REJ10B0173-0100
Renesas Microcomputer Development Environment System
H8SX/1520 Group FP-100M
User System Interface Cable
User’s Manual
HS1527ECH61H
Rev.1.00
Revision Date: Jan. 12, 2005
Keep safety first in your circuit designs!
1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and
more reliable, but there is always the possibility that trouble may occur with them. Trouble with
semiconductors may lead to personal injury, fire or property damage.
Remember to give due consideration to safety when making your circuit designs, with appropriate
measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or
(iii) prevention against any malfunction or mishap.
Notes regarding these materials
1. These materials are intended as a reference to assist our customers in the selection of the Renesas
Technology Corp. product best suited to the customer's application; they do not convey any license
under any intellectual property rights, or any other rights, belonging to Renesas Technology Corp. or
a third party.
2. Renesas Technology Corp. assumes no responsibility for any damage, or infringement of any thirdparty's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or
circuit application examples contained in these materials.
3. All information contained in these materials, including product data, diagrams, charts, programs and
algorithms represents information on products at the time of publication of these materials, and are
subject to change by Renesas Technology Corp. without notice due to product improvements or
other reasons. It is therefore recommended that customers contact Renesas Technology Corp. or
an authorized Renesas Technology Corp. product distributor for the latest product information
before purchasing a product listed herein.
The information described here may contain technical inaccuracies or typographical errors.
Renesas Technology Corp. assumes no responsibility for any damage, liability, or other loss rising
from these inaccuracies or errors.
Please also pay attention to information published by Renesas Technology Corp. by various means,
including the Renesas Technology Corp. Semiconductor home page (http://www.renesas.com).
4. When using any or all of the information contained in these materials, including product data,
diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total
system before making a final decision on the applicability of the information and products. Renesas
Technology Corp. assumes no responsibility for any damage, liability or other loss resulting from the
information contained herein.
5. Renesas Technology Corp. semiconductors are not designed or manufactured for use in a device or
system that is used under circumstances in which human life is potentially at stake. Please contact
Renesas Technology Corp. or an authorized Renesas Technology Corp. product distributor when
considering the use of a product contained herein for any specific purposes, such as apparatus or
systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in
whole or in part these materials.
7. If these products or technologies are subject to the Japanese export control restrictions, they must
be exported under a license from the Japanese government and cannot be imported into a country
other than the approved destination.
Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the
country of destination is prohibited.
8. Please contact Renesas Technology Corp. for further details on these materials or the products
contained therein.
Preface
The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H
emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an
FP-100M package for the H8SX/1520 group MCU on the user system.
i
Contents
Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station..........................................3
2.2 Connecting User System Interface Cable to User System.................................................5
2.2.1 Installing IC Socket..............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head............................................................................................6
2.2.4 Fastening Cable Head ..........................................................................................6
2.2.5 Fastening Cable Body..........................................................................................8
2.3 Recommended Dimensions for User System Mount Pad..................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable..............................11
Section 3 Installing the MCU to the User System.............................................12
Section 4 Verifying Operation...........................................................................14
Section 5 Notice.................................................................................................15
ii
Section 1 Configuration
CAUTION
Use an IC149-100-054-B51 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package
IC socket on the user system.
Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the
FP-100M package.
To emulator station
Cable body
Screws (M2.6 x 12 mm)
Screws (M2.6 x 6 mm)
with flat washers
Socket cover
IC socket
User system
with flat washers
(for fastening cable head)
Figure 1 HS1527ECH61H User System Interface Cable
Cable head
1
Table 1 lists the H S1527EC H 61H components. Please make sure y ou h a v e al l of t h es e components
when unpacking.
Table 1 HS1527ECH61H Components
No. Component Quantity Remarks
1 Cable body 1 Cable
2 Cable head 1
3 IC socket 1 For the FP-100M package
4 Socket cover 1 For installing an FP-100M packaged MCU
5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers)
6 Screws (M2.6 x 6 mm) 4 For installing an FP-100M packaged MCU (with
7 Documentation 1 User’s manual for HS1527ECH61H (this manual)
four flat washers)
2
Section 2 Connection Procedures
2.1 Connecting User System Interface Cable to Emulator Station
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are
correctly aligned.
2. The user system interface cable dedicated to the
emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface
cable, apply force only in the direction suitable for
connection or removal, while making sure not to bend or
twist the cable or connectors. Otherwise, the connectors
will be damaged.
3