Regency U41, I41 Owner's Manual

Page 1
Owners &
Installation
U41/I41 GAS INSERT
ZERO CLEARANCE KIT
KIT # 660-900
Manual
Tested by: Warnock Hersey:
PLEASE KEEP THESE INSTRUCTIONS FOR
FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam­age. Refer to this manual. For assistance or additional information consult an authorized installer, serv­ice agency or the gas supplier.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appli­ance.
Installation and service must be per­formed by an authorized installer, service agency or the gas supplier.
FPI Fireplace Products International Ltd. 6988 Venture St., Delta, B.C. Canada, V4G 1H4
Australian Heating Distributors 10/46 James St., Guildford, Western Australia 6055
908-427 01/16/04
FOR YOUR SAFETY What to do if you smell gas:
- Do not try to light any appliance
- Do not touch any electri­cal switch: do not use any phone in your building.
- Immediately call your gas supplier from a neigh­bour's phone. Follow the gas supplier's instructions.
- If you cannot reach your gas supplier, call the fire department.
Masport Head Office - Australia 54 Boundary Rd. Braeside P.O. Box 553 Mordialloc 3195 Ph. (03) 9586-7777 Fax. (03) 9586-2980
Masport Head Office - New Zealand 1-37 Mt Wellington Hwy.Panmure, P.O. Box 14349 Auckland 6. Ph. (9) 570-9009 Fax. (9) 527-1294
Page 2
LISTINGS AND CODE APPROVALS
This gas component has been tested in accordance with National Safety Standards, and has been certified by Warnock Hersey for installation and operation in the United States, Canada, Australia, and New Zealand as described in these Installation and Operating Instructions.
Check with your local building code agency before you begin your installation to ensure compliance with local codes, including the need for "permits" and follow-up inspections. If any problems are encountered regarding code approvals, or if you wish clarification on any of the instructions contained here, contact your local dealer.
U41/I41 Zero Clearance Kit Specifications
Using Kit# 660-900 you can convert the Gas Insert models U41 and I41 into highly efficient heat producing Zero Clearance Fireplaces.
REQUIRED PARTS
Included with Kit:
1 660-908 Main Body Assembly 1 660-906 Front Base Assembly
Sold Separately:
1 660-911 Zero Clearance Faceplate
44-3/8"(1127mm) W x 33-5/16"(846mm) H
2
GENERAL INFORMATION
This kit consists of factory built parts that require minimal assembly to form the Zero Clearance enclosure for the U41/I41 Gas Insert. The enclosure can then be fixed into a framed combustible con­struction, and a standard "B-vent" installed on the assembly for the required venting. The insert can be installed later.
The faceplate will normally overlap on top of the finished wall. The base of the Zero Clearance Kit can be installed directly on carpeting, tile or any flooring material; however, the hearth if installed in front of the unit requires special protection as described in the "Hearth" section on page 4.
U41/I41 Gas Insert Zero Clearance Kit
Page 3
INSTALLATION
CLEARANCES TO COMBUSTIBLES
The clearances for the Zero Clearance Kit are 0" to combustibles (back, side and floor) but when planning your installation review the clearances required for the Insert (see below) after it is installed in the Zero Clearance Kit.
The Zero Clearance Kit must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or raised up on a platform to enhance its visual impact.
Clearances to Combustibles
for U41/I41 Insert
From Unit
Sides A 9.5" / 241 mm Drop Ceiling B 35" / 890 mm Mantel C(My) 12.5 / 320 mm
From Surround Sides D 2" / 50 mm Drop Ceiling E 25.5" / 650 mm Mantel F 3" / 75 mm
Mantel Depth G(Mx) 7.5" / 190 mm Min. Alcove Width J 48" / 1120 mm Facing (Mantel Leg)
Side* K 1" / 25 mm Top L 1" / 25 mm
*Max. width of 1"(25mm) at 1"(25mm) from surround, calculate depth at 45o as shown in the diagram.
G
F
C
A
D
H
B
E
I
J
U41/I41 Gas Insert Zero Clearance Kit
Top View
Combustible Mantel Clearances
Depth (MX) Clearance (MY) (inches) (mm) (inches) (mm)
0" to 5.5" 0mm to 140mm 11" 280mm
6.0" 153mm 11-3/8" 289mm
6.5" 165mm 11-3/4" 299mm
7.0" 178mm 12-1/4" 312mm
7.5" 191mm 12-1/2" 318mm
8.0" 203mm 12-5/8" 321mm
8.5" 216mm 12-3/4" 324mm
9.0" 229mm 12-7/8" 327mm
9.5" 242mm 13" 330mm
Note: A non-combustible mantel may be installed at a lower
height if the framing is made of metal studs covered with a non-combustible board.
3
Page 4
INSTALLATION
LOCATING YOUR U41/I41 FIREPLACE
Due to high temperatures the Insert should be located out of traffic and away from furniture and draperies. Provide a minimum of 48" (1220 mm) front clearance to the unit.
This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further require­ments, check local codes before installation.
This unit is not approved for installation into a mobile home.
a) Cross Corner d) Island b) Room Divider e) Flush with Wall c) Flat on wall f) Flat on Wall Corner
HEARTH
A hearth is not mandatory, but is recommended for aesthetics and for added safety, and if a hearth is installed follow the requirements listed below. We recommend a non-combustible hearth which comes out a minimum of 12" (305 mm) in front of this appliance. The Zero Clearance Kit allows for a hearth up to 3" (75 mm) thick above the base to be installed in front of the unit, the ventilation holes must
not be blocked. Note: if the hearth is built up, the faceplates sides will need to be field trimmed to fit, the insulation behind the faceplate must not be removed.
Non-Combustible Hearth Material
a) non-combustible floor board meeting ASTM E-136 or E-108 or CAN
4-S114 or the equivalent, and offering a thermal resistance (k factor) of 0.45 or greater.
b) suitable materials include but are not limited to: Wonderboard,
Durock, Micor, Hardibacker, Capeboard, etc.
c) 1"(25mm) thickness of brick.
Non-combustible Hearth
Height (y) Depth (x) (inches) (mm) (inches) (mm)
3" 76mm 21-3/4" 553mm 2-5/8" 67mm 21" 534mm 2-1/4" 57mm 20" 508mm 1-7/8" 48mm 19" 483mm 1-1/2" 38mm 18" 457mm 1-1/4" 32mm 17" 432mm 1" 26mm 16" 407mm 7/8" 22mm 15" 381mm 5/8" 16mm 13" 330mm 1/4" 7mm 11" 280mm 0" 0m m 9" 229mm
4
U41/I41 Gas Insert Zero Clearance Kit
Page 5
INSTALLATION
FRAMING
1) The trim kit allows for 1/2" (13 mm) of finish facing material. The
kit may be installed directly on and/or against standard combustible building materials.
2) Frame in the enclosure for the Kit with framing material. The framed opening for the assembled kit is 33-1/2" (850 mm) high x 30-1/4" (769 mm) wide x 16" (407mm) deep. See diagram.
3) For exterior walls vapour barrier and insulate the enclosure to the same degree as the rest of the house, or according to local installation codes. In colder climates, if the heater is to be installed against an exterior wall or chase, insulate the exterior walls according to local installation codes.
4) Extend the vent chase to a minimum ceiling height of 79" (2007 mm) at the same width and depth mentioned above. Keep this area above the unit clear of combustible construction except for the framing header.
ZERO CLEARANCE KIT ASSEMBLY
Warning: Combustible materials must not extend inside the stand-offs on the side, top and rear supports. For safety reasons do not modify or alter any components of the 660-900 Kit.
1) Slide the Front Base assembly into position on the Main body
assembly as shown in the diagram. Align the screw holes with the 3 holes on the front side supports. Align the nail holes on the Front Base assembly base with the base of the Main body assembly.
2) Use the 3 screws (on each side) to tighten the Main body and Front Base assembly. Base must be at same elevation as the main body assembly.
3) Nail the Zero Clearance Kit to the framing, there are 6 predrilled holes in the front face of the kit (3 per side) and 3 predrilled holes in the Front Base assembly. It is recommended that the Front Base assembly and Main body base be nailed to the floor.
U41/I41 Gas Insert Zero Clearance Kit
5
Page 6
INSTALLATION
VENTING
This fireplace must be vented with a 4"(102mm) diameter Class “B” vent (not supplied). The installation of the venting system must conform and be in accordance with the natural gas installation code CAN/CGA - B149(Canada), ANSI Z223.1 (U.S.A.), AG 601 (Australia), NZS 5261 (New Zealand) and any applicable national or local codes. Minimum chimney height from base of fireplace must be at least 12 feet (3.6 M).
o
Use a maximum of two offsets; four 45 at least 1/4" (6.4 mm) rise per 12" (305mm) of run. Horizontal runs should not exceed the vertical rise. Keep horizontal runs to a minimum.
elbows, or two 90o elbows for example. Slope horizontal pipe
standard through the wall in the wall multi-storey
Variable Chimney Routes
Flue Vent Termination:
There must be at least 3 ft.(0.9m) of chimney above the roof level. Stack the pipe onto your finish support to a minimum height of 3 ft.(0.9m) above the roof penetration, or 2 ft.(0.6 m) above any point within 10 ft. (3 m) measured horizontally.
In North America, flue systems with vent caps approved by the Underwriters Laboratories and marked "WIND" may terminate at levels lower than the 10 ft. - 2 ft. rule. See chimney manufacturer's instructions for further information.
installation
NOTE: Cold Climate Installation
Do not install against a non-insulated wall or in a chase.
6
U41/I41 Gas Insert Zero Clearance Kit
Page 7
INSTALLATION
OPTIONAL OUTSIDE COMBUSTION AIR SUPPLY INSTALLATION
A 4" (100 mm) dia. aluminum flex pipe or equivalent may be installed from the outside (with a proper exterior cover) to the Zero Clearance cabinet. There are outside air knock-out holes provided on three sides of the kit. Use only the one that is most suitable for your installation. This will provide adequate outside combustion air supply to the heater.
GAS SUPPLY LINE
An authorised service person should install the gas line in accordance with all local building codes. If codes permit, flex gas line or coiled copper tubing may be used as gas supply line. The suggested way to install the gas supply line is as follows: run 1/2" (9.5 mm) NPT gas line to the left side of the framed opening.
Specifications U41 I41
Natural Gas Propane Natural Gas Propane Min. Inlet Gas Pressure 5.0" w.c. 11.0" w.c. 1.25 kPa 2.75 kPa BTU Input Rating 38,000 BTU/hr 38,000 BTU/hr 42,000 BTU/hr 38,000 BTU/hr
Install an electrical outlet box in the lower left rear corner, no higher than 4-1/2" (114 mm) above the bottom and connect 120 VAC (240V in Australia & New Zealand) to the receptacle. The heater fan power cord will be plugged into this outlet box, or into any receptacle near the appliance.
Install finished facing surface of 1/2"(13mm) thickness on framing. Drywall 1/2" (13 mm) thick can extend flush with the appliance on all three sides of the front face. The height at which the mantel must be installed above the top louver depends on the depth of the mantel. If the mantel is to be painted, use a heat resistant paint to prevent discolouration.
Faceplate and trim installation instructions are in the U41/I41 Insert manual. NOTE: the top faceplate assembly has insulation installed for safety reasons and must not be removed.
U41/I41 Gas Insert Zero Clearance Kit
WIRING
FINISHED FACING NOTES
7
Page 8
© Copyright 2004, FPI Fireplace Products International Ltd. All rights reserved.