HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
1 - Description
RGC 120 and RGC 170 Hot Water Storage Tanks (further “tank“) with one enamelled heat exchanger (e.g. for
connecting a heat pump), permitting installation of an electric heating element.
In order to reach proper working of the tank, it is necessary to design optimum hydraulics of the whole system,
i.e. position of circulation pumps for heat sources and heating circuits, valves, non-return valves etc.
1.1 - Models
The tanks are available in volumes of 114 and 166 litres.
1.2 - Tank protection
Enamelled inner surface of the tank and coil heat exchanger guarantee a long service life. Enamel is done
according to DIN 4753 standard. Further qualitative improvement is reached thanks to a magnesium anode
installed inside the tank.
1.3 - Thermal insulation
The tanks come with an ecologic polyurethane foam insulation 54 and 58 mm thick. Its outer mantle is made of
white hard plastic. The insulation is not detachable.
1.4 - Connection points on the tank
2 connections with G 3/4“ M, to heat exchanger circuit
2 connections with G 3/4“ M, for cold water inlet and hot water outlet
1 connection with G 3/4“ M, for recirculation
1 connection with G 5/4“ F, for a magnesium anode rod
1 sheath, 15 mm diam.
1 connection with G 1/2“ F, for thermometer
1 connection with G 6/4“ M, for an el. heating element
1 connection with G 1/2“ F, universal inlet/outlet
1.5 - Packaging
Tanks are delivered standing, each screwed to its pallet, packed in a cardboard box. It is forbidden to transport
and/or store the tanks in a horizontal position.
2 - General Information
The appliance shall be installed by a qualied person according to valid rules and Manufacturer‘s Manual.
This manual is an integral and important part of the product and must be handed over to the User. Read
carefully the instructions in this manual as they contain important information concerning safety, installation,
operation and maintenance. Keep this manual for later reference.
Using the tank for other purposes than stated above is forbidden and the manufacturer accepts no responsibi lity
for damage caused by improper or wrong use.
3 - Operation
This tank is designed for operation in pressure circuits. Hot water is heated in the integrated hot-water heat
exchanger (heating coil) inside the tank from several possible heat sources like heat pumps or various kinds of
hot-water boilers. An electric heating element can be installed into the tank for DHW backup heating.
Hot water temperature should be kept between 60 and 65 °C. This temperature guarantees the best operation
and at the same time, it prevents formation of Legionella bacteria.
3
│
Page 4
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
4 - Technical Data and Dimensions of Hot Water
Storage Tanks
- RGC 120
Dimensions
pos. description
DHW heating
W1cold waterG 3/4ʺ M1075
W2hot waterG 3/4ʺ M1075
W3recirculationG 3/4ʺ M1075
Auxiliary heat source
E1
electric heating element for DHW G 6/4ʺ F235
Control and safety
C1
sheathØ 15 mm 990
Tthermometer G 1/2ʺ F 740
Heat sources
X1
X2return to heat sourceG 3/4ʺ M1075
Other
U1
universal inlet/outlet G 1/2ʺ F 100
A1magnesium anode rod G 5/4ʺ F 960
connection
G 3/4ʺ M1075
height [mm]
HEAT EXCHANGER PRESSURE DROP
4
│
Page 5
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
Main Features
Hot water tank with integrated heat exchanger and enamelled
non-detachable insulation and a magnesium anode rod that
Application
Code19441
Standing loss65 W
Storage volume114 l
Technical Data
Ambient temperature2 to 45 °C
Max. relative humidity80%
Total volume120 l
Heat exchanger volume6 l
Max. working pressure in tank6 bar
Max. working pressure in heat exchanger6 bar
Max. temperature in tank95 °C
Max. temperature in heat exchanger100 °C
Heat exchanger surface area1.4 m²
Tank height1045 mm
Tank diameterØ 457 mm
Tank dimensions w. insulationØ 565 mm
Tipping height1143 mm
Empty weight71 kg
protects its inner surface from corrosion. As an option,
an electronic anode rod can be installed instead
of the magnesium one, for the codes see the Accessories
table. If desired, an electric heating element can be installed
into the hot water tank.
Water (tank), water, water–glycol mixture (max. 1:1) or
water–glycerine mixture (max. 2:1) (heat exchanger).
C
Hot water heating from 10 to 45°C at heating water temp. of 60°C
Heat exchanger570 l/h (23 kW)
Materials
TankS235JR, inner surface enamelled (DIN 4753-3)
Heat exchangerS235JR+N, outer surface enamelled (DIN 4753-3)
Outer mantlehard plastic
InsulationPU foam
Accessories
El. heating elementmodels ETT-A, D, F, P, M
Heating element max. length370 mm
Electronic anode rodcode 9176
Spare parts (magnesium anode rods)
Magnesium anode rod, l = 500 mmcode 448
5
│
Page 6
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
- RGC 170
Dimensions
pos. description
DHW heating
W1
cold waterG 3/4ʺ M1030
W2hot waterG 3/4ʺ M1030
W3recirculationG 3/4ʺ M1030
Auxiliary heat source
electric heating element for DHW G 6/4ʺ F345
E1
Control and safety
sheathØ 15 mm980
C1
Tthermometer G 1/2ʺ F630
Heat sources
X1
X2return to heat sourceG 3/4ʺ M1030
Other
universal inlet/outlet G 1/2ʺ F 110
U1
A1magnesium anode rod G 5/4ʺ F930
connection
G 3/4ʺ M1030
height [mm]
HEAT EXCHANGER PRESSURE DROP
6
│
Page 7
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
Main Features
Hot water tank with integrated heat exchanger and enamelled
non-detachable insulation and a magnesium anode rod that
Application
Code19196
Standing loss80 W
Storage volume166 l
Technical Data
Ambient temperature2 to 45 °C
Max. relative humidity80%
Total volume173 l
Heat exchanger volume7 l
Max. working pressure in tank6 bar
Max. working pressure in heat exchanger6 bar
Max. temperature in tank95 °C
Max. temperature in heat exchanger100 °C
Heat exchanger surface area1.6 m²
Tank height1030 mm
Tank diameterØ 600 mm
Tank dimensions w. insulationØ 715 mm
Tipping height1210 mm
Empty weight98 kg
protects its inner surface from corrosion. As an option,
an electronic anode rod can be installed instead
of the magnesium one, for the codes see the Accessories
table. If desired, an electric heating element can be installed
into the hot water tank.
Water (tank), water, water–glycol mixture (max. 1:1) or
water–glycerine mixture (max. 2:1) (heat exchanger).
C
Hot water heating from 10 to 45°C at heating water temp. of 60°C
Heat exchanger600 l/h (24 kW)
Materials
TankS235JR, inner surface enamelled (DIN 4753-3)
Heat exchangerS235JR+N, outer surface enamelled (DIN 4753-3)
Outer mantlehard plastic
InsulationPU foam
Accessories
El. heating elementmodels ETT-A, D, F, P, M
Heating element max. length500 mm
Electronic anode rodcode 9176
Spare parts (magnesium anode rods)
Magnesium anode rod, l = 500 mmcode 448
7
│
Page 8
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
5 - Example of Assigning Connection Points
- RGC 120
Example:
With a hot-water boiler
KEY
1 – heating system expansion vessel
2 – RGC 120 hot water storage tank
3 – DHW expansion vessel
4 – safety kit for HW storage tank
5 – pump station for DHW recirculation – CSE TV ZV
6 – boiler (natural gas, electric...)
SV – cold water
TV – hot water
CV – hot water recirculation
ÚT – central heating (heating system)
KK – ball valve
ZV – check valve
AOV – automatic air vent valve
PTR – pressure temperature relief valve
REDV – pressure reducing valve (optional)
VK – drain valve
SVE – expansion vessel service valve
PV-ÚT – safety valve for heating system
MFB – Magnet Filterball
8
│
Page 9
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
- RGC 170
Example:
With a hot-water boiler and RegulusBOX
KEY
1 – Regulus heat pump (RTC, CTC)
2 – RGC 170 hot water storage tank
3 – DHW expansion vessel
4 – safety kit for HW storage tank
5 – pump station for DHW recirculation – CSE TV ZV
6 – heating system expansion vessel
7 – RegulusBOX indoor unit
SV – cold water
TV – hot water
CV – hot water recirculation
ÚT – central heating (heating system)
KK – ball valve
ZV – check valve
AOV – automatic air vent valve
PTR – pressure temperature relief valve
REDV – pressure reducing valve (optional)
VK – drain valve
SVE – expansion vessel service valve
PV-ÚT – safety valve for heating system
MFB – Magnet Filterball
BRAIDED HOSE
COMPENSATOR
9
│
Page 10
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
6 - Installation and Commissioning
Installation must meet valid rules and may be done only by qualied staff. The tank shall be placed on the
oor, as close to the heat source as possible.
Warning: Defects caused by improper installation, use or handling are not covered by warranty.
6.1 - Connection to heat sources
Connect the heating circuit to the inlet to and outlet from the heat exchanger (connection points marked X1
and X2) using G 3/4” fittings.
6.2 - Installation of an electric heating element
The G 6/4“ side tapping marked E1 is designed to accommodate an electric heating element. The hot water
storage tank can be equipped with an el. heating element depending on the tank diameter and the heating
element length. It can be controlled either directly (thermostat-equipped elements), or by a heating system
controller.
Warning: All electric heating elements shall be protected by a safety thermostat.
The installation of an electric heating element may be done by qualied staff only.
6.3 - Connection to water mains
DHW piping shall be done according to valid rules. Connect the tank to a cold water inlet (connection point
marked W1), inlet from hot water recirculation (connection point marked W3) and to DHW outlet (connection
point marked W2) using G 3/4” ttings. A 6bar safety valve shall be installed at the cold water inlet. Installation of a reducing valve to the tank inlet is recommended. If the pressure from water mains exceeds 6 bar, a
reducing valve is necessary. In order to prevent water loss, an expansion tank o fat least 5 l volume should be
installed at the cold water inlet as well.
Should the water be too hard, install a water softener before the tank. In case the water contains mechanical
impurities, install a lter.
A suitable anti-scald valve shall be installed at the hot-water outlet from the tank that prevents too hot water
from entering the taps.
Install a drain valve to the connection point U1 of the tank.
Complete DHW piping shall be properly insulated.
6.4 - Instalace elektronické anody
A so called electronic anode rod can be used instead of the magnesium one. Its principle advantage is that it
does not need to be taken out for check. Just a visual check of the electronic anode is sufficient.
Kit for hot water storage tanks of RGC 120 and RGC 170 series
CodeEl. anode length [mm]For hot water tanks
9176600 (350/250)RGC 120 and RGC 170
Should an electronic anode rod or an el. heating element be installed, it is necessary to make a connection
between the metal tank casing and the PE line.
6.5 - Commissioning
Ground the tank before commissioning.
Fill the heating circuit with the appropriate fluid and air-bleed the entire system.
Fill the tank with cold water, following this procedure:
- open the shut-off valve at the tank inlet
- open a hot water tap, as soon as water starts flowing out, tank filling is finished, close the tap
- check all connections for leaks, check the system pressure
10
│
Page 11
HOT WATER STORAGE TANKS RGC 120 and RGC 170 - www.regulus.eu
Table of limit values for total dissolved solids in hot water
Hot water quality must meet the conditions shown in the following table.
Set the heating controller in compliance with the documentation and manufacturer’s recommendations. Check
regularly a proper function of all control and adjusting elements.
CaChlorides MgNaFe
7 - Maintenance, Replacement of Magnesium
Anode Bar
If the tank is tted with a heating element, disconnect it from the mains rst.
Clean the exterior of the tank with a soft cloth and a mild detergent. Never use abrasive cleaners or solvents.
Check all tank connections for leaks.
The tanks come equipped with an anti-corrosion sacrice magnesium anode rod as standard; it protects its
inner parts against corrosion. The anode rod shall be chec ked within 12 months after commissioning and
subsequently always not later than 12 months after the last check. In locations where water contains more
ferrites or calcites, it is recommended to check the anode rod every 6 months. If more than 1/3 of its total
volume is consumed, the anode rod shall be replaced with a new one. Disregarded of its state, the magnesium
anode rod (code 448) shall be replaced with a new one within 24 months from commissioning. In case an
electronic anode rod is used, the above described procedures are not necessary. Then only a visual check of
its indication lamp is necessary every 3 months. The indication of proper working of the electronic anode rod is
described in its Manual.
If damage to a tank occurs due to neglected replacement of a magnesium anode rod or a non-working
electronic anode rod, the warranty cannot be claimed.
8 - Disposal
Packaging shall be disposed of in compliance with the valid rules. When the product reaches the end of its
life, it shall not be disposed of as household waste. It shall be dropped off at a Local Waste Recycling Centre.
Insulation shall be recycled as plastic and the steel vessel as scrap iron.
9 - Warranty
This product is covered by warranty according to the conditions described in this Manual and according to the
Warranty Certicate. A Warranty Certicate is an integral part of the supply. Tank transport or storing in
a horizontal position is considered warranty violation!