REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
1 - Description
R2BC Hot Water Storage Tank (further “tank“) with two enameled heat exchangers with G 5/4” connections
(e.g. for connecting a solar thermal system and a heat pump), enabling installation of an electric heating
element and also another el. heating element or a nned tube heat exchanger into the ange of the lateral
inspection hole.
In order to reach proper working of the tank, it is necessary to design optimum hydraulics of the whole system,
i.e. position of circulation pumps for sources and heating circuits, valves, non-return valves etc.
1.1 - Models
Ten models of 213, 299, 420, 514, 762, 883, 1493, 2007, 2510 a 2841 l capacity enabling installation of an
electric heating element or another heat source.
1.2 - Tank protection
Enameled inner surface and coil guarantee long service life. Enamel is done according to DIN 4753 standard. Further qualitative improvement is reached thanks to a magnesium anode installed inside the tank. From
R2BC 400 upwards each tank has 2 anode rods. The R2BC 3000 tank has 3 anodes.
1.3 - Thermal insulation
R2BC 200 to 500 tanks are supplied with a hard polyurethane insulation 50 mm thick with a white PVC surface. Tanks of 750 and 1000 l volume are supplied with a hard polyurethane insulation 75 mm thick with
a white PU leather surface. R2BC 1500, 2000, 2500 and 3000 tanks have the insulation 100 mm thick. The
insulation can be detached for easier handling.
1.4 - Connection points on the tank
4× lateral with G 5/4“ inner thread, to the heating coils
2× lateral with G 5/4“ inner thread, for cold water inlet and hot water outlet (R2BC 1500-3000 2× G 2”)
3× lateral with G 1/2“ inner thread, for temperature sensors and a thermometer
1× lateral with G 1“ inner thread, for recirculation
1× top with G 5/4“ inner thread, for a magnesium anode rod
1× lateral with G 6/4“ inner thread, for an el. heating element
1× ange for the lateral inspection hole
1.5 - Packaging
Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap. It is forbidden to transport
and/or store the storage tanks in a horizontal position.
2 - General Information
This Manual is an integral and important part of the product and must be handed over to the User. Read carefully the instructions in this Manual as they contain important information concerning safety, installation, operation and maintenance. Keep this Manual for later reference.
Using the tank for other purposes than stated above is forbidden and the manufacturer accepts no responsibility for damage caused by improper or wrong use.
3
│
Page 4
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
V
Ø N
3 - Technical Data and Dimensions of R2BC Models
Ø O
Tank code ................................................................................ a
Tank total volume .................................................................... b
Volume of the upper heat exchanger ..................................... c
Volume of the lower heat exchanger ...................................... d
Surface of the upper heat exchanger ..................................... e
Surface of the lower heat exchanger ...................................... f
Empty weight (transport) ......................................................... g
Max. working temperature - tank ............................................ 95 °C
Max. working temperature - heating coils .............................. 110 °C
Max. working pressure - tank ................................................. 10 bar
Max. working pressure - heating coils ................................... 10 bar
DHW heating ∆t =35 °C (80/60 - 10/45) - upper coil ............. h
DHW heating ∆t =35 °C (80/60 - 10/45) - lower coil .............. i
4
│
Page 5
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
Values in brackets are valid for tanks R2BC200 - R2BC400
Model
Tank codea64816482648364846485575816712 16713 124328474
Tank volume [l]b
Volume of the upper heat exchanger [l]c
Volume of the lower heat exchanger [l]d
Surface of the upper heat exchanger [m2]e0.80.90.90.92.42.52.533.53.8
Surface of the lower heat exchanger [m2]f0.81.51.91.92.42.54.24.54.85.2
Empty weight [kg]g96124150168270285302465543600
DHW heating ∆t=35 °C (80/60 - 10/45) upper HE [l/h] ([kW])
DHW heating ∆t=35 °C (80/60 - 10/45) lower HE [l/h] ([kW])
W1 G 1“ F67G 1“ F67G 1“ F79 G 5/4“ F 175 G 5/4“ F 220 G 5/4“ F 220 G 2“ F 315 G 2“ F 340 G 2“ F 430 G 2“ F 430
W2 G 1“ F 1164 G 1“ F 1608 G 1“ F 1581 G 5/4“ F 1595 G 5/4“ F 1590 G 5/4“ F 1840 G 2“ F 1935 G 2“ F 2210 G 2“ F 2250 G 2“ F 2550
W3 G 3/4“ F 884 G 3/4“ F 1141 G 3/4“ F 1163 G 1“ F 1235 G 1“ F 1235 G 1“ F 1235 G 1“ F 1460 G 1“ F 1650 G 1“ F 1740 G 1“ F 2040
El. heating elements
E1 G 6/4“ F 629 G 6/4“ F 914 G 6/4“ F 891 G 6/4“ F 949 G 6/4“ F 890 G 6/4“ F 890 G 6/4“ F 1255 G 6/4“ F 1310 G 6/4“ F 1400 G 6/4“ F 1400
Control and safety
C1 G 1/2“ F 884 G 1/2“ F 1141 G 1/2“ F 1163 G 1/2“ F 1235 G 1/2“ F 1235 G 1/2“ F 1235 G 1/2“ F 1460 G 1/2“ F 1650 G 1/2“ F 1740 G 1/2“ F 2040
C2 G 1/2“ F 474 G 1/2“ F 654 G 1/2“ F 660 G 1/2“ F 685 G 1/2“ F 685 G 1/2“ F 685 G 1/2“ F 945 G 1/2“ F 985 G 1/2“ F 1075 G 1/2“ F 1075
T G 1/2“ F 929 G 1/2“ F 1384 G 1/2“ F 1411 G 1/2“ F 1480 G 1/2“ F 1460 G 1/2“ F 1680 G 1/2“ F 1825 G 1/2“ F 2090 G 1/2“ F 2130 G 1/2“ F 2430
Solar thermal system
X1 G 5/4“ F 264 G 5/4“ F 264 G 5/4“ F 286 G 5/4“ F 305 G 5/4“ F 385 G 5/4“ F 385 G 5/4“ F 470 G 5/4“ F 460 G 5/4“ F 550 G 5/4“ F 550
X2 G 5/4“ F 579 G 5/4“ F 849 G 5/4“ F 846 G 5/4“ F 865 G 5/4“ F 835 G 5/4“ F 835 G 5/4“ F 1180 G 5/4“ F 1160 G 5/4“ F 1250 G 5/4“ F 1300
X3 G 5/4“ F 679 G 5/4“ F 979 G 5/4“ F 1111 G 5/4“ F 985 G 5/4“ F 990 G 5/4“ F 990 G 5/4“ F 1330 G 5/4“ F 1450 G 5/4“ F 1540 G 5/4“ F 1790
X4 G 5/4“ F 994 G 5/4“ F 1294 G 5/4“ F 1361 G 5/4“ F 1335 G 5/4“ F 1440 G 5/4“ F 1440 G 5/4“ F 1735 G 5/4“ F 2000 G 5/4“ F 2040 G 5/4“ F 2430
Flange
L1 8 x M10 257 8 x M10 257 8 x M10 268 8 x M10 335 8 x M10 400 8 x M10 400 8 x M10 520 8 x M10 550 8 x M10 640 8 x M10 640
Magnesium anode rod
A1 G 5/4“ F 1245 G 5/4“ F 1690 G 5/4“ F 1665 G 5/4“ F 1760 G 5/4“ F 1830 G 5/4“ F 2095 G 5/4“ F 2285 G 5/4“ F 2550 G 5/4“ F 2600 G 5/4“ F 2900
A2----G 5/4“ F 268 G 5/4“ F 335 G 5/4“ F 400 G 5/4“ F 400 G 5/4“ F 520 G 5/4“ F 550 G 5/4“ F 640 G 5/4“ F 640
A3------------------G 5/4“ F 1640
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
conn.
height
[mm]
4 - Operation
This tank is designed for operation in closed pressure circuits. Hot water is heated in the integrated hot-water
heat exchangers (heating coils) inside the tank from several possible heat sources like various kinds of heating
boilers, renewable energy sources (heat pumps, solar collectors).
Hot water temperature should be set to 60-65 °C. This temperature guarantees the best operation and at the
same time, it prevents formation of Legionella bacteria.
5
│
Page 6
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
5 - Examples of Assigning Connection Points
Connection point
Example I.
with a gas boiler
with a boiler and thermal store
Example II.
A1magnesium anodemagnesium anodemagnesium anode
Tthermometerthermometerthermometer
E1plugelectric heating elementelectric heating element
W1cold water inletcold water inletcold water inlet
X1outlet to a solar thermal systemoutlet to a solar thermal systemreturn line to a heat pump
X2inlet from a solar thermal systeminlet from a solar thermal systeminlet from a heat pump
X3return line to a gas boilerreturn line to a thermal storereturn line to a replace
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
6 - Installation and Commissioning
Installation must meet valid rules and may be done only by qualied staff. The tank shall be placed on the
oor, as close to the heat source as possible.
Defects caused by improper installation, use or handling are not covered by warranty.
6.1 - Connection to heat sources
Connect heating circuits to the inlets to and outlets from heating coils. The heat source for the tank - an enameled coil - connects with G 5/4” couplings.
6.2 - Connection to a solar thermal system
The tank can be used with a solar thermal system. In such a case, the inlet for hot heat-carrying liquid coming
from the solar thermal system shall be connected to the upper sleeve of the G 5/4” heating coil and the lower
outlet to the return piping to the solar thermal system. Insulate all the piping between the tank and the solar
thermal system.
6.3 - Heating element installation
The G 6/4“ side sleeve is designed to accommodate an electric heating element. Heating elements of output
up to 12 kW can be used (depending on the tank diameter and element length), connected either directly to
the mains (thermostat-equipped elements), or to a heating system controller. The installation may be done by
qualied staff only.
Warning: Electric heating elements shall be protected by a safety thermostat.
6.4 - Connection to water mains
DHW piping shall be done according to valid rules. Threaded couplers are used to connect the tank to a cold
water inlet and hot water outlet. A 6bar safety valve shall be installed at the cold water inlet. Installation of
a reducing valve to the tank inlet is recommended. If the pressure from water mains exceeds 6 bar, a reducing
valve is necessary. In order to prevent water loss, an expansion tank should be installed at the cold water inlet
as well (8 l volume for R2BC 200, 12 l volume for R2BC 300 and 400, 18 l volume for R2BC 500, 24 l volume
for R2BC 750, 35 l volume for R2BC 1000, 60 l volume for R2BC 1500, 80 l volume for R2BC 2000, 100 l
volume for R2BC 2500 and 2×60 l volume for R2BC 3000).
Should the water be too hard, install a water softener before the tank. In case the water contains mechanical
impurities, install a strainer.
A suitable thermostatic mixing valve should be installed at the hot-water outlet from the tank, preventing too
hot water from entering the taps.
Install a drain valve to the lowest point of the tank.
Complete DHW piping shall be properly insulated.
6.5 - Electronic anode rod installation
A so called electronic anode can be used instead of the magnesium one. Its principle advantage is that its
proper function is signaled by a control lamp while a magnesium anode rod needs to be taken out for check. In
such a case, just visual check of the indication lamp of the electronic anode is sufcient.
A space equal to the anode length (see the table below) is needed between the tank top and ceiling to install/
exchange the electronic anode rod. In order to protect the tank properly and meet its warranty conditions,
select an anode from the table below.
8
│
Page 9
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
Electronic Anode Kits for R2BC Hot Water Storage Tanks
Fill the heating circuits with the appropriate uids and air-bleed the entire system. Check all connections for
leaks and verify the system pressure.
Hot water quality must meet the conditions shown in the Table of limit values for total dissolved solids
in hot water, page 7 of this Manual.
Fill the heating circuits with the appropriate uids and air-bleed the entire system. Check all connections for
leaks and verify the system pressure. Set the heating controller in compliance with the documentation and
manufacturer’s recommendations. Check regularly a proper function of all control and adjusting elements.
7 - Tank Insulation
Product description
Thermal insulation is a component of tanks that prevents heat losses. Thermal insulation of polyurethane foam
with zipped PVC layer is used.
Warning
Insulation dismantling and installation shall be done in two or three persons, depending on the tank size. The
foam insulation with zipper must not be dismantled/installed at temperatures below 20 °C. If this cannot
be avoided, the insulation shall be pre-warmed in another room to at least 20 °C. It is impossible to install
insulation of lower temperature, there is a risk of damage, esp. to the zipper.
Do not use any tools for installation.
Keep away from open re.
Warranty on insulation
□ Warranty shall become null and void if:
○ the product was used for other purposes than intended.
□ Warranty does not cover:
○ usual wear and tear,
○ damage caused by re, water, electricity or a natural disaster,
○ defects caused by failure to use the product in compliance with its intended purpose,
by improper use and insufcient maintenance,
○ defects caused by mechanical damage to the product,
○ defects caused by tampering or incompetent repair.
9
│
Page 10
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu
8 - Maintenance, Replacement of Magnesium Anode Rod
If the tank is tted with a heating element, disconnect it from the mains rst. Clean the exterior of the tank with
a soft cloth and a mild detergent. Never use abrasive cleaners or solvents.
Check all connections for leaks.
The tanks are equipped with an anti-corrosion sacrice magnesium anode rod. The anode rod shall be checked within 12 months after commissioning and subsequently always not later than 12 months after the last
check. In locations where water contains more ferrites or calcites, it is recommended to check the anode every
6 months. If more than 1/3 of its total volume is consumed, the anode shall be replaced with a new one. Disregarded of its state, the anode rod shall be replaced with a new one within 24 months from commissioning.
In case an electronic anode is used, the above described procedures are not necessary. Then only a visual
check of the indication lamp is necessary every 3 months.
Proper working of the Electronic Anode is described in its User’s Manual.
If damage to a tank occurs due to neglected substitution of a magnesium anode rod or a non-working electronic anode, warranty cannot be claimed.
9 - Disposal
Packing shall be disposed of in compliance with the valid rules. When the product reaches the end of its life, it
shall not be disposed of as household waste. It shall be dropped off at a Local Waste Recycling Center. Insulation shall be recycled as plastic and the steel vessel as scrap iron.
10 - Warranty
This product is covered by warranty according to the conditions described in this Manual and according to the
Warranty Certicate. A Warranty Certicate is an integral part of the supply. Tank transport or storing in a horizontal position is considered a warranty violation!
10
│
Page 11
REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu