Renesas H8SX-1520 User Manual

REJ10B0173-0100
Renesas Microcomputer Development Environment System
H8SX/1520 Group FP-100M
User System Interface Cable
User’s Manual
HS1527ECH61H
Rev.1.00 Revision Date: Jan. 12, 2005

Keep safety first in your circuit designs!

1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention against any malfunction or mishap.

Notes regarding these materials

1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corp. or a third party.
2. Renesas Technology Corp. assumes no responsibility for any damage, or infringement of any third­party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials.
3. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Renesas Technology Corp. without notice due to product improvements or other reasons. It is therefore recommended that customers contact Renesas Technology Corp. or an authorized Renesas Technology Corp. product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Renesas Technology Corp. assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Renesas Technology Corp. by various means, including the Renesas Technology Corp. Semiconductor home page (http://www.renesas.com).
4. When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Renesas Technology Corp. assumes no responsibility for any damage, liability or other loss resulting from the information contained herein.
5. Renesas Technology Corp. semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Renesas Technology Corp. or an authorized Renesas Technology Corp. product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in whole or in part these materials.
7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
8. Please contact Renesas Technology Corp. for further details on these materials or the products contained therein.

Preface

The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an FP-100M package for the H8SX/1520 group MCU on the user system.
i

Contents

Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station..........................................3
2.2 Connecting User System Interface Cable to User System.................................................5
2.2.1 Installing IC Socket..............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head............................................................................................6
2.2.4 Fastening Cable Head ..........................................................................................6
2.2.5 Fastening Cable Body..........................................................................................8
2.3 Recommended Dimensions for User System Mount Pad..................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable..............................11
Section 3 Installing the MCU to the User System.............................................12
Section 4 Verifying Operation...........................................................................14
Section 5 Notice.................................................................................................15
ii

Section 1 Configuration

CAUTION
Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package IC socket on the user system.
Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP-100M package.
To emulator station
Cable body
Screws (M2.6 x 12 mm)
Screws (M2.6 x 6 mm) with flat washers
Socket cover
IC socket
User system
with flat washers (for fastening cable head)
Figure 1 HS1527ECH61H User System Interface Cable
Cable head
1
Table 1 lists the H S1527EC H 61H components. Please make sure y ou h a v e al l of t h es e components when unpacking.
Table 1 HS1527ECH61H Components
No. Component Quantity Remarks
1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-100M package 4 Socket cover 1 For installing an FP-100M packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.6 x 6 mm) 4 For installing an FP-100M packaged MCU (with
7 Documentation 1 User’s manual for HS1527ECH61H (this manual)
four flat washers)
2

Section 2 Connection Procedures

2.1 Connecting User System Interface Cable to Emulator Station

WARNING
Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2. The user system interface cable dedicated to the emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface cable, apply force only in the direction suitable for connection or removal, while making sure not to bend or twist the cable or connectors. Otherwise, the connectors will be damaged.
3
2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2).
E6000H
RENESAS
HS1527KEPH60H emulator station
Cable body connector
User system interface cable
Figure 2 Example of the HS1527KEPH60H Emulator Station
4

2.2 Connecting User System Interface Cable to User System

WARNING
Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
To connect the cable head to the user system, follow the instructions below.

2.2.1 Installing IC Socket

After checking the location of pin 1 on the IC socket, apply epoxy resin adh esive to th e bottom of th e IC socket for an FP-100M package, and fasten it to the user system before soldering.

2.2.2 Soldering IC Socket

After fastening, solder the IC socket for an FP-100M package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.)
5

2.2.3 Inserting Cable Head

CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an FP-100M package on the user system with pin 1 on the user system interf ace cable head, and in sert the u ser sy s tem interf ace cable head into th e IC socket on the user system, as shown in figure 3.

2.2.4 Fastening Cable Head

CAUTION
1. Use a Philips-type screwdriver whose head matches the screw head.
2. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might have occurred in the solder. Check conduction with a tester and re-solder the IC socket if necessary.
6
Fasten the user system interface cable head to the IC socket for an FP-100M package on the user system with the four screws (M2.6
12 mm; w ith f our flat wa shers) prov ided. Each screw should be
x
tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the compo nents.
Screws (M2.6 x 12 mm) with flat washers
Cable head
Pin 1
IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.)
User system
Figure 3 Connecting User System Interface Cable to User System
7

2.2.5 Fastening Cable Body

Connect the cable body to the cable head.
Cable body
User system
Removing
Push the remove jigs
Remove jig
Cable head
Figure 4 Fastening Cable Body
8

2.3 Recommended Dimensions for User System Mount Pad

Figure 5 shows th e recommended dimensions for the moun t pad (footprint) for the user sys tem with an IC socket for an FP-100M package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dim ens ions in figu re 5 are somewh at different from those of the actual chip's mount pad.
17.10 (min.)
13.80 (max.)
0.5 x 24 = 12.00 ± 0.05
0.50 ± 0.05 0.30 ± 0.05
0.50 ± 0.05
Unit: mm
Figure 5 Recommended Dimensions for Mount Pad
0.5 x 24 = 12.00 ± 0.05
9

2.4 Dimensions for User System Interface Cable Head

The dimensions for the user system interface cable head are shown in figure 6.
66.04
29.5
29.5
17.0
17.0
63.50
Unit: mm Tolerance: ±0.5 mm
10
Figure 6 Dimensions for User System Interface Cable Head

2.5 Resulting Dimensions after Connecting User System Interface Cable

The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7.
Cable head
16.0 21.5
IC socket
User system
(IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co. Ltd.)
Figure 7 Resulting Dimensions after Connecting User System Interface Cable
Unit: mm Tolerance: ±0.5 mm
11

Section 3 Installing the MCU to the User System

CAUTION
1. Check the location of pin 1 before inserting.
2. Use a Philips-type screwdriver whose head matches the screw head.
3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have occurred in the solder. Check conduction with a tester and re-solder the IC socket if necessary.
Check the location of pin 1 bef ore insertin g the MCU into the IC socket on the u ser sy stem , as show n in figure 8. After inserting th e MCU, f asten th e socket cover with the provided four screws (M2.6 6 mm; with four flat washers). Take special care, such as manually securing the IC socket soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting the components.
x
12
User system
Screws (M2.6 x 6 mm) with flat washers
Socket cover
MCU
Pin 1
IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.)
Figure 8 Installing MCU to User System
13

Section 4 Verifying Operation

1. Turn on the em ulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE).
2. Verify the user system interface cable connections by checking the pin states with the CHECK command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1.
3. The emulator connected to th is u s er system interface cable supports three kinds of clock s ources as the MCU clock: an em ulator in ternal clock, an extern al clock on th e user s y stem , and a cry s tal oscillator to be mounted on the EV-chip board. For details, refer to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE).
To use the emulator internal clock
Select the clock in the emulator by using the CLOCK command (emulator command).
To use the external clock on the user system
Select the external clock with the CLOCK command (emulator command). Supply the
external clock from the user system to the emulator by inputting the external clock from the EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and XTAL terminals. For details, refer to the H8SX/1520 Group Hardware Manual.
To use the crystal oscillator mounted on the EV-chip board
Install a crystal oscillator into the crystal oscillator terminals on the EV-chip board.
Figure 9 shows the oscillator circuit on the u ser system interface cable.
14
1 M
HCU04
To E6000H
HCU04
270
EXTAL XTAL
emulator
Figure 9 Oscillator Circuit

Section 5 Notice

1. Make su re that pin 1 on th e user sy stem IC socket is correctly alig ned with pin 1 on the cable head before inserting the cable head into the user system IC socket.
2. This user system interface cable is s pecifically desig ned for the HS1527KEPH60H em ulator. Do not use this cable with any other emulator station.
3. To prevent breaking of wires in the cable body, do not place heavy or sh arp metal objects on the user system interface cable.
4. While the emulator station is connected to the user system with the user system interface cable, force must not be applied to the cable head. Place the emulator station, user system interface cable, and user system as shown in the example in figure 10.
Place components so that the cable body and cable head are
Emulator's front-end unit
Figure 10 User System Interface Cable Location Example
5. The P1 short connector is used for testing. Do not remove the jumper pin that is inserted in
the side of pins 1 and 2.
parallel to the user system.
Cable
User system
Cable head is parallel to emulator station
Cable head is parallel to user system
13
P4
31
P1
Figure 11 P1 and P4 Short Connectors
15
6. A level-shift circuit with AVcc0 and AVcc1 is mounted on the user system interface cable, as shown in figure 12. At shipment, the jumper pin is inserted in the side of pins 1 and 2 of the P4 short connector. For details on the diff erences betw een the target MCU and th e emulator, ref er to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges of input voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual.
CAUTION
Insert the jumper pin in the P4 short connector so that the higher voltage between AVcc0 and AVcc1 is selected. Select either AVcc0 or AVcc1 when their potentials are the same. Do not use the emulator without jumper pins.
User system interface Emulator station
AVcc0
AVss AVcc1
AVss
5 V
1.03 k +
-
2 k
5 V
1.03 k +
-
2 k
Settings of short connector: Between pins 1 and 2: AVcc0 Between pins 2 and 3: AVcc1
Figure 12 Level-shift Circuit with AVcc0 and AVcc1
1
3P4
UVREF3
AVcc of MCU of the emulator station
UVREF1
16
Renesas Microcomputer Development Environment System User's Manual H8SX/1520 Group FP-100M User System Interface Cable
Publication Date: Rev.1.00, January 12, 2005 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd.
2005. Renesas Technology Corp., All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan
RENESAS SALES OFFICES
Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc.
450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501
Renesas Technology Europe Limited
Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K. Tel: <44> (1628) 585-100, Fax: <44> (1628) 585-900
Renesas Technology Hong Kong Ltd.
7th Floor, North Tower, World Finance Centre, Harbour City, 1 Canton Road, Tsimshatsui, Kowloon, Hong Kong Tel: <852> 2265-6688, Fax: <852> 2730-6071
Renesas Technology Taiwan Co., Ltd.
10th Floor, No.99, Fushing North Road, Taipei, Taiwan Tel: <886> (2) 2715-2888, Fax: <886> (2) 2713-2999
Renesas Technology (Shanghai) Co., Ltd.
Unit2607 Ruijing Building, No.205 Maoming Road (S), Shanghai 200020, China Tel: <86> (21) 6472-1001, Fax: <86> (21) 6415-2952
Renesas Technology Singapore Pte. Ltd.
1 Harbour Front Avenue, #06-10, Keppel Bay Tower, Singapore 098632 Tel: <65> 6213-0200, Fax: <65> 6278-8001
http://www.renesas.com
Colophon 2.0
H8SX/1520 Group FP-100M
User System Interface Cable
HS1527ECH61H User’ s Manu al