These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certified by the Australian
Gas Association for installation and operation
as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
STYLE MODEL
See ThruP121-NGP121-LPG
Left CornerP121LC-NGP121LC-LPG
Right Corner P121RC-NGP121RC-LPG
PierP131-NGP131-LPG
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional information consult an authorized installer, service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this
or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
918-179a
02/16/06
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/P121LC/P121RC/
P131 is a hand crafted appliance and has been designed to provide you with all the warmth and
charm of a wood fireplace at the flick of a switch. The model P121/P121LC/P121RC/P131 has
been approved by the Australian Gas Association for both safety and efficiency. As it also bears
our own mark, it promises to provide you with economy, comfort and security for many trouble free
years to follow. Please take a moment now to acquaint yourself with these instructions and the many
features of your Regency Fireplace.
IMPORTANT:
If the unit is to be installed into a bathroom, optional Neo ceramic glass Part# 360-946 Front or
Part# 360-948 Side must be purchased and installed in place of the tempered glass supplied with
the unit.
2
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace3
SAFETY LABEL
This is a copy of the label that accompanies
each REGENCY P121/P121LC/P121RC/P131
Zero Clearance Room Sealed Gas Fireplace.
We have printed a copy of the contents here
for your review. The safety label is located on
the front inside base of the unit, visible when
the bottom louver is open.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
4
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
INSTALLATION
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The Regency P121/P121LC/P121RC/P131-NG
or P121/P121LC/P121RC/P131-LPG Room
Sealed Gas Fireplace must be installed in accordance AG601 and NZS 5261 and with these
instructions.Carefully read all the instructions
in this manual first. Consult the "authority having
jurisdiction" to determine the need for a permit
prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is
installed in compliance with manufacturer's
instructions and all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required tomake you aware of the following:
INSTALLATION AND REPAIR SHOULD
BE DONE BY A AUTHORIZED SERVICE
PERSON. THE APPLIANCE SHOULD BE
INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A AUTHORIZED
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPETING,
BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING
AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT
OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN THEY
ARE IN THE SAME ROOM AS THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance shall be installed in accordance with the manufacturer's installation
instructions, local gas fitting regulations,
municipal building codes, water supply regulations, electrical wiring regulations, with
AS5601-2004 (AGA gas installation code)
NZS 5261 (New Zealand)
2) See general construction and assembly
instructions. The appliance and flue should
be enclosed.
3) This appliance must be connected to the
specified flue and termination cap to the
outside of the building envelope. Never flue
to another room or inside a building. Make
sure that the flue is fitted as per Flueing
instructions.
4) Inspect the flueing system annually for
blockage and any signs of deterioration.
5) Flueing terminals shall not be recessed into
a wall or siding.
6) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
7) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
8) Wear gloves and safety glasses for protection while doing required maintenance.
9) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for
termination.
10) Under no circumstances should this appliance be modified. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
11) Installation and any repairs to this appliance
should be done by a authorized service
person. A authorized service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.
12) Do not slam shut or strike the glass door.
13) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
14) The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
INSTALLATION
CHECKLIST
Note: These units are
non-load bearing.
1) Locate appliance
a) Room location, page 8.
b) Clearances to Combustibles,
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1) Clocking the appliance to ensure the correct firing rate (rate noted on label 40,000
Btu/h NG, and 39,000 Btu/h LPG) after
burning appliance for 15 minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon.
First allow the unit to burn for 15-20 min.
to stabilize.
CAUTION: Any alteration to the product
that causes sooting or carboning that
results in damage is not the responsibility of the manufacturer.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace5
INSTALLATION
SPECIFICATIONS
P121 - See Thru
Note: These units are
non-load bearing.
P131 - Pier
6
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
P121LC - Left Corner Unit
INSTALLATION
Note: These units are
non-load bearing.
P121RC - Right Corner Unit
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace7
INSTALLATION
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your stove,
ensure that the clearances are met as
outlined on page 9.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or
raised up on a platform to enhance its visual
impact. If the appliance is going to be installed on carpeting, combustible linoleum
tile or other combustible material other than
wood flooring, the appliance must be installed on a metal or wood panel extending
the full width and depth of the appliance.
4) The Room Sealed Gas Fireplace can be
installed as follows:
A) P121 - See Thru
Model # Position
A )P121: See Thru
B)P131: Pier
C)P121LC: Left Corner
D)P121RC: Right Corner
5) This appliance is Listed for bedroom installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P121/P121LC/P121RC/P131 Room
Sealed Gas Fireplace is approved for alcove installations, which meet the clearances listed on this page.
7) We recommend that you plan your installation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
authorized inspector, dealer, or installer
review your plans before installation.
Note: For Exterior Flue Termination
Locations see page 12.
.
B) P131 - Pier
C) P121LC - Left Corner
D) P121RC - Right Corner
8
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8):
Clearance to Combustibles from:
Back0"(0mm)
Side0"(0mm)
Floor0"(0mm)
CAUTION REQUIREMENTS: The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoffs may NOT be recessed into combustible construction.
Determine the total thickness of the finished floor (eg. tile, carpet, slate) to allow
the finished surface to be flush with the base of the unit.
Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in
Diagram to the right.
Note: A non-combustible mantel may be installed at a lower height if
the framing is made of metal studs covered with a noncombustible board.
This drawing is to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area or higher using this scale.
Caution: Ensure the paint that is used on the mantel and the facing is
"heat resistant" or the paint may discolour.
Mantel Clearances
* If the 3" (76mm) metal extension trim is removed it must be replaced with a 8"
(203mm) non-combustible material.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace9
B
C
A
INSTALLATION
FRAMING AND FINISHING
1) For ease of installation, frame your fireplace after it is positioned and
the flue system is installed. Remember to install the top standoffs.
See page 11 for assembly. Use 2x4's and frame to local building
codes.
CAUTION: Verify your fireplace dimensions, framing methods
and finished wall facing details before framing. Determine the
total thickness of facing material - drywall plus ceramic tiles,
slate, etc. Allow the finish surface to be flush with the front or
side of the unit. Total facing thickness can vary from 1/2"
(13mm) to 1-1/4" (32mm) thick.
2) When locating your appliance on an exterior wall or in a chase, apply
a vapour barrier and drywall, as per local building codes. DO NOT
INSULATE THE FIREPLACE ITSELF.
CAUTION: The unit does not have to be completely enclosed in
a chase. The clearance on top of the unit is 0" to the standoffs
so combustible building materials can be laid directly on top of
the standoffs. You must maintain clearance from the flue to
combustible materials for both rigid and flex, see Flue Clearances, page 9.
P121 - See Thru
Framing Dimensions
P121 (See Thru) P131 (Pier)P121LC / P121RC
(Corner Unit)
A 25"(635mm) 25"(635mm)26-13/13"(660mm)
minus two times minus two timesminus two times
the finishing the finishingthe finishing
material thickness* material thickness* material thickness*
B 42-1/2"(1080mm) 42-1/2"(1080mm)42-1/2"(1080mm)
C 46-3/4"(1187mm) 45" (1143mm)45"(1143mm)
minus one timeminus one time
the finishingthe finishing
material thickness* material thickness*
* Finish material thickness includes: drywall, ceramic tile, slate, etc.
P121LC - Corner Unit
P131 - Pier
Note: These units are
non-load bearing.
10
P121RC - Corner Unit
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
INSTALLATION
FACING & FINISHING REQUIREMENTS
This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a noncombustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.)
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped
into position.
Top Standoff Assembly
The top standoffs are shipped in a flat position and must be folded into shape and attached.
1) Remove the standoffs from the fireplace
top.
2) Take each standoff and bend into the
correct shape. Bend up at the bend lines
until the screw holes in the standoff and the
pre-punched screw holes on the fireplace
top line up.
3) Attach the standoff securely to the top with
4 screws per standoff (on opposite corners).
FLUEING
INTRODUCTION
The P121/P121LC/P121RC/P131 uses the
"balanced flue" technology Co Axial system.
The inner liner flue products of combustion to
the outside while the outer liner draws outside
combustion air into the combustion chamber
thereby eliminating the need to use heated room
air for combustion and losing warm room air up
the chimney.
Note: These flue pipes must not be con-
nected to any other appliance.
The gas appliance and flue system must be
flueed directly to the outside of the building, and
never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each direct flue gas appliance must use it's
own separate flue system. Common flue systems are prohibited.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace11
INSTALLATION
EXTERIOR FLUE TERMINATION LOCATIONS
Minimum clearances required for balanced flue terminals or
the flue terminals of outdoor appliances
according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand)
Minimum
a Below eaves, balconies or other projections:
- Appliances up to 50 MJ/h input300
- Appliances over 50 MJ/h input500
b From the ground or above a balcony300
c From a return wall or external corner500
d From a gas meter (M)1000
e From an electricity meter or fuse box (P)500
fFrom a drain or soil pipe150
g Horizontal from any building structure (unless appliance is approved
for closer installation) or obstruction facing a terminal500
h From any other flue terminal, cowl or combustion air intake500
jHorizontally from an openable window, door, or non-mechanical air inlet, or
any other opening into a building, with the exception of sub-floor ventilation
(see also Note (I)):
- Appliances up to 150 MJ/h input500
- Appliances over 150 MJ/h input1500
k Vertically below an openable window, door, or non-mechanical air inlet,
or any other opening into a building, with the exception of sub-floor ventilation
(see also Note (I)): see table below
Clearance (mm)
Clearance 'k' in mm
Space Heaters All Other Appliances
Up to 50 MJ/hUp to 50 MJ/h inputOver 50 MJ/h inputOver 150 MJ/h input
input to 150 MJ/h input
12
15050010001500
NOTES:
(I) For mechanical air inlets, including spa blowers, the clearance 'j' and 'k' shall be 1500 mm in all cases.
(II) All distances shall be measured vertically or horizontally along the wall to a point in line with the nearest
par to of the terminal.
(III) Prohibited area below electricity meter or fuse box extends to ground level.
(IV)A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on
at least two sides and a free flow of air at the appliance is achieved.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace