Regency Pro- User Manual

Page 1
Pro-Series Inserts
LONG BURNING PROCEDURES
To obtain maximum burn times between 10 – 14 hours, it is important to have the firebox and catalyst up to temperature (beyond 500º F, 260º C), after the firebox is fully loaded. Only then should the bypass damper and draft control be closed for the long burn.
User Guide
Applicable for the following units:
[
CI2600 & HI400
Pro-Series wood burning is a diff erent technology compared to regular non-catalytic inserts. With their new hybrid technology Pro­Series units are highly effi cient, long burning appliances.
Understanding the Pro-Series technology and recommended wood burning process will help you achieve extended burn times and use less wood over the heating season.
TECHNOLOGY
Regency Pro-Series units run on a hybrid catalytic system called Eco-Boost™ technology. This hybrid system allows the fuel to burn at a slower rate utilizing its full potential.
• START UP PROCEDURE
BYPASS
OPEN
DRAFT
CONTROL
OPEN
1) Before starting a fire, open the bypass damper, and fully open the draft control.
BYPASS
OPEN
DRAFT
CONTROL
OPEN
3) Allow the fire to build, adding kindling until the fire has a hold. After 5-10 minutes add medium sized logs, after a further 5­10 minutes close the door.
5)
BYPASS
CLOSED
BYPASS
OPEN
DRAFT
CONTROL
OPEN
2) Using dry kindling and rolled newspa­per, build a fire base as normal, and ignite
leaving the door slightly open.
BYPASS
CLOSED
DRAFT
CONTROL
OPEN
4) Once the fire becomes established add large logs to the firebox until it is fully loaded. Typically, after 20-30 minutes you should be able to close the bypass damper as temperatures will have reached the “active” zone (beyond 500º F, 260º C).
Eco-Boost™
Hybrid System
Cleans up the emissions in the air from the initial burn resulting in a
high heat output.
bypass closed; located inside firebox (top front)
Catalytic Combustor
Creates consistent heat by slowly
re-burning wood smoke particles
that would normally go up
the chimney.
DRAFT
CONTROL
to your
desire
+ -
5) Adjust the draft control for desired burn rate.
• CONTINUOUS OPERATION PROCEDURE
BYPASS BYPASS
CLOSED CLOSED
DRAFT
CONTROL
OPEN OPEN
1) With the unit and chimney now up to operational temperature the reloading process will require less time. At the end of the burn cycle and to restart the unit, open the door and spread the coals out
with a poker.
2) Then add some kindling or medium sized logs. The wood will light up almost
immediately. Follow from STEP 4 above to get your fi re back up and fi rebox fully loaded, for your next long burn.
DRAFT
CONTROL
Always leave a minimum 1-2 inches of ash. This will insulate the  rebox base and maintain a higher temperature bed of hot coals and embers for a cleaner, longer burn.
Page 2
PERFORMANCE OPTIONS
Pro-Series units offer flexibility and versatility. Enjoy the comfort of a crackling fire while entertaining (Fast & High
Burn), or set the unit to low and
maintain heat for hours on a single load (Long & Even Burn).
Fast & High Burn Long & Even Burn
Burn Time Temperature
Reloading
Visual Appearance
Log size
Bypass Damper
Draft Control
Desired for maximum heat and an
aesthetically pleasing fire
for ambience.
Shorter burn: 3-6 hours Longer burn: 6-14 hours
Medium-high output Steady even output
More frequent to maintain desired appearance and ambience
Large flickering flames; wood crackling; fire moves upward through the cata­lyst near the top front of the unit, and through the flue
Small, medium, large sized pieces of seasoned wood as required to provide the desired fire effect
Closed, after temperature reaches active zone (beyond 500º F, 260º C)
Open (or partially open) to provide desired results
Maintaining a desired long burn and
even heat level. Perfect for overnight
use or while away from the home.
Less frequently; 2-3 times per day depending on desired heat output
Lower flame height; surface of wood appears as white ash; fuel ‘bakes’; logs slowly consume themselves; catalyst glows red
Large, dense, seasoned hardwood logs deliver best results
Closed, after temperature reaches active zone (beyond 500º F, 260º C)
Closed (or mostly closed)
WOOD SIZE GUIDE
FOR BEST RESULTS:
• Use soft wood for Kindling and Medium split logs for a fast burn
• Use seasoned hard wood Large logs for a long burn (moisture content should be 20% or less)
Kindling Medium Large
WHEN RELOADING:
Each time you load fresh wood into the firebox, it is important to rst fully open the bypass damper and the draft control to prevent smoke from rolling out.
Since reloading causes the unit to drop in temperature allow it to run for 10-15 minutes before closing the bypass, and a further 10-15 minutes before closing the draft control.
DID YOU KNOW?
Hardwood will burn for longer than the equivalent amount of softwood.
Represents approximately 1/2 full load for a Pro-Series insert
SAFE REMOVAL OF ASHES
Always assume ashes are still hot, use a steel bucket for disposal.