Read these operating instructions carefully
before commissioning / using the device!
These instructions are an integral part of the unit and must
always be kept in the vicinity of the installation location or
on the unit itself.
Subject to modifications; no liability accepted for errors or
misprints!
3
REMKO KPS 300
Safety notes
Carefully read the operating manual
before placing the unit in service for
the first time. It contains useful tips
and notes ! such as hazard warnings
to prevent injury and material damage.
Failure to follow the directions in this
manual can result in endangerment
to persons, the environment and the
equipment itself and will void any claims
for liability.
■ Keep this manual in the vicinity of
the units.
■ The units and components should
be set up and installed only by
qualified personnel.
■ The set-up, connection, and operation
of the unit and its components
must take place in accordance with
the operating conditions stipulated
in this manual and comply with all
applicable local regulations.
■ Modification of units and components
supplied by REMKO is not permitted
and can cause malfunctions.
■ Units and components may not be
operated in areas where there is an
increased risk of damage. Observe
the minimum clearances.
■ The electrical supply is to be adapted
to the requirements of the units.
■ The operational safety of units and
components is only assured if they are
fully assembled and used as intended.
Safety devices may not be modified
or bypassed.
■ Do not operate units or components
with obvious defects or signs of
damage.
■ The units and components must
be kept an adequate distance from
flammable, explosive, combustible,
abrasive and dirty areas or
atmospheres.
■ Installation, repair and maintenance
work may be carried out only
by authorised specialists. Visual
inspections and cleaning can be
performed by the operator as long
as power is disconnected from the
equipment.
■ To preclude any danger from the unit,
take appropriate hazard-prevention
measures when performing
installation, repair or maintenance
work or cleaning the units.
4
Environmental
protection and recycling
Intended
use
Disposing of packaging
All products are packed for transport
in environmentally friendly materials.
You can make a valuable contribution
to reducing waste and sustaining raw
materials by only disposing of packaging
at approved collection points.
Disposal of
components
The manufacturing process for the units
is subject to continuous quality control.
Only high-grade materials are processed,
the majority of which are recyclable. You
can also contribute to environmental
protection by only disposing
of components in accordance with local
regulations and in an environmentally
safe manner, e.g. through authorised
disposal and recycling specialists or at
collection
points.
The storage tanks are employed
for the storage of hot water in all types
of warm water central heating systems
(solid fuel/oil-fired boilers, heat pumps,
solar energy systems, gas/electric
instantaneous water heaters) within
enclosed spaces and for the storage of
cold water for cooling processes or heat
recovery purposes.
Any different or additional use shall
be classed as non-intended use.
The manufacturer/supplier assumes no
liability for damages arising from such
use. The user bears the sole risk in such
cases.
Intended use also includes working
in accordance with the operating
manual and installation instructions
and complying with the maintenance
requirements.
Operation
Manual operation is not necessary.
Warranty
The warranty conditions are listed in the
"General terms and conditions".
Please contact your contractual partner
in he first instance.
5
REMKO KPS 300
Description
The storage tanks are employed for
the storage of hot water in all types of
warm water central heating systems
(solid fuel/oil-fired boilers, heat pumps,
solar energy systems, gas/electric
instantaneous water heaters) within
enclosed spaces and for the storage of
cold water for cooling processes or heat
recovery purposes.
The tank volume can be adapted to
your particular needs by connecting
several storage tanks to form batteries.
The storage tanks may be used
universally, either as parallel storage
(hydraulic switch) or series storage.
The insulation of the storage tank
is comprised of 50 mm directly
applied, CFC-free, fine-pore PU foam.
The external cladding applied at the
factory is comprised of a powder-coated
steel sheet cladding in the colour:
silvery-grey; the insulation of the KPS
300 is water vapour diffusion-tight.
All storage tanks are manufactured from
quality steel in accordance with DIN EN
10025/10111. An electric booster heater
(immersion heater) can be fitted into
each storage tank in a 6/4" socket.
For retrofitting a fin-tube heat
exchanger, a D180 (f=180mm) blank
flange cover is included.
The storage tanks have 4 connection
ports 5/4"AG. A sensor channel enables
variable positioning of a temperature
sensor.
Decommissioning
Temporary shutdown
1. Disconnect the electrical connection
at all poles.
2. Drain the tank in areas where it is at
risk from frost and before the onset of winter.
3. Then also drain all cold water pipes
or hot water carrying lines leading
to the heating elements and to the heater/cooler as well as
all water-carrying fittings and lines
(including heating circuit = register)
back as far as the frost-proof section of the domestic water system
(domestic water connection).
Permanent decommissioning
Ensure that equipment and components
are disposed of in accordance with local
regulations, e.g. through authorised
disposal and recycling specialists or at
collection points.
REMKO GmbH & Co. KG or your
contractual partner will be pleased to
provide a list of certified firms near you.
! ATTENTION
When emptying the tank, hot
water may escape!
! ATTENTION
When placing the tank back into
service, ensure that it is filled with
water and that water which is free
of bubbles is escaping from the
valves!
6
Care and maintenance
Care
■
Only clean the units with a
damp cloth
(adding, for instance, a liquid
household cleaner.
Do not use any harsh, scouring
or solvent-based cleaners.)
Maintenance
■
We recommend concluding a
maintenance contract with a
specialist firm, which includes annual
maintenance services.
NOTE
This ensures the operational
reliability of your equipment!
■
Regularly check the function of
the safety valve.
The expansion water amount at
maximum heat (approx. 80°C) represents
approx. 3.5% of the tank capacity.
When the safety valve test knob is
lifted or turned to the “Test” position,
the water must flow unhindered out of
the safety valve body into the drainage
funnel.
! ATTENTION
This can cause the cold water
supply and parts of the storage tank
connection fitting to become hot!
If the tank is not heated or when warm
water is removed, no water should be
dripping from the safety valve. If this
does occur, either the pressure in the
water pipe is greater than the permitted
value, or the safety valve is defective. If
the pressure in the water pipe is higher
than permitted, a pressure relief valve
must be used.
Installation instructions
for qualified personnel
General instructions prior to installation
■
Ensure that the area in which
the unit is to be operated is free
of frost and easily accessible for
required maintenance, repairs and
even for the possible replacement
of the unit (e.g. avoid overly narrow
thoroughfares and doorways).
■
When installing the storage tank in
unusual locations, such as in lofts,
residential units with floors that
are sensitive to water, storerooms,
etc. take account of the possibility
of leaking water, and ensure that a
facility is in place to catch the water,
including appropriate drainage
methods.
■
The unit may only be positioned and
operated on level surfaces.
7
REMKO KPS 300
■
Ensure that the area in which
the unit is to be operated is free
of frost and easily accessible for
required maintenance, repairs and
even for the possible replacement
of the unit (e.g. avoid overly narrow
thoroughfares and doorways).
■
When installing the storage tank
in unusual locations, such as in lofts,
residential units with floors that
are sensitive to water, storerooms,
etc. take account of the possibility
of leaking water, and ensure that a
facility is in place to catch the water,
including appropriate drainage
methods.
■
The unit may only be positioned and
operated on level surfaces.
■
When planning the unit's installation
surface and selecting the installation
location, note the total weight of the
storage tank, including the weight
of the water (the nominal capacity),
in order to ensure that the statics
of the load-bearing surface are not
exceeded.
! ATTENTION
The storage tank is not suitable for
preparing drinking water!
Central heating connection
Before being placed into service, the
heat distribution must be rinsed out in
order to remove any soiling (e.g. scale)
from the heating circuit.
Installation
■
■
■
Check the contents of the packaging
for completeness and check the
unit for visible transport damage.
Immediately notify your contractual
partner of any deficiencies.
The unit must be assembled on site.
For all connection ports, ensure that
the thread is fully engaged.
■
Ensure proper clearance from firing
systems.
■
Make sure that units with enclosures,
which are installed in small, tight
spaces or in suspended ceilings
have the connection block (water
and electric connections and heater
installation) still freely accessible and
that there us no buildup of heat.
■
Leave at least 500mm of space free
for the removal of the cleaning/
heating flange.
8
Installation
General Information
■
Do not continually top up the water
level in the storage tank. This will
prevent corrosion damage to the
tank.
■
If aggressive water is an issue, please
note that special models of the tank
can be tested (address all queries to
your contractual partner)
■
In hard water areas, connect
Electric booster heater
a standard descaling device upstream
■
of the tank.
Use the 6/4" socket to install an
electric booster heater (immersion
NOTE
heater)
Installation may only be performed
■
by authorised specialists.
Preparation of the hot water
must be in compliance with the
Please note that the electric booster
heater must not be used as a
permanent heating system.
applicable standards.
NOTE
Installation may only be performed
by authorised specialists.
Assignment of the connection ports
Variant 1: Heat pump located to the
right of the storage tank
Heating circuit supply
5/4“ AG
Immersion tube
for temperature sensor
Heating circuit return line and
emptying through customer-
provided T-section 5/4" AG
Cleaning flange or
opening for fin-tube
heat exchanger D180
(special accessory)
Top 1" AG connection,
for: venting, safety group
Heat pump supply line
5/4“ AG
Optional: Electric booster
heating (immersion
heating) 6/4" IG
Heat pump return line
5/4“ AG
9
REMKO KPS 300
Variant 2: Heat pump located to the
left of the storage tank
Heat pump supply line
5/4“ AG
Immersion tube
for temperature sensor
Heat pump return line
5/4“ AG
Cleaning flange or
opening for fin-tube
heat exchanger D180
(special accessory)
Commissioning
Top 1" AG connection,
for: venting, safety group
Heating circuit supply
5/4“ AG
Optional: Electric booster
heating (immersion
heating) 6/4" IG
Heating circuit return line and
emptying through customerprovided T-section 5/4" AG
NOTE
Commissioning should only be
performed and documented by
specially trained personnel.
1.
Check all connections, even those
which were sealed at the factory
(flange), for leak-tightness.
2 Then check all pipes for any leaks
and, if necessary, fix them.
10
3.Test the safety module and valves
for function.
4. During the heating process, all
expansion water generated in
the tank must be captured by an
appropriate expansion vessel.
Flange installation port
Depending on the design of your
system, fin-tube heat exchangers may
Fitting the flange installation port
Supporting disc
Flange plate
be attached to the boiler flanges.
■
First tighten the nuts by hand.
■
Then tighten the nuts, in the
sequence specified below, to a
torque of 20 Nm to max. 25 Nm.
Unit dimensions and technical data
1514
1420,5
246
983
924,5
Seal
1689
1797
Flange ring
305
Weight
[kg]
Energy consumption in standby
(emission value)
according to DIN 44532
[kWh/d]
Unit type
Nominal
capacity
[l]
ø600
Operating
temperature
min/max
[°C]
180
Operat-
ing pres-
sure
[bar]
90°
Tilt
height
[mm]
KPS 3003000/95317401182,2
We reserve the right to modify the dimensions and constructional design as part of the ongoing
technical development process.
11
REMKO INTERNATIONAL
... and also right in your neighbourhood!
Benefit from our experience and advice
REMKO GmbH & Co. KG
Air conditioning and heating technology
Im Seelenkamp 12 D-32791 Lage
Postfach 1827 D-32777 Lage
Telephone +49 5232 606-0
Fax +49 5232 606-2 60
e-mail info@remko.de
Website www.remko.de