REMEHA 220 SHL User Manual

EN
Solar domestic hot water calorifier
220 SHL
User Guide
300028214-001-03
Contents
1.1 Safety instructions ...............................................4
1.2 Recommendations ................................................4
2 About this manual ......................................................................................6
2.1 Symbols used .......................................................6
2.1.1 Symbols used in the manual ...................................6
2.1.2 Symbols used on the equipment .............................6
2.2 Abbreviations ........................................................6
2.3 Liabilities ...............................................................7
2.3.1 Manufacturer’s liability .............................................7
2.3.2 Installer’s liability .....................................................7
2.3.3 User’s liability ..........................................................7
3 Technical specifications ............................................................................8
3.1 Homologations ......................................................8
3.1.1 Certifications ...........................................................8
3.2 Technical specifications ......................................8
3.2.1 Characteristics of the DHW calorifier ......................8
1
06/01/2015 - 300028214-001-03
4 Description ................................................................................................10
4.1 Composition of the NF CESI solar systems
packages (for France only) ................................10
4.2 Main parts ............................................................14
5 Operating the appliance ..........................................................................16
5.1 Commissioning procedure ................................16
5.2 Antifreeze protection ..........................................16
5.3 Shutting down the solar control system ..........16
6 Checking and maintenance .....................................................................18
6.1 General instructions ...........................................18
6.2 Safety valve or safety unit (Domestic hot water
circuit) ..................................................................18
6.3 Cleaning the casing material .............................18
6.4 Impressed current anode ...................................18
6.5 Inspection and maintenance of the solar
circuit ...................................................................19
6.6 solar regulator .....................................................19
6.7 Maintenance of the thermostatic mixing
valve .....................................................................19
7 Warranty ....................................................................................................20
7.1 General ................................................................20
7.2 Warranty terms ...................................................20
Contents
2
06/01/2015 - 300028214-001-03
3
06/01/2015 - 300028214-001-03
1 Safety instructions and
recommendations
1.1 Safety instructions
CAUTION
Before any work, switch off the mains supply to the appliance.
CAUTION
In order to limit the risk of being scalded, the installation of a thermostatic mixing valve on the domestic hot water flow piping is compulsory.
DANGER
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
1.2 Recommendations
Have the installation regularly serviced to guarantee that it operates correctly over time.
CAUTION
Never cut the power to the solar control system, even during extended absences. The control system protects the installation against overheating in summer when it is running.
During extended absences, we recommend lowering the set point temperature in the solar DHW calorifier to 45°C. When the user is present, the set point must be set to 60°C.
220 SHL
1. Safety instructions and recommendations
06/01/2015 - 300028214-001-03
4
CAUTION
Never drain the installation. Do not replace or add water or solar fluid to the installation. These actions must be carried out by a qualified technician.
CAUTION
Do not modify the control system parameters unless fully conversant with them.
1. Safety instructions and recommendations 220 SHL
5
06/01/2015 - 300028214-001-03
2 About this manual
2.1 Symbols used
2.1.1. Symbols used in the manual
In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, highlight hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼Signals a referral to other instructions or other pages in the instructions.
2.1.2. Symbols used on the equipment
Before installing and commissioning the device, read carefully the instruction manuals provided.
Dispose of the used products in an appropriate recovery and recycling structure.
2.2 Abbreviations
4 CFC: Chlorofluorocarbon
4 DHW: Domestic hot water
4 ICA: Impressed current anode
220 SHL
2. About this manual
06/01/2015 - 300028214-001-03
6
2.3 Liabilities
2.3.1. Manufacturer’s liability
Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore
delivered with [ marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Failure to abide by the instructions on using the appliance.
4 Faulty or insufficient maintenance of the appliance.
4 Failure to abide by the instructions on installing the appliance.
2.3.2. Installer’s liability
The installer is responsible for the installation and commissioning of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Carry out installation in compliance with the prevailing legislation
and standards.
4 Perform the initial start up and carry out any checks necessary.
4 Explain the installation to the user.
4 If a maintenance is necessary, warn the user of the obligation to
check the appliance and maintain it in good working order.
4 Give all the instruction manuals to the user.
2.3.3. User’s liability
To guarantee optimum operation of the appliance, the user must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Call on qualified professionals to carry out installation and initial
start up.
4 Get your installer to explain your installation to you.
4 Ensure the Appliance is serviced in accordance with the
manufacturer’s instructions by a suitable qualified person.
4 Keep the instruction manuals in good condition close to the
appliance.
2. About this manual
220 SHL
7
06/01/2015 - 300028214-001-03
3 Technical specifications
3.1 Homologations
3.1.1. Certifications
n
NF certification
This product complies to the requirements to the european directives and following standards:
4 2006/95/EC Low Voltage Directive.
Reference Standard: EN 60.335.1.
4 2004/108/EC Electromagnetic Compatibility Directive.
Reference Standards: EN 50.081.1, EN 50.082.1, EN 55.014
3.2 Technical specifications
3.2.1. Characteristics of the DHW calorifier
DHW tank 220SHL
Primary circuit (Heating water)
Maximum operating temperature °C 95
Maximum operating pressure bar (MPa) 3 (0.3)
Primary circuit (Solar circuit fluid)
Maximum operating temperature °C 135
Maximum operating pressure bar (MPa) 6 (0.6)
Exchanger capacity l 8.4
Exchange surface
m
2
1.25
Secondary circuit (domestic water)
Maximum operating temperature °C 95
Maximum operating pressure bar (MPa) 10 (1.0)
Water content l 220
Top up volume l 85
Solar volume l 135
Weight
Shipping weight (Foam coated domestic hot water tank) kg 109
220 SHL 3. Technical specifications
06/01/2015 - 300028214-001-03
8
Performances related to the boiler type
Gas fired floor-standing condensing boiler
(1)
10/15 kW 15 kW 25 kW 35 kW
Power exchanged kW 15 15 28 32
Flow per hour (∆T = 35°C)
(2)
l/h 370 370 690 790
Specific flow (∆T = 30°C)
(3)
l/min 20 20 24 26
Draw-off capacity
(3)
l/10 mm 200 200 240 260
Qp: Primary flow rate
m3/h
0.45 0.45 0.80 1.00
(1) Depending on the country in which the boiler is installed (2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C (3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C
Performances related to the boiler type
Floor-standing condensing oil boiler
(1)
18 kW 24 kW 30 kW
Power exchanged kW 18 24 30
Flow per hour (∆T = 35°C)
(2)
l/h 440 590 740
Specific flow (∆T = 30°C)
(3)
l/min 21 24 25
Draw-off capacity
(3)
l/10 mm 210 240 260
Qp: Primary flow rate
m3/h
0.75 0.75 0.85
(1) Depending on the country in which the boiler is installed (2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C (3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C
3. Technical specifications 220 SHL
9
06/01/2015 - 300028214-001-03
4 Description
4.1 Composition of the NF CESI solar systems packages (for France only)
Check the composition of the NF CESI solar system package against the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.
A system is complete and functional according to the NF CESI mark if all system references appear on the invoice. The system is composed of the following elements:
4 A collector field with 1 or 2 solar collectors.
4 A boiler system (Modulens or OEnoviaGas Confort / OEnoviaFioul
Confort) + solar domestic hot water tank to which a solar station is mounted in the factory, which includes a heating pump, an expansion vessel and a Diemasol A / Oetrosol A control system.
4 The solar fluid that protects the installation from frost and
corrosion.
CESI System
Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
Boiler + DHW tank package package / Reference package /
Reference
DIETRISOL Modulens 220D-2
(1 collector)
On roof
ER430-100019693 ER431-100019694
220 SHL AGC 15 VH / V220SHL AGC 15 VH / B220SHL AGC 15 VV / V220SHL AGC 15 VV / B220SHL AGC 25 VH / V220SHL AGC 25 VH / B220SHL AGC 25 VV / V220SHL AGC 25 VV / B220SHL AGC 35 VH / V220SHL AGC 35 VH / B220SHL AGC 35 VV / V220SHL AGC 35 VV / B220SHL AGC 10/15 VH / V220SHL AGC 10/15 VV / V220SHL AGC 10/15 VH / B220SHL AGC 10/15 VV / B220SHL AFC 18/ B220SHL AFC 24/ B220SHL AFC 30/ B220SHL AFC 18 FF HOR/ B220SHL AFC 18 FF VER/ B220SHL AFC 24 FF HOR/ B220SHL AFC 24 FF VER/ B220SHL AFC 30 FF HOR/ B220SHL AFC 30 FF VER/ B220SHL
ER220-100016425 100018125 100018127 100018126 100018128 100018129 100018131 100018130 100018132 100018133 100018135 100018134 100018136 100019292 100019293 100019349 100019350 100017846 100017847 100017848 100017866 100017867 100017868 100017869 100017870 100017871
ER316 100017611
Roof-integral Installation (> 22°)
ER620-7615855
Roof-integral Installation (17°)
ER624-7615864
220 SHL 4. Description
06/01/2015 - 300028214-001-03
10
CESI System Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
Boiler + DHW tank package package / Reference package /
Reference
DIETRISOL Modulens 220-3
(1 collector ­Vertical mounting)
On roof
ER240-100016502 ER245-100016506 ER247-100016508 ER260-100016513
220 SHL AGC 15 VH / V220SHL AGC 15 VH / B220SHL AGC 15 VV / V220SHL AGC 15 VV / B220SHL AGC 25 VH / V220SHL AGC 25 VH / B220SHL AGC 25 VV / V220SHL AGC 25 VV / B220SHL AGC 35 VH / V220SHL AGC 35 VH / B220SHL AGC 35 VV / V220SHL AGC 35 VV / B220SHL AGC 10/15 VH / V220SHL AGC 10/15 VV / V220SHL AGC 10/15 VH / B220SHL AGC 10/15 VV / B220SHL AFC 18/ B220SHL AFC 24/ B220SHL AFC 30/ B220SHL AFC 18 FF HOR/ B220SHL AFC 18 FF VER/ B220SHL AFC 24 FF HOR/ B220SHL AFC 24 FF VER/ B220SHL AFC 30 FF HOR/ B220SHL AFC 30 FF VER/ B220SHL
ER220-100016425 100018125 100018127 100018126 100018128 100018129 100018131 100018130 100018132 100018133 100018135 100018134 100018136 100019292 100019293 100019349 100019350 100017846 100017847 100017848 100017866 100017867 100017868 100017869 100017870 100017871
ER316 100017611
Roof-integral Installation (> 22°)
ER240-100016502 ER245-100016506 ER247-100016508 ER635-7212869
Roof-integral Installation (17°)
ER240-100016502 ER245-100016506 ER247-100016508 ER640-7212872
DIETRISOL Modulens 220-3
(1 collector ­Horizontal mounting)
On roof
ER241-100016503 ER245-100016506 ER247-100016508 ER261-100016514
Roof-integral Installation (> 22°)
ER241-100016503 ER245-100016506 ER247-100016508 ER637-7212866
Roof-integral Installation (17°)
ER241-100016503 ER245-100016506 ER247-100016508 ER643-7212873
DIETRISOL Modulens 220D-4
(2 collectors)
On roof
ER432-100019695 ER433-100019696 ER434-100019697
220 SHL AGC 15 VH / V220SHL AGC 15 VH / B220SHL AGC 15 VV / V220SHL AGC 15 VV / B220SHL AGC 25 VH / V220SHL AGC 25 VH / B220SHL AGC 25 VV / V220SHL AGC 25 VV / B220SHL AGC 35 VH / V220SHL AGC 35 VH / B220SHL AGC 35 VV / V220SHL AGC 35 VV / B220SHL AGC 10/15 VH / V220SHL AGC 10/15 VV / V220SHL AGC 10/15 VH / B220SHL AGC 10/15 VV / B220SHL AFC 18/ B220SHL AFC 24/ B220SHL AFC 30/ B220SHL AFC 18 FF HOR/ B220SHL AFC 18 FF VER/ B220SHL AFC 24 FF HOR/ B220SHL AFC 24 FF VER/ B220SHL AFC 30 FF HOR/ B220SHL AFC 30 FF VER/ B220SHL
ER220-100016425 100018125 100018127 100018126 100018128 100018129 100018131 100018130 100018132 100018133 100018135 100018134 100018136 100019292 100019293 100019349 100019350 100017846 100017847 100017848 100017866 100017867 100017868 100017869 100017870 100017871
ER316 100017611
Roof-integral Installation (> 22°)
ER621-7615864
Roof-integral Installation (17°)
ER625-7615866
4. Description 220 SHL
11
06/01/2015 - 300028214-001-03
CESI System Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
Boiler + DHW tank package package / Reference package /
Reference
DIETRISOL Modulens 220-5
(2 collectors ­Vertical mounting)
On roof
ER240-100016502 ER245-100016506 ER247-100016508 ER260-100016513
220 SHL AGC 15 VH / V220SHL AGC 15 VH / B220SHL AGC 15 VV / V220SHL AGC 15 VV / B220SHL AGC 25 VH / V220SHL AGC 25 VH / B220SHL AGC 25 VV / V220SHL AGC 25 VV / B220SHL AGC 35 VH / V220SHL AGC 35 VH / B220SHL AGC 35 VV / V220SHL AGC 35 VV / B220SHL AGC 10/15 VH / V220SHL AGC 10/15 VV / V220SHL AGC 10/15 VH / B220SHL AGC 10/15 VV / B220SHL AFC 18/ B220SHL AFC 24/ B220SHL AFC 30/ B220SHL AFC 18 FF HOR/ B220SHL AFC 18 FF VER/ B220SHL AFC 24 FF HOR/ B220SHL AFC 24 FF VER/ B220SHL AFC 30 FF HOR/ B220SHL AFC 30 FF VER/ B220SHL
ER220-100016425 100018125 100018127 100018126 100018128 100018129 100018131 100018130 100018132 100018133 100018135 100018134 100018136 100019292 100019293 100019349 100019350 100017846 100017847 100017848 100017866 100017867 100017868 100017869 100017870 100017871
ER316 100017611
Roof-integral Installation (> 22°)
ER240-100016502 ER245-100016506 ER247-100016508 ER634-7212864 ER636-7212867
Roof-integral Installation (17°)
ER240-100016502 ER245-100016506 ER247-100016508 ER640-7212872 ER642-7212875
DIETRISOL Modulens 220-5
(2 collectors ­Horizontal mounting)
On roof
ER241-100016503 ER245-100016506 ER247-100016508 ER261-100016514
Roof-integral Installation (> 22°)
ER241-100016503 ER245-100016506 ER247-100016508 ER637-7212866 ER639-7212868
Roof-integral Installation (17°)
ER241-100016503 ER245-100016506 ER247-100016508 ER643-7212873 ER645-7212877
PERFECTSUN Oenovia 220D-2
(1 collector)
On roof
ER430-100019693 ER431-100019694
V 220 SHL GVCR 15 HOR/220SHL GCCR 15 HOR/220SHL GVCR 25 HOR/220SHL GCCR 25 HOR/220SHL GVCR 35 HOR/220SHL GCCR 35 HOR/220SHL GVCR 15 VER/220SHL GCCR 15 VER/220SHL GVCR 25 VER/220SHL GCCR 25 VER/220SHL GVCR 35 VER/220SHL GCCR 35 VER/220SHL OCCR 18/220SHL OCCR 24/220SHL OCCR 30/220SHL OCCR 18 HOR /220SHL OCCR 18 VER /220SHL OCCR 24 HOR /220SHL OCCR 24 VER /220SHL OCCR 30 HOR /220SHL OCCR 30 VER /220SHL
ER220-100016425 100018232 100018234 100018236 100018238 100018240 100018242 100018232 100018234 100018236 100018238 100018240 100018242 100019381 100019382 100019383 100019402 100019403 100019404 100019405 100019406 100019407
ER316 100017611
Roof-integral Installation (> 22°)
ER620-7615855
Roof-integral Installation (17°)
ER624-7615864
220 SHL 4. Description
06/01/2015 - 300028214-001-03
12
CESI System Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
Boiler + DHW tank package package / Reference package /
Reference
PERFECTSUN Oenovia 220-3
(1 collector ­Horizontal mounting)
On roof
ER240-100016502 ER245-100016506 ER247-100016508 ER260-100016513
V 220 SHL GVCR 15 HOR/220SHL GCCR 15 HOR/220SHL GVCR 25 HOR/220SHL GCCR 25 HOR/220SHL GVCR 35 HOR/220SHL GCCR 35 HOR/220SHL GVCR 15 VER/220SHL GCCR 15 VER/220SHL GVCR 25 VER/220SHL GCCR 25 VER/220SHL GVCR 35 VER/220SHL GCCR 35 VER/220SHL OCCR 18/220SHL OCCR 24/220SHL OCCR 30/220SHL OCCR 18 HOR /220SHL OCCR 18 VER /220SHL OCCR 24 HOR /220SHL OCCR 24 VER /220SHL OCCR 30 HOR /220SHL OCCR 30 VER /220SHL
ER220-100016425 100018232 100018234 100018236 100018238 100018240 100018242 100018232 100018234 100018236 100018238 100018240 100018242 100019381 100019382 100019383 100019402 100019403 100019404 100019405 100019406 100019407
ER316 100017611
Roof-integral Installation (> 22°)
ER240-100016502 ER245-100016506 ER247-100016508 ER634-7212864
Roof-integral Installation (17°)
ER240-100016502 ER245-100016506 ER247-100016508 ER640-7212872
PERFECTSUN Oenovia 220-3
(1 collector ­Horizontal mounting)
On roof
ER241-100016503 ER245-100016506 ER247-100016508 ER261-100016514
Roof-integral Installation (> 22°)
ER241-100016503 ER245-100016506 ER247-100016508 ER637-7212866
Roof-integral Installation (17°)
ER241-100016503 ER245-100016506 ER247-100016508 ER644-7212880
PERFECTSUN Oenovia 220D-4
(2 collectors)
On roof
ER432-100019695 ER433-100019696 ER434-100019697
V 220 SHL GVCR 15 HOR/220SHL GCCR 15 HOR/220SHL GVCR 25 HOR/220SHL GCCR 25 HOR/220SHL GVCR 35 HOR/220SHL GCCR 35 HOR/220SHL GVCR 15 VER/220SHL GCCR 15 VER/220SHL GVCR 25 VER/220SHL GCCR 25 VER/220SHL GVCR 35 VER/220SHL GCCR 35 VER/220SHL OCCR 18/220SHL OCCR 24/220SHL OCCR 30/220SHL OCCR 18 HOR /220SHL OCCR 18 VER /220SHL OCCR 24 HOR /220SHL OCCR 24 VER /220SHL OCCR 30 HOR /220SHL OCCR 30 VER /220SHL
ER220-100016425 100018232 100018234 100018236 100018238 100018240 100018242 100018232 100018234 100018236 100018238 100018240 100018242 100019381 100019382 100019383 100019402 100019403 100019404 100019405 100019406 100019407
ER316 100017611
Roof-integral Installation (> 22°)
ER621-7615864
Roof-integral Installation (17°)
ER625-7615866
4. Description 220 SHL
13
06/01/2015 - 300028214-001-03
CESI System Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
Boiler + DHW tank package package / Reference package /
Reference
PERFECTSUN Oenovia 220-5
(2 collectors ­Horizontal mounting)
On roof
ER240-100016502 ER245-100016506 ER247-100016508 ER260-100016513
V 220 SHL GVCR 15 HOR/220SHL GCCR 15 HOR/220SHL GVCR 25 HOR/220SHL GCCR 25 HOR/220SHL GVCR 35 HOR/220SHL GCCR 35 HOR/220SHL GVCR 15 VER/220SHL GCCR 15 VER/220SHL GVCR 25 VER/220SHL GCCR 25 VER/220SHL GVCR 35 VER/220SHL GCCR 35 VER/220SHL OCCR 18/220SHL OCCR 24/220SHL OCCR 30/220SHL OCCR 18 HOR /220SHL OCCR 18 VER /220SHL OCCR 24 HOR /220SHL OCCR 24 VER /220SHL OCCR 30 HOR /220SHL OCCR 30 VER /220SHL
ER220-100016425 100018232 100018234 100018236 100018238 100018240 100018242 100018232 100018234 100018236 100018238 100018240 100018242 100019381 100019382 100019383 100019402 100019403 100019404 100019405 100019406 100019407
ER316 100017611
Roof-integral Installation (> 22°)
ER240-100016502 ER245-100016506 ER247-100016508 ER634-7212864 ER636-7212867
Roof-integral Installation (17°)
ER240-100016502 ER245-100016506 ER247-100016508 ER640-7212872 ER642-7212875
PERFECTSUN Oenovia 220-5
(2 collectors ­Horizontal mounting)
On roof
ER241-100016503 ER245-100016506 ER247-100016508 ER261-100016514
Roof-integral Installation (> 22°)
ER241-100016503 ER245-100016506 ER247-100016508 ER637-7212866 ER639-7212868
Roof-integral Installation (17°)
ER241-100016503 ER245-100016506 ER247-100016508 ER643-7212873 ER645-7212877
4.2 Main parts
1
Solar expansion vessel
2
Thermostatic mixing valve for domestic hot water
3
Domestic hot water sensor
4
Solar regulator
5
Safety valve
6
Needle pressure gauge
7
Antithermosiphon valve operated by the spherical plug valve
8
Solar circuit circulating pump
9
Glycol reservoir
10
Primary solar circuit filling and draining device
11
Primary solar coil sensor
12
Manual bleed degasser
13
Primary solar coil
14
Titan Active System anode
15
Plate exchanger on the primary boiler circuit
16
Domestic hot water circulating pump
L000225-B
1
2
14
16
3
4 5 6 7
8
9
11
12
13
15
10
220 SHL 4. Description
06/01/2015 - 300028214-001-03
14
17
Drain cock
4. Description 220 SHL
15
06/01/2015 - 300028214-001-03
5 Operating the appliance
5.1 Commissioning procedure
CAUTION
Initial commissioning must be done by a qualified professional.
CAUTION
During the heating process, a certain amount of water may flow through the valve or safety unit, this is caused by water expansion. This phenomenon is completely normal and must in no event be hindered.
Once the DHW tank has been connected to the mains, the unit is managed from the boiler control panel. When in use, no direct action is needed on the DHW tank.
5.2 Antifreeze protection
WARNING
Do not switch off the mains supply.
4 Antifreeze protection is guaranteed.
4 Protection of the tank against corrosion.
5.3 Shutting down the solar control system
CAUTION
Do not shut down power to the control system or drain the heat-exchanging fluid.
M003223-A
220 SHL 5. Operating the appliance
06/01/2015 - 300028214-001-03
16
The system is designed in such a way that no special precautions are necessary during long periods of absence in summer. The solar control system protects the installation from overheating.
5. Operating the appliance 220 SHL
17
06/01/2015 - 300028214-001-03
6 Checking and maintenance
6.1 General instructions
CAUTION
4 Maintenance operations must be done by a qualified
engineer.
4 Only original spare parts must be used.
6.2 Safety valve or safety unit (Domestic hot water circuit)
The valve or safety assembly must be operated at least once a month in order to ensure that it is operating correctly and to prevent
possible overpressure which would damage the DHW tank.
WARNING
Failure to comply with this maintenance rule may cause deterioration of the DHW tank and the cancellation of the guarantee.
WARNING
Only operate the valve (red head) on the DHW circuit. Do not operate the valve (yellow head) on the solar circuit.
6.3 Cleaning the casing material
Clean the outside of appliances using a damp cloth and a mild detergent.
6.4 Impressed current anode
No maintenance operations are required on an impressed current anode.
CAUTION
The boiler control panel must be switched on to ensure that the impressed current anode operates.
Failure to abide by this maintenance rule may damage the domestic hot water calorifier and void its warranty.
There is a green LED on the impressed current anode board:
4 The LED flashes once when the board is powered up.
4 The LED is off during normal running.
220 SHL
6. Checking and maintenance
06/01/2015 - 300028214-001-03
18
If a fault is detected::
4 The LED flashes. Check the connections to the board and the
tank.
4 The LED is on and steady. Change the board.
6.5 Inspection and maintenance of the solar circuit
We recommend that you take out a maintenance contract providing for an annual or biannual check of the fluid level, the antifreeze protection, the pressure of the installation and the expansion vessel, its tightness and its general running.
6.6 solar regulator
The solar control system is governed by the boiler control system. All parameters and settings on the solar control system are managed from the boiler control panel.
¼Refer to the installation and maintenance instructions of the boiler.
6.7 Maintenance of the thermostatic mixing valve
The thermostatic mixer tap does not require any particular maintenance.
6. Checking and maintenance 220 SHL
19
06/01/2015 - 300028214-001-03
7 Warranty
7.1 General
You have just purchased one of our appliances and we thank you for the trust you have placed in our products.
Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Your installer and our customer support network are at your disposal at all times.
7.2 Warranty terms
France: The following provisions are not exlcusive of the buyer being
able to benefit from the legal warranty stipulated in Articles 1641 to 1648 of the Civil Code.
Belgium: The following provisions regarding the contractual warranty are not exclusive of the buyer being able to benefit from the legal provisions applicable in Belgium regarding hidden defects.
Switzerland: The application of the warranty is subject to the terms and conditions of sale, delivery and warranty of the company marketing products.
Portugal: The following provisions do not adversely affect consumers’ rights, as laid down in Decree-Law 67/2003 of 8 April amended by Decree-Law 84/2008 of 21 May, warranties relating to sales of consumer goods and other implementing rules.
Other countries: The following provisions are not exclusive of the buyer being able benefit from the legal provisions applicable regarding hidden defects in the buyer’s country.
Starting from the purchase date shown on the original installer’s invoice, your appliance has a contractual guarantee against any manufacturing defect.
The length of the guarantee is mentioned in the price catalogue. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified engineer).
In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following:
4 applicable local laws and regulations,
4 specific requirements relating to the installation, such as national
and/or local regulations,
4 the manufacturer’s instructions, in particular those relating to the
regular maintenance of the unit,
4 the rules of the profession.
220 SHL
7. Warranty
06/01/2015 - 300028214-001-03
20
The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs.
The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel.
Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled.
The legislation laid down by european directive 99/44/EEC, transposed by legislative decree No. 24 of 2 February 2002 published in O.J. No. 57 of 8 March 2002, continues to apply.
7. Warranty 220 SHL
21
06/01/2015 - 300028214-001-03
220 SHL 7. Warranty
06/01/2015 - 300028214-001-03
22
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
06/01/2015
300028214-001- 03
Loading...