1 SAFETY 3
2 PROBLEMS WITH BOILER AND/OR CENTRAL HEATING SYSTEM 4
3 CHANGING BOILER SETTINGS 5
4 DISABLING THE BOILER 7
5 ENABLING THE BOILER 8
6 WARRANTY & SERVICE 9
Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hotwater Industry Council who manage and promote the Scheme.
Visit www.centralheating.co.uk for more information.
Contents
3
Remeha Avanta
62999-130711
1. Safety
1 SAFETY
Can you smell gas? What to do:
• Do not smoke and do not create any flame or sparks.
• Do not use any electric switches.
• Turn off the main gas stop cock.
• Open windows and doors.
• Warn those present and leave the building together.
• Call your gas suppliers / installer once you are outside the building, TRANSCO tel. 0800 111 999.
Can you smell smoke or flue gases? What to do:
• Switch off the boiler.
• Open windows and doors.
• Warn those present and leave the building together.
• Call your installer once you are outside the building.
Installation location for the boiler!
• Do not store or use any flammable materials, aggressive substance and/or aerosols near the boiler.
• The installation area must be frost-free.
• The switched spur unit for the boiler must always be accessible.
Water and pipe temperatures!
• The factory setting for the tap water temperature is 55°C; this temperature can be set to 65°C.
• The maximum water temperature in the Avanta can reach 90°C. This means that pipes and/or radiators can reach this temperature.
• If the boiler is running, the flue duct can reach a high temperature.
4
Remeha Avanta
62999-130711
2. Problems with boiler and/or centrale heating system
2 PROBLEMS WITH BOILER AND/OR CENTRAL HEATING SYSTEM
Error codes – errors which can be resolved by the user
R
R
R
R
R
R
e1
e4
Press R-key Wait for recovery;
display shows 0, boiler functions properly.
Check gas valve, gas valve must be open, if necessary open valve.
Press R-key Wait for recovery;
display shows 0, boiler functions properly.
Display shows e4 again: note down the error code and boiler type and call your installer.
Or
Or
e2
LT.NL.W6H.000.115 + LT.NL.W6H.000.118 + LT.NL.W6H.000.121 + LT.NL.W6H.000.122
59970.LT.GB.W7H.040
Error codes – errors which have to be remedied by the installer
If the display indicates a different error code from that described above, note down the error code and boiler type and call your installer. Contact your installer also in the event of a water leak.
Display shows e1, e2, e7 or e10 again; note down the error code and boiler type and call your installer
e7
e10