Regency L900-NG, L900-LP User Manual

www.regency-fi re.com
LIBERTY
TM
L900 Gas Fireplace
Owners &
Installation Manual
Unit requires 120V to
operate. See “Wiring Diagram”
section in manual for more
details. Receptacle is included
with manual package.
WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-610c
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
FOR YOUR SAFETY What to do if you smell gas:
Do not try to light any applianceDo not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour's phone. Follow the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
11/14/07
To the New Owner:
Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The L900 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model L900 has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint
yourself with these instructions and the many features of your Regency
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2005 / CSA 2.33-2005, GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91 and ANSI Z21.50b-2003 / CSA 2.22b-2003.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
®
Fireplace.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
Ensure that structural members are not cut or weakened during installation.
2
Regency® L900 Direct Vent Gas Fireplace
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Decal .....................................................4
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only) ............................5
UNIT DIMENSIONS
Unit Dimensions ..........................................................6
INSTALLATION
Important Message ......................................................7
Before You Start ............................................................7
General Safety Information ...........................................7
Installation Checklist ......................................................7
Manufactured Mobile Home Additional Requirements ..8
Locating Your Gas Fireplace .........................................8
Heatwave Duct Kit ........................................................8
Heat Release Kit ..........................................................8
Hearth Requirements ....................................................8
Clearances ....................................................................9
Mantel Clearances ......................................................10
Mantel Leg Clearances ...............................................10
Framing & Finishing .................................................... 11
Unit Assembly Prior To Installation ..............................12
Top Standoff Assembly ........................................ 12
Side Nailing Strips ...............................................12
Finishing Template .......................................................12
Venting Introduction .....................................................13
Vent Restrictor Position ...............................................13
Exterior Vent Termination Requirements .....................14
Venting Arrangements ................................................15
Horizontal Termination (Flex) ...............................15
Rigid Pipe Venting Systems ........................................16
Basic Horizontal & Vertical Terminations ............. 16
5” x 8” Rigid Pipe Cross Reference Chart ...................17
Venting Arrangements ................................................19
Allowable Horizontal Terminations ....................... 19
Venting Arrangements ................................................22
Allowable Vertical Terminations ........................... 22
Unit Installation with Horizontal Termination ................23
Unit Installation with Vertical Termination .................... 24
Horizontal Termination with Flex Vent System ............25
High Elevation .............................................................26
Gas Line Installation ....................................................26
Pilot Adjustment ...........................................................26
Gas Pipe Pressure Testing ..........................................26
SIT 825 Valve Description ...........................................26
Back-Up Battery Installation (within Power Module) ...27
Conversion Kit #546-969 from NG to LP .....................28
Brick Panel Installation ................................................34
Log Set Installation ......................................................36
Aeration Adjustment ....................................................38
Wiring Diagram ...........................................................38
OPERATING INSTRUCTIONS
Matching Remote Handset & Control Box ID Code ....39
Operating Instructions .................................................39
First Fire ......................................................................39
Lighting Procedure ......................................................39
OPERATING INSTRUCTIONS
Normal Operating Sounds of Gas Appliances .............40
Operation During Power Outage .................................40
Shutdown Procedure ...................................................40
Copy of Lighting Plate Instructions ..............................41
Maintenance Instructions ............................................42
General Vent Maintenance ..........................................42
Log Replacement ........................................................42
Thermopile / Thermocouple .........................................42
Glass Gasket ...............................................................42
MAINTENANCE
Door Glass ..................................................................42
Glass Replacement .............................................42
Back-Up Battery Replacement ....................................43
Power Module Replacement .......................................44
Control Module Replacement ......................................45
DC Sparker Replacement ...........................................46
Valve Tray Replacement ..............................................47
PARTS LIST
Main Assembly ............................................................49
Burner & Log Assembly ...............................................51
WARRANTY
The Warranty: Limited Lifetime ...................................55
Regency® L900 Direct Vent Gas Fireplace 3
SAFETY LABEL
This is a copy of the label that accompanies each L900-NG and L900-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the right hand side of the unit, visible when the exterior right side brick panel is removed.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is
INSTALLATION
the correct one.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE
`
320
Serial No. / No de serie
Listed: VENTED GAS FIREPLACE HEATER Tested to: ANSI Z21.88-2005/ CAN/CGA-2.17-M91,
ANSI Z21.50b-2003/ CSA 2.22b-2003 Certified for / Certifiée pour: CANADA AND U.S.A.
NATURAL GAS FIREPLACE: MODEL L900-NG
Model/Modele:
L900-NG
Factory Equipped For Altitude 0-4500ft. (0-1372m)
Min. Supply Pressure 5“ WC (1.25 kpa) Low Setting Man. Pressure 1.6" WC (0.39 kpa) Max. Manifold Pressure 3.5" WC (0.87 kpa) Orifice Size (Front Burner) #47 DMS Orifice Size (Back Burner) #30 DMS Minimum Input 11,000 Btu/h (3.22 ) Maximum Input 48,000 Btu/h (14.06 kW)
PROPANE GAS FIREPLACE: MODEL L900-LP
Factory Equipped For Altitude 0-4500ft. (0-1372m)
Model/Modele:
L900-LP
Min. Supply Pressure 12" WC (2.98 kpa) Low Setting Man. Pressure 3.6" WC (0.9 kpa) Max. Manifold Pressure 10" WC (2.49 kpa) Orifice Size (Front Burner) #56 DMS Orifice Size (Back Burner) #50 DMS Minimum Input 9,500 Btu/h (2.78 kW) Maximum Input 46,500 Btu/h (13.62 kW)
CSA 2.33-2005,
kW
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli­ances individual manual shut-off must be a t-handle type valve.
COPY OF SAFETY DECAL
This appliance must be installed in accordance with the manufacturer’s installation instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in
For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA501A, andwith CAN/CSA Z240 MH Mobile Home Standard in Canada. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible foruse with other gases, unlessa certified kit isused (Kit #546-969). Certified for usewith Heat Wave (Kit #946-556) andHeat Release (Kit #946-570). For use withglass doors certified with theappliance only.
the USA or the current CAN 1-B149 in Canada.
This vented gas fireplace heater is not for use with air filters.
Electrical Supply: 115 V, 0.1 A, 60 Hz
NOT FOR USE WITH SOLID FUEL
Minimum Clearances to Combustibles from Fireplace
Side Walls *A 16" (406mm)
VENTED GAS FIREPLACE HEATER
Ceiling B 49" (1245mm) Min. Mantel Height C 17-1/2" (445mm) Max. Mantel Depth **D 13” (330mm) Alcove Width E 84" (2134mm) Alcove Depth F 36" (914mm)
Non-Combustible Hearth Extension
Hearth Height G 2" (51mm) Hearth Width H 33-1/8” (841mm)
C
B
D
G
F
A
I
H
E
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
4
* Alcove side wall must have a min. of 16” (406mm) clearance on one side.
** Mantel depth taken at 27-1/2” (699mm) from front facing.
FPI Fireplace Products International Ltd., Delta BC, CANADA
MADE IN CANADA / FABRIQUE AU CANADA
918-609
Regency® L900 Direct Vent Gas Fireplace
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
INSTALLATION
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
Regency® L900 Direct Vent Gas Fireplace 5
UNIT DIMENSIONS
INSTALLATION
6
Regency® L900 Direct Vent Gas Fireplace
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The L900 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE­CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
2) The appliance when installed, must be
electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.
3) See general construction and assembly
instructions. The appliance and vent should be enclosed.
4) This appliance must be connected to the
specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.
5) Inspect the venting system annually for
blockage and any signs of deterioration.
6) Venting terminals shall not be recessed into
a wall or siding.
7) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the fi replace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for termination.
11) Under no circumstances should this
appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by an authorized service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and other fl ammable vapours and liquids).
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements
(Refer to "Framing & Finishing" section)
e) Venting Requirements (Refer to
"Venting" section)
2) Assemble Top Standoffs (Refer to "Unit
Assembly Prior to Installation).
3) Install back-up batteries. Refer to "Back-up
Battery Installation" section.
4) Convert to propane if desired (Refer to
"Conversion from NG to LP" section).
5) Slide unit into place.
6) Install vent (Refer to "Venting Arrangement"
sections).
7) Make gas connections (Refer to "Gas Line
Installation section).
8) Make electrical connections (Refer to "Wiring Diagram" section). NOTE: Unit requires
120V to operate.
9) Test the pilot (Refer to "Pilot Adjustment"
section).
INSTALLATION
10) Test Gas Pressure (Refer to "Gas Pipe Pressure Testing" section).
Regency® L900 Direct Vent Gas Fireplace 7
INSTALLATION
11) Install standard and optional features. Refer
to the following sections:
a) Interior Brick Panels b) Log Set c) Exterior Brick Panels d) Remote Control - refer to "Matching
Remote Handset & Control Box ID Code" section.
12) Final check.
INSTALLATION
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 48,000 (NG) Btu/h, 46,500 (LP) Btu/h) after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
A) Flat on Wall B) Flat on Wall Corner C) Recessed into
Wall/Alcove D) Corner
Diagram 1
4) This appliance is Listed for bedroom
installations using the standard FireWizard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.
5) The L900 Direct Vent Gas Fireplace is
approved for alcove installations, see "Clearances" section for details.
6) We recommend that you plan your installation
on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.
Note: For vent terminations refer to
"Exterior Vent Termination Locations" section.
HEATWAVE
DUCT KIT
HEAT RELEASE KIT
The Heat Release Kit expels warm air from the fi replace to the outside of the building, allowing the fi replace to be operated with less heat entering the room. The kit may be used on either the left or right side.
See Heat Release installation manual for complete details and clearances from side only.
HEARTH
REQUIREMENTS
A minimum 33-1/8" (838mm) wide x 12" (305mm) deep x 2" (51mm) thick non-combustible hearth is required if the fi nished fl oor is not fl ush with the base of the unit. The maximum height between the fi nished fl oor and sub-fl oor is 1" (25mm).
2) Ensure proper grounding using the #8
ground lug provided. See "Wiring Diagram" section.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances are met.
2) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
3) The L900 Direct Vent Gas Fireplace can be
installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.
8
The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.
Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time.
See HeatWave installation manual for complete details and clearances from side only.
The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.
12"
(305mm)
2” (51mm)
NOTE: No hearth is required when the unit is fl ush
with the fi nished fl oor as shown below.
The minimum fl oor clearance must be maintained from the top surface of the carpet, etc. to the unit base.
Regency® L900 Direct Vent Gas Fireplace
33-1/8" (838mm)
INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
INSTALLATION
The top, back and sides of the fi replace are defi ned by
standoffs. The metal ends of the standoff may NOT be
Caution Requirements
recessed into combustible construction.
Clearance to Combustibles from:
Back 0" (0mm) Side 0" (0mm) Floor 0" (0mm)
Minimum Clearance from Top of Front Facing:
Mantel min. 17-1/2" (445mm) Ceiling 49" (1245mm) from top of front facing
Side Wall to Unit:
16"* (406mm)
Horizontal Vent Clearances to Combustibles:
Top 3" (76mm) Side 2" (51mm) Bottom 2" (51 mm)
Vertical Vent Clearances to Combustibles:
All Sides 2" (51mm)
Alcove Clearances:
Min. Depth 36" (914mm) Min. Width* 84" (2134mm) Min. Height 84" (2134mm)
* Alcove side wall must have a minimum of 16" (406mm) clearance on one side.
if these clearances (air space) to combustible materials
Fire hazard is an extreme risk
are not adhered to. It is of greatest importance that this
fi replace and vent system be installed only in
accordance with these instructions.
WARNING
If converting this unit to LP, it is highly recommened the conversion be done BEFORE the unit is slid into
IMPORTANT
position for ease of conversion. See "Conversion
from NG to LP" section for instructions.
Regency® L900 Direct Vent Gas Fireplace 9
INSTALLATION
MANTEL CLEARANCES
Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing
are shown in the diagram below.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible
board.
INSTALLATION
Note: Ensure the paint that is used
on the mantel and the facing is "heat resistant" or the paint may discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
10
Regency® L900 Direct Vent Gas Fireplace
FRAMING & FINISHING
1) Frame in the enclosure for the unit with framing material. The framed
opening for the assembled kit is 50-3/4" high x 52" wide x 26-1/2" deep (1289mm x H 1321mm W x 673mm D). See Diagram 1. Also see Diagram 2 for corner installations.
Header
(On Edge)
Drywall
INSTALLATION
Header
(On Edge)
INSTALLATION
50-3/4"
(1289mm) 52”
(1321mm)
Diagram 1
Diagram 2
Non-Combustible Requirements
53-3/4"
(1365mm)
Stud
83"
(2108mm)
Min. 26-1/2"
(673mm)
17-1/2” (445mm)
Non-Combustible
Material
5”
(127mm)
2”
(51mm)
12-1/4” (311mm)
6”
(152mm)
Note: When constructing the framed opening, please ensure
there is access to install the gas lines when the unit is installed. See diagram 3 for details.
2) For exterior walls, insulate the enclosure to the same degree as the rest
of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.)
3) The unit does not have to be completely enclosed in a chase. You
must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base.
26-1/2”
(673mm)
Diagram 3
76” (1930mm)
Non-combustible
17-7/16"
(443mm)
Material
33-1/8"
(838mm)
52-1/2"
(1334mm)
IMPORTANT
If converting this unit to LP, it is highly recommened the conversion be done BEFORE the unit is slid into
position for ease of conversion. See "Conversion
35-1/16”
(891mm)
32-1/16”
(814mm)
10-5/16"
(254mm)
Regency® L900 Direct Vent Gas Fireplace 11
3"
(76mm)
from NG to LP" section for instructions.
INSTALLATION
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.
INSTALLATION
TOP STANDOFF ASSEMBLY
The top standoffs are shipped in a fl at position and must be folded into shape and attached.
1) Remove the standoffs from the fi replace
top.
2) Take each standoff and bend into the correct
shape. Bend up at the bend lines until the screw holes in the standoff and the pre­punched screw holes on the fi replace top line up.
3) Attach the standoff securely to the top
with 2 screws per standoff (on opposite corners).
SIDE NAILING STRIPS
The side nailing strips come attached to the unit. There are 3 plates, one on the top and bottom that can be folded out as required.
Side Nailing Strips shown folded out.
FINISHING TEMPLATE
In order to maintain a clean face; the L900 allows for a 1/8” in overlap of fi nishing material, such as rock or tile, on both the left and right hand sides of the unit (top and bottom sides do not allow for an overlap), this overlap must not be exceeded or the glass door will no longer open properly.
Non-combustible wall board is installed up to the fl anges on all sides of the unit. When installing any additional facing material use the Finishing Template (included with the unit) to ensure that the fi nishing material does not exceed the allowable overlap.
The Finishing Template uses two magnets to attach itself to the fl ange on the left or right side of the unit (see diagram below). Install the facing material up to the outside edge (when facing the unit) of the fi nishing template. This template may be discarded after the facing material has been installed.
12
Regency® L900 Direct Vent Gas Fireplace
INSTALLATION
VENTING
INTRODUCTION
The L900 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
VENT RESTRICTOR
POSITION
Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the instructions below;
1) Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
Latch Location
Latch
b. Swing the door out from the top and release
the hinges on the left and right side of the door by lifting them up.
Screws for plugging the holes. (all holes must be plugged with a screw).
Screw holes for fi xing the restrictor plate.
Factory Set Vent Restrictor Setting
(no adjustment required)
INSTALLATION
The Vent Restrictor plate is located on the inside top of the fi rebox.
Vent Restrictor Plate
Hinge
Door
2) Remove the screws that hold the vent restric-
tor plate in place.
3) Adjust the vent restrictor plate to the required
vent restrictor position as per the diagrams shown.
4) Once the vent restrictor plate is in the required
position, secure with screws.
Regency® L900 Direct Vent Gas Fireplace 13
INSTALLATION
INSTALLATION
EXTERIOR VENT TERMINATION REQUIREMENTS
(min. 12"/30cm)
A= Clearance above grade, B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(min. 12"/30cm) D= Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal
(min. 33"/84cm) check with local code.
E= Clearance to unventilated soffi t (min. 33"/84cm)
= Clearance to outside corner: with AstroCap
F G= Clearance to inside corner: with AstroCap Te rmination Cap (min. 18") H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator.
= Clearance to ser
J K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance * L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m) #3' (91cm) above if within 10' (3m) horizontally. M= Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.1m) N= Clearance under veranda, porch, deck, or balcony *(min. 33"/84cm)
Note:
- Excluding direct vent or non-condensing appliances, a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family
- Only permitted if v
- If the vent termination is accessible, a certifi e d guard shall be installed. * As specifi ed in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances. # In accordance with the current ANSI Z223.1/NFPA 54, Natioinal Fuel Gas Code.
eranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.
veranda, porch, deck, or balcony
Termination Cap (min. 13")
ice regulator vent outlet *(min. 36"/90cm)
v
dwellings and serves both dwellings.
*
(12"/30cm) #(9"/23cm)
14
Regency® L900 Direct Vent Gas Fireplace
VENTING ARRANGEMENTS
INSTALLATION
HORIZONTAL TERMINATION (FLEX)
Regency® Direct Vent System
These venting systems, in combination with the L900, have been tested and listed as a direct vent system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the L900 using a fl exible vent.
FPI Kit # Length Contains:
#946-618 6 Feet 1) 8” fl exible liner (Kit length)
#946-616 10 Feet
2) 5” fl exible liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
10) vinyl siding standoff
Vinyl Siding
Standoff
Wall Thimble
(Mandatory in all
Horizontal Terminations)
AstroCap XL
Vent Guard - if required*
(Part #946-506/P)
TM
Termination Cap
(Part #946-623/P)
INSTALLATION
5” dia. flue pipe
8” dia.
Flue pipe
spring spacer
* A Vent Guard is required when the AstroCap
is installed above grade at 7 feet or lower.
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from FPI may be used for Flex installations.
3) Horizontal vent must be supported every 3 feet.
4) A wall thimble is mandatory for all horizontal terminations due to high temperatures.
Regency® L900 Direct Vent Gas Fireplace 15
INSTALLATION
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as gal­vanized fi nish.
INSTALLATION
The minimum components required for a basic horizontal termination are:
1 AstroCap XL 1 90o Elbow 1 Rigid Pipe Adaptor 1 Wall Thimble 1 Length of pipe to suit wall thickness
The minimum components required for a basic vertical termination are:
1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
o
90 Elbow
24”
Pipe
Length
Rigid Pipe
Adapter
(770-994)
Vinyl Siding
Standoff (Optional)
Horizontal Terminations)
Adj.Pipe Length
11" - 14-5/8"
(Part #946-623/P)
Wall Thimble
(Mandatory in all
Vent Guard - if required*
(Part #946-506/P)
AstroCap XL
Termination Cap
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
WARNING:
Alternate
Horizontal Termination
Caps
Part # 5DT-ST14 (14") Part # 5DT-ST36 (36")
The FPI AstroCap XL AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
16
TM
is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS and Selkirk Direct-Temp.
Do not combine venting components from different venting systems.
Use of the the AstroCap XLTM is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS and Selkirk Direct­Temp systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
* A Vent Guard is required when the AstroCap
is installed above grade at 7 feet or lower.
IMPORTANT NOTE
• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
• Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Regency® L900 Direct Vent Gas Fireplace
INSTALLATION
5” X 8” RIGID PIPE CROSS REFERENCE CHART
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
Description
Simpson
Direct Vent Pro
®
Simpson
Direct Vent GS
Discontinued
Selkirk
®
Direct-Temp™
6” Pipe Length, Galvanized 58DVA-06 1208 5DT-6 5D6
6” Pipe Length, Black 58DVA-06B 1208B 5DT-6B 5D6B
9” Pipe Length, Galvanized 58DVA-09 1207 5DT-9 N/A
9” Pipe Length, Black 58DVA-09B 1207B 5DT-9B N/A
12” Pipe Length, Galvanized 58DVA-12 1206 5DT-12 5D12
12” Pipe Length, Black 58DVA-12B 1206B 5DT-12B 5D12B
18” Pipe Length, Galvanized 58DVA-18 58DVA-18 5DT-18 5D18
18” Pipe Length, Black
58DVA-18B - N/A from FPI 58DVA-18B - N/A from FPI
5DT-18B 5D18B
24” Pipe Length, Galvanized 58DVA-24 1204 5DT-24 5D24
24” Pipe Length, Black 58DVA-24B 1204B 5DT-24B 5D24B
36” Pipe Length, Galvanized 58DVA-36 1203 5DT-36 5D36
36” Pipe Length, Black 58DVA-36B 1203B 5DT-36B 5D36B
48” Pipe Length, Galvanized 58DVA-48 1202 5DT-48 5D48
48” Pipe Length, Black 58DVA-48B 1202B 5DT-48B 5D48B
60” Pipe Length, Galvanized 58DVA-60 58DVA-60 N/A N/A
60” Pipe Length, Black
58DVA-60B - N/A from FPI 58DVA-60B - N/A from FPI
N/A N/A
Metal-Fab
Sure Seal
®
INSTALLATION
Adjustable Length 3”-10”, Galvanized N/A N/A N/A 5DAL
Adjustable Length 3”-10”, Black N/A N/A N/A 5DALB
Adjustable Length 11”-14”, Galvanized
Adjustable Length 11”-14”, Black
Adjustable Length 17”-24”, Galvanized
Adjustable Length 17”-24”, Black
Extension Pipe 8-1/2”, Galvanized
Disc - See 58DV-08A Disc - See 58DV-08A
Disc - See 58DV-08AB Disc - See 58DV-08AB
Disc - See 58DV-16A Disc - See 58DV-16A
Disc - See 58DV-16AB Disc - See 58DV-16AB
58DVA-08A - N/A from FPI 58DVA-08A - N/A from FPI
5DT-AJ N/A
5DT-AJB N/A
N/A N/A
N/A N/A
N/A N/A
Extension Pipe 8-1/2”, Black 58DVA-08AB 58DVA-08AB N/A N/A
Extension Pipe 16”, Galvanized
58DVA-16A - N/A from FPI 58DVA-16A - N/A from FPI
N/A N/A
Extension Pipe 16”, Black 58DVA-16AB 58DVA-16AB N/A N/A
45º Elbow, Galvanized 58DVA-E45 1245 5DT-EL45 N/A
45º Elbow, Black 58DVA-E45B 1245B 5DT-EL45B N/A
45º Elbow, Swivel, Galvanized Disc - See 58DVA-E45 1245G N/A 5D45L
45º Elbow, Swivel, Black Disc - See 58DVA-E45B 1245BG N/A 5D45LB
90º Elbow, Galvanized 58DVA-E90 58DVA-E90 5DT-EL90S N/A
90º Elbow, Black 58DVA-E90B 58DVA-E90B 5DT-EL90SB N/A
90º Elbow, Swivel, Galvanized
90º Elbow, Swivel, Black
90º Starter Elbow, Swivel, Galvanized*
Adaptor*
Disc - See 58DVA-E90 Disc - See 58DVA-E90
Disc - See 58DVA-E90B Disc - See 58DVA-E90B
N/A N/A N/A 5D90A
N/A N/A N/A 5DDA
N/A 5D90L
N/A 5D90LB
Ceiling Support 58DVA-DC 1240 5DT-CS 5DSP
Cathedral Support Box 58DVA-CS 1241 5DT-CSS 5DRS
Wall Support/Band 58DVA-WS 1288 5DT-WS/B 5DWS
Offset Support
58DVA-ES - N/A from FPI
N/A 5DT-OS N/A
Wall Thimble, Black 58DVA-WT 1247 5DT-WT 5DWT
Wall Thimble Support Box/Ceiling Support
58DVA-DC - N/A from FPI
N/A N/A N/A
Firestop Spacer 58DVA-FS 1263 5DT-FS 5DFS
Trim Plate, Black 58DAV-WFS 1242 5DT-TP 5DCP
Regency® L900 Direct Vent Gas Fireplace 17