Renesas H8SX-1520 User Manual

REJ10B0173-0100
Renesas Microcomputer Development Environment System
H8SX/1520 Group FP-100M
User System Interface Cable
User’s Manual
HS1527ECH61H
Rev.1.00 Revision Date: Jan. 12, 2005

Keep safety first in your circuit designs!

1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention against any malfunction or mishap.

Notes regarding these materials

1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corp. or a third party.
2. Renesas Technology Corp. assumes no responsibility for any damage, or infringement of any third­party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials.
3. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Renesas Technology Corp. without notice due to product improvements or other reasons. It is therefore recommended that customers contact Renesas Technology Corp. or an authorized Renesas Technology Corp. product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Renesas Technology Corp. assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Renesas Technology Corp. by various means, including the Renesas Technology Corp. Semiconductor home page (http://www.renesas.com).
4. When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Renesas Technology Corp. assumes no responsibility for any damage, liability or other loss resulting from the information contained herein.
5. Renesas Technology Corp. semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Renesas Technology Corp. or an authorized Renesas Technology Corp. product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in whole or in part these materials.
7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
8. Please contact Renesas Technology Corp. for further details on these materials or the products contained therein.

Preface

The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an FP-100M package for the H8SX/1520 group MCU on the user system.
i

Contents

Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station..........................................3
2.2 Connecting User System Interface Cable to User System.................................................5
2.2.1 Installing IC Socket..............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head............................................................................................6
2.2.4 Fastening Cable Head ..........................................................................................6
2.2.5 Fastening Cable Body..........................................................................................8
2.3 Recommended Dimensions for User System Mount Pad..................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable..............................11
Section 3 Installing the MCU to the User System.............................................12
Section 4 Verifying Operation...........................................................................14
Section 5 Notice.................................................................................................15
ii

Section 1 Configuration

CAUTION
Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package IC socket on the user system.
Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP-100M package.
To emulator station
Cable body
Screws (M2.6 x 12 mm)
Screws (M2.6 x 6 mm) with flat washers
Socket cover
IC socket
User system
with flat washers (for fastening cable head)
Figure 1 HS1527ECH61H User System Interface Cable
Cable head
1
Table 1 lists the H S1527EC H 61H components. Please make sure y ou h a v e al l of t h es e components when unpacking.
Table 1 HS1527ECH61H Components
No. Component Quantity Remarks
1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-100M package 4 Socket cover 1 For installing an FP-100M packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.6 x 6 mm) 4 For installing an FP-100M packaged MCU (with
7 Documentation 1 User’s manual for HS1527ECH61H (this manual)
four flat washers)
2

Section 2 Connection Procedures

2.1 Connecting User System Interface Cable to Emulator Station

WARNING
Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2. The user system interface cable dedicated to the emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface cable, apply force only in the direction suitable for connection or removal, while making sure not to bend or twist the cable or connectors. Otherwise, the connectors will be damaged.