DISPOSAL OF MATERIALS ............................................................................................................................... 6
Partial Muting with Enable .......................................................................................................................................22
Partial Muting with Disable ......................................................................................................................................22
Override with spring return key ................................................................................................................................23
Override with pushbutton .........................................................................................................................................23
CALCULATION OF THE SAFETY DISTANCE ................................................................................................. 24
GENERAL FORMULA FOR CALCULATING THE SAFETY DISTANCE ........................................................ 24
MODELS WITH RESOLUTION 30 MM – 40 MM .............................................................................................. 25
MODELS WITH 2/3/4 BEAMS............................................................................................................................ 25
MULTIPLE SYSTEMS ........................................................................................................................................ 27
USE OF DEFLECTING MIRRORS ................................................................................................................... 28
DISTANCE FROM REFLECTING SURFACES ................................................................................................ 29
MECHANICAL ASSEMBLY AND OPTICAL ALIGNMENT ............................................................................... 30
SM - SMO MODELS ELECTRICAL CONNECTIONS ................................................................31
TEST FUNCTION ............................................................................................................................................... 34
SELECTION OF OPERATING MODES ............................................................................................................ 35
Available congurations. ..........................................................................................................................................46
TEST FUNCTION ............................................................................................................................................... 48
SELECTION OF OPERATING MODES ............................................................................................................ 49
WARNINGS ON CONNECTION CABLES ....................................................................................................... 55
TEST FUNCTION ............................................................................................................................................... 57
APPENDIX C: S MODELS WIRING SAMPLES .........................................................................57
THE TOOLBAR ................................................................................................................................................... 72
Partial Muting with Enable .......................................................................................................................................82
Partial Muting with Disable ......................................................................................................................................82
Override with spring return key ...............................................................................................................................83
PERIODIC CONTROL ....................................................................................................................................... 85
CARE AND MAINTENANCE .............................................................................................................................. 86
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
4
Introduction
INTRODUCTION
Dear customer, REER congratulates you on purchasing this product.
Refer to this manual before using SAFEGATE; keep the CD-ROM and the Quick Installation Guide in a
place easy to be found in order to be able to refer to them when needed.
PURPOSE OF THIS DOCUMENT
This manual illustrates the operation of the programmable access curtain with Muting integrate SAFEGATE
functions. It shows specically:
¾ a general description of the SAFEGATE world;¾ the characteristics of the muting function;¾ the dierent types of muting and their application;¾ the list of SAFEGATE models;¾ the mechanical installation;¾ the electrical connections;¾ the mode of operation;¾ the Muting, Override modes and their activation;¾ SAFEGATE programming through dedicated software.
PRODUCT DESCRIPTION
The SAFEGATE light curtain is an optoelectronic multi-beam safety system belonging to the category of
Type 4 electro-sensitive devices (in accordance with EN 61496-1,2), equipped with the Muting function, for
the protection of persons exposed to dangerous machines or plants.
SAFEGATE ensures a perfect integration of the Muting sensors that are connected directly to the connectors
on the safety curtain.
In the hardware conguration models (SM and SMO) the Muting logic and the operating parameters are
fully dened by the connections of the main connector.
The SMPO programmable models retain all the features of SM and SMO models allowing also the
conguration of various parameters and additional features via the SCS software (SAFEGATE Conguration
Software).
The main features of SAFEGATE are as follows:
¾ Resolution: 30 and 40 mm – 2, 3 and 4 beams.¾ Integration of the main safety functions, including self-monitoring of static outputs, EDM and Start/
Restart Interlock.
¾ Outline dimensions: 55 x 50 mm.¾ Protected height: 300 to 2200 mm.¾ Degree of protection: IP65 e IP67.¾ Operating temperature: -30 ... +55 ° C (no condensation).¾ Muting lamp and integrated curtain status indication (SMO/SMPO).
CONTENT OF THE PACKAGE
¾ SAFEGATE emitter and receiver¾ CD-ROM (Containing conguration software and this Manual)¾ Quick Installation Guide¾ Mounting accessories bag¾ Sealing caps for unused connectors
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
5
Introduction
GLOSSARY
PROTECTED HEIGHTA measure that indicates the height controlled by the curtain.
SAFETY DISTANCE
EDM
MUTING
OVERRIDE
RANGEMaximum operating distance: between emitter and receiver
RESOLUTION
START/RESTART
INTERLOCK
RESPONSE TIMETime: between interruption of the gate and disabling of outputs
LXMuting Logic with 2 mono-directional cross-sensors
L2Muting Logic with 2 mono-directional parallel sensors
TXMuting Logic with 2 bi-directional cross-sensors
T4Muting Logic with 4 bi-directional parallel sensors
SModel without Muting
SMModel with Muting and Hardware conguration on main connector
SMOSM model with integrated Muting lamp
SMPModel with Muting Programmable with SCS software
SMPOSMP model with integrated Muting lamp
Minimum distance that must exist between the protected gate and the
dangerous area
External Device Monitoring: control of external contactors switching through
the feedback input.
Function of temporary suspension of the safety function: temporary exclusion
of the safety curtain, automatically and safely carried out based on the
machine cycle.
Forced activation of OSSD outputs: during the muting cycle for material
removal
Minimum detectable object size: to ensure the arrest of the dangerous
machine
Interlock function (manual reset required): when starting or restarting the
machine
DISPOSAL OF MATERIALS
Learn the regulations for collecting electrical and electronic products in force in the country where you want
to dispose of your product.
Observe local regulations for waste disposal and do not throw away old products with normal domestic
waste.
A proper disposal of non-usable products prevents potential negative consequences for the environment
and the population.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
6
Safety
SAFETY
SIMBOLOGY
This symbol indicates an important warning for personal safety. Failure to comply with this warning
may result in high level risk for exposed personnel.
Î This symbol indicates an important warning for the proper operation of the curtain.
PRECAUTIONS
The operations indicated in this document must only be carried out by qualied personnel. Such
personnel must have the necessary requirements to be able to operate on the electronic equipment
to be installed in order to avoid any risky situation.
REER declines any liability for malfunctioning of equipment installed by unqualied sta.
Any use other than those indicated in this manual may be considered as potentially dangerous for
the installer and the machine operator.
For safety reasons, please contact your country’s safety authorities or the relevant industry
association if necessary.
For applications in the food industry, consult the manufacturer to verify compatibility between
curtain materials and chemical agents used.
The protective function of optoelectronic safety devices is not eective in cases where:
¾ The machine stopping device cannot be actuated electrically and it is not possible to stop all dangerous
machine movements immediately and at any time during the operating cycle.
¾ The hazardous condition is associated with the falling of objects from above or ejection of these from
the machine.
¾ Anomalous forms of light radiation are present (for example, use of cablelless control devices on cranes,
radiation from weld spatter, etc). In this case additional measures may be necessary to ensure that the
ESPE does not fail to danger.
Î The strict and complete observance of all the standards, indications and prohibitions set forth in this
manual is a prerequisite for its proper operation.
REER S.p.A. therefore, declines any liability in case of non-respect, even partial, of these indications.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
7
Safety
CAUTIONS BEFORE INSTALLATION
Before installing the SAFEGATE safety system, you must verify all of the conditions listed below:
The protection level (Type4, SIL3, SILCL3, PLe) of the SAFEGATE system must be compatible with
the danger level of the system to be controlled.
The safety system should only be used as a stop device and not as a device for controlling the
machine.
The machine control must be electrically actuated.
It must be possible to immediately stop any dangerous operation of the machine.
In particular, the machine stopping times must be known and, if necessary, measured.
The machine must not generate hazardous situations due to projection or fall of materials from
above; otherwise it is necessary to provide additional mechanical protections.
The minimum size of any object to be intercepted must be greater than or equal to the resolution of
the selected model.
The knowledge of the shape and size of the hazardous area allows an estimation of the width and the
height of its access area:
Compare these dimensions with the maximum working range and the height of the area guarded by
the model used.
Before placing the safety device, it is important to consider the following general guidelines:
Verify that the temperature of the environment where the system is installed is compatible with the
temperature operating parameters indicated on the product label and in the technical data.
Avoid positioning the Emitter and Receiver near intense or ashing high-intensity light sources.
Specic environmental conditions may aect the level of detection of photoelectric devices.
In environments where fog, rain, smoke or dust may be present, it is advisable to use suitable Fc
correction factors at the maximum useful values of the working range to ensure the correct operation
of the equipment. In these cases:
Pu = Pm x Fc
where Pu and Pm are respectively the working range and maximum range in metres.
Recommended Fc factors are shown in the following table.
ENVIRONMENTAL CONDITIONCORRECTION FACTOR Fc
Fog0,25
Steam0,50
Powders0,50
Dense smoke0,25
If the device is placed in environments subject to sudden temperature uctuations, it is imperative
to take the appropriate steps to avoid condensation on the lenses, which may impair the detection
capability.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
8
Safety
LIST OF APPLICABLE STANDARDS
SAFEGATE is manufactured in compliance with the following European Directives:
SILCL 3¾ IEC 62061:2005/A2:2015
PL e - Cat. 4¾ EN ISO 13849-1: 2015
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
9
Safety
EC DECLARATION OF CONFORMITY
Dichiarazione CE di conformità
EC declaration of conformity
REER SpA
via Carcano 32
10153 – Torino
Italy
dichiara che le barriere fotoelettriche SAFEGATE sono Dispositivi Elettrosensibili di Sicurezza (ESPE) di :
Tipo 4 (secondo la Norma EN 61496-1:2013; EN 61496-2:2013)
SIL 3 (secondo la Norma EN 61508-1:2010; EN 61508-2:2010; EN 61508-3:2010; EN 61508-4:2010)
SILCL 3 (secondo la Norma EN 62061:2005/A2:2015)
Cat.4 - PL e (secondo la Norma EN ISO 13849-1:2015)
declares that the SAFEGATE photoelectric safety barr
Type 4 (according the Standard EN 61496-1:2013; EN 61496-2:2013)
SIL 3 (according the Standard EN 61508-1:2010; EN 61508-2:2010; EN 61508-3:2010; EN 61508-4:2010)
SILCL 3 (according the Standard EN 62061:2005/A2:2015)
Cat.4 - PL e (according the Standard EN ISO 13849-1:2015)
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
10
System architecture
SYSTEM ARCHITECTURE
SAFEGATE is supplied as a pair (Emitter/Receiver) and allows integration with external Muting sensors
that are directly connected to the connectors installed on the curtain.
¾ Each curtain can be congured as LX, L2, TX and T4 (see the dierent Muting types in the section
“MUTING FUNCTION”) through the wiring of the main connector. This conguration can be changed
at any time.
¾ SAFEGATE can be used with (pre-aligned and pre-congured) Muting arms, with M5 multibeam
photocells (available as accessories) or any other Muting sensor.
¾
S models integrate the functions of “START/RESTART INTERLOCK” and ”EDM” but do not allow the
Muting function.
¾
SM models allow the Muting function, but have no integrated signal lamp.
¾ Programmable
problems in complex application scenarios.
¾
SMO-SMPO models with Integrated signalling lamp allow the immediate viewing of the curtain status
even at a distance.
SMP-SMPO models allow an ideal use of further conguration options to solve potential
PLEASE NOTE
The sample gure represents the Receiver
of a SMPO model.
This model comes with integrated signal
lamp.
Additionally, the conguration connector
allows the USB connection to a PC with
the conguration software installed.
Main
connector
Integrated
Signalling
Lamp
Configuration
connector
and auxiliary
signal lamp
Seat for
anchorage
of any
Muting
arms
Sensor 3-4
Muting
connector
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
Sensor 1-2
Muting
connector
Signals
label
11
System architecture
POSSIBLE CONFIGURATIONS (via optional accessories)
MAL2X - braccetti L a 2 raggi incrociati TX/RX
MAL2X - L-arms with 2 crossed TX/RX beams
MAL2XE
EMITTER
Optional
Accessorio
Accessory
opzionale
MAT2X - T-arms with 2 crossed TX/RX beams
MAT2X - braccetti T a 2 raggi incrociati TX/RX
MAT2XE SX
EMITTER
Optional
Accessorio
opzionale
Accessory
SAFEGATE - EMITTER
SAFEGATE - RECEIVER
SAFEGATE - EMITTER
MAT2XE DX
EMITTER
Optional
Accessorio
Accessory
opzionale
MAL2XR
RECEIVER
Optional
Accessorio
Accessory
opzionale
SAFEGATE - RECEIVER
MAT2XR SX
RECEIVER
Optional
Accessorio
opzionale
Accessory
MAT2XR DX
RECEIVER
Accessorio
Accessory
opzionale
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
Optional
12
System architecture
MAL2P TRX - L-arms with 2 parallel beams with reector
MAL2PTRX - braccetti L a 2 raggi paralleli con riflettore
MA2P SX 2R
REFLECTOR
Optional
Accessorio
Accessory
opzionale
MAT4P TRX - T arms with 4 parallel beams with reectors
MAT4P TRX - braccet. T a 4 raggi paralleli con riflettore
MA2P SX 2B
EMITTER / RECEIVEREMITTER / RECEIVER
Optional
Accessorio
Accessory
opzionale
SAFEGATE - EMITTER
SAFEGATE - RECEIVER
SAFEGATE - RECEIVER
MA2P DX 2B
EMITTER / RECEIVER
Optional
Accessorio
Accessory
opzionale
MA2P DX 2B
Optional
Accessorio
Accessory
opzionale
MA2P SX 2R
Optional
Accessorio
Accessory
opzionale
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
SAFEGATE - EMITTER
MA2P DX 2R
REFLECTORREFLECTOR
Optional
Accessorio
Accessory
opzionale
13
System architecture
MZL2XP arms with 2 cross-linked/parallel adjustable M5 beams
MZL2XP - braccetti L a 2 raggi incrociati/paralleli regolabili M5
MZL2XPE MZL2XPR
EMITTERRECEIVER
Optional
Accessorio
Accessory
opzionale
MZT2X - T-arms with 2 adjustable M5 cross beams
MZT2X - braccetti T a 2 raggi incrociati regolabili M5
SAFEGATE - EMITTER
SAFEGATE - RECEIVER
Optional
Accessorio
Accessory
opzionale
MZT2XE SX
EMITTERRECEIVEREMITTERRECEIVER
Optional
Accessorio
Accessory
opzionale
SAFEGATE - EMITTER
MZT4P - T-arms with 4 adjustable M5 parallel beams
MZT4P - braccetti T a 4 raggi paralleli regolabili M5
MZT2XE DX
Optional
Accessorio
Accessory
opzionale
MZT4PE SXMZT4PE DX
EMITTER
Optional
Accessorio
Accessory
opzionale
SAFEGATE - EMITTER
MZT2XR SX
Optional
Accessorio
Accessory
opzionale
EMITTER
Optional
Accessorio
Accessory
opzionale
SAFEGATE - RECEIVER
MZT2XR DX
Optional
Accessorio
Accessory
opzionale
MZT4PR SXMZT4PR DX
RECEIVER
Optional
Accessorio
Accessory
opzionale
SAFEGATE - RECEIVER
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
RECEIVER
Optional
Accessorio
Accessory
opzionale
14
The Muting function
THE MUTING FUNCTION
The Muting function is the temporary exclusion of the safety curtain, automatically and safely carried out
based on the machine cycle.
ÎÎ Carefully verify your risk analysis to make sure the Muting function is compatible with your
application and what additional measures should be taken.
There are basically two types of applications:
1. Those allowing people to enter the dangerous area during the non-dangerous part of the machine
cycle.
Example:
Positioning or Removing the workpiece
Depending on the position of the tool, which is the hazardous
element, one of the two curtains (the one facing the tool
work area) is active while the other is in Muting condition
to allow the operator loading/unloading the workpiece. The
Muting condition of the two curtains will then be reversed
when the tool is to work on the opposite side of the machine.
2. Those who allow material transit and prevent access to the people.
Example: Pallet exit from the hazardous area
The safety curtain is equipped with Muting sensors able to
eectively discriminate between the person and the material
allowed to get through the controlled gate. The essential
requirements concerning the Muting function are described
in the following Standards:
ÎÎ IEC TS 62046 - “Application of protection devices for people
detection”.
ÎÎ EN 415-4 - “Safety on packaging machines – Palletizers and
¾ The Muting function is a temporary suspension of the safety function that needs to be activated and
deactivated automatically.
¾ The activation and subsequent deactivation of the Muting function must take place only through the use
of two or more wired and independent signals activated by a correct timing or spatial sequence. This
means that a stand-alone failure cannot activate the Muting function.
¾ It should not be possible to activate the Muting function when SAFEGATE has deactivated the safety
outputs.
¾ It should not be possible to start a Muting function by switching o and then restarting the device.¾ Muting must be activated at an appropriate point of the machine cycle, i.e. only when there are no risks
for the operator.
¾ Muting sensors must be mechanically protected so that any impact does not modify their alignment.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
15
The Muting function
A) 2 INTEGRATED CROSS MUTING SENSORS, ONLY FOR PALLET OUTPUTS (LX)
In this way sensors 1 and 2 are on the same side as the vertical curtain and are placed in front of the
dangerous gate. This mode is unidirectional and is useful for protecting gates with pallet output.
The activation of the Muting function occurs after the simultaneous interruption (within 4 sec maximum) of
S1 and S2 sensors. As long as both sensors remain busy, the Muting function continues. When the rst of
the 2 sensors is released, the material will still have 4 seconds to leave the protected area limited by the
curtain. The Muting condition will be disabled as soon as the protected area is released.
At the end of 4 seconds, if the curtain is still busy, the OSSD outputs are disabled by interrupting the
operation of the machine. This allows selecting the maximum duration of the Muting condition (timeout) as
30 seconds or 9 hours.
ÎÎ Other timings are available with programmable programs.
Î For the safe operation of the LX conguration, it is absolutely essential that the horizontal Muting
sensor elements are located within the hazardous area.
Î The minimum distance between two consecutive pallets must be less than 10 cm or greater than
32cm.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
16
The Muting function
B) 2 INTEGRATED PARALLEL MUTING SENSORS, ONLY FOR PALLET OUTPUTS (L2)
In this way sensors 1 and 2 are on the same side as the vertical curtain and are placed in front of the
dangerous gate. This mode is unidirectional and is useful for protecting gates with pallet output.
The activation of the Muting function occurs after the simultaneous interruption (within max 4 sec) of
sensors S1 and S2. As long as both sensors remain busy, the Muting function continues. When the rst
of the 2 sensors is released, the material will still have 4 seconds to leave the protected area limited by
the curtain. The Muting condition will be disabled as soon as the protected area is released. At the end of
4 seconds, if the curtain is still busy, the OSSD outputs are disabled by interrupting the operation of the
machine.
This allows selecting the maximum duration of the Muting condition (timeout) as 30 seconds or 9 hours.
ÎÎ Other timings are available with programmable programs.
Î For the safe operation of the L2 conguration, it is imperative that horizontal Muting sensors are
located within the hazardous area.
Î The minimum distance between two consecutive pallets must be greater than 40 cm.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
17
The Muting function
C) 2 INTEGRATED CROSS MUTING SENSORS, FOR BI-DIRECTIONAL GATES (TX)
In this way, the two Muting sensors are each rst on a dierent side of the vertical curtain.
This mode is unidirectional and is useful for protecting gates with pallet output.
ÎÎ The crossing point of the two Muting sensors must be placed inside the hazardous area to avoid
undesirable and dangerous activations of the Muting function.
The activation of the Muting function occurs after the simultaneous interruption (within max 4 sec) of
sensors S1 and S2. As long as both sensors remain busy, the Muting function continues. By releasing the
rst of the two sensors, the Muting function is disabled.
This mode also allows selecting the maximum duration of the Muting condition (timeout) as 30 seconds or
9 hours.
ÎÎ Other timings are available with programmable programs.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
18
The Muting function
D) 4 INTEGRATED PARALLEL MUTING SENSORS, FOR BI-DIRECTIONAL GATES (T4)
This mode is bidirectional and is useful for protecting gates with pallet output.
Using this mode, two dierent modes of operation are outlined:
Concurrent
The activation of the Muting function occurs after the sensors S1 and S2 are interrupted (within max 4sec)
(or S4 and S3 with material moving in the opposite direction).
The Muting state ends after the release of the gate, and of the S3 sensor (or S2 with material moving in
the opposite direction).
ÎÎ For the T4 models (concurrent operation), there are two available timeouts: 1) 30 sec; 2) 9 hours.
Sequential
The activation of the Muting function occurs after the sequential interruption of sensors S1 and S2 (or S4
and S3 with material moving in the opposite direction) without time limitations.
The Muting state ends after the release of the gate, and of the S3 sensor (or S2 with material moving in
the opposite direction).
ÎÎ For the T4 models (sequential operation), there are two available timeouts: 1) 30 sec; 2) innite.
ÎÎ Other timings are available with programmable programs.
ÎÎ In both modes of operation, the minimum pallet length must be 70 cm (to ensure simultaneous
occupancy of all four sensors).
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
This mode is bidirectional and is useful for protecting gates with pallet output.
ÎÎ The crossing point of the two Muting sensors must be placed inside the hazardous area to avoid
undesirable and dangerous activations of the Muting function.
The activation of the Muting function occurs after the simultaneous interruption (within max 4 sec) of
sensors S1 and S2. As long as both sensors remain busy, the Muting function continues. When the rst
of the two sensors is released, the Muting function is disabled. In this mode of operation the maximum
duration of the Muting condition (timeout) can be selected in 30 seconds or 9 hours.
ÎÎ Other timings are available with programmable programs.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
20
The Muting function
F) 4 EXTERNAL PARALLEL MUTING SENSORS, FOR BI-DIRECTIONAL GATES (T4).
This mode is bidirectional and is useful for protecting gates with pallet output.
Using this mode, two dierent modes of operation are outlined:
Concurrent
The activation of the Muting function occurs after the sensors S1 and S2 are interrupted (within max 4
sec) (or S4 and S3 with material moving in the opposite direction).
The Muting state ends after the release of the gate, and of the S3 sensor (or S2 with material moving in
the opposite direction).
ÎÎ For the T4 models (concurrent operation), there are two available timeouts: 1) 30 sec; 2) 9 hours.
Sequential
The activation of the Muting function occurs after the sequential interruption of sensors S1 and S2 (or S4
and S3 with material moving in the opposite direction).
The Muting state ends after the release of the gate, and of the S3 sensor (or S2 with material moving in
the opposite direction).
ÎÎ For the T4 models (sequential operation), there are two available timeouts: 1) 30 sec; 2) innite.
ÎÎ Other timings are available with programmable programs.
ÎÎ In both modes of operation, the minimum pallet length must be 70 cm (to ensure simultaneous
occupancy of all four sensors).
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
21
The Muting function
PARTIAL MUTING
The Partial Muting feature allows you to limit the
Muting function to a number of well-dened beams.
By this function, you can enable the Muting function
only for those beams that will be interrupted by the
passage of the material (e.g. lower pallets at the end
of the product cycle). The remaining beams, however,
can be kept active to protect the dangerous gate.
ÎÎ This function is only available on SMP/SMPO
models and must be managed through the
Safegate Congurator software (select “Partial
Muting Enabling”).
The software should then select the number of beams aected by Partial Muting, taking into account that
the rst Partial Muting beam always starts from the bottom (connectors side).
For this operation, it may be useful to verify the
Monitor software function (free beams are indicated
by dierent colouring than the busy ones) and the
various numerical information on the side (LBO,
FBO, etc.).
Only one value can be entered when programming
the number of beams aected by this function.
There are two types of partial Muting and, for both,
the “Partial Muting” input pin (pin 6 of M12 12-pin
connector on the receiver) must be used.
Partial Muting with Enable
With this option, the Partial Muting function is normally deactivated. To activate this function, the input
signal (pin 6 of the receiver) must switch from LO to HI (rising edge) before starting the Muting cycle.
Partial Muting with Disable
With this option the Partial Muting function is normally active. To activate this function, the input signal (pin
6 of the receiver) must switch from LO to HI (rising edge) before starting the Muting cycle.
ÎÎ Refer to the “OPERATING MODES” section to correctly set this function.
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
22
The Muting function
MUTING OVERRIDE
The OVERRIDE function becomes necessary when, after incorrect Muting activation sequences, the
machine stops leaving the material in the dangerous gate.
In this situation, the OSSD outputs are inactive because the curtain and/or at least one Muting sensor are
busy. In this condition, the OVERRIDE request LED ashes.
Î This operation activates the OSSD outputs to remove the material obstructing the gate.
Î During the entire phase in which the OVERRIDE function is active, the Override/Muting lamp ashes.
You should periodically verify the eciency of this lamp (during Muting or Override phases).
Î The Pulse Override command automatically activates the curtain outputs until both the curtain and
the Muting sensors are again free of obstacles. During this period the curtain is not able to protect
access to the dangerous gate. It is therefore necessary that all operations be conducted under close
supervision of experienced personnel.
The user will use the type of Override previously congured:
1. Override with spring return key
2. Override with pushbutton
Override with spring return key
Activation of this function must be done by bringing both receiver pins 9 and 10 to + 24VDC (within a 400
ms time window), for example by using a 2-way key switch with spring return.
Override has a maximum duration of 15 minutes; it can end due to two dierent causes.
1. When the selector is released or the 15 minutes expire, the override ends, bringing the outputs to
OFF, turning o the lamp, and returning the display to normal. However, it is still possible to start a
new override, releasing the selector and reactivating it.
2. At the release of the curtain and sensors (clear gate) the override ends and the GUARD condition is
reactivated (the curtain is working properly) without additional commands.
Override with pushbutton
The activation of this function must occur inverting (within a time window of 400 ms) the condition of pins
9 and 10 of the receiver through the use of a 2-way switch.
When override is active the condition of pins 9 and 10 is no longer veried.
MAXIMUM OVERRIDE TIME (MODELS WITH HARDWARE CONFIGURATION)
The override has a maximum duration of 15 minutes (repeatable).
The function can only restart if the button is pushed again (complying with the following conditions):
1. Maximum OVERRIDE time (after n consecutive requests) = 60 min
2. Maximum number of consecutive OVERRIDE requests = 30.
MAXIMUM OVERRIDE TIME (MODELS WITH SOFTWARE CONFIGURATION)
The function can only restart if the button is pushed again (complying with the following conditions):
1. Maximum OVERRIDE time (after n consecutive requests) = 4 x timeout override
2. Maximum number of consecutive OVERRIDE requests = 30.
At the release of the curtain and sensors (clear gate) the override ends and the GUARD condition is
reactivated (the curtain is working properly) without additional commands.
The timer (point 1) and the counter (point 2) are reset if one of the following conditions occurs:
¾A proper sequence of Muting.¾A system reset (turning it o and on).
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
23
Mechanical installation
INSTALLATION
CALCULATION OF THE SAFETY DISTANCE
The eectiveness of the protection heavily depends
on the correct positioning of the curtain according
to the danger. The curtain must be positioned at a
distance greater than or equal to the minimum safety
distance S so that reaching the dangerous point can
only be achieved after the dangerous operation of the
machine has stopped.
The positioning shall be such that:
• Reaching the dangerous point is avoided without
crossing the area controlled by the curtain.
• No person is allowed in the dangerous area
without this being detected. For this case,
additional safety devices (e.g. horizontal light
curtains) may be required.
S
CKxT
1
2
a
The ISO 13855 standard provides the elements for
3
calculating the safety distance.
1. Dangerous point
If the machine under consideration is subject to a type
C specic standard, reference should be made to this
rule.
2. Protected plane
3. Reference plane
a. Height of dangerous point
S. Safety distance
If the S distance calculated appears to be excessive,
it is necessary:
• to reduce the total time the machine is o
• to improve the resolution of the curtain.
GENERAL FORMULA FOR CALCULATING THE SAFETY DISTANCE
S = K x T + C
S
K
minimum safety distance between the protection and the dangerous point, expressed in mm.
advance speed of the body or parts of the body, expressed in mm per second.
K values can be:
K = 2000 mm per second for safety distances up to 500 mm
K = 1600 mm per second for safety distances over 500 mm
Total machine stopping time including:
T
C
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
T1 response time of the protection device in seconds
T2 machine reaction time to stop the hazardous operation, in seconds.
additional distance expressed in mm.
24
Mechanical installation
MODELS WITH RESOLUTION 30 mm – 40 mm
Curtains with resolution
for arms detection.
Curtain resolution (d) 30 - 40 mm
S
Protected
plane
H
MODELS WITH 2/3/4 beams
Body detection curtains.
Curtain with 2/3/4 beams
Dangerous
point
Calculating the minimum
safety distance (S)
Refer to the general formula
for the safety distance
calculation.
S = K x T + C
S = 2000xT + 8x(d-14)
If the formula provides as a
result: S>500 it’s possible to
use
K=1600
S = 1600xT + 8x(d-14)
(withC = 8x(d-14))
• The S distance must
not be less than
100mm
• If the resulting
distance S is greater
than 500 mm, you
can recalculate the
distance using K =
1600.
• In this case the
distance must still not
be less than 500 mm.
S
Recommended height
according to the number
of beams
N°Recommended height
2 400 - 900 mm
3 300 - 700 - 1100 mm
4 300 - 600 - 900 - 1200 mm
Protected
plane
H≥1100
H≥700
H≤300
Dangerous
point
Refer to the general formula
for the safety distance
calculation.
S = K x T + C
S = 1600xT + 850
ÎÎ The S distance must not be less than 100 mm
ÎÎ If the resulting distance S is greater than 500 mm, it is possible to recalculate the distance using
K = 1600 but in this case the distance must still not be less than 500 mm
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
25
Mechanical installation
ÎÎ For applications on packaging machines (palletizers and unpalletizers), follow the instructions in
European standard EN 415-4, which are repeated here.
From low level (oor)
Device with 3 beams at least
Dimensions in m
Above the conveyor (rollers)
Device with 2 beams at least
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
26
Mechanical installation
MULTIPLE SYSTEMS
ÎÎ When using multiple SAFEGATE systems, it is necessary to avoid them interfering optically with one
another: position the elements so that the beam emitted by the system Emitter is received only by
the respective Receiver.
The following gure shows some examples of correct positioning between the two photoelectric systems.
An incorrect positioning may cause interference, leading to an abnormal operation.
Systems side by side: A
Adjacent positioning of the two projectors
Overlapping systems: B
“L” combination: C
Cross-positioning between
projectors and receivers
8541150 - rev.1 - 10/07/2017
REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it
27