If the provided 3” extension trim is not installed the P121(LC/RC)/
P131 must be installed with non-combustible facing up to 8” above
the fi replace. Otherwise combustible facing may be used above the
43-1/2”
(1105mm)
46-1/4”
(1175mm)
21-1/8”
(537mm)
4-3/4”
(121mm)
extension trim.
Please refer to Page 11 (Exterior Vent Terminations)
** Refer to the manual for variations effected by fi nishing material
thickness.
69June 2007 Regency Product Specifi cations Book
Page 2
P121-P131 Gas Fireplace
Framing and Finishing
Gas Fireplaces
Parallel Wall Clearances
1) Determine the total thickness of facing material (e.g. drywall plus
ceramic tiles) to allow the fi nished surface to be fl ush with the front
of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼”
(32mm) thick.
2) Frame in the enclosure for the unit with framing material.
Gas Fireplaces
3) For exterior walls, insulate the enclosure to the same degree as
the rest of the house, apply vapor barrier and drywall, as per local
installation codes. (Do not insulate the fi replace itself.)
4) The top of the unit must not be closer than 36” (990mm) to the
ceiling.
5) Combustible material may be brought up to the top and
sides of the unit and be covered with ceramic tiles, bricks,
rock or other suitable combustible finishing materials.
Note: The unit does not have to be completely enclosed in a
chase. The clearance on top of the unit is 0” to the standoffs
so combustible building materials can be laid directly on top
of the standoffs. You must maintain proper clearances from
the vent to combustible materials (See Below).
6) Use metal studs for framing where the minimum clearance from
the vent to combustible material cannot be maintained.
Clearance Requirements
D
C
Unless otherwise stated the clearances listed below are Minimum
distances to combustible materials. Unit pictured is a P131
Parallel Wall ClearancesP121(LC/RC)/131
Min distance from glass to a parallel wall36” (914mm)
36"min.
(914mm)
36"min. (914mm)
36"min.
(914mm)
Vent ClearancesClearance Dimension
Horizontal - Top2-1/2” (64mm)
Horizontal - Side1-1/2” (38mm)
Horizontal - Bottom1-1/2” (38mm)
Vertical1-1/4” (32mm)
WARNING
Failure to maintain required clearances is a major cause of
chimney related fi res. Installation of this fi replace must comply
with these clearances.
Combustible Mantels
A
F
B
B
E
Clearance:DimensionMeasured From:
A: Mantel Height3” (76mm)Minimum (Additional on this page)
B: Sidewall0” (0mm)Side of installed front
3” (76mm)On P121-2 See-Thru
3” clearance opposite vent.
C: Ceiling36” (914mm)Top of installed unit
D: Mantel Depth12” (305mm)Maximum (Additional on this page)
E: Alcove WidthSee Parallel Wall Clearances.
F: Alcove Depth36” (914mm)Front to back wall (Maximum)
Top of Hearth must not be higher than the base of the fi rebox.
Because of the extreme heat this fi replace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
Mantel Clearances
12
64810
12" (305mm)
Note: If the fi replace is installed
without the 3” Extension Trim,
the facing material must be
B
non combustible up to 8”
above the unit.
0
A
Mantel Clearances
Front36” (914mm)7” (178mm)3” (76mm)
ABC
3 ½" (89mm)
Top of
Unit
0
2
Drywall
Header
Standoff
3” Extension Trim
C
Side View
Note: If desired a non-combustible mantel may be installed at a
lower height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
70June 2007 Regency Product Specifi cations Book
Page 3
Gas Fireplaces
Regency Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P121/P131 Direct Vent
Gas Fireplace, have been tested and listed as a direct vent heater system
by Warnock Hersey. The location of the termination cap must conform
to the requirements in the Vent Terminal Locations diagram.
FPI Direct Vent (Flex) System Termination Kits include all the parts
needed to install the P42 using a fl exible vent.
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex
installations.
3) Horizontal sections must be supported every 3 feet.
2) 4” fl exible liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
P121-P131 Gas Fireplace
Snorkel Terminations
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,
14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are
available. Follow the same installation procedures as used for standard
Horizontal Termination. NEVER install the snorkel upside down.
Riser Vent
Termination
Dura-Vent
Snorkel
Min. 12"*
(305mm)
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement
application, proper drainage must be provided to prevent water from
entering the Snorkel Termination. Refer to Rigid Pipe Installation
instructions for details. Do not attempt to enclose the Snorkel within the
wall, or any other type of enclosure.
all sections, must not exceed
37 feet.
Total horizontal sections must not
exceed 8 feet.
Minimum of 1 foot between 90°
elbows is required.
Venting Arrangements - Vertical
Terminations
Rigid Pipe System
(Propane & Natural Gas)
The P121 /131 is approved for a maximum 35 ft. straight vertical, with
Rigid Pipe vent systems for Propane and Natural Gas.
• Vent must be supported at offsets.
• Horizontal sections must be supported every 3 feet.
• Firestops are required at each floor level and whenever
passing through a wall.
• Maintain clearances to combustible materials.
• Minimum of 1’ pipe section between elbows.
Note: Must use optional fl ue adapter when using Rigid Pipe (Part
# 510-994).
Minimum 6' 6”(2.0m)
Maximum 35'(10.7m)
When installing this unit vertically, the 45˚ elbow when installed in
conjunction with the Rigid Pipe Adapter will protrude past the unit 1-½”
(38mm) when measured from the rear standoffs.
Note: A 1-¼” (32mm) clearance from the elbow must also be
maintained.
o
45 Elbow
Rigid Pipe
Adapter
1-1/2”
(38mm)
IMPORTANT
45° Elbow
Rigid Pipe Adapter
Part # 510-994
72June 2007 Regency Product Specifi cations Book
Page 5
Gas Fireplaces
Vertical Venting with Two (2) 90° Elbows
- Initial vertical section.
Two 45° elbows = One 90° elbow
P121-P131 Gas Fireplace
Vertical Venting with Three (3) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Gas Fireplaces
OptionV+ V1HMaximum total pipe: length, of
A)1’ Min.4’ Max.
B)2’ Min.6’ Max.
C)3’ Min.9’ Max.
D)4’ Min.12’ Max.
E)5’ Min.15’ Max.
E)6’ Min.17’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 17 feet.
Minimum of 1 foot between
90° elbows is required.
Vertical Venting with Two (2) 90° Elbows
- Initial horizontal section.
Two 45° elbows = One 90° elbow
OptionH + H1VMaximum total pipe: length, of
A)2’ Max.1’ Min.
B)4’ Max.2’ Min.
C)6’ Max.3’ Min.
D)8’ Max.4’ Min.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.
OptionV+ V1H + H1Maximum total pipe: length, of
A)2’ Min.3’ Max.
B)3’ Min.6’ Max.
C)4’ Min.9’ Max.
D)5’ Min.12’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must not
exceed 12 feet.
Minimum of 1 foot between 90°
elbows is required.
Vertical Venting with Three (3) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
OptionV+ V1HH + H1 Maximum total pipe: length, of
A)2’ Min.1’ Max.2’ Max.
B)3’ Min.4’ Max.5’ Max.
C)4’ Min.6’ Max.8’ Max.
D)5’ Min.8’ Max.12’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between 90°
elbows is required.
73June 2007 Regency Product Specifi cations Book
Page 6
P121-P131 Gas Fireplace
Venting Arrangements - Horizontal
Terminations
This diagram shows allowable venting confi gurations using one 45°.
Note: Must use optional fl ue adapter (Part # 770-994) when using
Gas Fireplaces
Rigid Pipe.
• Maintain clearances to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing
through a wall.
A vent guard should be used whenever the termination is lower than the
specifi ed minimum or as per local codes.
Note: FPI Direct Vent System (Flex) is only approved for horizontal
terminations.
Gas Fireplaces
Horizontal Venting with One (1) 90°
Elbow
Two 45° elbows = One 90° elbow
OptionVHMaximum total pipe: length, of
A)1’ Min. 3’ Max.
B)2’ Min.6’ Max.
C)3’ Min.9’ Max.
D)4’ Min.12’ Max.
E)5’ Min.15’ Max.
F)6’ Min.17’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 17 feet.
Minimum of 1 foot between
90° elbows is required.
74June 2007 Regency Product Specifi cations Book
Page 7
Gas Fireplaces
Horizontal Venting with Two (2) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
P121-P131 Gas Fireplace
Horizontal Venting with Three (3) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Gas Fireplaces
OptionVH+ H1Maximum total pipe: length, of
A)1’ Min. 2’ Max.
B)2’ Min.5’ Max.
C)3’ Min.8’ Max.
D)4’ Min.11’ Max.
E)5’ Min.14’ Max.
F)6’ Min.15’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 15 feet.
Minimum of 1 foot between
90° elbows is required.
OptionV+ V1H + H1Maximum total pipe: length,
A)2’ Min.3’ Max.
B)3’ Min.6’ Max.
C)4’ Min.9’ Max.
D)5’ Min.12’ Max.
of all sections, must not
exceed 37 feet.
Total horizontal sections
must not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.
Horizontal Venting with Two (2) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
OptionHVH + H1Maximum total pipe: length, of
A)1’ Max.1’ Min.3’ Max.
B)3’ Max.2’ Min.6’ Max.
C)5’ Max.3’ Min.9’ Max.
D)8’ Max.5’ Min.12’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.
Horizontal Venting with Three (3) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
OptionHVH + H1 + H2 Maximum total pipe: length, of
A)1’ Max.2’ Min.3’ Max.
B)3’ Max.3’ Min.6’ Max.
C)5’ Max.4’ Min.9’ Max.
F)7’ Max.5’ Min.12’ Max.
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.