Relcom CBR-2AC, CBR-2DC, CBR-3AC, CBR-3DC Installation Instructions Manual

Installation Instructions
Power
The Repeater is powered from an AC or DC power source depending on the model chosen.
CBR-2AC, CBR-2DC CBR-3AC, CBR-3DC
 AC power requiremen ts are 120/240 Vac, 50/60 Hz,
15 W. The power cord connection to the Repeater is a standard IEC 320 plug. Different type s of p owe r cords can be used to adapt to v a rious power sources.
 DC power requirement i s 24V d c, 15W . It is imp ortant to
note that the CBR-2DC is considere d to have a perma­nent connection to the power supply. A readily accessi­ble disconnect device is required between the power connections on th e Repeater and its power source. This shall be provide d during the installation of the u nit in a manner to comply with local electrical re g ula tions. The power wiring should also be protected from electrical surge.
CARRIERBAND
FIBER OPTIC
REPEATERS
Grounding
Both F-connectors are grounded to the Repeater’s case to reduce RFI emissions.
Installation
The Repeater is connected to segments of the Carrierband network like any other station through a drop cable and a tap. The following should be considered whe n insta lling a Repeater:
 The Repeater should be installed in a ccord a nce with the
hazardous area control drawing on the last page of these installation instructions.
 Place the Repeater where its indicator lights can be seen.
This will help ide ntif y and isolate network p rob le ms if they occur.
 While the Repe ate r is f u lly e nclose d , it is n ot wa terproof.
Install the Repeater in a dry place.
 The Repeater operates at temperatures
between -20 and +65 degrees Centigrade (-4 to 150 degrees F). Howeve r, d o not install the Repeater in p laces whe re it will b e he a te d by other equipment or where there is no airflow.
 No special requirements for mounting. 19” ra ck mount-
ing kits for Repeaters are available: CBR-A0050A Single CBR-A0060A Double
For guidance on Carrierband networks and Industrial fiber optics, see Relcom' s “Carrierband Network Handbook” and “Guide to Industrial Fiber Optics” on our website: www.relcominc.com.
More detailed op e rat iona l inf orma tion for the rep e at e rs is available on our website in document 500-375.
 On AC powere d R e peaters the ca se is con nected
to the mains ground and to the ground stud.
 On DC powered Repeaters the case is
connected to the ground terminal and ground stud.
 Attach a ground wire from the ground stud to the
grounding fa cilitie s p rov ided in the build in g . Use a grounding wire t ha t h a s a curre n t ca rrying cap a city equal or greater than that of the d rop cab le oute r conductor.
Front Pane l Connectors Test: F-type (Normally not connected. See manual
for information.) A: F-type (connected to an IEEE-802.4 tap d rop p ort).
(torque to 35 in-lbs.)
B: ST-type front panel fiber-op tic connectors. Note: OEM models have the power and ground con-
nections on the front of the unit.
DC Models : WARNING: FOR PERMANENTLY CONNEC TED EQU IP-
MENT, A READILY ACCESSIBLE DISCONNECT DEVICE SHALL B E INCORPORATE D IN THE FIXED W IRING.
AVERTISSEMENT: POUR LES ÉQUIPEMENTS RACCOR­DÉS EN PERMANENCE, UN DISPOSITIF DE DÉCONNEX­ION FACILEMENT ACCESSIBLE DOIT ÊTRE INCORPORÉ DANS LE C ÂBLAGE FIXE.
Page 1 of 3
Forest Grove, Oregon 97116 USA
(503) 357-5607 or (800) 382-3765
500-169 Rev. E.0 CBR Installaton
FAX (503) 357-0491
www.relcominc.com
Installation Instructions
CBR-2AC, CBR-2DC CBR-3AC, CBR-3DC
CARRIERBAND
FIBER OPTIC
REPEATERS
Equipment Ratings:
 Pollution Degree 2;  Installation category II;  Altitude 2000m;  Humidity 80% up to 31°C de creasing line arly to 50% rH
at 40°C; max. 80% rH non-condensing.
 Electrical supply
AC versions: 120/240 Vac, 50/60 Hz, 15W DC versions: 24Vdc, 15W
 Indoor use only. Not intended f or outd oor e x p osure .
Must be adequate ly p rotecte d f rom the e le me nts, d ust, moisture, hazardou s sub stances, etc.
 Temperature –20°C to 65°C  Electrical supply variations not to exceed +/- 10% of the
nominal values above.
This equipment has been certified by CSA for electrical safe­ty. Use outside of these specifications and instructions may impair that protection.
Equipment Maintenance and Service:
No regular maintena nce is re q u ired on the product. Proper operation requires that the connections to the unit are done correctly and that they do not loosen. Occasional maintenance may be required to ensure the connections rema in secure.
These products contain no user serviceable parts. Please contact the factory for repair options. Do not open and attempt service to the unit.
Ensure that the Mains power cord used to connect the unit to AC power is adequate ly ra te d .
If cleaning is necessary, use a damp cloth and if needed a mild deterge nt.
Note:
These instructions apply to the OEM versions of the CBR-2 products which contain a n “H” or “HC” suffix on the listed part numbers.
Page 2 of 3
Forest Grove, Oregon 97116 USA
(503) 357-5607 or (800) 382-3765
500-169 Rev. E.0 CBR Installaton
FAX (503) 357-0491
www.relcominc.com
Installation Instructions
CBR-2AC, CBR-2DC CBR-3AC, CBR-3DC
CARRIERBAND
FIBER OPTIC
REPEATERS
Page 3 of 3
Forest Grove, Oregon 97116 USA
(503) 357-5607 or (800) 382-3765
500-169 Rev. E.0 CBR Installaton
FAX (503) 357-0491
www.relcominc.com
Loading...