This Equipment has been tested and found to comply with the limits for a class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency
ENGLISH
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment o and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Warning :
Use only shielded signal cables to connect I/O devices to this equipment.
You are cautioned that changes or modi cations not expressly approved by the
party responsible for compliance could void your authority to operate the
equipment.
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit di erent fromwhich
the receiver is connected to.
• Consult the dealer or an experienced radio/TV technician for help.
Getting Started 4
Quick Installation Guide (QIG) 5
Installing Software and Driver 6
Installing Hardware 8
Additional Features 8
Loading the lm/slides into the Holders 9
One Button Scan 11
How to Scan Slides 12
STEP 1 - Aquire Driver 12
STEP 2- Select Film Type 12
STEP 3 - Optional Prescan 12
STEP 4 - Set Scan Settings 13
STEP 5 - Set Scan Preferences 14
STEP 6 - Scan 17
STEP 7 - Exit 17
User Interface 18
I Main Window Area 18
II Preview Window Area 20
III Scan Setting Area 25
Technical Support 26
ENGLISH
2
3
5
4
Check the package content before getting started.
•
•
•
•
•
•
•
•
•
GETTING STARTED
•
•
•
•
For Quick Installation please refer to Quick Installation Guide. (Ref. Pg. 9)
ENGLISH
Package Contents
NOTE:
GENERAL GUIDANCE:
4
GETTING STARTED
Important! Save the original box, receipt and packing material for future
shipping needs.
• Slide Scanner.
• Film Holder (Where Applicable)
• Power Adapter [FAIRWAY Model No. : WRG 15F-120A]
Warning! Using any other power adapter may severely damage the scanner and will void the product warranty.
• Power Cord.
• USB 2.0 Cable.
• CyberView X5 Driver.
• Application software DVD.
• Printed User’s Manual.
• Application software means the imaging software such as Adobe®
Photoshop® Elements, this is subject to change without notice.
• Only use the supplied USB-Cable. Connect the computer to the scanner
directly using the USB 2.0 cable.
• Do not use a hub or extension cable. Only use the USB ports on the rear
of desktop computers.
• If there are any other devices (multifunction device, printers, scanners,
webcam) connected to the computer through USB, disconnect them.
• A minimum of 1GB RAM (Win/Mac) is required.
Operating Ambient Temperature Range
50º to 104ºF (10º to 40ºC)
Note: Do not turn on the scanner unless it is within this range. If the
scanner has been stored or transported outside of this range,
allow it to return
to within this range before turning it on.
Operating Ambient Humidity Range 15% to 76% rela-
tive
humidity (non-condensing)
Note: If the scanner is stored or to be transported in cold temperature
and then brought into a warm / humid environment
condensation may occur.
This device is designed solely for private use and is not intended for commercialuse. The warranty is reduced from 2 years to 1 year if errors or defects arising from inappropriate use, improper operation or stress occur. The guarantee
period of the device for private use is 2 years or 20,000 scans.
ENGLISH
5
7
6
INSTALLING SOFTWARE AND DRIVER
QUICK INSTALLATION GUIDE QIG
for PC (Windows) User
WINDOWS SYSTEMS INSTALLATION DURING DRIVER INSTALLATION A WARNING
DIALOGUE BOX MAY APPEAR, IF THIS IS THE CASE PLEASE SELECT “INSTALL THIS
DRIVER ANYWAYS”.
ENGLISH
You may install the scanner driver directly if you have already installed TWAIN
compliant application software in your computer. Mac users can use iPhoto for
editing.
Notice:
NOTE: Not all PC’s will display the found new hardware window, some will install
in the background
QUICK INSTALLATION GUIDE QIG
Be sure to install the Application Software BEFORE installing the scanner
driver CyberView X 5.0.
1. In “Found New Hardware Wizard” window, select “Search automatically
or Browse computer for driver software.”
2. In “Completing the Found New Hardware Wizard” window, click
“Finish”.
TWAIN scanner plug-in Installation Guide for Adobe Photoshop Elements 9
and newer versions
The TWAIN scanner plug-in is no longer installed with Photoshop Elements 9.
In order to be able to import scanner device through Adobe Photoshop elements, please follow below instructions after installing Adobe Photoshop
Elements 9 to nd where and how to install the TWAIN component which was
previously installed with the application for versions earlier than Photoshop
Elements 9.
Important: Do not move plug-ins from previous versions of Photoshop Elements
into the Photoshop Elements 9 > Plug-Ins folder, or set the Photoshop Elements
8 (or earlier) > Plug-In folder as the Additional Plug-Ins Folder in Preferences.
Find complete information at o cial Adobe website:
http://kb2.adobe.com/cps/849/cpsid_84933.html
Macintosh
To install the legacy TWAIN plug-in for Macintosh, copy TWAIN.plugin folder
from: //Applications/Adobe Photoshop Elements 9/Optional Plug-Ins/ImportModules/
Into: //Applications/Adobe Photoshop Elements 9/Locales/<locale>/Plug-Ins/
ENGLISH
INSTALLING SOFTWARE AND DRIVER
Before Installing the Scanner Driver...
If you choose to use the provided application for image editing, install the application software (ex: Adobe® Photoshop® Elements) by inserting the application CD into the computer’s CD/DVD drive. Follow the instructions that will be
displayed in a window that opens automatically.
Installing Scanner Driver
a. Insert insert driver CD into the computer CD/DVD drive and explore the
contents.
b. Double click the ”CyberView X 5.0” icon to begin the installation process.
Follow the onscreen prompts to complete the installation process.
NOTE:Make sure the scanner is NOT connected to the computer during the Cyber-
View X 5.0 driver installation.
c. Restart computer once the installation process is complete.
Please Note:
another USB Flatbed scanner or All-in-one Scan/Copier/Printer device installed, it may be
necessary for you to disconnect the other scanner from the USB port for the Film scanner to
work properly,
When installing your new scanner onto a Windows system that already has
6
Windows
To install the legacy TWAIN plug-in for Windows, copy twain_32.8ba from:
C:\Program Files\Adobe\Photoshop Elements 9\Optional Plug-Ins\ImportExport\
Into: C:\Program Files\Adobe\Photoshop Elements 9\Locales\<locale>\Plug-Ins\
Import-Export\
64-bit Windows
Photoshop Elements 9 is a 32-bit application. When installed on a 64-bit version
of Windows the path is slightly modi ed.
To install the legacy TWAIN plug-in for Windows, copy twain_32.8ba from:
C:\Program Files (x86)\Adobe\Photoshop Elements 9\Optional Plug-Ins\ImportExport\
Into: C:\Program Files (x86)\Adobe\Photoshop Elements 9\Locales\<locale>\
Plug-Ins\Import-Export\
7
9
8
Installing Hardware
ENGLISH
CrystalScan 7200
ProScan 7200
a. Connect the slide scanner to a power source.
1. Locate the power switch on the lower left side of the scanner. Make
sure the scanner is TURNED OFF.
2. Plug the AC adapter into an AC power source
FIRST before plugging it into the scanner.
3. Attach the USB cable to the computer using the stadard USB adapter
end. Attach the USB adapter end of the cable to back panel of the
scanner.
Additional features
1. Lid.
2. Slide Holder
3. Film Deck
4. One Button Scan
5. Release Switch
6. Viewing Window.
1. Scanner
2. Slide holder
3. Film Holder
4. One Button Scan
5. Back of the unit
6. Viewing Window
1. DC In
2. USB Port
3. Power Switch
To Scan Film (Film & Mounted Slides) CrystalScan 7200
Mounted Slides
1. Open Scanner Lid (1).
2. Release the Slide/Film Holder (5) put in slide “Shiny side up” then close
slide holder.
3. Close Scanner Lid (1) (optional).
4. Ready to scan.
Filmstrips
1. Open the scanner lid (1).
2. Release the Slide Holder (5).
3. Position the lm that you wish to scan in the center of the viewing
window (6).
4. Push down the lm frame and close the slide holder.
5. Ready to scan.
ProScan7200
ENGLISH
To Scan Mounted Slides
1. Mounted Slides
1-1. Load the mounted slides into the slide holder, shiny side facing upward
1-2. Insert the slide holder into the scanner with the arrow facing upwards
1-3. Insert to holder into the scanner from the left or the right side
8
9
11
10
ProScan 7200 - Scanning Slides (Continued....)
Please Note: improper insertion will
cut o the top of the image.
One Button Scan
1. Open the CyberView (see page 12 to acquire the CyberView driver program)
2. Con gure Scan Settings (see Page 13)
3. Select the Scan to directory, le format (TIF or JPG, once con gured, Press the
scanner button ( ) to begin scanning.
ENGLISH
ENGLISH
To Scan Negative Film Strips
2-1. Load the negative into the holder making sure to align the lm frames with the
frames on the holder, and with the shiny side facing upward
2-2 Close the lm holder
2-3. Insert the lm holder into the scanner from the left or right side, with the arrow
facing upwards
CrystalScan 7200
One Touch Button
NOTE:
If you do not open CyberViewX 5.0 FIRST, the scan button will not function.
ProScan 7200
One Touch Button
10
11
13
12
STEP 1 – Acquire Driver
HOW TO SCAN SLIDES
(For PC User)
Open CyberView X 5 from Start – All Programs –CyberView
(For MAC User)
ENGLISH
Open Macintosh Hard drive – Applications –CyberView
STEP 2 – Select Film Type
Select the lm type to be scanned - Positive, Negative or B&W (Black and White).
Pre-Scanning should be used to manually adjust color/edit settings for each slide
before doing the nal scan. It’s possible to set di erent settings for each slide to
be scanned.
12
HOW TO SCAN SLIDES
STEP 3 – Optional Prescan
Select the “Prescan Current Frame“ to prescan the slide currently loaded into
the scanner or “Prescan...“ to prescan slide or slides at speci c positions in the
magazine.
STEP 4 – Set Scan Settings
a. Resolution
The default scanning resolution is 1000dpi, additional resolution options
are listed below.
Notice: Higher scanning resolutions result in greater scanning time and hardisk
space requirements.
b. Color Depth
Choose between 8 and 16bit. A higher color depth setting will result in
a larger range of colors in the nal scanned image.
The Film Scanner colour depth is 48 bit true color. The scanning software has
the capability of selecting 8 bit color mode or 16 bit color mode when scanning,
This will produce 24 or 48 bit color images, 8 bits or 16 bits per Red, Green and
Blue color channels.
Example:
8 bit mode = 8 Red, 8 Green, and 8 Blue for a total of 24 bit color
16 bit mode = 16 Red, 16 Green, and 16 Blue for a total of 48 bit color
NOTE: Make sure there is enough space available
on the computer when changing the Scanning
Resolution. A high scanning resolution results in
large les that may prove di cult to save.
Color image le size of di erent resolutions
and color depths:
Scanning
Resolution
300dpi8 bit24-bit~350Kb
600dpi8 bit24-bit ~1MB
1800dpi8 bit24-bit ~12MB
3600dpi8 bit24-bit ~52MB
7200dpi8 bit48-bit~208MB
Scans include Auto Balance and Digtal Noise
Reduction on:
Processor: AMD 9650 Quad-Core 2.3GHz
Memory: 2GB
System type: Vista 64 bit
Scan Mode – Normal mode produces a scan in jpeg format while Quality produces a non-compressed, “loss-less” TIFF image.
Color
Depth
(by RGB
channel)
Color
Mode
File Size
TIFF
(no compres-
sion)
ENGLISH
13
15
14
STEP 5 – Set Scan Preferences
Select Scan - Preference - Film Type - Scan Setting
“Color Depth“ – Default color depth while scanning.
“Scan Mode“ – Default scan mode while scanning.
Con guring Scan Preferences
1. Select Browse and choose the designated folder to save the scanned
image to
2. Enter the le name.
Set Scan Preferences (Continued...)
4. Options - Use Film Index: Use the number assigned to the slide based on it’s
position in the cartridge.
User De ned Start Number: Enter a speci c start number
5. Choose the le type , “TIF” or “JPG”. (TIF uncompressed or JPG CompressedChoose image quality for JPEG. (20-100) 100 o ers the least amount of compression
Advanced Setting - PC Users
Advanced Setting - Intel Mac Users
ENGLISH
3. Trailing Index after Base File Name Digits: De nes the length of the
le name and numbering sequence up to 6 digits Example image1 or
image000001.
14
”Auto Exposure” - Attempts to nd the correct exposure to get the widest range of whites and blacks while putting the middle grays at around
the middle of the data range.
”Auto Balance” - Using the image histogram to balance RGB channels. It
estimates images’ color cast and adjust the images accordingly
“Auto Contrast” - The scanner software analyzes the data and automatically adjusts the Setting for the White and Black Points.
”Digital Noise Reduction” – Applies a lter, Reducing the lm grain.
15
17
ENGLISH
16
Default Scanning Area
Adjust the scanning size as well as adjust the “Scan O set” setting to move
the image position of slide.
Auto Color takes the guesswork out of the scanning process to streamline the
work ow and achieve the best results. Proprietary color enhancement
technology is applied to scanned images to provide the most accurate color
adjustment, resulting in vibrant images with optimal brightness, contrast and
saturation.
ENGLISH
STEP 6 – Scan
Scan - Scan- Scan Current Frame
CS7200 - Windows and Mac PowerPC Users ONLY- Digital ICE, ROC, GEM
(for additional information, please see included Digital ICE
Intel Based Mac Users - Magic Touch / Auto Color
Enable / disable Magic Touch and Auto Color adjustment to scans.
Magic Touch is a powerful dust and scratch removal technology that does away
with the hassle of learning complex and tedious software techniques. Being
hardware-based, it works seamlessly with the scanning process to ensure the
best possible results when bringing images into the computer. Dust, scratches
and other aws are intelligently detected and eliminated, restoring the image to
its original beauty.
Scanning with Magic Touch requires longer scanning times, the feature is turned
o by default.
3
Users guide)
16
This begins the scan to le process
All scaned images will be saved to the directory location set previously,
the factory default locations are:
Windows: C:\Users\[YOUR NAME\Documents;
MAC: Mac HD\Users\[YOUR NAME]\Pictures\Cyberview Images),
STEP 7 – Exit
Select “Scan > Exit” to close the driver. Scanned image les can be open/edited
with any image editing software.
If using the supplied image editor, for help with this application see the users Help
NOTE:
from within the application or browse the supplied DVD for the help documentation.
17
19
18
USER INTERFACE
USER INTERFACE
There are four major parts of theCyberView X 5 user interface:
I. Main Window Area
II. Preview Window Area [Fixed Window]
III. Scan Setting Area [Floating Window]
[Fixed Windows]
I. Main Window Area [Fixed Windows]
ENGLISH
ENGLISH
Menu Commands - Scan
Prescan - Prescan Current Frame: Pre-scan the existing slide.
Scan - Scan Current Frame > Scan the current slide.
Menu Commands - Preview
Zoom, Rotate & Flip features.
Revert
Discards all modi cations and restores the image back to the original
state.
Preference - See Scan Setting (See Page 13)
Exit
Closes the CyberView X5 user interface.
There is a message pop-up “Quit the application prompts to save documents?“ click “Yes“ to save , “No“ to discard the current
settings or “Cancel“ to return to Cyber View X.
18
19
21
20
Menu Commands - Image Adjustment
ENGLISH
a. Image Adjustment
1. Variations: Generates di erent views of image with options to make changes
to highlights, midtones, etc.
2. Color Balance
To adjust the brightness, contrast, saturation, and color (CMY or RGB)
of the image. Comparisons between before and after adjusted images
are shown for reference.
ENGLISH
20
Example:
Balance” window to adjust the image by selecting the slider in the center and moving it to
the right. The image’s “After” view becomes lighter. Select “OK” to accept the changes which
will be sent to the scanning hardware. This can also be used to adjust each of the functions
in “Color Balance” by contrast, saturation and speci c color ranges of cyan, magenta and
yellow.
If a previewed image appears too dark, use the “Brightness” slider in the “Color
21
23
22
3. Curves and Levels
•
•
Menu Commands - Window
ENGLISH
Example:
Input slider in the Curves and Levels window can be made to correct the image. Selecting
the Gray slider in the center and moving it to the left will result in changes in the “After”
view resulting in a lighter image. Once the adjusted image is acceptble select “OK” to send
changes to the scanning hardware. The same method can also be used to adjust each color
channel independently, using the channel drop down menu “RGB = All colors” R = Red, G =
Green, and B = Blue.
Adjust image settings by moving Curve and Levels settings.
Comparison between before and after adjustment is displayed for
reference.
When the previewed image appears to be too dark, adjustments with the
1. Exposure Setting: To adjust the exposure time (R, G, B) press ”Reset” to restore to
the default setting.
Menu Commands - Help
• Update: Firmware: Upgrade the rmware version, select the path where the le of
rmware has been saved. (These les may be downloaded from our website)
• About: Displays system information (including operation system, CPU), product
information (including product name, model name, hardware version, rmware version, software version, device information including interface and optical
resolution).
Function Bar Diagram
Please select your lm type
and brand from the toolbar:
Negative
Positive (also
known as Slide)
Black and White
II. Preview Window Area [Fixed Windows]
ENGLISH
22
Prescan: Pre-scan the current lm, press drop down for more options.
Scan: Scan lm, press drop down button for more options.
Image Adjustment: Press drop down button for more options.
23
25
24
Status Line
In the lower left hand corner, the color level (RGB: red, green, blue) and
coordinates of the location [ex: I] are displayed. The zoom scale, the current slide
magazine location and how many areas selected to scan (2 or or higher indicates:
Multiple scan areas on one slide [ex: II].
I.
ENGLISH
ENGLISH
Preview the image you pre-scan, you can select the measurement unit “in“-“cm““px“ by clicking the upper-left corner.
Toolbar Diagram
Select scan area: more than one selection can be made at a time.
Zoom In: To magnify the image where the cursor is currently located.
The image will be magni ed with every click until the maximum multiple (1000%) is reached.
Zoom Out: To reduce the size of the viewed image click the Zoom Out
cursor to the desired area, the image will reduce by half with every click
until the lowest multiple (25%) is reached.
Rotate 90 Left: To rotate the image counter clockwise 90 degrees.
Rotate 90 Right: To rotate the image clockwise 90 degrees.
Flip Horizontal: To Flip the image 180 degrees horizontally.
Flip Vertical: To Flip the image 180 degrees vertically.
II.
III. Scan Setting Area [Floating Windows]
Normal mode [ex: I] to input the basic parameter to scan (including scan
resolution, lm size, color depth).
Advanced mode [ex: II] to input the parameter of scan output, scan resolution,
and color depth
II.
I.
24
Revert: Discard all modi cations and restores the image back to
the original state in preview windows.
25
26
TECHNICAL SUPPORT
TECHNICAL SUPPORT
CyberView
For information regarding the lm scanner and CyberView driver, please visit
www.re ecta.de.
ENGLISH
Bundled application software
You can refer to the HELP function on the application menu bar or visit the software company’s website.