Remote Automation Solutions Guide: Alarm OPC and Event Server Reference Guide-OpenEnterprise v2.83 Manuals & Guides

Reference Guide
D301516X412 April 2012
Remote Automation Solutions
Website: www.EmersonProcess.com/Remote
Reference Guide
r
D301516X412 April 2012
OPC Alarm and Event Serve
Contents
1 OPC Alarm and Event Server .................................................................................................1
2 Main Dialog...............................................................................................................................1
2.1 File_Menu ...........................................................................................................................2
2.2 Edit Menu............................................................................................................................2
2.3 View Menu ..........................................................................................................................3
2.4 Help Menu...........................................................................................................................3
2.5 Properties Command Button...............................................................................................3
2.6 About Command Button......................................................................................................3
2.7 Database Connections........................................................................................................3
2.8 Start Time............................................................................................................................3
2.9 Last Update.........................................................................................................................3
2.10 Server Status...................................................................................................................4
2.11 Licensing Status ..............................................................................................................4
2.12 Number of Subscriptions .................................................................................................4
2.13 Client List.........................................................................................................................4
2.14 Details Button ..................................................................................................................4
3 General Property Tab ..............................................................................................................4
3.1 Show System Tray Icon......................................................................................................5
3.2 Show Window .....................................................................................................................5
3.3 Minimize Window ................................................................................................................5
3.4 Hide on Minimize.................................................................................................................5
3.5 Severity Weighting - Non Network3000 Alarms..................................................................5
3.6 Severity Weighting - Network3000 Alarm Priorities............................................................6
3.7 Severity Weighting Continued.............................................................................................6
3.8 NW3000 Severity Mapping .................................................................................................6
3.9 OK Button............................................................................................................................7
3.10 Cancel Button..................................................................................................................7
3.11 Help Button......................................................................................................................7
4 Databases Tab..........................................................................................................................7
4.1 Pre-connect Databases.......................................................................................................7
4.2 Add Button ..........................................................................................................................8
4.3 Remove Button ...................................................................................................................8
4.4 OK Button............................................................................................................................8
4.5 Cancel Button......................................................................................................................8
4.6 Help Button .........................................................................................................................8
4.7 Add Database Dialog..........................................................................................................8
4.7.1 Database Field ............................................................................................................. 8
4.7.2 OK Button.....................................................................................................................8
4.7.3 Cancel Button...............................................................................................................9
4.7.4 Help Button...................................................................................................................9
5 Event Subscription Details Dialog.........................................................................................9
5.1 Client Handle.......................................................................................................................9
5.2 Active...................................................................................................................................9
- i -
Reference Guide
r
D301516X412 April 2012
Databases...........................................................................................................................9
5.3
5.4 Low Severity......................................................................................................................10
5.5 High Serverity....................................................................................................................10
5.6 NW3000 Alarm Severity Mapping.....................................................................................10
5.7 Refresh Rate.....................................................................................................................10
5.8 Max Rows .........................................................................................................................10
5.9 Event Types ......................................................................................................................10
5.9.1 The OPC Standard.....................................................................................................11
5.9.2 OpenEnterprise Implementation.................................................................................11
5.10 Event Categories...........................................................................................................11
5.10.1 OPC Standard.........................................................................................................11
5.10.2 OpenEnterprise Implementation.............................................................................11
5.11 Selected Attributes.........................................................................................................12
5.12 Level ..............................................................................................................................12
5.13 Discrete..........................................................................................................................12
5.14 Deviation........................................................................................................................12
5.15 OK Button ......................................................................................................................12
5.16 Help Button....................................................................................................................12
OPC Alarm and Event Serve
6 Index .......................................................................................................................................13
- ii -
Reference Guide
r
D301516X412 April 2012
OPC Alarm and Event Serve

1 OPC Alarm and Event Server

OPC (OLE for Process Control) is an industry wide standard, defining the coll ection and distribution of data from RTUs, PLCs or Controllers. The OPC standard contains rules relating to a number of data types: -
Realtime data
Historical data
Alarm and Event data
The OpenEnterprise OPC Alarm and Event Server will provide Alarm and Event data from Bristol RTUs to any Alarm and Event client implementing the OPC standard. You should refer to the client's documentation for instructions on how to set the client up to receive data from the OPC Alarm and Event Server.

2 Main Dialog

The OPC Alarm and Event Server's User Interface provides Server and Client information to the user, and also allows the user to configure various parameters, which define how the interface behaves.
- 1 -
Reference Guide
r
D301516X412 April 2012
OPC Alarm and Event Serve

2.1 File_Menu

The file menu provides the option to close the OPC Server's User Interface.

2.2 Edit Menu

The Edit menu provides access to the Property pages for the OPC Alarm and Event Server's User Interface. If this option is disabled, you can enable it by setting the following value data to 0 (zero) in the OpenEnterprise Settings Editor:-
- 2 -
Reference Guide
r
D301516X412 April 2012
Key: OpenEnterprise\Tasks\BristolOPCServer
Value: DISABLEPROPERTIES
OPC Alarm and Event Serve

2.3 View Menu

The View menu has two options, which allow you to show or hide the Toolbar and Status bar. A tick indicates that the item will be visible.

2.4 Help Menu

The Help menu has two options. The first option (OPC Alarm and Event Server Help) provides access to this Help file. The second option (About OPC Alarm and Event Server) opens an 'About' information dialog having two tabs. The first tab displays the OpenEnterprise version and build, and the second tab provides contact information.

2.5 Properties Command Button

This command button opens the OPC Alarm and Event Server's Property pages.

2.6 About Command Button

This opens an 'About' information dialog having two tabs. The first tab displays the OpenEnterprise version and build, and the second tab provides contact information.

2.7 Database Connections

This list displays the databases that the OPC Server has attempted to connect to. The list also provides information on connection status, connection time and the number of alarms currently available from those databases.

2.8 Start Time

This shows the time when the OPC Alarm and Event Server was started.

2.9 Last Update

Shows the last time that the OPC Alarm and Event Server reported alarms to any of the connected clients.