1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s
patent, copyright, trademark, or other intellectual property rights for information contained in
this document. Renesas bears no responsibility for problems that may arise with third party’s
rights, including intellectual property rights, in connect ion with use of the information contained
in this document.
2. Products and product specifications may be subject to change without notice. Confirm that you
have received the latest product standards or specifications before final design, purchase or use.
3. Renesas makes every attempt to ensure that its products are of high quality and reliability.
However, contact Renesas’s sales office before using the product in an application t hat demands
especially high quality and reliability or where its failure or malfunction may directly threaten
human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power,
combustion control, transportation, traffic, safety equipment or medical equipment for life
support.
4. Design your application so that the product is used within the ranges guaranteed by Renesas
particularly for maximum rating, operating supply voltage range, heat radiation characteristics,
installation conditions and other characteristics. Renesas bears no responsibility for failure or
damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider
normally foreseeable failure rates or failure modes in semiconductor devices and employ
systemic measures such as fail-safes, so that the equipment incorporating Renesas product does
not cause bodily injury, fire or other consequential damage due to operation of the Renesas
product.
5. This product is not designed to be radiation resistant.
6. No one is permitted to reproduce or duplicate, in any form, the whole or part of this document
without written approval from Renesas.
7. Contact Renesas’s sales office for any questions regarding this document or Renesas
semiconductor products.
Preface
Thank you for purchasing this user system interface cable (HS2276ECH61H) for the Renesas’s
original microcomputer H8S/2276R, H8S/2276 series.
The HS2276ECH61H is a user system interface cable that connects an H8S/2214 series E6000
emulator (HS2214EPI61H; hereinafter referred to as the emulator) through the expansion board to
the IC socket for a TFP-100B package for the H8S/2276R, H8S/2276 series MCU on the user
system.
Use an IC149-100-054-B51 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-100B
package IC socket on the user system.
Figure 1 shows the configuration of the HS2276ECH61H user system interface cable for the
TFP-100B package.
Figure 1 HS2276ECH61H User System Interface Cable
2
1
Table 1 lists the HS2276ECH61H components. Please make sure y ou have all of these component s
when unpacking.
Table 1 HS2276ECH61H Components
No. Component Quantity Remarks
1 Cable body 1 Flat cable
2 Cable head 1
3 IC socket 1 For the TFP-100B package
4 Socket cover 1 For installing a TFP-100B packaged MCU
5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers)
6 Screws (M2.6 x 6 mm) 4 For installing a TFP-100B packaged MCU (with
7 Documentation 1 User’s manual for HS2276ECH61H (this manual)
four flat washers)
Section 2 Connection Procedures
2.1 Connecting User System Interface Cable to Emulator Station
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are
correctly aligned.
2. The user system interface cable dedicated to the
emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface
cable, apply force only in the direction suitable for
connection or removal, while making sure not to bend or
twist the cable or connectors. Otherwise, the connectors
will be damaged. The user system interface cable must be
connected to an H8S/2214 series E6000 emulator through
the H8S/2276R, H8S/2276 series expansion board. Do not
connect the user system interface cable directly to the
E6000 emulator.