sector address
Memory array
0
0
Column address
Register
Serial read (1) (With CA) Program (1) (With CA)
Status Register Read
The status returns to the status register read mode from standby mode, when CE and OE is VIL. In the status register read mode, I/O pins output the same operation status as in the status data polling defined in the function description.
Identifier Read
The manufacturer and device identifier code can be read in the identifier read mode. The manufacturer and device identifier code is selected with CDE VIL and VIH, respectively.
12
HN29V25611AT-50H
Data Recovery Read
When the programming was an error, the program data can be read by using data recovery read. When an additional programming was an error, the data compounded of the program data and the origin data in the sector address SA can be read. Output data are not valid after the number of SA pulse exeeds 2112. The mode turns back to the standby mode at any time when CE is VIH. The read data are invalid when addresses are latched at a rising edge of WE pulse after the data recovery read command is written.
Data Recovery Write
When the programming into a sector of address SA was an error, the program data can be rewritten automatically by internal control circuit into the other selected sector of address SA’. Since the data recovery write mode is internally Program (4) mode, rewritten sector of address SA’ needs no sector erase before rewrite. After the data recovery write mode starts, the program completion can be checked through the RDY/Busy signal and the status data polling.
13
Loading...
+ 32 hidden pages