This water heater complies with ANSI Z21.10.1-current
edition regarding the accidental or unintended ignition of
fl ammable vapors, such as those emitted by gasoline.
GAS WATER HEATER
FOR POT ABLE W A TER HEATING ONLY .
NOT FOR USE IN MOBILE HOMES.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
• Safety Instructions
• Installation
• Operation
INSTALLER:
• AFFIX THESE INSTRUCTIONS TO OR ADJACENT
TO THE WATER HEATER.
OWNER:
• RETAIN THESE INSTRUCTIONS AND WARRANTY
FOR FUTURE REFERENCE. RETAIN THE
ORIGINAL RECEIPT AS PROOF OF PURCHASE.
WARNING: Gas leaks can not always be detected by
smell.
Gas suppliers recommend that you use a gas detector
approved by UL or CSA.
For more information, contact the your gas supplier.
If a gas leak is detected, follow the “WHAT TO DO IF YOU
SMELL GAS” instructions.
• Care and Maintenance
• Troubleshooting
• Parts List
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
LOW LEAD
COMPLIANT
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE RELIANCE CUSTOMER CARE CENTER AT 1-800-365-4054
OR WWW.RELIANCEWATERHEATERS.COM.
PRINTED IN THE U.S.A. 1013 PART NO. 320385-002
1
TABLE OF CONTENTS
Water Heater Safety .............................................................................................................................................................................. 1
Safe Installation, Use and Service ...................................................................................................................................................... 3
Installing your Gas Water Heater ..................................................................................................................................................... 6-8
Important Information About Your Water Heater ...................................................................................................................... 6
Consumer Information ............................................................................................................................................................. 6
Unpacking the Water Heater ................................................................................................................................................... 6
Site Location ............................................................................................................................................................................ 7
Clearances and Accessibility ................................................................................................................................................... 8
State of California .................................................................................................................................................................... 8
Gas Supply ....................................................................................................................................................................................... 9-10
Gas Requirements .................................................................................................................................................................... 9
Gas Piping ............................................................................................................................................................................... 9
Gas Pressure ........................................................................................................................................................................... 9
Gas Pressure Testing ............................................................................................................................................................... 9
LP Gas Only ........................................................................................................................................................................... 10
Combustion Air and Ventilation ....................................................................................................................................................11-15
Unconfined Space ...................................................................................................................................................................11
Confined Space ......................................................................................................................................................................11
All Air from Inside the Building ............................................................................................................................................... 12
All Air from Outdoors .............................................................................................................................................................. 12
Louvers and Grilles ........................................................................................................................................................... 12-13
Vent Pipe System .................................................................................................................................................................. 13
Vertical Exhaust Gas Vent ................................................................................................................................................ 14-15
Water System Piping ..................................................................................................................................................................... 15-18
Temperature & Pressure Relief Valve .................................................................................................................................... 17
T&P Relief Valve and Pipe Installation .................................................................................................................................. 17
Important Information About this Water Heater ...............................................................................................................................18
Operating Your Water Heater ........................................................................................................................................................ 19-25
Checking the Draft ................................................................................................................................................................. 21
Water Temperature Regulation ......................................................................................................................................... 21-22
Operating the Temperature Control System .....................................................................................
Draining and Flushing ............................................................................................................................................................. 24
Temperature and Pressure Relief Valve ........................................................................................................................... 24-25
Maintenance of Your Water Heater .............................................................................................................................................. 25-29
Replacement Parts ................................................................................................................................................................ 25
Removing the Manifold/Burner Assembly ............................................................................................................................... 25
Removing the Burner from the Manifold/Burner Assembly ................................................................................................... 25
Replacing the Pilot / Thermopile Assembly ........................................................................................................................... 26
External Inspection & Cleaning of the Base-Ring Filter ........................................................................................................ 27
Cleaning the Combustion Chamber and Flame-arrestor ....................................................................................................... 27
Replacing the Manifold Burner/Assembly .............................................................................................................................. 27
Piezoelectric Igniter System .................................................................................................................................................. 28
Testing the Igniter System ..................................................................................................................................................... 28
Removing and Replacing the Gas Control Valve/Thermostat ............................................................................................... 28
FVIR System Operational Checklist ...................................................................................................................................... 29
Pilot Light Troubleshooting Flowchart ............................................................................................................................................ 31
Status Light and Diagnostic Code Troubleshooting Chart ........................................................................................................ 32-33
Repair Parts ................................................................................................................................................................................... 36-37
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your water heater to warn you and
others of a potential hazard. Read and obey all safety messages and instructions throughout this manual. It is very important
that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will
DANGER
WARNING
CAUTION
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety
message and how to avoid the risk of injury.
The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of
substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses
to warn of potential exposure to such substances.
• WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other
reproductive harm.
• This appliance can cause low-level exposure to some of the substances included in the act.
result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, could
result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, could result in property damage
IMPORTANT DEFINITIONS
• Qualified Technician: A qualified technician must have ability equivalent to a licensed tradesman in the fields of
plumbing, air supply, venting, and gas supply, including a thorough understanding of the requirements of the National
Fuel Gas Code as it relates to the installation of gas fired water heaters. The qualified technician must also be
familiar with the design features and use of flammable vapor ignition resistant water heaters, and have a thorough
understanding of this instruction manual.
• Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of
plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National
Fuel Gas Code as it relates to the installation of gas fired water heaters. The service agency must also have a
thorough understanding of this instruction manual, and be able to perform repairs strictly in accordance with the
service guidelines provided by the manufacturer.
• Gas Supplier: The Natural Gas or Propane Utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of
gas piping up to and including the Natural Gas meter or Propane storage tank of a building. Many gas suppliers also
offer service and inspection of appliances within the building.
FLAMM ABLES
SAFETY PRECAUTIONS
WARNING
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this
or any other appliance. Storage of or use of
Flammable Vapors
Read and follow water heater warnings and instructions.
gasoline or other flammable vapors or liquids in the
vicinity of this or any other appliance can result in
serious injury or death.
3
Fire or Explosion Harzard
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Avoid all ignition sources if you smell Natural or LP gas.
Do not expose water heater control to excessive gas
pressure.
Use only gas shown on rating plate.
Maintain required clearances to combustibles.
Keep ignition sources away from faucets after extended
period of non-use.
Read instruction manual before
installing, using or servicing
water heater.
Fire or Explosion Harzard
Hydrogen gas can be produced in a hot water system after
a period of non-use (generally two or more weeks).
Hydrogen gas is extremely flammable and can ignite.
To return hot water system to service, open a hot water
faucet in kitchen for several minutes before using electrical
appliances.
Do not smoke or have open flame near faucet while it is open.
Leave hot water faucet open until the sound of escaping
air stops.
After extended period of non-use,
purge gases from hot water system.
4
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe
B Draft Hood
C Anode (Not Shown)
D Hot Water Outlet
E Insulation
F Gas Supply Piping
G Manual Gas Shut-off Valve
H Ground Joint Union
I Sediment Trap
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* SEDIMENT TRAP AS REQUIRED
BY LOCAL CODES.
TO VENT
TERMINATION ON
ROOF
INSTALL THERMAL EXPANSION
A
TANK IF WATER HEATER IS
CLOSED WATER SYSTEM
J Inner Door
K Outer Door
L Union
M Inlet Water Shut-off Valve
N Cold Water Inlet
O Inlet Dip Tube
P Temperature-Pressure Relief Valve
Q Rating Plate
R Flue Baffle
(S) GAS CONTROL VALVE/
THERMOSTAT
INSTALLED IN A
VAC
S Gas Control Valve/Thermostat
T Drain Valve
U Manifold/Burner Assembly
V Flue
W Metal Drain Pan
X Piezo Igniter
Y Base-Ring Filter
Gas Control/Temperature Knob
120°F
Status
Mark
Light
L
D
R
F
G
H
I
B
E
S
V
U
M
N
VACUUM RELIEF
O
T
VALVE
*INSTALL PER
LOCAL CODES
P
Q
DISCHARGE PIPE
(DO NOT CAP OR PLUG.)
Igniter
Temperatures shown are approximates and may vary.
(U) MANIFOLD/BURNER ASSEMBLY
MAIN BURNER
THERMOPILE
MANIFOLD DOOR
6” MAXIMUM
AIR GAP
PILOT TUBE
IGNITER WIRE
MANIFOLD
TUBE
Y
W
* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
J
X
K
FLOOR DRAIN
5
INSTALLING YOUR GAS WATER HEATER
Important Information About This Water Heater
This gas water heater was manufactured to voluntary
safety standards to reduce the likelihood of a flammable
vapor ignition incident. New technology used in meeting
these standards makes this product more sensitive to
installation errors or improper installation environments.
Please review the Installation Checklist found at the end of
the installation instructions section and make any required
installation upgrades or changes.
Consumer Information
This water heater is design-certified by CSA International
as a Category I, non-direct vented water heater which
takes its combustion air either from the installation area or
from air ducted to the unit from the outside.
This water heater must be installed according to all local
and state codes or, in the absence of local and state
codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition. This is available from the following:
CSA America, Inc.
8501 East Pleasant Valley Road
Cleveland, OH 44131
National Fire Protection Agency
1 Batterymarch Park
Quincy, MA 02269
Check your phone listings for the local authorities having
jurisdiction over your installation.
Consumer Responsibilities
Unpacking the Water Heater
WARNING
Excessive Weight Hazard
Use two or more people to move and install the water heater.
Failure to do so can result in injury (including back injury).
IMPORTANT: Do not remove any permanent instructions,
labels, or the data label from either the outside of the
water heater or on the inside of water heater panels.
• Remove exterior packaging and place installation components aside.
• Inspect all parts for damage prior to installation and
start-up.
• Completely read all instructions before attempting to
assemble and install this product.
• After installation, dispose of/recycle all packaging
materials.
This manual has been prepared to acquaint you with the
installation, operation, and maintenance of your gas water
heater and provide important safety information in these
areas.
Read all of the instructions thoroughly before attempting
the installation or operation of this water heater.
Do not discard this manual. You or future users of this
water heater will need it for future reference.
Service to the FVIR System should only be performed by a
qualified technician.
Examples of a qualified technician include: licensed
plumbers, authorized gas company personnel, and
authorized service personnel.
IMPORTANT: The manufacturer and seller of this water
heater will not be liable for any damages, injuries, or
deaths caused by failure to comply with the installation and
operating instructions outlined in this manual.
If you lack the necessary skills required to properly install
this water heater, or you have difficulty following the
instructions, you should not proceed but have a qualified
technician perform the installation of this water heater.
Massachusetts code requires this water heater to be
installed in accordance with Massachusetts Plumbing and
Fuel Gas Code 248 CMR Section 2.00 and 5.00.
A rating plate identifying your water heater can be found
on the front of your water heater. When referring to your
water heater, always have the information listed on the
rating plate readily available. Retain your original receipt
as proof of purchase.
6
Location Requirements
WARNING
Carbon Monoxide Poisoning Hazard
Do not install in a mobile home.
Doing so can result in carbon monoxide poisoning and death.
The FVIR System is designed to reduce the risk of
flammable vapor-related fires. The patented system
protects your family by trapping the burning vapors
within the water heater combustion chamber through the
special flame-arrestor. The burning vapors literally “burn
themselves out” without escaping back into the room.
In the event of a flammable vapor incident, the FVIR
System disables the water heater by shutting off the gas
supply to the water heater’s burner and pilot, preventing
re-ignition of any remaining flammable vapors in the area.
This will not prevent a possible fire/explosion if the igniter
is depressed and flammable vapors have accumulated
in the combustion chamber with the pilot light off. If you
suspect a flammable vapor incident has occurred, do not
use this appliance. Do not attempt to light this appliance,
or depress the igniter button if you suspect flammable
vapors have accumulated inside or outside the appliance.
Immediately call a qualified technician to inspect the
appliance. Water heaters subjected to a flammable vapors
incident will show a discoloration on the flame-arrestor and
require replacement of the entire water heater.
WARNING
FLAMM ABLES
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance. Storage of or use of gasoline or other
flammable vapors or liquids in the vicinity of this or
any other appliance can result in serious injury or
death.
Read and follow water heater warnings and
instructions
Do not use or store flammable products such as gasoline,
solvents, or adhesives in the same room or area near the
water heater. If such flammables must be used, all gas
burning appliances in the vicinity must be shut off and their
pilot lights extinguished. Open the doors and windows for
ventilation while flammable substances are in use.
Flammable Vapors
If flammable liquids or vapors have spilled or leaked in
the area of the water heater, leave the area immediately
and call the fire department from a neighbor’s home. Do
not attempt to clean the spill until all ignition sources have
been extinguished.
WARNING
Fire or Explosion Hazard
• Read instruction manual before installing, using or
servicing water heater.
• Improper use may result in fire or explosion.
• Maintain required clearances to combustibles.
Keep combustibles such as boxes, magazines, clothes, etc. away
from the water heater area.
Site Location
• Select a location near the center of the water piping
system. The water heater must be installed indoors
and in a vertical position on a level surface. DO NOT
install in bathrooms, bedrooms, or any occupied room
normally kept closed.
• Locate the water heater as close to the chimney or gas
vent as practical. Consider the vent system piping and
combustion air supply requirements when selecting the
water heater location. The venting system must be able
to run from the water heater to termination with minimal
length and elbows.
• Locate the water heater near the existing gas piping.
If installing a new gas line, locate the water heater to
minimize the pipe length and elbows.
• The water heater should be located in an area not
subject to freezing temperatures. Water heaters
located in unconditioned spaces (i.e., attics,
basements, etc.) may require insulation of the water
piping and drain piping to protect against freezing.
The drain and controls must be easily accessible for
operation and service. Maintain proper clearances as
specified on the rating plate.
• Do not locate the water heater near an air-moving
device. The operation of air-moving devices such
as exhaust fans, ventilation systems, clothes dryers,
fireplaces, etc., can affect the proper operation of the
water heater. Special attention must be given to conditions these devices may create. Flow reversal of flue
gases may cause an increase of carbon monoxide
inside of the dwelling (Figure 1B).
• If the water heater is located in an area that is
subjected to lint and dirt, at least once annually, clean
the base-ring filter and flame-arrestor. Refer to the
“Maintenance of your Water Heater” section.
NOTE: This water heater must be installed according to all
local and state codes or, in the absence of local and state
codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition.
7
IMPORTANT: The water heater should be located in an area
where leakage of the tank or connections will not result in
damage to the area adjacent to the water heater or to lower
floors of the structure. Due to the normal corrosive action of
water, the tank will eventually leak after an extended period
of time. Also any external plumbing leak, including those
from improper installation, may cause early failure of the
tank due to corrosion if not repaired. If the homeowner is
uncomfortable with making the repair a qualified technician
should be contacted. A suitable metal drain pan should be
installed under the water heater as shown below, to help
protect the property from damage which may occur from
condensate formation or leaks in the piping connections
or tank. The pan must limit the water level to a maximum
depth of 1-3/4” and be two inches wider than the heater
and piped to an adequate drain. NOTE: The pan must not
restrict combustion air flow. Locate the water heater near a
suitable indoor drain. Outside drains are subject to freezing
temperatures which can obstruct the drain line. The piping
should be at least 3/4” ID and pitched for proper drainage.
METAL
DRAIN
PAN
AT LEAST 2” GREATER THAN THE
DIAMETER OF THE WATER HEATER.
FIGURE 1A.
PIPED TO AN
ADEQUATE DRAIN
Water heater life depends upon water quality, water usage,
water temperature and the environment in which the
water heater is installed. Water heaters are sometimes
installed in locations where leakage may result in property
damage, even with the use of a drain pan piped to a
drain. However, unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device
used in conjunction with a piped drain pan. These devices
are available from some plumbing supply wholesalers and
retailers, and detect and react to leakage in various ways:
• Sensors mounted in the drain pan that trigger an alarm
or turn off the incoming water to the water heater when
water is detected.
• Sensors mounted in the drain pan that turn off the
water supply to the entire home when water is detected
in the drain pan.
• Water supply shut-off devices that activate based on
the water pressure differential between the cold water
and hot water pipes connected to the water heater.
• Devices that will turn off the gas supply to a gas water
heater while at the same time shutting off its water
supply.
EXHAUST FAN
REVERSE FLOW
OF GASES
FIGURE 1B.
Clearances and Accessibility
NOTE: Minimum clearances from combustible surfaces are
stated on the rating plate adjacent to the gas control valve/
thermostat of the water heater.
The water heater is certified for installation on a
combustible floor.
• IMPORTANT: If installing over carpeting, the carpeting
must be protected by a metal or wood panel beneath
the water heater. The protective panel must extend
beyond the full width and depth of the water heater by
at least three inches (76.2mm) in any direction; or if in
an alcove or closet installation, the entire floor must be
covered by the panel.
• Figure 2 may be used as a reference guide to locate
the specific clearance locations. A minimum of 24 inches of front clearance should be provided for inspection
and service.
VENT
TOP
TO
CEILING
SIDES
BACK
TOP
VIEW
SIDES
FRONT
24” MINIMUM
FOR SERVICE
FIGURE 2.
State of California
NOTE: The water heater must be braced, anchored, or
strapped to avoid moving during an earthquake. Contact
local utilities for code requirements in your area, visit http://
www.dsa.dgs.ca.gov, or call 1-916-445-8100 and request
instructions.
8
GAS SUPPLY
WARNING
Explosion Hazard
• Use a new CSA approved gas supply line.
• Install a shut-off valve.
• Do not connect a natural gas water heater to an L.P. gas
supply.
• Do not connect an L.P. gas water heater to a natural gas
supply.
• Failure to follow these instructions can result in death,
explosion, or carbon monoxide poisoning.
Gas Requirements
IMPORTANT: Read the rating plate to be sure the water
heater is made for the type of gas you will be using in
your home. This information will be found on the rating
plate located near the gas control valve/thermostat. If the
information does not agree with the type of gas available,
do not install or light. Call your dealer.
NOTE: An odorant is added by the gas supplier to the gas
used by this water heater. This odorant may fade over an
extended period of time. Do not depend upon this odorant
as an indication of leaking gas.
Gas Piping
The gas piping must be installed according to all local and
state codes or, in the absence of local and state codes, the
“National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current
edition.
Tables 1 and 2 on the following page provide a sizing
reference for commonly used gas pipe materials. Consult
the “National Fuel Gas Code” for the recommended gas
pipe size of other materials.
NOTE: Use pipe joint compound or teflon tape marked as
being resistant to the action of petroleum [Propane (L.P.)]
gases (See Figure 3.)
1. Install a readily accessible manual shut-off valve in the
gas supply line as recommended by the local utility.
Know the location of this valve and how to turn off the
gas to this unit.
2. Install a sediment trap (if not already incorporated
as part of the water heater) as shown. The sediment
trap must be no less than three inches long for the
accumulation of dirt, foreign material, and water
droplets.
3. Install a ground joint union between the gas control
valve/thermostat and the manual shut-off valve. This
is to allow easy removal of the gas control valve/
thermostat.
4. Turn the gas supply on and check for leaks. Test all
connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak.
Correct any leak found.
Manual Gas
Shut-off Valve
Ground
Joint
Union
Check with local
utility for
minimum height
3” Minimum
Drip Leg
FIGURE 3.
6” Maximum
Air Gap
Gas Pressure
WARNING
Explosion Hazard
• Gas leaks can not always be detected by smell.
• Gas suppliers recommend that you use a gas
detector approved by UL or CSA.
• For more information, contact your gas supplier.
• If a gas leak is detected, follow the “What to do if you
smell gas” instructions on the cover of this manual.
IMPORTANT: The gas supply pressure must not exceed the
maximum supply pressure as stated on the water heater’s rating
plate. The minimum supply pressure is for the purpose of input
adjustment.
Gas Pressure Testing
IMPORTANT: This water heater and its gas connection must
be leak tested before placing the appliance in operation.
• If the code requires the gas lines to be tested at a
pressure exceeding 14” W.C., the water heater and its
manual shut-off valve must be disconnected from the gas
supply piping system and the line capped.
• If the gas lines are to be tested at a pressure less than
14” W.C., the water heater must be isolated from the gas
supply piping system by closing its manual shut-off valve.
NOTE: Air may be present in the gas lines and could prevent
the pilot from lighting on initial start-up. The gas lines should
be purged of air by a qualified technician after installation of
the gas piping system. While purging the gas piping system
of air, insure that the fuel is not spilled in the area of the
water heater installation, or any source of ignition. If the
fuel is spilled while purging the piping system of air follow
the “WHAT TO DO IF YOU SMELL GAS” instructions on
the cover of this manual.
9
LP Gas Only
WARNING
Explosion Hazard
Have a qualified technician make sure that the L.P. gas
operating pressure does not exceed 13” water column.
Examples of a qualified person include: licensed
plumbers, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Liquefied petroleum gas is over 50% heavier than air
and in the occurrence of a leak in the system, the gas
will settle at floor level. Basements, crawl spaces, closets
and areas below ground level will serve as pockets for
the accumulation of gas. Before lighting an L.P. gas water
heater, smell all around the appliance at floor level. If you
smell gas, follow the instructions as given in the warning
on the front page.
When your L.P. tank runs out of fuel, turn off the gas at
all gas appliances including pilot lights. After the tank is
refi lled, all appliances must be re-lit according to their
manufacturer’s instructions.
10
COMBUSTION AIR & VENTILATION
WARNING
Carbon Monoxide Warning
Water heater must be vented to outdoors.
Vent must be installed by a qualified technician using
the installation instructions.
Examples of a qualified technican include: gas
technicians, authorized gas company personel, and
authorized service persons.
Failure to so do can result in death or carbon monoxide
poisoning.
IMPORTANT: Air for combustion and ventilation must not
come from a corrosive atmosphere. Any failure due to
corrosive elements in the atmosphere is excluded from
warranty coverage.
The following types of installation (not limited to the
following) will require outdoor air for combustion due to
chemical exposure and may reduce but not eliminate the
presence of corrosive chemicals in the air:
• beauty shops
• photo processing labs
• buildings with indoor pools
• water heaters installed in laundry, hobby, or craft
rooms
• water heaters installed near chemical storage areas
Combustion air must be free of acid-forming chemicals such
as sulfur, fluorine, and chlorine. These elements are found
in aerosol sprays, detergents, bleaches, cleaning solvents,
air fresheners, paint, and varnish removers, refrigerants,
and many other commercial and household products. When
burned, vapors from these products form highly corrosive acid
compounds. These products should not be stored or used
near the water heater or air inlet.
Combustion and ventilation air requirements are determined
by the location of the water heater. The water heater may
be located in either an open (unconfined) area or in a
confined area or small enclosure such as a closet or small
room. Confined spaces are areas with less than 50 cubic
feet for each 1,000 BTUH of the total input for all gas-using
appliances.
Unconfined Space
A water heater in an unconfined space uses indoor air for
combustion and requires at least 50 cubic feet for each
1,000 BTUH of the total input for all gas appliances. The
table below shows a few examples of the minimum square
footage (area) required for various BTUH inputs.
TABLE 3
Minimum
BTUH Input
30,0001889 x 21
45,00028114 x 20
60,00037515 x 25
75,00046915 x 31
90,00056320 x 28
105,00065720 x 33
120,00075025 x 30
135,00084428 x 30
IMPORTANT:
• The area must be open and be able to provide the
proper air requirements to the water heater. Areas that
are being used for storage or contain large objects
may not be suitable for water heater installation.
• Water heaters installed in open spaces in buildings
with unusually tight construction may still require outdoor air to function properly. In this situation, outside
air openings should be sized the same as for a confined space.
• Modern home construction usually requires supplying
outside air into the water heater area.
Square
Feet with
8’ Ceiling
Typical Room
with 8’ Ceiling
Confined Space
For the correct and proper operation of this water heater,
ample air must be supplied for the combustion, ventilation,
and dilution of flue gases. Small enclosures and confined
areas must have two permanent openings so that sufficient
fresh air can be drawn from outside of the enclosure. One
opening shall be within 12 inches of the top and one within
12 inches of the bottom of the enclosure as shown in
Figure 4.
The size of each opening (free area) is determined by the
total BTUH input of all gas utilization equipment (i.e., water
heaters, furnaces, clothes dryers, etc.) and the method by
which the air is provided. The BTUH input can be found
on the water heater rating plate. Additional air can be
provided by two methods:
1. All air from inside the building.
2. All air from outdoors.
11
PERMANENT
T
OPENINGS TO
HE OUTSIDE OR
ADDITIONAL
ROOMS WITHIN
THE BUILDING
12” MAXIMUM
CLOSET
OR
OTHER
CONFINED
SPACE
fresh air can be taken from the outdoors or from crawl or
attic spaces that freely communicate with the outdoors.
Attic or crawl spaces cannot be closed and must be
properly ventilated to the outside.
Ductwork must be of the same cross-sectional area as
the free area of the opening to which they connect. The
minimum dimension of rectangular air ducts cannot be less
than three inches.
The size of each of the two openings is determined by the
method in which the air is to be provided. Refer to Table
4 to calculate the minimum free area for each opening.
Figures 6, 7, 8A and 8B are typical examples of each
method.
Louvers and Grilles
12” MAXIMUM
FIGURE 4.
In calculating free area for ventilation and combustion
air supply openings, consideration must be given to the
blocking effect of protection louvers, grilles, and screens.
All Air from Inside the Building
When additional air is to be provided to the confined area
from additional room(s) within the building, the total volume
of the room(s) must be of sufficient size to properly provide
the necessary amount of fresh air to the water heater
and other gas utilization equipment in the area. If you are
unsure that the structure meets this requirement, contact
your local gas utility company or other qualified agency for
a safety inspection.
Each of the two openings shall have a minimum free area
of 1 square inch per 1,000 BTUH of the total input rating of
all gas utilization equipment in the confined area, but not
less than 100 square inches (Figure 5).
These devices can reduce airflow, which in turn may
require larger openings to achieve the required minimum
free area. Screens must not be smaller than 1/4” mesh. If
the free area through a particular design of louver or grille
is known, it should be used in calculating the specified
free area of the opening. If the design and free area are
not known, it can be assumed that most wood louvers will
allow 20 - 25% of free area while metal louvers and grilles
will allow 60 - 75% of free area.
Louvers and grilles must be locked open or interconnected
with the equipment so that they are opened automatically
during equipment operation.
Keep louvers and grilles clean and free of debris or other
obstructions.
TABLE 4
CONFINED
SPACE
Minimum Free Area of Permanent Openings for
Ventilation and Combustion Air Supply - All Air from
Outdoors Only.
Based on total BTUH input rating for all utilizing
equipment within the confi ned space.
PERMANENT
OPENINGS
1 SQUARE
INCH/1000
BTUH
(MINIMUM
100 SQ. IN.)
FIGURE 5.
All Air from Outdoors
Opening Source
*D irec t t o o utd oors1 sq. in, per 4000 BTUHF igu r e 6
Ver tic al Duc t s1 sq. in, per 4000 BTUHFi gure 7
Ho r izo ntal D ucts1 sq. in, per 2000 BTUHFigu re 8A
Si ngl e O p eni ng1 sq. in, per 3000 BTUHFigu re 8B
Example: A water heater with an input rating of 50,000 BTUH using
horizontal ducts would require each opening to have a minimum free
area of 25 square inches.
Minimum free area = 50,000 BTUH x 1 sq. in. / 2000 BTUH = 25 sq. in.
These openings connect directly with the outdoors through
*
a ventilated attic, a ventilated crawl space, or through an
Minimum Free Area
Per Open i n g (sq. i n .)Refe rence Dr a wing
outside wall.
Outdoor fresh air can be provided to a confined area either
directly or by the use of vertical and horizontal ducts. The
Consult the local codes of your area for specific ventilation
and combustion air requirements.
12
GABLE VENT
TO OUTDOORS
INSTALL ABOVE
INSULATION
CONFINED
SPACE
ALTERNATE
AIR INLET
1 SQ. INCH PER
4000 BTUH
ALL AIR FROM OUTDOORS: INLET AIR FROM VENTILATED
CRAWL SPACE/OUTLET AIR TO VENTILATED ATTIC
OUTLET
AIR TO
ATTIC 1 SQ.
INCH PER
4000 BTUH
INLET AIR FROM
THE CRAWL SPACE
OPEN
FOUNDATION
VENT
FIGURE 6.
GABLE VENT
TO OUTDOORS
INSTALL ABOVE
INSULATION
OUTLET AIR
CONFINED
SPACE
ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
TO ATTIC
1 SQ. INCH
PER 4000
BTUH
INLET AIR DUCT
1 SQ. INCH PER
4000 BTUH
12” MAXIMUM
FIGURE 7.
1 SQ. INCH PER
2000 BTUH
CONFINED
SPACE
OUTLET
INLET
OUTDOOR
AIR DUCTS
ALTERNATIVE
OPENING
LOCATION
CONFINED
SPACE
ALL AIR FROM OUTDOORS - USING A SINGLE PERMANENT OPENING
1 SQ. INCH
PER 3000 BTUH
FIGURE 8B.
Vent Pipe System
This water heater uses a non-direct, single-pipe vent
system to remove exhaust gases created by the burning of
fossil fuels. Air for combustion is taken from the immediate
water heater location or is ducted in from the outside (see
“Combustion Air and Ventilation”).
This water heater must be properly vented for the removal
of exhaust gases to the outside atmosphere. Correct
installation of the vent pipe system is mandatory for the
proper and efficient operation of this water heater and is
an important factor in the life of the unit.
The vent pipe must be installed according to all local and
state codes or, in the absence of local and state codes, the
“National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current
edition. The vent pipe installation must not be obstructed
so as to prevent the removal of exhaust gases to the
outside atmosphere.
IMPORTANT: The use of vent dampers is not
recommended by the manufacturer of this water heater.
Although some vent dampers are certified by CSA
International, this certification applies to the vent damper
device only and does not mean they are certified for use
on this water heater.
U.L. recognized fuel gas and carbon monoxide (CO)
detectors are recommended in all applications and should
be installed using the manufacturer’s instructions and local
codes, rules, or regulations.
IMPORTANT: If you lack the necessary skills required
to properly install this venting system, you should not
proceed, but get help from a qualified technician.
Draft Hood Installation
SHEET METAL SCREWS (FOUR PROVIDED)
LEGS
DRAFT HOOD
1 SQ. INCH PER
2000 BTUH
ALL AIR FROM OUTDOORS USING HORIZONTAL DUCTS
FIGURE 8A .
13
SLOT
JACKET TOP
INSTALL THE DRAFT HOOD WITH
THE FOUR SCREWS PROVIDED.
FIGURE 9
LEGS
SLOT
Align the legs of the draft hood with the slots provided.
Insert the legs and secure the draft hood to the water
heater’s top with the four screws provided as shown in
Figure 9. Do not alter the draft hood in any way. If you are
replacing an existing water heater, be sure to use the draft
hood supplied with this water heater.
Vent Pipe Size
It is important that you follow the guidelines in these
instructions for sizing a vent pipe system. If a transition
to a larger vent size is required, the vent transition
connection must be made at the draft hood outlet.
Vent Connectors
1. Type B, Double wall, U.L. Listed Vent Pipe.
2. Single wall Vent Pipe.
Maintain the manufacturer’s specified minimum clearance
from combustible materials when using type B double wall
vent pipe.
Vent connectors made of type B, double wall vent pipe
material may pass through walls or partitions constructed
of combustible material if the minimum listed clearance is
maintained.
Maintain a six inch minimum clearance from all
combustible materials when using single wall vent pipe.
IMPORTANT: Single wall vent pipe cannot be used for
water heaters located in attics and may not pass through
attic spaces, crawl spaces or any confined or inaccessible
location. A single wall metal vent connector cannot pass
through any interior wall.
When installing a vent connector, please note the following
(See Figures 10-12):
• Install the vent connector avoiding unnecessary bends,
which create resistance to the flow of vent gases.
• Install without dips or sags with an upward slope of at
least 1/4-inch per foot.
• Joints must be fastened by sheet metal screws or other
approved means. It must be supported to maintain
clearances and prevent separation of joints and
damage.
• The length of the vent connector cannot exceed 75% of
the vertical vent height.
• The vent connector must be accessible for cleaning,
inspection, and replacement.
• Vent connectors cannot pass through any ceiling, floor,
firewall, or fire partition.
• It is recommended (but not mandatory) that a minimum
12 inches of vertical vent pipe be installed on the draft
hood prior to any elbow in the vent system.
IMPORTANT: Existing vent systems must be inspected for
obstructions, corrosion, and proper installation.
Chimney Connection
IMPORTANT: Before connecting a vent to a chimney,
make sure the chimney passageway is clear and free of
obstructions. The chimney must be cleaned if previously
used for venting solid fuel appliances or fireplaces. Also
consult local and state codes for proper chimney sizing
and application or, in the absence of local and state
codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition.
• The connector must be installed above the extreme
bottom of the chimney to prevent potentially blocking
the flue gases.
• The connector must be firmly attached and sealed to
prevent it from falling out.
• To aid in removing the connector, a thimble or slip joint
may be used.
• The connector must not extend beyond the inner edge
of the chimney as it may restrict the space between it
and the opposite wall of the chimney (Figure 10).
LISTED LINED
CHIMNEY
2 FT. MINIMUM ABOVE ANY OBJECT
WITHIN 10FT. HORIZONTALLY
DO NOT EXTEND
VENT BEYOND EDGE
OF CHIMNEY
VENT
CONNECTOR
SUPPORT
STRAP
MAINTAIN
CLEARANCE*
3 FT. MINIMUM
SEAL
SLOPE
UP 1/4 IN.
PER FT.
MINIMUM
CHIMNEY TERMINATION VENT SYSTEM
FIGURE 10.
Do not terminate the vent connector in a chimney that has
not been certified for this purpose. Some local codes may
prohibit the termination of vent connectors in a masonry
chimney.
Vertical Exhaust Gas Vent
Vertical exhaust gas vents must be installed with
U.L. listed type B vent pipe according to the vent
manufacturer’s instructions and the terms of its listing.
It must be connected to the water heater’s draft hood by a
listed vent connector or by directly originating at the draft
hood opening.
Vertical gas vents must terminate with a listed cap or
other roof assembly and be installed according to their
manufacturer’s instructions.
Gas vents must be supported to prevent damage, joint
separation, and maintain clearances to combustible
materials (Figures 11 and 12).
IMPORTANT: This gas vent must be terminated in a
vertical position to facilitate the removal of the burnt gases.
An unused chimney flue or masonry enclosure may be used
as a passageway for the installation of a gas vent (Figure 12).
Common (combined) venting is allowable with vertical type
B vent systems and lined masonry chimneys as long as
proper draft for the water heater is established under all
conditions of operation. CAUTION: DO NOT common vent
this water heater with any power vented appliance.
Figures 10-12 are examples of vent pipe system
installations and may or may not be typical for your
specific application. Consult the “National Fuel Gas Code”,
NFPA 54, ANSI Z223.1-current edition and the guidelines
set forth by prevailing local codes.
14
LISTED VENT CAP
WATER SYSTEM PIPING
2 FT. MINIMUM ABOVE ANY OBJECT
3 FT. MINIMUM
SUPPORT
STRAP
*MAINTAIN
CLEARANCE
VENT
CONNECTOR
SLOPE UP
1/4 IN. PER FT.
MINIMUM
VERTICAL GAS VENT SYSTEM WITH
TYPE B DOUBLE WALL VENT PIPE.
Maintain vent pipe clearance requirements to local, state
*
SEAL
VENTING THROUGH A CHIMNEY WITH
TYPE B DOUBLE WALL VENT PIPE.
FIGURE 12.
WITHIN 10 FT. HORIZONTALLY
TYPE B DOUBLE
WALL VENT PIPE
**MAINTAIN
SPECIFIED
CLEARANCE
LISTED VENT CAP
**MAINTAIN
SPECIFIED
CLEARANCE
VENT CONNECTOR
UNUSED CHIMNEY
FLUE OR MASONRY
ENCLOSURE
and/or the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition.
NFPA 211, Standard for Chimneys, Fireplaces, Vents, and
**
Solid Fuel-Burning Appliances states that these chimneys are
intended to be installed in accordance with the installation
instructions provided with each chimney support assembly.
Minimum air space clearance to combustible materials should be
maintained as marked on the chimney sections.
Piping Installation
Piping, fittings, and valves should be installed according
to the installation drawing (Figure 13). If the indoor
installation area is subject to freezing temperatures, the
water piping must be protected by insulation.
The water supply pressure should not exceed 80 psi. If
this occurs, a pressure reducing valve with a bypass may
need to be installed in the cold water inlet line. This should
be placed on the supply to the entire house in order to
maintain equal hot and cold water pressures.
IMPORTANT: Heat cannot be applied to the water fittings
on the heater as they may contain nonmetallic parts. If
solder connections are used, solder the pipe to the adapter
before attaching the adapter to the hot and cold water
fittings.
IMPORTANT: Always use a good grade of joint compound
and be certain that all fittings are drawn up tight.
1. Install the water piping and fittings as shown in Figure
13. Connect the cold water supply (3/4” NPT) to the
cold water inlet fitting. Connect the hot water supply
(3/4” NPT) to the hot water outlet fitting.
IMPORTANT: Some models may contain energy saving
heat traps to prevent the circulation of hot water within the
pipes. Do not remove the inserts within the heat traps.
2. The installation of unions in both the hot and cold water
supply lines is recommended for ease of removing the
water heater for service or replacement.
3. The manufacturer of this water heater recommends
installing a mixing valve or an anti-scald device in the
domestic hot water line as shown in Figure 14. These
valves reduce the point-of-use temperature of the
water by mixing cold and hot water and are readily
available for use.
4. If installing the water heater in a closed water system,
install an expansion tank in the cold water line as
specified under Closed System/Thermal Expansion.
5. Install a shut-off valve in the cold water inlet line. It
should be located close to the water heater and be
easily accessible. Know the location of this valve and
how to shut off the water to the heater.
6. A temperature and pressure relief valve must be
installed in the opening marked “Temperature and
Pressure (T & P) Relief Valve” on the water heater.
A discharge line must be added to the opening of
the T&P Relief Valve. Follow the instructions under
Temperature and Pressure Relief Valve.
7. After piping has been properly connected to the water
heater, remove the aerator at the nearest hot water
faucet. Open the hot water faucet and allow the tank
to completely fill with water. To purge the lines of
any excess air, keep the hot water faucet open for
3 minutes after a constant flow of water is obtained.
Close the faucet and check all connections for leaks.
15
E
HOT WATER
OUTLET
UNION
” MINIMUM
METAL
DRAIN PAN
1 3/4” DEPTH MAXIMUM
IN A CLOSED SYSTEM, USE A
THERMAL EXPANSION TANK
COLD WATER
SUPPLY TO FIXTURES
MAIN WATER SUPPLY
COLD WATER
INLET VALVE
(SHUT-OFF VALVE)
TEMPERATURE AND PRESSURE RELIEF VALV
DISCHARGE PIPE
DO NOT CAP OR PLUG
DRAIN LINE 3/4”
ID MINIMUM
6” MAXIMUM
AIR GAP
FLOOR DRAIN
PRESSURE REDUCING
VALVE WITH BYPASS
MASSACHUSSETTS:
INSTALL A VACUUM RELIEF
IN COLD WATER LINE PER
SECTION 19 MGL 142.
Please note the following:
• The system should be installed only with piping that is
suitable for potable (drinkable) water such as copper,
CPVC, or polybutylene. This water heater must not be
installed using iron piping or PVC water piping.
• Use only pumps, valves, or fittings that are compatible
with potable water.
• It is recommend that only full flow ball or gate valves
are used in water piping installations. The use of valves
that may cause excessive restriction to water flow is not
recommended.
• Use only 95/5 tin-antimony or other equivalent solder.
Any lead based solder must not be used.
• Piping that has been treated with chromates, boiler seal,
or other chemicals must not be used.
• Chemicals that may contaminate the potable water
supply must not be added to the piping system.
UNTEMPERED
HOT WATER
HOT
WATER
OUTLET
FIGURE 13.
TEMPERED WATER
TO FIXTURES
COLD
WATER
INLET
MIXING VALVE
(SET TO 120°F)
FOLLOW THE MIXING
VALVE MANUFACTURER’S
INSTRUCTIONS
Closed System/Thermal Expansion
As water is heated, it expands (thermal expansion). In a closed
system, the volume of water will grow. As the volume of water
grows, there will be a corresponding increase in water pressure
due to thermal expansion. Thermal expansion can cause
premature tank failure (leakage). This type of failure is not
covered under the limited warranty. Thermal expansion can also
cause intermittent temperature-pressure relief valve operation:
water discharged from the valve due to excessive pressure build
up. The temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This condition is not covered
under the limited warranty.
A properly-sized thermal expansion tank should be installed on
all closed systems to control the effects of thermal expansion.
Contact a plumbing service agency or your retail supplier
regarding the installation of a thermal expansion tank.
TEMPERATURE AND PRESSURE RELIEF (T&P)
VALVE (OPTIONAL TOP T&P RELIEF
VALVE NOT SHOWN)
1” MINIMUM
METAL
DRAIN PAN
DRAIN
For protection against excessive pressures and
temperatures, a temperature and pressure relief valve must
be installed in the opening marked “T & P RELIEF VALVE”
(see Figure 15). This valve must be design certified by
a nationally recognized testing laboratory that maintains
periodic inspection of the production of listed equipment or
materials as meeting the requirements for Relief Valves for
Hot Water Supply Systems, ANSI Z21.22. The function of
the temperature and pressure relief valve is to discharge
water in large quantities in the event of excessive
temperature or pressure developing in the water heater.
The valve’s relief pressure must not exceed the working
pressure of the water heater as stated on the rating plate.
IMPORTANT: Only a new temperature and pressure relief
valve should be used with your water heater. Do not use an
old or existing valve as it may be damaged or not adequate
for the working pressure of the new water heater. Do not
place any valve between the relief valve and the tank.
The Temperature & Pressure Relief Valve:
• Must not be in contact with any electrical part.
• Must be connected to an adequate discharge line.
• Must not be rated higher than the working pressure
shown on the rating plate of the water heater.
The Discharge Line:
DISCHARGE PIPE
DO NOT CAP OR PLUG
DRAIN LINE 3/4”
ID MINIMUM
6” MAXIMUM
AIR GAP
FIGURE 15.
• Must not be smaller than the pipe size of the relief
valve or have any reducing coupling installed in the
discharge line.
• Must not be capped, blocked, plugged or contain any
valve between the relief valve and the end of the discharge line.
• Must terminate a maximum of six inches above a floor
drain or external to the building. In cold climates, it is
recommended that the discharge pipe be terminated at
an adequate drain inside the building.
• Must be capable of withstanding 250°F (121°C) without
distortion.
• Must be installed to allow complete drainage of both
the valve and discharge line.
T&P Relief Valv e and P ipe Insulation (Some Models)
1. Locate the temperature and pressure relief valve on
the water heater (also known as a T&P relief valve).
See Figure 16.
2. Locate the slit running the length of the T&P relief
valve insulation.
3. Spread the slit open and fit the insulation over the T&P
relief valve. See Figure 16. Apply gentle pressure to
the insulation to ensure that it is fully seated on the
T&P Relief Valve. Once seated, secure the insulation
with duct tape, electrical tape, or equivalent.
IMPORTANT: The insulation or tape should not block
or cover the T&P relief valve drain opening. Also,
the insulation or tape should not block or hinder
access to the manual relief lever (Figure 16). Ensure
that a discharge pipe is installed into the T&P valve
discharge opening per the instructions in this manual.
4. Locate the hot water (outlet) & cold water (inlet) pipes
to the water heater.
5. Locate the slit running the length of a section of pipe
insulation.
6. Spread the slit open and slip the insulation over the cold
water (inlet) pipe. Apply gentle pressure along the length
of the insulation to ensure that it is fully seated around
the pipe. Also, ensure that the base of the insulation is
flush with the water heater. Once seated, secure the
insulation with duct tape, electrical tape, or equivalent.
7. Repeat steps 5 and 6 for the hot water (outlet) pipe.
8. Add additional sections of pipe insulation as needed.
T&P RELIEF VALVE INSULATION
MANUAL RELIEF
LEVER
T&P RELIEF
VALVE
T&P RELIEF VALVE
DRAIN LINE
FIGURE 16.
17
IMPORTANT INFORMATION ABOUT THIS WATER HEATER
This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor
ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation
errors. Please review the following checklist and make any required installation upgrades or changes.
Questions? Contact Residential Technical Assistance by referencing the phone number on the front of the Installation
Instructions and Use & Care Guide.
Installation Checklist
Water Heater Location
Water heater location is important and can affect system
performance. Please check the following:
□ Installation area free of corrosive elements and flammable
materials.
□ Centrally located with the water piping system.
Located as close to the gas piping and vent pipe
system as possible.
□ Located indoors and in a vertical position. Protected
from freezing temperatures.
□ Proper clearances from combustible surfaces
maintained and not installed directly on a carpeted
floor.
□ Provisions made to protect the area from water
damage. Metal drain pan installed and piped to an
adequate drain.
□ Sufficient room to service the water heater. See
“Clearances and Accessibility” section of this
manual.
□ Water heater not located near an air moving device.
□ Is the installed environment dirty (excessive amounts
of lint, dirt, dust, etc.)? If so, the flame arrestor
located on the bottom of the water heater will need to
be cleaned periodically. Refer to the “Maintenance
of your Water Heater” section of this manual for
information on cleaning the flame arrestor.
Combustion Air Supply and Ventilation
Check for sufficient combustion air supply. Insufficient air
for the combustion of gas will result in the flame becoming
“lazy”, thereby allowing heat to build up in the combustion
chamber. This excessive heat will cause a thermal switch
on the door assembly to trip. Is the water heater installed in
a closet or other small, enclosed space? If so:
□ Are there openings for make-up air to enter and
exit the room/area?
□Are the openings of sufficient size? Remember,
if there are other gas-fired or air-consuming
appliances in the same room, you need more
make-up air. Refer to the “Location Requirements”
section of this water heater manual for specific
requirements.
Fresh air not taken from areas that contain negative
pressure producing devices such as exhaust fans,
fireplaces, etc.
□ Is there a furnace/air handler in the same room
space as the water heater? If so, has a return air
duct system been attached that exits the room?
If so, check for leaks on the air duct system. If no
air duct system is present, correct immediately
by contacting a local Heating, Ventilation, AirConditioning & Refrigeration (HVAC-R) authorized
service provider.
□ Fresh air supply free of corrosive elements and
flammable vapors.
□ Fresh air openings sized correctly with consideration
given to the blocking effect of louvers and grilles.
□ Ductwork is the same cross-sectional area as the
openings.
Vent Pipe System
Check for proper drafting at the water heater draft hood.
Refer to the “Checking the Draft” section of this manual for
the test procedure. If the procedure shows insufficient draft
is present, please check the following.
□ Draft hood properly installed.
□ Vent connectors securely fastened with screws and
supported properly to maintain six inch clearance.
□ Vent connector made of approved material and
sized correctly.
□ Vent pipe system installed according to all local
and state codes or, in the absence of local and
state codes, the “National Fuel Gas Code”, ANSI
Z223.1(NFPA 54)-current edition.
□ Flue baffle properly positioned in the flue tube.
□ Check the vent system for restrictions/obstructions
and check the vent termination height. Refer to the
“Air Supply and Ventilation” section of this water
heater manual for specific requirements.
□Recheck for sufficient combustion air supply.
Water System Piping
□ Temperature and pressure relief valve properly
installed with a discharge line run to an open drain
and protected from freezing.
□ All piping properly installed and free of leaks.
□ Heater completely filled with water.
□ Closed system pressure build-up devices installed.
□ Mixing valve (when applicable) installed
per manufacturer’s instructions (see “Water
Temperature Regulation” section).
Gas Supply and Piping
□ Gas type is the same as that listed on the water
heater data plate.
□ Gas line equipped with shut-off valve, union, and
sediment trap.
□ Adequate pipe size and approved pipe material.
□ An approved noncorrosive leak detection solution
used to check all connections and fittings for
possible gas leaks. If such a solution is not
available, use a mixture of dish washing soap and
water (one part soap to 15 parts water) or children’s
soap bubble solution. Bubbles forming indicate a
leak. Correct any leak found.
TEFLON ® is a registered trademark of E.I. Du Pont De Nemours and
Company.
18
OPERATING YOUR WATER HEATER
Lighting Instructions
Read and understand these directions thoroughly before
attempting to light or re-light the pilot. Make sure the view
port is not missing or damaged. (See Figure 23.) Make
sure the tank is completely filled with water before lighting
the pilot. Check the rating plate near the gas control valve/
thermostat for the correct type of gas. Do not use this
water heater with any gas other than the one listed on the
rating plate. If you have any questions or doubts, consult
your gas supplier or gas utility company.
WARNING
Explosion Hazard
Replace view port if glass is missing
or damaged.
Failure to do so can result in death,
explosion or fire.
Lighting the Pilot:
1. Read and follow the lighting instructions on the water
heater’s label.
2. Turn the Control Knob to Pilot. Press the Knob in fully
and hold it in. (The knob will travel in about 1/4-inch if
it is set to Pilot correctly.)
3. Click the Igniter button continuously for up to 90
seconds or until the Status Light begins to blink.
If the Status Light does not begin to blink after 90
seconds, STOP. Wait 10 minutes before attempting
to relight the Pilot. Repeat these steps 2-3 times, if
necessary.
The circuitry in this gas valve requires that you wait 10
minutes between lighting attempts.
If the Status Light blinks, release the Control
Knob and turn it to the desired setting. (“Hot” is
approximately 120°F).
If the Status Light Does Not Blink:
1. Wait 10 minutes before another lighting attempt.
2. If the Status Light did not blink, repeat the lighting
procedure by following the lighting instructions on
the water heater’s label. Remove the outer door.
The Control Knob must be set to Pilot and held in
continuously while clicking the igniter button (about
once per second for up to 90 seconds). To observe the
Pilot, remove the outer door and look through the view
port (sight glass). See Figure 23.
3. Continue clicking the Igniter button (for up to 90
seconds) until Pilot lights.
4. Once the Pilot is lit, continue to hold the Control Knob
in until the Status Light begins to blink.
5. Release Control Knob and set Knob to desired
temperature setting. (“Hot” is approximately 120°F.)
6. Replace the outer door.
If the Pilot Does Not Light:
1. Wait 10 minutes before another lighting attempt.
If the pilot does not light, the Igniter may not be
sparking or the unit may not be getting gas (or for a
new installation, there may still be air in the gas line).
Each time you click the igniter button, you should be
able to see the spark by looking through the view port.
See Figure 23. (You may have to darken the room
lights to see the spark.) You do not have to push the
Control Knob in to check the Igniter button. Simply
look through the sight glass while clicking the Igniter
button and look for a spark. If you can’t see a spark
when the Igniter button is clicked, check the wiring
connections from the Igniter button and make sure that
they are tight.
2. If you see the Igniter spark, try relighting the pilot by
following the instructions on the water heater’s label.
Ensure that the gas supply is tuned on. There may
be air in the gas line, and several lighting attempts
may be needed to completely fill the line with gas and
successfully light the pilot.
If the Pilot Lights but the Status Light Does Not Blink:
1. If the pilot lights, continue to hold the Control Knob
in until the Status Light blinks. If the pilot is lit and
remains lit for 90 seconds and the Status Light still
does not blink, the thermopile connections may be
loose, the thermal switch may need to be reset, or the
thermopile may be defective.
2. Remove the outer door.
3. Press the reset button on the thermal switch (Figure 23).
4. If switch clicks, it may have tripped. Do not light the
Pilot if flammable vapors are present. Check flame
arrestor for signs of discoloration (which could be
caused by flammable vapors). If the flame arrestor is
discolored, do not attempt to relight the Pilot. Have
the water heater inspected by a qualified service
technician.
5. Check the wiring connections from the thermopile and
the thermal switch to the gas control valve/thermostat.
Ensure that all wiring connections are tight. See
Figure 23.
6. Replace the outer door.
7. Wait 10 minutes and try to light the Pilot according to
the instructions on the water heater’s label.
8. While clicking the Igniter button continuously,
the Control Knob must be set to Pilot and held
in until the Status Light blinks. Once the Status
Light blinks, release the Control Knob and set the
Knob to the desired temperature setting. (“Hot” is
approximately 120°F.)
19
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, personal
injury or loss of life.
FLAMMABLE
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES
Use only your hand to push in or turn the gas control
This appliance has a pilot which is lit by a piezo-
A.
electric spark gas ignition system. Do not open
the inner door of the appliance and try to light
the pilot by hand.
BEFORE LIGHTING
B.
smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
C.
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
Do not use this appliance if any part has been under
D.
water. Immediately contact a qualified installer or
service agency to replace a flooded water heater.
Do not attempt to repair the unit! It must be replaced!
DO NOT USE THIS APPLIANCE IF THERE HAS
E.
BEEN AN IGNITION OF VAPORS. Immediately
call a qualified service technician to inspect the
appliance. Water heaters subjected to a
flammable vapors ignition will show a
discoloration on the air intake grid and require
replacement of the entire water heater.
LIGHTING INSTRUCTIONS
Gas Control/Temperature Knob
Status
Light
120°F
120°F
Mark
Mark
FIGURE 'A'
FIGURE 'B'
120°F
120°F
Mark
Mark
FIGURE 'C'
120°F
120°F
Mark
Mark
MAIN BURNER
THERMOPILE
VAC
Igniter
GAS CONTROL
"OFF" POSITION
"PILOT" POSITION
CONTROL KNOB
1. STOP! It is imperative that you read all safety
warnings before lighting the pilot.
2. Turn the gas control/temperature knob
counterclockwise to the "OFF" setting.
3. Wait ten (10) minutes to clear out any gas. If you then
smell gas, STOP! Follow “ B” in the safety
information above on this label. If you do not
smell gas, go to the next step.
4. Turn the gas control/temperature knob clockwise to
“ PILOT”. See Figure ‘B’.
5. Press the gas control/temperature knob all the way
in and hold it in. The knob should travel in about
1/4 inch (6.35 mm) if it is set to "PILOT" correctly.
While holding the gas control/temperature knob in,
click the igniter button continuously (about once a
second) for up to 90 seconds or until Status Light
begins to blink.
6. When the status light starts blinking, release the
gas control/temperature knob. Set the gas control/
TO TURN OFF GAS TO APPLIANCE
"ON" POSITION
PILOT
FIGURE 'D'
temperature knob to the desired setting. See Figure ‘C’.
If the status light does not start blinking within 90
seconds, repeat steps 2 through 5 up to THREE (3)
times, waiting 10 minutes between lighting attempts.
The circuitry in this advanced gas valve requires
that you wait 10 minutes between lighting attempts.
If the status light turns a solid color, release the gas
control/temperature knob and repeat steps 2 through 5
(waiting 10 minutes before attempting to relight the pilot).
If the status light does not start blinking after three
lighting attempts, turn the gas control/temperature knob
to "OFF" and call a qualified service technician or your
gas supplier.
DANGER: Hotter water increases the risk of scald
injury. Consult the instruction manual before
changing temperature.
Refer to the Lighting Instructions in the Installation
Manual for more detailed troubleshooting
information.
1. Turn the gas control/temperature knob counterclockwise to the "OFF" setting. The status light will stop blinking and stay
on for a short time after the water heater is turned off. See Figure ‘A’.
20
Checking the Draft
G
Water Temperature Regulation
WARNING
Burn Hazard
Do not touch vent.
Doing so can result in burns.
After successfully lighting the water heater, allow the unit to
operate for 15 minutes and check the draft hood relief
opening for proper draft (Figure 17). Make sure all other
appliances in the area are operating and all doors are closed
when performing the draft test. Pass a match flame around
the relief opening of the draft hood. A steady flame drawn
into the opening indicates proper draft.
DRAFT HOOD
RELIEF
OPENIN
ATCH
FIGURE 17.
If the flame flutters or is blown out, combustion products are
escaping from the relief opening. If this occurs, do not operate
the water heater until proper adjustments or repairs are made
to the vent pipe system and/or air supply requirements.
Burner Flames
Inspect the burner flames through the viewport and
compare them to the drawings in Figure 18. A properly
operating burner should produce a soft blue flame. Blue
tips with yellow inner cones are satisfactory. The tips
of the flame may have a slight yellow tint. The flame
should not be all yellow or have a sharp blue-orange
color. Contaminated air may cause an orange colored
flame. Contact a qualified technician if the flame is not
satisfactory.
FIGURE 18.
Emergency Shut Down
IMPORTANT: Should overheating occur or the gas supply
fails to shut off, turn off the water heater’s manual gas
control valve and call a qualified technician.
Water temperature over 125°F (52°C)
can cause servere burns instantly
resulting in severe injury or death.
Children, the elderly, and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting valves are
available.
Read instruction manual for safe
temperature setting.
Due to the nature of the typical gas water heater, the water
temperature in certain situations may vary up to 30°F
(16.7 °C) higher or lower at the point of use such as,
bathtubs, showers, sink, etc.
HOTTER WATER CAN SCALD: Water heaters are
intended to produce hot water. Water heated to a
temperature which will satisfy space heating, clothes
washing, dish washing, and other sanitizing needs can
scald and permanently injure you upon contact. Some
people are more likely to be permanently injured by hot
water than others. These include the elderly, children,
the infirm, or physically/mentally handicapped. If anyone
using hot water in your home fits into one of these groups
or if there is a local code or state law requiring a certain
temperature water at the hot water tap, then you must
take special precautions. In addition to using the lowest
possible temperature setting that satisfies your hot water
needs, a means such as a mixing valve should be used
at the hot water taps used by these people or at the water
heater. Mixing valves are available at plumbing supply or
hardware stores. See Figure 14. Follow manufacturer’s
instructions for installation of the valves. Before changing
the factory setting on the thermostat, see Figure 19A.
Using the lowest hot water temperature that meets your
needs will also provide the most energy efficient operation
of the water heater.
Never allow small children to use a hot water tap, or
to draw their own bath water. Never leave a child or
handicapped person unattended in a bathtub or shower.
NOTE: A water temperature range of 120°F-140°F
(49°C-60°C) is recommended by most dishwasher
manufacturers.
The thermostat is adjusted to the pilot position when it
is shipped from the factory. Water temperature can be
regulated by moving the temperature dial to the preferred
setting. The preferred starting point is 120°F at the “HOT”
setting. Align the knob with the desired water temperature
as shown in Figure 19A. There is a hot water scald
potential if the thermostat is set too high.
NOTE: Temperatures shown on the gas control valve/
thermostat are approximates. The actual temperature of
the heated water may vary.
IMPORTANT: Adjusting the thermostat past the 120°F
mark on the temperature dial will increase the risk of scald
injury. Hot water can produce first degree burns within:
21
Water
Temperature °F
110
116
116
122
131
140
149
154
(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)
GAS CONTROL VALVE/THERMOSTAT
SETTINGS
GAS CONTROL/TEMPERATURE KNOB
Time for 1st
Degree Burn
(Less Severe Burns)
(normal shower temp.)
(pain threshold)
35 minutes
1 minute
5 seconds
2 seconds
1 second
Instantaneous
STATUS
LIGHT
120°F
MARK
Time for
Permanent Burns
2nd & 3rd Degree
(Most Severe Burns)
45 minutes
5 minutes
25 seconds
5 seconds
2 seconds
1 second
Water Temperature Adjustment
The water temperature setting can be adjusted from 55°F
to 155°F. Turn the Gas Control/Temperature Knob to the
desired setting/temperature.
NOTE:
• Some models are certified for 180°F outlet
temperatures. See the Data Plate on the front of the
water heater for the maximum outlet temperature.
• The temperatures indicated are approximates. The
actual temperature of the heated water may vary.
Operating Modes and Settings
• Standard Mode - The controller adjusts the water
heater to maintain the temperature set by the user.
• Vacation Setting - The Vacation setting (VAC) sets
the controller at approximately 55°F. This setting is
recommended when the water heater is not in use for a
long period of time. This effectively turns the controller
temperature setting down to a temperature that
prevents the water in the water heater from freezing
while still conserving energy.
VAC
IGNITER
FIGURE 19A.
Should overheating occur or the gas supply fail to shut off,
turn off the manual gas control valve to the appliance.
NOTE: During low demand periods when hot water is not
being used, a lower thermostat setting will reduce energy
losses and may satisfy your normal hot water needs. If hot
water use is expected to be more than normal, a higher
thermostat setting may be required to meet the increased
demand. When leaving your home for extended periods
(vacations, etc.) turn the temperature dial to its lowest
setting. This will maintain the water at low temperatures
with minimum energy losses and prevent the tank from
freezing during cold weather.
Operating the Temperature Control System
List of status codes are shown
at top of gas control valve/thermostat.
VAC
FIGURE 19B.
Status Light Code
Normal Flashes:
• 0 Flashes Indicates Control Off/Pilot Out.
• 1 Flash Indicates Normal Operation.
• A solid light indicates that the gas control
valve/thermostat is shutting down.
Diagnostic Flashes:
If the water heater is not working, look for the following
diagnostic flashes after lighting the pilot. For more details, see
“
Status Light and Diagnostic Code Troubleshooting Chart
2 Flashes Indicates Thermopile Voltage Low
4 Flashes Indicates Overheat Failure
5 Flashes Indicates Sensor Failure
7 Flashes Indicates Electronic Control Failure
8 Flashes See “Status Light and Diagnostic Code
Troubleshooting Chart.”
Operational Conditions
Condensation
Whenever the water heater is filled with cold water, some
condensate will form while the burner is on. A water
heater may appear to be leaking when in fact the water is
condensation. This usually happens when:
a. A new water heater is filled with cold water for the first time.
b. Burning gas produces water vapor in water heaters, par-
ticularly high efficiency models where flue temperatures
are lower.
c. Large amounts of hot water are used in a short time and
the refill water in the tank is very cold.
Moisture from the products of combustion condense on the
cooler tank surfaces and form drops of water which may fall
onto the burner or other hot surfaces to produce a “sizzling”
or “frying” noise.
22
.”
Excessive condensation can cause pilot outage due to
water running down the flue tube onto the main burner and
putting out the pilot.
Because of the suddenness and amount of water,
condensation water may be diagnosed as a “tank leak”.
After the water in the tank warms up (about 1-2 hours), the
condition should disappear.
Do not assume the water heater is leaking until there has
been enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation.
The water heater must be sized properly to meet the
family’s
machines and shower heads.
Excessive condensation may be noticed during the winter and
early spring months when incoming water temperatures are at
their lowest.
Good venting is essential for a gas fired water heater to operate
properly as well as to carry away products of combustion and
water vapor.
demands for hot water including dishwashers, washing
It is always recommended that a suitable metal drain pan
be installed under the water heater to protect the area
from water damage resulting from normal condensation
production, a leaking tank or piping connections. Refer to
the “Location Requirements” section.
Water Heater Sounds
During the normal operation of the water heater, sounds or
noises may be heard. These noises are common and may
result from the following:
1. Normal expansion and contraction of metal parts
during periods of heat-up and cool-down.
2. Condensation causes sizzling and popping within the
burner area and should be considered normal.
3. Sediment buildup in the tank bottom will create varying
amounts of noise and may cause premature tank
failure. Drain and flush the tank as directed under the
“Draining and Flushing” section.
Smoke/Odor
The water heater may give off a small amount of smoke
and odor during the initial start-up of the unit. This is due
to the burning off of oil from metal parts of a new unit and
will disappear after a brief period of operation.
Safety Shut-off
This water heater is designed to automatically shut-off in
the event of the following:
1. The pilot flame is extinguished for any reason.
2. The water temperature exceeds 189°F (87°C) for
155°F models or 199°F (93°C) for 180°F models. See
the data plate for your model.
3. Excessive combustion chamber temperatures.
4. The ignition of flammable vapors.
A thermopile is used to determine if a pilot flame is
present, and will shut off the gas supply to the main
burner and the pilot if the flame is absent. This unit is
also equipped with a thermal switch, designed to shut off
the gas supply in the event the heater has been exposed
to flammable vapors (spilled gasoline or paint fumes,
for example), poor combustion caused by insufficient
combustion air, or improper venting. If the switch opens,
check the flame arrestor for signs of high temperature
(blue or black discoloration), and inspect your installation
for any problems with venting or combustion air. (See
Pilot Light Troubleshooting Flowchart). Reset the switch
by depressing the small button in the center of the switch.
IMPORTANT: Correct any issues prior to resetting the
switch. Reference the number on the cover of this manual
for service information.
The gas control valve\thermostat includes a temperature
limiting ECO (Energy Cut Off) system that will shut off
the water heater if the water temperature exceeds 189°F
(87°C) for 155°F models or 199°F (93°C) for 180°F
models. See the data plate for your model.
Should the water temperature get too high, the diagnostic
status light will flash a code (4 flashes), indicating an overtemperature condition and the main burner will be shut
off. If a high temperature condition occurs, turn the main
gas supply OFF and have the water heater repaired by a
qualified service technician. Contact your local dealer for
service information.
Anode Rod/Water Odor
Each water heater contains at least one anode rod,
which will slowly deplete (due to electrolysis) prolonging
the life of the water heater by protecting the glass-lined
tank from corrosion. Adverse water quality, hotter water
temperatures, high hot water usage, hydronic heating
devices, and water softening methods can increase
the rate of anode rod depletion. Once the anode rod
is depleted, the tank will start to corrode, eventually
developing a leak.
Certain water conditions will cause a reaction between the
anode rod and the water. The most common complaint
associated with the anode rod is a “rotten egg smell”
produced from the presence of hydrogen sulfide gas
dissolved in the water.
IMPORTANT: Do not remove this rod permanently as it will
void any warranties. A special anode rod may be available
if water odor or discoloration occurs.
NOTE: This rod may reduce but not eliminate water odor
problems. The water supply system may require special
filtration equipment from a water conditioning company to
successfully eliminate all water odor problems.
Artificially softened water is exceedingly corrosive because
the process substitutes sodium ions for magnesium and
calcium ions. The use of a water softener may decrease
the life of the water heater tank.
The anode rod should be inspected after a maximum of
three years and annually thereafter until the condition of
the anode rod dictates its replacement.
NOTE: Artificially softened water requires the anode rod to
be inspected annually.
23
The following are typical (but not all) signs of a depleted
anode rod:
• The majority of the rods diameter is less than 3/8”.
• Significant sections of the support wire (approx. 1/3 or
more of the anode rod’s length) are visible.
If the anode rod show signs
of either or both it should be
replaced. NOTE: Whether
EXPOSED
SUPPORT
WIRE
re-installing or replacing the
anode rod, check for any leaks
and immediately correct if
found.
In replacing the anode:
1. Turn off gas supply to the
PITTED
ANODE
ROD
water heater.
2. Shut off the water supply
and open a nearby hot
water faucet to depressurize
the water tank.
3. Drain approximately 5
gallons of water from
tank. (Refer to “Draining
and Flushing” for proper
EXPOSED
SUPPORT
WIRE
FIGURE 20.
procedures). Close drain
valve.
4. Remove the old anode rod.
5. Use Teflon® tape or approved pipe sealant on threads
and install new anode rod.
6. Turn on water supply and open a nearby hot water
faucet to purge air from water system.
7. Check for any leaks and immediately correct any if found.
8. Restart the water heater as directed in this manual. See
the Repair Parts Illustration for anode rod location.
TEFLON ® is a registered trademark of E.I. Du Pont De Nemours and Company.
Draining and Flushing
3. Close the cold water inlet valve.
4. Connect a hose to the drain valve and terminate it to
an adequate drain or external to the building.
5. Open the water heater drain valve and allow all of the
water to drain from the tank. Flush the tank with water
as needed to remove sediment.
6. Close the drain valve, refill the tank, and restart the
water heater as directed in this manual.
If the water heater is going to be shut down for an
extended period, the drain valve should be left open.
IMPORTANT: Condensation may occur when refilling the
tank and should not be confused with a tank leak.
Routine Preventive Maintenance
At least annually, a visual inspection should be made of
the venting and air supply system, piping systems, main
burner, pilot burner, and flame-arrestor. Check the water
heater for the following:
• Obstructions, damage, or deterioration in the venting
system. Make sure the ventilation and combustion air
supplies are not obstructed.
• Clean any dust or debris from the base-ring filter.
• Soot and/or carbon on the main burner and pilot
burner. Contact a qualified technician.
• Leaking or damaged water and gas piping.
• Presence of flammable or corrosive materials in the
installation area.
• Presence of combustible materials near the water
heater.
• After servicing this water heater, check to make sure
it is working properly. (See “Operating Your Water
Heater” section of this manual.)
IMPORTANT: If you lack the necessary skills required to
properly perform this visual inspection, you should not
proceed, but get help from a qualified technician.
It is recommended that the tank be drained and flushed
every 6 months to remove sediment which may build up
during operation. The water heater should be drained if
being shut down during freezing temperatures. To drain the
tank, perform the following steps:
1. Turn off the gas to the water heater at the manual gas
shut-off valve.
2. Open a nearby hot water faucet until the water is no
longer hot.
T emperature and Pressure Relief Valve
Explosion Harzard
• Temperature-pressure relief
valve must comply with ANSI
Z21.22-CSA 4.4 and ASME
code.
• Properly sized temperaturepressure relief valve must be
installed in opening provided.
• Can result in overheating
and excessive tank pressure.
• Can cause serious injury or
death.
Manually operate the temperature and pressure relief
valve at least once a year to make sure that it is working
24
properly. To prevent water damage, the valve must be
properly connected to a discharge line which terminates at
an adequate drain. Standing clear of the outlet (discharged
water may be hot), slowly lift and release the lever handle
on the temperature and pressure relief valve to allow the
valve to operate freely and return to its closed position.
See Figure 21. If the valve fails to completely reset and
continues to release water, immediately shut off the
manual gas control valve and the cold water inlet valve
and call a qualified technician.
MAINTENANCE OF YOUR WATER HEATER
TEMPERATURE AND PRESSURE
RELIEF VALVE
DISCHARGE LINE TO DRAIN
MANUAL RELIEF
VALVE
FIGURE 21.
Replacement Parts
IMPORTANT: The following maintenance procedures are
for the FVIR System components and should be performed
by a qualified technician.
Replacement parts may be ordered through your plumber
or the local distributor. Parts will be shipped at prevailing
prices and billed accordingly. When ordering replacement
parts, always have the following information ready:
1. model, serial, and product number
2. type of gas
3. item number
4. parts description
See Repair Parts Section for a list of available repair parts.
Removing the Manifold/Burner Assembly
1. Turn the gas control/temperature knob to the “OFF”
position (Figure 22).
2. Before performing any maintenance, it is important to turn
off the gas supply to the water heater at the manual gas
shut-off valve. This valve is typically located beside the
water heater. Note the position of the shut-off valve in the
open/on position, then proceed to turn it off (Figure 3).
3. With the unit shut-off, allow sufficient time for the water
heater to cool before performing any maintenance.
GAS CONTROL/
TEMPERATURE KNOB
VAC
IGNITER
BUTTON
IGNITER
LEAD
WIRE
IGNITER
WIRE
PILOT
TUBE
FIGURE 2 2 .
4. Remove the outer door.
5. Disconnect the following from the gas control valve/
thermostat: pilot tube (7/16” wrench), igniter wire (from the
igniter lead wire), and manifold tube (3/4” wrench). See
Figure 22.
NOTE: L.P. Gas systems use reverse (left-hand) threads
on the manifold tube.
WHITE
WIRE
(RIGHT
SIDE)
RED WIRE
(LEFT SIDE)
MANIFOLD TUBE
6. Use needle nose pliers to disconnect the white (-)
thermopile wire from the gas control valve/thermostat
(Figure 22). Next, disconnect both red thermal switch
wires from the thermal switch on the manifold door
(Figure 23).
7. Grasp the manifold tube and push down slightly to free
the manifold tube and pilot tube.
8. Remove the screws (1/4” nut driver) securing the
manifold/burner assembly to the combustion chamber.
See Figure 23.
9. Carefully remove the manifold/burner assembly from
the combustion chamber. BE SURE NOT TO DAMAGE
ANY INTERNAL PARTS.
GAS CONTROL VALVE/THERMOSTAT
GAS CONTROL/
TEMPERATURE KNOB
PIEZO IGNITER BUTTON
PILOT TUBE
VIEWPORT
OUTER DOOR
NOT SHOWN
MANIFOLD SCREW (2)
VAC
MANIFOLD COMPONENT BLOCK
FIGURE 23 .
THERMOPILE AND
SWITCH WIRE
CONNECTIONS
MANIFOLD TUBE
THERMAL SWITCH
MANIFOLD DOOR
Removing the Burner from the Manifold/
Burner Assembly
Natural Gas (Low Nox) & L.P. Gas Burner
1. Take off the burner by removing the two (2) screws
located underneath the burner.
2. Check the burner to see if it is dirty or clogged. The burner
may be cleaned with soap and hot water (Figure 24).
IMPORTANT: DO NOT remove the orifice.
PILOT ASSEMBLY
(BOTTOM VIEW)
SCREWS
BURNER
(BOTTOM VIEW)
FIGURE 24.
25
Replacing the Pilot/ Thermopile Assembly
1. Remove the manifold door assembly as described in
“Removing the Manifold/Burner Assembly” section.
2. Remove the burner to access the pilot/thermopile
assembly. Remove and keep the screws securing the
burner to the manifold (Figure 24).
IMPORTANT: DO NOT remove the orifice.
3. Remove the screw securing the pilot/thermopile assembly
to the pilot bracket and keep for reuse later (Figure 25).
4. Lift the retainer clip straight up from the back of
the manifold component block (using a flat-blade
screwdriver), then remove the manifold component
block from the manifold door (Figure 25). IMPORTANT:
Be careful not to bend or alter the position of the pilot
tube. It will be used as a bending template for the new
pilot assembly. Note the placement/order of the wires in
the manifold component block.
5. Lift the pilot/thermopile assembly (including the igniter
wire) from the manifold assembly.
7. Route the new pilot tube, igniter wire and thermopile wire
through the opening in the manifold door. See Figure 25.
8. Using the pilot screw removed earlier, attach the new
pilot/thermopile assembly. Reattach the burner to the
manifold using the screws removed earlier. NOTE: Make
sure the burner scoop is oriented to the pilot side of the
manifold tube (Figure 24).
9. Reinstall the manifold component block in the manifold
door. Ensure that the pilot tube and wires are positioned
as shown in Figure 27.
RED (+) THERMAL SWITCH WIRE
CONNECTS TO THE GAS CONTROL
VALVE\THERMOSTAT.
WHITE (-) THERMOPILE WIRE
CONNECTS TO THE GAS
CONTROL VALVE\THERMOSTAT.
MANIFOLD
COMPONENT
BLOCK
RED THERMAL SWITCH WIRE
CONNECTIONS AT MANIFOLD DOOR
PILOT / THERMOPILE
ASSEMBLY SCREW
BURNER AND OTHER
FITTINGS NOT SHOW
FOR CLARITY.
RED WIRES TO
THERMAL SWITCH (2)
IGNITER
WIRE
MANIFOLD COMPONENT
BLOCK
CONNECTORS
PILOT TUBE
MANIFOLD DOOR
RETAINER
CLIP
FIGURE 25.
6. Read this step carefully before proceeding. Using the
old pilot/pilot tube assembly as a guide, bend the new
pilot tube to match the old one. Make only the bends
closest to the pilot before going to the next step.
THERMOPILE
PILOT/THERMOPILE
ASSEMBLY
THERMAL
SWITCH
CONNECTORS
(RED WIRES)
IGNITER
CONNECTOR
PILOT
CONNECTORS
(CONNECT AT
GAS CONTROL VALVE/
THERMOSTAT)
THERMOPILE WIRES
PASS THROUGH TOP
HOLE OF THE MANIFOLD
COMPONENT BLOCK
IGNITER WIRE PASSES
THROUGH CENTER OF
MANIFOLD COMPONENT
BLOCK (SMALLEST HOLE)
PILOT TUBE PASSES
THROUGH BOTTOM HOLE
OF MANIFOLD COMPONENT
BLOCK (LARGEST HOLE)
FIGURE 27.
10. Carefully bend the new pilot tube to match the bend of
the manifold tube. NOTE: When bending, DO NOT crimp
or crease the pilot tube.
11. Before you proceed to the next step, install the new
brass ferrule nut in the gas control valve/thermostat’s
pilot tube opening, HAND TIGHT ONLY.
12. Install the manifold/burner assembly. Refer to the
“Replacing the Manifold/Burner Assembly” section for
instructions.
FIGURE 26.
FOR CLARITY, PILOT
TUBE NOT SHOWN .
26
External Inspection & Cleaning of the
Base-Ring Filter
Replacing the Manifold/Burner Assembly
1. At least once annually, check the base-ring filter
(Figure 28) for any dust or debris that may have
accumulated on the filter screen. NOTE: If the water
heater is located in an area that is subjected to lint and
dirt, it may be necessary to check the base-ring filter
more frequently.
2. Follow the Lighting Instructions to turn off the water
heater and allow it to cool for 10 minutes before
attempting to clean the base-ring filter.
3. Use a vacuum cleaner with a hose attachment to
remove any dust or debris that may have accumulated
on the filter. NOTE: If unable to inspect or clean the
base-ring filter, follow the “Cleaning the Combustion
Chamber and Flame-arrestor” instructions.
4. After the base-ring filter has been cleaned, follow
the Lighting Instructions to return the water heater to
service.
Cleaning the Combustion Chamber and
Flame-arrestor
1. Follow procedure outlined in “Removing the Manifold/
Burner Assembly”.
2. Use a vacuum cleaner/shop vac to remove all loose
debris in the combustion chamber (Figure 28). Use
compressed air to clear any dust or debris that may
have accumulated in the flame-arrestor.
COMBUSTION CHAMBER
DOOR GASKET
BASE-RING
FILTER
3. Reassemble following the procedure under “Replacing
the Manifold/Burner Assembly”.
FLAME ARRESTOR
FIGURE 28.
WARNING
Explosion Hazard
• Tighten both manifold door screws securely.
• Remove any fiberglass between gasket and
combustion chamber.
• Replace viewport if glass is missing or damaged.
Replace manifold component block if missing or
•
removed.
• Replace door gasket if damaged.
• Failure to follow these instructions can result in
death, explosion, or fire.
1. Check the door gasket for damage or imbedded debris
prior to installation (Figure 28).
2. Inspect the viewport for damage and replace as
required (Figure 23).
3. Insert the new manifold/burner assembly into the
burner compartment, making sure that the tab of the
manifold tube engages the slot of the bracket inside
t h e c o m b u s t i o n c h a m b e r ( F i g u r e 2 9 ) .
4. Inspect the door gasket and make sure there is no
fiberglass insulation between the gasket and the
combustion chamber (Figure 28).
5. Tighten the two screws that secure the manifold/burner
assembly to the combustion chamber. (Use a 1/4” nut
driver.) There should be no space between the gasket
part of the manifold door and combustion chamber
IMPORTANT: Do not operate the water heater if
the door gasket does not create a seal between the
manifold door and the combustion chamber.
6. Reconnect the manifold tube (3/4” wrench) and pilot
tube (7/16” wrench) to the gas control valve/thermostat
(Figure 22). Do not cross-thread or apply any thread
sealant to the fittings.
IMPORTANT: If you were supplied with a new ferrule
nut in a parts kit, follow these steps to connect the
pilot tube:
1.) Install the ferrule nut into the gas valve at the pilot
tube location, hand tight only. 2.) Insert the pilot tube
into the ferrule nut until the tube bottoms out, then
tighten the nut with a 7/16” wrench until the crimp
connection seals to the pilot tube. 3.) Continue to
tighten until the nut is tight in the gas valve.
NOTE: L.P. Gas systems use reverse (left-hand) threads
on the manifold tube.
27
7. Connect the white (-) thermopile wire to the gas control
valve/thermostat, then connect the red thermal switch
wires to the thermal switch on the manifold door.
(Figure 23).
8. Reconnect the igniter wire (Figure 22).
9. Turn on the gas supply to the water heater at the manual
gas shut-off valve (Figure 3).
10. Follow the lighting instructions on the front of the water
heater. With the main burner lit, check for leaks at
the manifold and pilot connections by brushing on an
approved noncorrosive leak detection solution. If such
a solution is not available, use a mixture of hand dish
washing soap and water (one part soap to 15 parts
water) or childrens’ soap bubble solution. Bubbles
forming indicate a leak. Correct any leak found.
11. Verify proper operation, then replace the outer door.
CLOSE-UP INSIDE VIEW OF
THE COMBUSTION CHAMBER.
SLOT
TIP
MANIFOLD TUBE
FIGURE 29.
BRACKET
Piezoelectric Igniter System
The piezoelectric igniter system consists of the igniter
button, electrode, and wire. The pilot is ignited by an
electric spark generated when the igniter button is pressed.
(See Figure 30).
THERMOPILE
PILOT
VAC
ELECTRODE
WIRE TO ELECTRODE
IGNITER BUTTON
FIGURE 30.
PILOT/
THERMOPILE
BRACKET
T esting the Igniter System
Turn off the gas to the water heater at the manual gas
shut-off valve. Watch the electrode tip while activating the
igniter. A visible spark should jump from the electrode. To
avoid shock, do not touch the burner or any metal part
on the pilot or pilot assembly. If no spark is visible, check
the wire connections and make sure the electrode is not
broken. Replace the igniter if defective. Dirt and rust on the
pilot or electrode tip can prevent the igniter spark. Wipe
clean with a damp cloth and dry completely. Rust can be
removed from the electrode tip and metal surfaces by
lightly sanding with an emery cloth or fine grit sandpaper.
Removing and Replacing the Gas Control
Valve/Thermostat
IMPORTANT: This water heater has a resettable thermal
switch installed. Do not attempt to disable or modify this
feature in any way. Use only factory authorized
replacement parts.
Removing the Gas Control Valve/Thermostat:
1. Turn the gas control/temperature knob to the “OFF”
position (Figure 19A).
2. Turn off the gas at the manual shut-off valve on the gas
supply pipe (Figure 3).
3. Drain the water heater. Refer to the section of “Draining
and Flushing” and follow the procedure.
4. Disconnect the igniter wire from the igniter lead wire. Use
needle nose pliers to disconnect the red (+) and white (-)
thermopile wires. Disconnect the pilot tube (7/16” wrench)
and manifold tube (3/4” wrench) at the gas control valve/
thermostat (Figure 22). NOTE: L.P. Gas systems use
reverse (left-hand) threads on the manifold tube.
5. Refer to “Gas Piping” (Figure 3) and disconnect the
ground joint union in the gas piping. Disconnect the
remaining pipe from the gas control valve/thermostat.
6. To remove the gas control valve/thermostat, thread
a 4” section of gas pipe into the inlet and use it to turn
the gas control valve/thermostat (counterclockwise.)
Do not use a pipe wrench or equivalent to grip body.
Damage may result, causing leaks. Do not insert
any sharp objects into the inlet or outlet connections.
Damage to the gas control valve/thermostat may
result.
Replacing the Gas Control Valve/Thermostat:
To replace the gas control valve/thermostat, reassemble
in reverse order. When replacing the gas control valve/
thermostat, thread a 4” section of gas pipe into the inlet and
use it to turn the gas control valve/thermostat (clockwise).
DO NOT OVER TIGHTEN; damage may result.
• Be sure to use approved Teflon® tape or pipe joint
compound on the gas piping connections and fitting on
the back of the gas control valve that screws into the
tank.
• Be sure to remove the pilot ferrule nut from the new gas
control valve/thermostat.
• Turn the main gas supply on and check the gas supply
connections for leaks. Correct any leak found.
Next, light the pilot and main burner, then check the
manifold tube and pilot tube connections for leaks.
Correct any leak found.
Use an approved noncorrosive leak detection solution.
If such a solution is not available, use a mixture of
hand dish washing soap and water (one part soap
to 15 parts water) or childrens’ soap bubble solution.
Bubbles forming indicate a leak.
• Be sure tank is completely filled with water before
lighting and activating the water heater. Follow the
“Lighting Instructions” on page 20.
• If additional information is required, reference
the number on the cover of this manual for service
information.
TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company
28
FVIR System Operational Checklist
1. Manifold gasket properly sealed.
2. Viewport not damaged or cracked.
3. Flame-arrestor free of debris and undamaged.
4. Manifold component block properly installed.
TROUBLESHOOTING CHART
PROBLEMPOSSIBLE CAUSE(S)CORRECTIVE ACTION
BURNER WILL NOT IGNITE
1. Pilot not lit
2. Thermostat set too low
3. Main burner line clogged
4. Non-functioning thermostat
5. Base-Ring Filter blocked with lint/
dust
5. No leaks at pilot and manifold connection.
6. Manifold door screws securely tightened.
7. Depress the button on the thermal switch
1. Light pilot
2. Turn temp. dial to desired temperature
3. Clean, locate source and correct
4. Test Gas Control Valve/Thermostat
5. Clean filter, See “External Inspection &
Cleaning of the Base-Ring Filter” section.
6. Heater installed in a confined area
7. FVIR Flame Arrestor blocked with
lint/dust.
SMELLY WATER
BURNER FLAME YELLOWLAZY
1. Sulfides in the water1. Replace the anode with a special anode
1. Insufficient combustion air
2. Low gas pressure
3. Water heater flue or vent system
blocked
4. Main burner line clogged
5. Base-Ring Filter blocked with lint/
dust
6. Heater installed in a confined area
7. FVIR Flame Arrestor blocked with
lint/dust.
8. Obstruction in main burner orifice
PILOT WILL NOT LIGHT OR
REMAIN LIT
1. Non-functioning igniter
2. The thermal switch tripped
3. Wire lead connection at thermal
switch loose
4. Thermopile connection loose
5. Air in gas line
6. Low gas pressure
7. N o g as
8. Dirt in gas lines
9. Cold drafts
10. Thermostat temperature limit was exceeded. Status light will blink 4 flashes.
11. Pilot line or orifice clogged
12. Non-functioning thermopile
13. Air for combustion obstructed
14. FVIR Flame Arrestor blocked with
lint/dust
15. Flammable vapors incident, FVIR
function actuated
16. Base-Ring Filter blocked with lint/
dust
HIGH OPERATION COSTS
1. Thermostat set too high
2. Sediment or lime in tank
3. Water heater too small for job
4. Wrong piping connections
5. Leaking faucets
6. Gas leaks
7. Wasted hot water
8. Long runs of exposed piping
9. Hot water piping in exposed wall
INSUFFICIENT HOT WATER 1. Thermostat set too low
2. Sediment or lime in tank
3. Water heater too small
4. Wrong piping connections
5. Leaking faucets
6. Wasted hot water
7. Long runs of exposed piping
8. Hot water piping in outside wall
9. Low gas pressure
6. Provide fresh air ventilation
7. Clean filter, See “Cleaning the Combustion
Chamber and Flame-Arrestor” section.
1. Provide ventilation to water heater
2. Check with gas utility company
3. Clean, locate source and correct
4. Clean, locate source and correct
5. Clean filter, See “External Inspection &
Cleaning of the Base-Ring Filter” section.
6. Proper fresh air ventilation
7. Clean filter, See “Cleaning the Combustion
Chamber and Flame-Arrestor” section.
8. Clean or replace orifice
1. Replace igniter pilot assembly
2. See Pilot Light Troubleshooting Flowchart section
3. Remove and reconnect the wire leads at
thermal switch, confirm connections are tight
and not loose
4. Finger tighten; then 1/4 turn with wrench
5. Bleed the air from the gas line
6. Check with gas utility company
7. Check with gas utility company
8. Notify utility-install dirt trap in gas line
9. Locate source and correct
10. Replace thermostat
11. Clean, locate source and correct
12. Replace thermopile
13. See maintenance section for inspection and
cleaning of flame arrester
14. Clean filter, See “Cleaning the Combustion
Chamber and Flame-Arrestor” section.
16. Clean filter, See “External Inspection &
Cleaning of the Base-Ring Filter” section.
1. Set temperature dial to lower setting
2. Drain/flush-provide water treatment if needed
3. Install adequate heater
4. Correct piping-dip tube must be in cold inlet
5. Repair faucets
6. Check with utility-repair at once
7. A dv i s e c u s t om er
8. Insulate piping
9. Insulate piping
1. Turn temperature dial to desired setting
2. Drain/flush-provide water treatment if needed
3. Install adequate heater
4. Correct piping-dip tube must be in cold inlet
5 Repair faucets
6. Advise customer
7. Insulate piping
8. Insulate piping
9. Check with gas utility company
29
PROBLEMPOSSIBLE CAUSE(S)CORRECTIVE ACTION
SLOW HOT WATER
RECOVERY
DRIP FROM RELIEF VALVE
THERMOSTAT FAILS TO
SHUT-OFF
COMBUSTION ODORS
SMOKING AND CARBON
FORMATION (SOOTING)
CONDENSATION
BURNER FLAME FLOATS
AND LIFTS OFF PORTS
BURNER FLAME TOO HIGH
1. Insufficient combustion air
1. Provide ventilation to water heater. Check
flue way, flue baffle, and burner
2. Water heater flue or vent system
2. Clean flue, locate source and correct
blocked
3. Low gas pressure
4. Improper calibration
5. Base-Ring Filter blocked with lint/
dust
3. Check with gas utility company
4. Replace thermostat
5. Clean filter, See “External Inspection &
Cleaning of the Base-Ring Filter” section.
6. Clean filter, See “Cleaning the Combustion
6. FVIR Flame Arrestor blocked with
Chamber and Flame-Arrestor” section.
lint/dust.
1. Excessive water pressure
2. Heater stacking
3. Closed water system
1. Use a pressure reducing valve and relief
valve
2. Lower the thermostat setting
3. See “Closed System/Thermal Expansion”
1. Thermostat not functioning properly
1. Replace thermostat
2. Replace thermostat
2. Improper calibration
1. Insufficient combustion air
1. Provide ventilation to water heater. Check
flue
2. Water heater flue or vent system
blocked
way, flue baffle, and burner
2. Clean, locate source and correct
3. Heater installed in a confined area
4. Base-Ring Filter blocked with lint/
dust
3. Provide fresh air ventilation
4. Clean filter, See “External Inspection &
Cleaning of the Base-Ring Filter” section.
5. FVIR Flame Arrestor blocked with
lint/dust.
1. Insufficient combustion air
5. Clean filter, See “Cleaning the Combustion
Chamber and Flame-Arrestor” section.
1. Provide ventilation to water heater. Check
flue way, flue baffle, burner
2. Low gas pressure
3. Water heater flue or vent system
2. Check with gas utility company
3. Clean, locate source and correct
blocked
4. Thermostat not functioning properly
5. Heater installed in a confined area
6. Burner flame yellow-lazy
7. Base-Ring Filter blocked with lint/
dust
4. Replace thermostat
5. Provide fresh air ventilation
6. See “Burner Flame Yellow-Lazy”
7. Clean filter, See “External Inspection &
Cleaning of the Base-Ring Filter” section.
8. Clean filter, See “Cleaning the Combustion
Chamber and Flame-Arrestor” section.
8. FVIR Flame Arrestor blocked with
lint/dust.
1. Temperature setting too low1. Increase the temperature setting. Refer
to the “Condensation” sub-section of this
manual’s Troubleshooting Guide.
1. Orifice too large
2. High gas pressure
3. Water heater flue or vent system
blocked
1. Replace with correct orifice
2. Check with gas utility company
3. Clean flue and burner-locate source and correct
4. Cold drafts
4. Locate source and correct
1. Orifice too large1. Replace with correct orifice
FLAME BURNS AT ORIFICE
PILOT FLAME
TOO SMALL
1. Thermostat not functioning properly
2. Low gas pressure
1. Pilot line or orifice clogged
2. Low gas pressure
30
1. Replace thermostat
2. Check with gas utility company
1. Clean, locate source and correct
2. Check with gas utility company
PILOT LIGHT TROUBLESHOOTING FLOWCHART
Section A: Pilot light will not light (new installation).
Is the manual gas shut-off valve,
located in the supply line to the
water heater, in the on position?
YES
Have you bled all the air
from the pilot tube and
gas supply line?
YES
Is the igniter producing a
spark?
NO
Follow the “Testing the Igniter
System” section in this manual.
NO
YES
Turn the manual gas shut-off valve to
the on position and follow the lighting
NO
instructions on the front of the water heater.
While repeatedly depressing the igniter
button, push in and hold the gas control/
temperature knob until the pilot is lit and
maintains a stable flame (status light will
blink). It may take up to 90 seconds of
pilot operation before status light blinks.
Once status light blinks, release the gas
control/temperature knob.
Set thermostat to desired temperature.
Section B: Pilot light repeatedly goes out.
Check the Base-Ring Filter and
Flame Arrestor for blockage due
to lint or dust. Are both the Air
Filter and Flame Arrestor clean?
YES
Refer to the “Maintenance of
your Water Heater” section of this
NO
manual for information on cleaning
the flame arrestor and burner.
Section C: Pilot light will not remain lit.
Complete this section after completing Section B.
Check for insufficient combustion air.
YES
Are the combustion air supply and ventilation openings
of sufficient size? See “Combustion Air Supply and
Ventilation” section in this manual for requirements.
YES
Does the return air duct for the furnace/
air handler/air conditioner draw its air from
the same location as the water heater?
See the “Location Requirements” section
and the “Combustion Air Supply” section.
YES
Contact a Heating and Air
Conditioning service technician
to relocate the return air duct.
The water heater’s pilot can be
extinguished when the heating
or cooling system is turned on
if the return air duct is in the
same location.
If you are still having difficulty keeping the pilot
lit, reference the number on the cover of this
manual for service information.
NO
Correct size of
NO
openings to allow
sufficient air.
Is there proper
drafting at the
drafthood? See
“Checking the Draft”
section in this manual.
YES
Check the vent system for
restrictions/obstructions and
check the vent termination
height. Refer to the “Installation
Instructions” section of this
manual for specific requirements.
NO
Does the flame
arrestor show signs
of discoloration?
YES
Shut-off the gas supply to the water heater at the
manual gas shut-off valve. Use the number on the
cover of this manual to contact Customer Service.
NO
Go to section C.
Reassemble the heater, press the thermal
NO
switch, and attempt to return the heater to
service. Does the pilot remain lit?
Set to desired temperature.
Does the diagnostic status light on the
gas control valve/thermostat give
a two flash error code?
Refer to the “Replacing the Pilot
Assembly” instructions in the manual.
Reassemble and restore to service.
YES
NO
YES
NOTE: If you are still experiencing diffi culties after following
the steps in sections A, B, and C, please use the number
on the cover of this manual to contact Customer Service.
THERMAL SWITCH LOCATION
THERMAL
SWITCH
31
FIGURE 31.
STATUS LIGHT AND DIAGNOSTIC CODE TROUBLESHOOTING CHART
LED STATUSPROBLEMCORRECTIVE ACTION
0 FLASHES (LED NOT LIT)Pilot light is not lit or Thermopile
Turn Gas Control Valve/Thermostat knob to OFF. Wait
10 minutes, then attempt to relight Pilot by following
the lighting instructions on the water heater’s label.
Until the Thermopile reaches its normal operating
temperature, the Status Light will not blink, even if the
Pilot is lit. It may take up to 90 seconds of continuous
Pilot operation before the Thermopile reaches normal
operating temperature and the Status Light starts to
blink.
If the Status Light does not blink after three lighting
attempts, check to make sure unit is getting gas.
Remove the outer door. Press reset button. Replace
outer door. Turn Gas Control Valve/Thermostat knob
to OFF. Wait 10 minutes, then attempt to light Pilot by
following the lighting instructions on the water heater’s
label. Look through the view port for the Pilot flame. If
Pilot is not visible, the spark igniter or gas supply to the
Pilot should be checked.
If the Pilot is visible and the Status Light does not blink
after 90 seconds of continuous Pilot operation, the Pilot
flame may not be heating the Thermopile sufficiently
(weak Pilot), the Thermopile may be defective, or wiring
connectors may be loose.
NOTE: If the water heater has been operating but
has stopped and will not re-light, check the flamearrestor for signs of high temperature (blue or black)
discoloration indicating a flammable vapor incident. If
you suspect a flammable vapor incident has occurred,
do not use this appliance. Immediately call a qualified
technician to inspect the appliance. Water heaters
subjected to a flammable vapors ignition will require
replacement of the entire water heater.
Turn Gas Control Valve/Thermostat knob to OFF. Wait
10 minutes for the Thermopile to cool, then attempt
to relight Pilot by following the lighting instructions on
the water heater’s label.
NOTE: This gas control
valve/thermostat has built-in circuitry that requires
waiting 10 minutes between lighting attempts.
Until the Thermopile reaches its normal operating
temperature, the Status Light will not blink, even if the
Pilot is lit. It may take up to 90 seconds of continuous
Pilot operation before the Thermopile reaches normal
operating temperature and the Status Light starts to
blink.
Turn Gas Control Valve/Thermostat knob to OFF. The
Thermopile is probably defective, but loose wiring
connections or a weak Pilot flame can also cause this
symptom.
32
STATUS LIGHT AND DIAGNOSTIC CODE TROUBLESHOOTING CHART (Continued)
LED STATUSPROBLEMCORRECTIVE ACTION
4 FLASHESThe Gas Control Valve’s
temperature sensor has detected
that the water temperature was
too high. Once this condition
occurs, the Main Burner and
the Pilot Light will be shut off.
Since the Pilot light will be off,
should this condition occur, this
Flash Code will only be displayed
immediately after the Pilot has
been relit. Turn Gas Control Valve/
Thermostat knob to OFF.
5 FLASHESThe temperature sensor
(thermistor) is defective.
7 FLASHESGas Control Valve failure.Turn Gas Control Valve/Thermostat knob to OFF. Turn
Relight pilot and verify 4 flashes. If 4 flashes are
observed, turn Gas Control Valve/Thermostat knob
to OFF. Turn Main Gas Supply OFF. Replace the
Gas Control Valve/Thermostat. See “Removing and
Replacing the Gas Control Valve/Thermostat.”
Turn Gas Control Valve/Thermostat knob to OFF.
Replace the temperature sensor (thermistor).
Main Gas Supply OFF. Replace the Gas Control Valve/
Thermostat. See “Removing and Replacing the Gas
Control Valve/Thermostat.”
8 FLASHESThis condition only appears if the
gas control/temperature knob has
been turned off and the thermopile
continued to produce electric
power. This condition can occur
if the thermopile does not cool
down as quickly as expected when
the unit is shut off. This condition
can also occur if the gas control/
temperature knob has been turned
off and the pilot continues to
operate because the pilot valve is
stuck in the open position.
Make sure that the gas control valve/thermostat knob is
set to OFF. Wait one minute. Remove the outer door.
Look through the sight glass for a pilot flame. If a pilot
flame is observed with the gas control valve/thermostat
knob set to the OFF position, the pilot valve is stuck open.
Turn the main gas supply OFF. Replace the gas control
valve/thermostat. For instructions, see “Removing and
Replacing the Gas Control Valve/Thermostat.”
If the pilot flame is not observed when the gas control
valve/thermostat knob is set to the OFF position, wait 10
minutes for the thermopile to cool, then attempt to relight
the pilot by following the lighting instructions on the water
heater’s label. If this condition returns, replace the gas
control valve/thermostat. See “Removing and Replacing
the Gas Control Valve/Thermostat” for instructions.
33
NOTES
34
NOTES
35
REPAIR PARTS ILLUSTRATION
When ordering repair parts, always give the following information:
1. Model, serial, and product number
2. Type of gas
3. Item number
4. Parts description
Repair Parts List
Item
No.
1DRAFT HOOD
2HEAT TRAP (COLD) - SOME MODELS
3HEAT TRAP (HOT) - SOME MODELS
4COLD WATER DIP TUBE
5ANODE ROD
6TEMPERATURE & PRESSURE RELIEF VALVE
(LOCATED TOP OR SIDE)
7DRAIN VALVE
8GAS CONTROL VALVE/THERMOSTAT
(with thermal switch wire lead)
9OUTER DOOR
10BASE-RING FILTER
11A*PILOT / THERMOPILE ASSEMBLY KIT (Natural Gas)
11B*PILOT / THERMOPILE ASSEMBLY KIT ( L.P. Gas)
12A* BURNER (Natural Gas)
12B* BURNER (L.P. Gas)
13A* MANIFOLD / BURNER ASSEMBLY (Natural Gas)
13B* MANIFOLD / BURNER ASSEMBLY ( L.P. Gas)
14*MANIFOLD COMPONENT BLOCK
15*MANIFOLD DOOR GASKET
16*VIEWPORT ASSEMBLY
*Pictured on next page.
Parts Description
1
3
5
10
2
4
9
LEGEND
Special anode rod. (See “Anode Rod / Water Odor” section.)
Temperature and Pressure Relief Valve is required, but may
not be factory installed
Unique: FVIR System parts
6
8
7
36
Listed Parts Kits and Illustrations
Item 11A: Pilot / Thermopile Assembly kit, which contains the pilot / pilot tube assembly, thermopile, and igniter electrode.
(Natural Gas)
Item 11B: Pilot / Thermopile Assembly kit, which contains the pilot / pilot tube assembly, thermopile, and igniter electrode.
(L.P. Gas)
Item 12A: Burner (Natural Gas/Low Nox)
Item 12B: Burner (L.P. Gas)
Item 13A: Manifold / Burner Assembly: contains the door, gasket, manifold tube, pilot / thermopile assembly, manifold
component block, thermal switch, and burner. (Natural Gas/Low Nox)
Item 13B: Manifold / Burner Assembly: contains the door, gasket, manifold tube, pilot / thermopile assembly, manifold
component block, thermal switch, and burner. (L.P. Gas)
Item 14: Contains manifold component block
Item 15: Contains manifold door gasket
Item 16: Contains view port
Item # 11A
Item #11B
Item # 13B
Item # 15Item # 16
Item # 12A
Item # 12B
Item # 13A
Item # 14
37
RESIDENTIAL GAS WARRANTY
THIS WARRANTY IS APPLICABLE T O THE ORIGINAL OWNER
ONLY in accordance with the warranty terms and conditions
speci ed below.
Reliance Water Heater Company (the warrantor) will furnish the
ORIGINAL OWNER, 1) a replacement Reliance water heater of
equivalent size and current model if the glasslined tank in this
water heater leaks and, 2) a replacement part for any component
part which fails.
THE RELIANCE WATER HEATER COMPANY REPLACEMENT
MODEL OR PART WILL BE WARRANTED FOR ONLY THE
UNEXPIRED PORTION OF THE ORIGINAL WARRANTY. The
warranty period will be determined by the original date of purchase
of the water heater, or in the absence of a Bill of Sale verifying
said date, from the date of manufacture indicated on rating plate
af xed to this water heater. This warranty is not transferrable and
applies to models listed below:
MODEL SERIES: Tank Parts Labor
1212 12-year 12-year 1-year
909 9-year 9-year 1-year
616 6-year 6-year 1-year
606 6-year 6-year ------ 101 1-year 1-year -------
When the water heater has been used for other than single family
residential application;
1. The tank warranty shall be reduced to 1 year for 6 and 8 year models and to 3 years for 9 and 12 year models.
2. The parts warranty shall be reduced to 1 year for all
models.
CONDITIONS AND EXCEPTIONS
This warranty shall apply only when the water heater is installed
and operated in accordance with 1) all local re codes
plumbing codes, ordinances and regulations, 2) the printed
instructions provided with it, 3) good industry practices, and 4)
proper safety practices such as but not limited to a properly
sized drain pan piped to an adequate drain if installed in an area
where leakage from the tank or its connections would result in
damage to the area adjacent to the heater. In addition, a new
temperature and pressure relief valve, certi ed by the Canadian
Gas Association must have been properly installed and piped to
the nearest drain.
This warranty shall apply only when the heater is:
owned by the original purchaser;
installed for indoor operation only;
used at temperatures not exceeding the maximum
calibrated setting of its thermostat;
and
used at water pressure not exceeding the working
pressure shown on the heater;
lled with potable water, free to circulate at all times and with the tank free of damaging water sediment or scale
deposits;
used in a non-corrosive and non-contaminated
atmosphere;
used with factory approved anode(s) installed;
in its original installation location;
in the United States, its territories or possessions, and
Canada;
sized in accordance with proper sizing techniques for
residential water heaters;
bearing a rating plate which has not been altered, defaced
or removed except as required by the warrantor;
used in an open system or in a closed system with a
properly sized and installed thermal expansion tank;
operated with properly installed drip leg in the gas supply
line;
red with the fuel for which it was factory built;
red at the factory rated input;
operated with the inner and outer combustion chamber
doors in place and all factory seals to combustion
chamber intact.
Any accident to the water heater or any part thereof (including
freezing, re, oods, or lightning), any misuse, abuse or alteration
of it, any operation of it in a modi ed form, any operation of the
water heater on desalinated (deionized) water, or any damage
caused by attempts to repair tank leaks or
warranty. This warranty does not cover water heaters replaced for
cosmetic reasons or for reasons of noise, taste, odor, discolored
and/or rusty water. This warranty does not apply to water heaters
used to heat pools, whirlpools or hot tubs or used for space heating
where its sizing does not conform with speci cations of the heating
component manufacturer.
This warranty gives you speci c legal rights, and you may have
other rights which vary under the laws of each state. If any
provision of this warranty is prohibited or invalid under applicable
state law, that provision shall be ineffective to the extent of the
prohibition or invalidity without invalidating the remainder of the
affected provision or the other provisions of this warranty.
UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL
PROVIDE ONLY A REPLACEMENT W A TER HEATER OR PART
THEREOF. THE OWNER IS RESPONSIBLE FOR ALL OTHER
COSTS. Such costs may include but are not limited to:
a. Labor charges for service, removal, or reinstallation of
the water heater or part thereof.
b. Shipping and delivery charges for forwarding the new water
heater or replacement part from the nearest distributor
38
parts, will void this
SERVICE AND LABOR RESPONSIBILITY
and returning the claimed defective heater or part to such
distributor.
c. All cost necessary or incidental for handling and
administrative charges, and for any materials and/or
permits required for installation of the replacement heater
or part.
LIMITATION ON IMPLIED WARRANTIES
Implied warranties, including any warranty of merchantability
imposed on the sale of this heater under state law are limited
to one year duration for the heater or any of its parts. Some
states do not allow limitations on how long an implied warranty
lasts, so the above limitations may not apply to you.
CLAIM PROCEDURE
Any claim under this warranty should be initiated by
contacting:
Reliance Water Heater Company
500 Tennessee Waltz Parkway Ashland City, Tennessee 37015.
Phone: 1-800-365-4054
DAMAGE. THE WARRANTOR SHALL NOT BE LIABLE
BY VIRTUE OF THIS WARRANTY OR OTHERWISE
FOR DAMAGE TO ANY PERSONS OR PROPERTY,
WHETHER DIRECT OR INDIRECT, AND WHETHER
ARISING IN CONTRACT OR IN TORT. IF THE GLASSLINED TANK IN THIS WATER HEATER SHALL PROVE
UPON EXAMINATION BY THE WARRANTOR TO HAVE
LEAKED DUE TO NA TURAL CORROSION FROM POT ABLE
WATER THEREIN, DURING THE STATED WARRANTY
PERIOD, THE WARRANTOR WILL SUPPLY A COMPLETE
NEW RELIANCE WATER HEATER OF EQUIVALENT SIZE
AND CURRENT MODEL. SHOULD GOVERNMENTAL
REGULA TIONS OR INDUSTRY ST ANDARDS PROHIBIT THE
MANUFACTURER FROM FURNISHING A COMPARABLE
MODEL REPLACEMENT UNDER THIS WARRANTY, THE
OWNER WILL BE FURNISHED WITH THE CLOSEST
COMPARABLE WATER HEATER MEETING THE THEN
CURRENT GOVERNMENTAL REGULATIONS AND
INDUSTRY STANDARDS. A SUPPLEMENTARY FEE MAY
BE ASSESSED TO COVER THE ADDITIONAL COST
ASSOCIATED WITH THE CHANGES MADE TO MEET
APPLICABLE REGULATIONS AND STANDARDS.
IMPORTANT INFORMATION
Replacement Parts may be ordered through authorized
servicers or retailers or by contacting:
Reliance Water Heater Company
500 Tennessee Waltz Parkway Ashland City, Tennessee 37015.
Phone: 1-800-821-2017
The warrantor will only honor replacement with identical or
similar water heater or parts thereof, which are manufactured
by the warrantor.
DISCLAIMERS
NO EXPRESS WARRANTY HAS BEEN OR WILL BE
MADE IN BEHALF OF THE WARRANTOR WITH RESPECT
TO THE MERCHANTABILITY OF THE HEATER OR THE
INST ALLATION, OPERATION, REPAIR OR REPLACEMENT
OF THE HEATER OR PARTS. THE WARRANTOR SHALL
NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF
USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE
TO PERSONAL PROPER TY , OR OTHER CONSEQUENTIAL
Model Number ________________________________
Serial Number ________________________________
INSTALLATION INFORMATION
Date Installed ________________________________
Company’s Name _____________________________
Street or P.O. Box _____________________________
_____________________________________________
City, State, and Zip Code ________________________
_____________________________________________
Phone Number ________________________________
Plumber’s Name ______________________________