Renata SA ICP501421PS User Manual

Page 1
ICP501421PS
Specifications
Dimensions
Rechargeable Lithium Ion Polymer Battery Pack 3.7 V Safety Circuit
Renata Type IEC Designation Part Number Contact Method Safety Circuit
Nominal Voltage Nominal Capacity Minimum Capacity
ICP501421 ICP061423 100690 Wire AWG 30 Yes
3.7 V 115 mAh 108 mAh ( 0.2C cut off 3.0 V at
20°C )
Internal Impedance
Thickness ( t ) Lenghth ( l Width ( w ) Weight
Charging Characteristic
Voltage Current Normal Max. Charging Current Temperature at Charging
Discharge Characteristic
Cut off Voltage Max Discharge Current
Temperature During Discharge
Cycle Life at Room Temperature
Storage Temperature
Information and contents in this data sheet are for reference purpose only. They do not constitute any warranty or representation and are subject to change without notice. For most current information and further details, please contact your Renata representative.
< 360 m / 50% SOC
Max 5.2 mm Max 22.5 mm Max 14.1 mm ~ 3.1 g
CC/CV – Constant Current / Constant Voltage
4.2 V CV
0.5 C CC – 57.5 mA
1.0 C CC – 115 mA 0 °C …. 45 °C
3.0 V
2.0 C – 230 mA ( for non continues discharge )
1.0 C – 115 mA ( for continues discharge )
-20 °C … 60 °C
> 80% of minimum capacity after 500 cycles ( 0.5 C charge, 0.5 C discharge )
-20 °C … 45 °C ( 0 °C … 30 °C recommended in case of storage for
more than 3 months)
Renata SA Tel. +41 (0)61 975 75 75 sales@renata.com CH-4452 Itingen/Switzerland Fax. +41 (0)61 975 75 95 www.renata.com
Rev. Li Ion ICP501421 - 11.09
Loading...