Installation
Instructions
Power
The Repeater is powered from an AC or DC power source
depending on the model chosen.
CBR-2AC, CBR-2DC
CBR-3AC, CBR-3DC
AC power requiremen ts are 120/240 Vac, 50/60 Hz,
15 W. The power cord connection to the Repeater is
a standard IEC 320 plug. Different type s of p owe r
cords can be used to adapt to v a rious power
sources.
DC power requirement i s 24V d c, 15W . It is imp ortant to
note that the CBR-2DC is considere d to have a permanent connection to the power supply. A readily accessible disconnect device is required between the power
connections on th e Repeater and its power source. This
shall be provide d during the installation of the u nit in a
manner to comply with local electrical re g ula tions. The
power wiring should also be protected from electrical
surge.
CARRIERBAND
FIBER OPTIC
REPEATERS
Grounding
Both F-connectors are grounded to the Repeater’s
case to reduce RFI emissions.
Installation
The Repeater is connected to segments of the Carrierband
network like any other station through a drop cable and a
tap. The following should be considered whe n insta lling a
Repeater:
The Repeater should be installed in a ccord a nce with the
hazardous area control drawing on the last page of these
installation instructions.
Place the Repeater where its indicator lights can be seen.
This will help ide ntif y and isolate network p rob le ms if
they occur.
While the Repe ate r is f u lly e nclose d , it is n ot wa terproof.
Install the Repeater in a dry place.
The Repeater operates at temperatures
between -20 and +65 degrees Centigrade
(-4 to 150 degrees F). Howeve r, d o not install
the Repeater in p laces whe re it will b e he a te d
by other equipment or where there is no airflow.
No special requirements for mounting. 19” ra ck mount-
ing kits for Repeaters are available:
CBR-A0050A Single
CBR-A0060A Double
For guidance on Carrierband networks and Industrial fiber
optics, see Relcom' s “Carrierband Network Handbook” and
“Guide to Industrial Fiber Optics” on our website:
www.relcominc.com.
More detailed op e rat iona l inf orma tion for the rep e at e rs is
available on our website in document 500-375.
On AC powere d R e peaters the ca se is con nected
to the mains ground and to the ground stud.
On DC powered Repeaters the case is
connected to the ground terminal and ground stud.
Attach a ground wire from the ground stud to the
grounding fa cilitie s p rov ided in the build in g . Use a
grounding wire t ha t h a s a curre n t ca rrying cap a city
equal or greater than that of the d rop cab le oute r
conductor.
Front Pane l Connectors
Test: F-type (Normally not connected. See manual
for information.)
A: F-type (connected to an IEEE-802.4 tap d rop p ort).
(torque to 35 in-lbs.)
B: ST-type front panel fiber-op tic connectors.
Note: OEM models have the power and ground con-
nections on the front of the unit.
DC Models :
WARNING: FOR PERMANENTLY CONNEC TED EQU IP-
MENT, A READILY ACCESSIBLE DISCONNECT DEVICE
SHALL B E INCORPORATE D IN THE FIXED W IRING.
AVERTISSEMENT: POUR LES ÉQUIPEMENTS RACCORDÉS EN PERMANENCE, UN DISPOSITIF DE DÉCONNEXION FACILEMENT ACCESSIBLE DOIT ÊTRE INCORPORÉ
DANS LE C ÂBLAGE FIXE.
Page 1 of 3
Forest Grove, Oregon 97116 USA
(503) 357-5607 or (800) 382-3765
500-169 Rev. E.0 CBR Installaton
2221 Yew Street
FAX (503) 357-0491
www.relcominc.com

Installation
Instructions
CBR-2AC, CBR-2DC
CBR-3AC, CBR-3DC
CARRIERBAND
FIBER OPTIC
REPEATERS
Equipment Ratings:
Pollution Degree 2;
Installation category II;
Altitude 2000m;
Humidity 80% up to 31°C de creasing line arly to 50% rH
at 40°C; max. 80% rH non-condensing.
Electrical supply
AC versions: 120/240 Vac, 50/60 Hz, 15W
DC versions: 24Vdc, 15W
Indoor use only. Not intended f or outd oor e x p osure .
Must be adequate ly p rotecte d f rom the e le me nts, d ust,
moisture, hazardou s sub stances, etc.
Temperature –20°C to 65°C
Electrical supply variations not to exceed +/- 10% of the
nominal values above.
This equipment has been certified by CSA for electrical safety. Use outside of these specifications and instructions may
impair that protection.
Equipment Maintenance and Service:
No regular maintena nce is re q u ired on the product.
Proper operation requires that the connections to the
unit are done correctly and that they do not loosen.
Occasional maintenance may be required to ensure the
connections rema in secure.
These products contain no user serviceable parts. Please
contact the factory for repair options. Do not open and
attempt service to the unit.
Ensure that the Mains power cord used to connect the
unit to AC power is adequate ly ra te d .
If cleaning is necessary, use a damp cloth and if needed
a mild deterge nt.
Note:
These instructions apply to the OEM versions of
the CBR-2 products which contain a n “H” or
“HC” suffix on the listed part numbers.
Page 2 of 3
Forest Grove, Oregon 97116 USA
(503) 357-5607 or (800) 382-3765
500-169 Rev. E.0 CBR Installaton
2221 Yew Street
FAX (503) 357-0491
www.relcominc.com

Installation
Instructions
CBR-2AC, CBR-2DC
CBR-3AC, CBR-3DC
CARRIERBAND
FIBER OPTIC
REPEATERS
Page 3 of 3
Forest Grove, Oregon 97116 USA
(503) 357-5607 or (800) 382-3765
500-169 Rev. E.0 CBR Installaton
2221 Yew Street
FAX (503) 357-0491
www.relcominc.com