Remcor LP350A/150S, LP650A/150S, LP650A/150S-B, LP650A/150S-BC, LP350A/150S-B Operator's Manual

...
SPIRAL LOW-PROFILE
Operator’s Manual
ICEMAKER-DISPENSER
MODEL:
LP350A/150S, -B, -BC LP650A/150S, -B, -BC LP650R/150S, -B, -BC
Part No. 91424 March 1997 Revision D
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment
âREMCOR INC: 1993 - 1995
PRINTED IN U.S.A
TABLE OF CONTENTS
SAFETY PRECAUTIONS 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNPACKING 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLA TION 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCATION 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PLUMBING 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODEL LP650R ONLY: REMOTE CONDENSER INSTALLATION 3. . . . . . . . . . . .
ICEMAKER 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REMOTE CONDENSER 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRE-CHARGED LINE SETS 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL (SEE FIGURE 4) 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEVERAGE SYSTEM 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BAG-IN-BOX OPTION 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START UP 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ICEMAKER 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEVERAGE SYSTEM 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADJUSTING WATER FLOW 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BAG-IN-BOX (BIB) GAS OPERATED SYRUP PUMPS 13. . . . . . . . . . . . . . . . . . . . .
OPERA TING INSTRUCTIONS 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page
ICEMAKER OPERATING INSTRUCTIONS 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLEANING INSTRUCTIONS 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DISPENSER SECTION 23...........................................
BEVERAGE / BAG-IN-BOX SYRUP SYSTEM 23. . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE/ADJUSTMENT PROCEDURE 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLEARING EVAPORATOR FREEZE-UP 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLEANING / REPLACING THE FILTER 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLEANING THE CONDENSER (AIR-COOLED UNIT) 25. . . . . . . . . . . . . . . . . . . . . .
MANUAL FILLING 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING GUIDE 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PARTS LIST 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY 40..............................................................
i
91424
TABLE OF CONTENTS (cont’d)
LIST OF FIGURES
FIGURE 1. PRE-CHARGED LINE SETS 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 2. PRE-CHARGED LINE SET INSTALLATION 5. . . . . . . . . . . . . . . . . . . . .
FIGURE 3. UNITS WITH BAG-IN-BOX PUMP OPTIONS 6. . . . . . . . . . . . . . . . . . .
FIGURE 4. STANDARD UTILITY LOCATIONS REAR VIEW 7. . . . . . . . . . . . . . . . .
FIGURE 5. MODEL “B” FLOW DIAGRAM 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 6. MODEL “BC” FLOW DIAGRAM 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 7. BEVERAGE SYSTEM SCHEMATIC 11. . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 8. LANCER VALVE 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 9. LP350/150 WIRING SCHEMATIC 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 10. LP 350 / 150 115 / 1 / 60 HZ WIRING DIAGRAM 17. . . . . . . . . . . . . . .
FIGURE 11. LP 650A / 150 WIRING SCHEMATIC 18. . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 12. LP 650R / 150 WIRING SCHEMATIC 19. . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 13. REFRIGERATION SCHEMATIC 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 14. REMOTE CONDENSER SYSTEM DIAGRAM 21. . . . . . . . . . . . . . . . . .
LIST OF TABLES
Page
TABLE 1. SPECIFICATIONS 2............................................
Manufactured Under One or More of the Following Patent Numbers:
3,211,336, 3,274,792, 3,393,839 , 3,517,860, 3,739,842, 4,215,803, 4,227,377, 4,300,3594,346,824
Canadian Patent Numbers912,514 (10/72), 936,855 (11,73), 4,429,543, 4,921,149
Other Patents Pending
91424
SAFETY PRECAUTIONS
Always d isconnect power to th e dispenser before servicing or cleaning. Never place han ds inside of ho pper or gate area without disconnecting power to the dispenser. Agitator rotation
occurs automa tically when the dispenser is energized! This ice dispenser has been specifically designed to provide protection against personal injury and eliminates
contamination of ice. To insure continued protection and sanit ation, observe the following
ALWAYS be sure the removable lid is properly installed to prevent unautho­rized access to the hopper interior and possible contamination of ice.
ALWAYS be sure the upper and lower front panels are securely fastened. ALWAYS keep area around the dispenser clean of ice cubes.
IMPORTANT INSTALLATION NOTICE
An IMI Cornelius model number 81COR01PS, Filter MUST BE INSTALLED in the water supply line to the ice­maker. Failure to do so may result in poor quality ice, low production output and may cause prema ture failure of icemaker e vaporator and void the extended evaporator warranty.
This icemaker is provided with a stainless steel evaporator, designed to last the life of the product. However, some of the chemicals in treated and untreated water, specifically chlorine and sulfur (sulfide), ha ve the ability to attack stainless steel and cause premature failure. An initial investment in proper water treatment will pay for itself in increased production, quality and long life of the product.
1 91424
DESCRIPTION
The REMCOR LOW PROFILE S.I.D. (Spiral Iceâ Icemaker Dispenser) is a unique, self-contained, fre e stand­ing style u nit which automatically makes hard, clear cube-quality ice and stores it in a sealed hopper for sanitary dispensing. The ice is made by a new, patented process on a spiral shaped stainless steel evaporator and pro­duces tube cube quality ice on the outside of the tubes. There are no augers, no compressing of flaked ice, no bearings and no high gear motor loads in the icemaking process. The unit has been designed to be simple, yet effective, to provide many years of trouble free operation.
Table 1. Specifications
Model LP350A LP650A LP650R
Compressor: HP 1/2 HP 3/4 HP 3/4 Refrigerant: R-22 / 1 lb. R502 / 2 lbs. R502 / 8 lbs. Voltage: 115 / 1 / 60 115 / 1 / 60 115 / 1 / 60 Amps: 16 Amps 16 Amps 16 Amps Circuit Ampacity:* 20 Amps 20 Amps 20 Amps Fuse Size: 20 Amps Time Delay 20 Amps Time Delay 20 Amps Time Delay Ice Storage Capacity: 150 lbs. 150 lbs. 150 lbs. Ice Making Capacity: Up to 350 lbs./24 hrs. 650 lbs./24 hrs. 650 lbs./24 hrs.
NOTE: *30 amps when unit is supplied with carbonator.
UNPACKING
1. With the unit upright carefully remove the shipping carton. Inspect fo r shipping damage and report any such dama ge to the shipper immediately.
2. Remove l ower front louvered panel for electrical and start-up process.
3. Remove shipping tape from storage hopper cover and agitator in storage hopper.
291424
INSTALLATION
WARNING: Only qualified personnel sh ou ld service internal components or electrical wiring.
LOCATION
Locate the icemaker dispenser indoors i n a well ventilated area. Avoid exposure to direct sunlight and/or heat caused by radiation. Ambient room temperature must be in the range of 60° to 90° F. Do not install unit in an enclosed area where heat build-up could be a problem. Note: Air flow direction and spacing required shown in Figure 1.
Consult Figure 1 for utility connection locations.
PLUMBING
Connect the icemaker to a cold, potable water source, suitable for drinking. This water source must comply wit h the basic p lumbing code of the Building Officials and Code Administrators International Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration. Do not install unit on a water softener line. It is recommended that a hand shut-off valve and strainer be used on the incoming supply line. (See Figure 1 for size an d location.) For proper operation of the incoming water supply pressure must be in the range of 30-90 PSIG. Install a pressure regulating valve if above this range!
IMPORTANT: To insure proper icemaker operation and also to reduce the frequ ency o f water-related service problems, a water filter should be installed. REMCOR recommends the use of IMI Cornelius filter, model number 81COR01PS.
For specific recom mendations on these filter systems for your local water conditions, consult with a distributor in your area or contact the filter manufacturer. Connect separate drain lines to all drain connections. See Figure 2 for size and location. These lines must pitch downward to and open drain and must contain no traps, or improper drainage will result. All drain connections must be in accordance with the basic plumbing code of the Building Officials and Code Administrators Interna­tional (BOCA) and local codes.
NOTE: In areas where con sisten tly warm water temperatures are encountered, the use of a pre-cooler
in the water line is recommended to maximize the ice production of this unit.
MODEL LP650R ONLY: REMOTE CONDENSER INSTALLATION
Remcor Prod ucts remote condenser systems come in three separate packages to complete one remote con­denser a pplication. They consist of the icemaker, the remote condenser and the interconnecting pre-charged line set.
Icemaker
The refrigeration system of a remote condenser systems is similar to a standard air cooled system with the fol­lowing exceptions described below:
Mixing Valve
This valve is located at the condenser and serves as a head pressure regulating valve. As the temperature at the condenser drops, the head pressure at the receiver will drop. When this pressure reaches 225 PSIG, the mixing valve by-passes the condenser and meters hot discharge gas into the receiver, maintaining the 225 PSIG receiver pressure.
3 91424
Liquid Receiver
In the icemaker, a 10# liquid receiver is installed to accept the large refrigerant charge that is n ot needed when the condenser is subjected to higher temperatures.
Pump Down System
To prevent refrigeration migration to the compressor during the off-cycle due to refrigerant to oil attraction or temperature differential between condenser and compressor, a pump down system has been utilized in this re­mote condenser system.
A solenoid valve has been installed in the liquid line to the TXV and is open during normal icemaking operation. When the bin stat opens, the solenoid valve closes and stops the flow of refrigerant to the low side of the sys­tem. The compressor is kept running by the pump down low pressure control, thereby pumping any remaining refrigerant out of the low side into the high side liquid receiver. When the low die pressures reaches 5# the com­pressor is turned off. The low side control is a recycling control and if refrigerant leaks into the low side and the pressures reaches 55# the compressor is restarted, removing the unwanted refrigerant.
REMOTE CONDENSER
The remote condenser is an air-cooled fin-pack that can be mounted in the horizontal or vertical position. Care should be taken in the installation site to reduce prevailing wind restraints and to keep the air entrance away from other systems air discharge. This will keep the remote system operating at its’ designed efficiencies.
This remote condenser system is designed to operate in temperatures of --20 degrees F through 120 degrees F. These limits should be considered when installing equipment.
The remote condenser is supplied with a low ambient mixing valve that assures that the receiver will under all temperatures have a liquid pressure of 225 PSIG. This is required for proper txv operation and to assure suffi­cient pressure when hot gas by-pass is required. This valve eliminates the requirement of any fan cycling con­trols.
The remote condenser is not required to cycle with the hot gas portion of the ice making cycle. The wiring of the condenser can either be wired to a separate power source or, to allow the condenser to shut down with the ice­maker, it may be wired per the electrical diagram enclosed.
NOTE: When servicing remote condenser make sure the power is disconnected.
Electrical volt age requirements are rated on the condenser f or separate power sourcing.
PRE-CHARGED LINE SETS
The pre-charged line sets (25 ft. long or 40 ft. long) join tog ether a totally sealed pre-charged system ready for operation after installation. The line set is supplied with 3/8” quick couplings for the liquid line and 1/2” quick couplings for the discharge line. As these couplings are “one time” couplings, if they are ever removed and re­installed, the system refrigerant charge will be lost and an evacuation and recharge of the system will be neces­sary.
DISCHARGE LINE
1/2-IN. DIA.
FIGURE 1. PRE-CHARGED LINE SETS
REMOTE
CONDENSER
LIQUID LINE
3/8-IN. DIA.
ICEMAKER
491424
When routing pre-charged line set, make sure that couplings are lubricated with refrigerant oil to assure proper trouble free assemble.
5502 COUPLING
HALF TALL FLANGE
5505 COUPLING HALF
6-HOLE FLANGE PART NO. 150-22
PANEL OR BULKHEAD
UNION NUT
FIGURE 2. PRE-CHARGED LINE SET INSTALLATION
1. Remove d ust cap and plugs if used, making sure that component synthetic seals are intact.
2. Wipe off coupling seals and threaded surfaces with a clean cloth to prevent the inclusion of dirt or any for­eign material in the system.
3. LUBRICATE rub ber seal in male half with refrigeration oil. Thread coupling halves together by hand to in­sure prop er mating of threa ds, Use proper size wrenches (on coupling body hex and on union nut) and tighten until coupling bodies “bottom” or a definite resistance is felt. Using a marker or ink pen, mark a line lengthwise from the coupling hex to the bulkhead. then tighten an additional 1/6 to 1/4 turn. The misalign­ment of the line will show the degree of tightening. This final turn is necessary to insure tha t the knife edge metal seal bites into the brass seat of the coupling halves, forming the leakproof joint. If torque wrench is used, the following torque values are recommended:
Coupling Size Ft. Lbs.
--8 35
--12 50
--16 65
Routing of line sets are a very important factor in trouble free installation.
1. Make sure condenser will be located above the icemaker.
2. Route line sets to keep excess tubing inside of building.
3. When coiling excess tubing make sure coils runs vertically with the flow of refrigerant.
ELECTRICAL (see figure 4 )
A 4 X 2 junction box is located at the rear of the unit for the supply hook-up. Connect the icemaker to its’ own individual circuit per the National Electric Code and Local Code (see SPECIFICATIONS for ampacity and fuse size).
IMPORTANT: The wire size must be adequate for the ampacity rating and the supply voltage must be within a range of ± 10% for proper icemaker operation.
NOTE: That the unit requires a 2-wire systems plus earth ground for proper operation.
5 91424
34 3/4
30
10 1/2
10
34
AIR FLOW
TOP ACCESS FOR MANUAL
FILL OF HOPPER
OPTIONAL
OPTIONAL
4 1/8
5 1/2
2
CUPS CUPS CUPS CUPS
26 1/4
30
32
STRAWS
32 3/8
OPENING FOR BEV
LINES 6 1/2 X 8 1/2
15 5/8
AIR FLOW
KICK PLATE
REMOVABLE
6 3/8
(OPTIONAL)
1 1/28
SINK
BAG IN BOX SYRUP
PUMPS (8) (OPTIONAL)
ALL PANELS REMOVABLE
AIR FLOW
AIR EXHAUST
(LEFT OR RIGHT SIDE)
FRONT AND SIDE KICK
PLATE (OPTIONAL)
FIGURE 3. UNIT S WITH BAG-IN-BOX PUMP OPTIONS
PUSH FOR ICE
11
64 3/8
45
AIR FLOW
1/2
3 19/325 3/4
691424
*115V, 1/4HP, 4 AMP REMOTE FAN MOTOR FOR REMCOR-SUPPLIED REMOTE CONDENSER
OPTIONAL CARBONATOR
(LOWER REAR LOUVERED PANEL REMOVED)
WHITE (NEUTRAL)
GREEN (GROUND)
BLACK (HOT)
4? X 2? HANDY BOX FOR
SUPPLY HOOKUP
SUPPLY CONDUIT (ROUTE
THROUGH BOTTOM OPENING)
ROUTE ALL UTILITIES THROUGH BOTTOM OPENING:
4? X 2? HANDY BOX FOR REMOTE
*LP 650R ONLY:
CONDENSER FANHOOKUP
22 7/8
4 1/2
1. ICEMAKER W ATER IN 3/8-IN. I.D. TUBING
2. CARBONATED WATER IN 3/8-IN. I.D.
3. TUBING (COLD PLATE UNITS)
4. DRAIN 1-IN. I.D. BY 1 1/4-IN O.D. TUBING
LP 650R ONLY: REMOTE
CONDENSER LINE
CONNECTIONS
2 7/8
1 1/4
FIGURE 4. STANDARD UTIL ITY LOCATIONS REAR VIEW
7 91424
BEVERAGE SYSTEM
“B”, “-BC” Models: connect the beverage system product lines as indicated in “B” and “BC” units, Figures 5 and 6 respectively. This work should be down by a qualified service person. Note that the hoses are marked with number S1, etc. for syrup connection and “CW” for carbonated water connections.
Bag-In-Box Optio n
The unit has a built-in cold plate, carbonator, beverage fau cets and syrup pumps. It is de signed to be supplied directly from the Bag-in-Box syrup containers with no additional cooling required. (see Figure 7)
Installation
1. Connect the beverage system syrup lines (tubing marked S1 through S10) to the Bag-in-Box containers.
2. Hook up th e carbonator water line (marked “CW”) to a potable water supply.
3. Hoot up the carbonator and syrup pump CO2line (marked “CO2”) to the CO2supply tan k.
NOTE: This work should be done by a qualified service person.
891424
TANK
2
CO
WATER
SUPPLY
REGULATORS
TANKS
SYRUP
REGULATOR
60 -- 100 PSIG
OPTIONAL PRESSURE
(7 THRU 10) ARE PERMITTED
4 ADDITIONAL FAUCETS AND TANKS
BEER
DIET OR ROOT
OPTIONAL FOR
5 -- 15
PSIG
FILTER
FOR REFERENCE ONLY
NOT FOR CONSTRUCTION
CARBONATOR
FAUCETS
FIGURE 5. MODEL “B” FLOW DIAGRAM
9 91424
COLD PLATE
ITEMS OUTSIDE BROKEN LINES
ARE NOT INCLUDED. (2) CENTER
FAUCETS CAN BE CONVERTED
TO NON--CARBONATED WATER.
TANK
2
CO
WATER
SUPPLY
REGULATORS
FOR REFERENCE ONLY
NOT FOR CONTRUCTION
SYRUP
TANKS
OPTIONAL
PRESSURE
REGULATOR
60--100 PSIG
15-50 PSIG
OPTIONAL
ROOT BEER
FOR DIET OR
5--15
PSIG
4 ADDITIONAL FAUCETS AND
TANKS (7THRU 10) ARE PERMITTED
FILTER
CARBONATOR
FAUCETS
FIGURE 6. MODEL “BC” F LOW DIAGRAM
COLD PLATE
TO NON-CARBONATED WATER
FAUCETS CAN BE CONVERTED
ITEMS OUTSIDE BROKEN LINES
ARE NOT INCLUDED (2) CENTER
1091424
CARBONATED
WATER
TO
ICE
MAKER
CHECK VALVE
PLAIN WATER
WATER
TANK
1 2 3 4 5 6 7 8
CO2CHECK
VALVE
CARBONATOR
1
2 3 4 5
DETAIL A
OPTIONAL
PRESSURE REGULATOR
DUAL CHECK
VALVE
WATER
PUMP
90-100 PSIG
REGULATOR
WATER
SUPPLY
6 7 8
CO2TANK
SYRUP OUT
(TYP)
BAG-N-BOX
PUMPS (8)
TO BAG-N-BOX
SYRUP (8)
2
1 876543CW
ICE COOLED COLD PLATE
21 3 4 5
FAUCETS
(FRONT OF UNIT)
SEE DETAIL A
6 7 8
SYRUP PUMP
DISTRIBUTOR (CO2)
SYRUP PUMP CO
REGULATOR (50PSIG)
2
CO2(50PSI)
TYP
BAG-N-BOX
SYRUP (TYP)
FIGURE 7. BEVERAGE SYSTEM SCHEMATIC
11 91424