With the publication of Edition 3 of the harmonized EN 61496-1 standard it is no longer possible to use a Type 2 safety light barrier for safety functions assessed as SIL 2 / PL d.
If a safety level of SIL 2 / PL d (or higher) is required and it is nevertheless intended to use a safety light barrier, then it will be necessary to use a Type 4 safety light barrier.
This regulatory requirement derives from the fact that the reduction of risk that can be obtained via a photoelectric safety barrier is not only a function of the safety level of its electronic parts, but is also determined by its systematic capabilities (for example: environmental influences, EMC, optical performance and detection principle).
The systematic capability of a Type 2 photoelectric barrier may in fact not be sufficient to ensure adequate risk reduction for SIL 2 / PL d applications.
The standard also establishes that the labelling of Type 2 safety barriers must indicate such limitation to SIL 1 / PL c.
The PFHd values declared for the electronic control part of the device, on the other hand, are not limited and therefore it is possible to use the PFHd value provided by the manufacturer of the device in the global assessment of the safety function, even if it exceeds the SIL 1 / PLc range.
0 Vdc
+24 Vdc
Automatic
+24 Vdc
+24 Vdc through a N.O. contact
Manual
0 Vdc
0 Vdc
Non-permissible
conditions
+24 Vdc
+24 Vdc
1
24VDC
Power supply 24Vdc
2
0VDC Power supply 0Vdc
3
PE Ground connection
4
RESTART
Input
Restart command
5
MAN/AUTO
Input
Manual/Automatic Configuration
6
SYSTEM_TEST
Input
Test of the system external request
7
INPUT BARR1
Input
Safety photocell number 1
status input
8
INPUT BARR2
Input
Safety photocell number 2
status input
9
TEST_BARR1
Output
Safety photocell number 1 TEST
10
TEST_BARR2
Output
Safety photocell number 2 TEST
11
K1K2 (Feedback)
Input
Feedback external contactors K1K2
12
SYSTEM STATUS
Output
Output status
13
Relay B NO1
Output
Safety relay B, contact 1 (N.O.)
14
Relay B NO2
Output
Safety relay B, contact 2 (N.O.)
15
Relay A NO1
Output
Safety relay A, contact 1 (N.O.)
16
Relay A NO2
Output
Safety relay A, contact 2 (N.O.)
Minimum switching voltage
18 Vdc
Minimum switching current
20 mA
Maximum switching voltage
250Vac
Maximum switching current
2A
Control contacts
K1-1 normally closed
K2-1 normally closed
Use contacts
K1-2 normally open
K2-2 normally open
Green
Photocell 1 free
Photocell 1 intercepted
Green/
Red
Fault detected *
Photocell 2 free
Photocell 2 intercepted or absent
Green/
Red/
YELLOW
Output relays opened
The number of blinkings shows the
kind of FAIL (only with IN2/FAIL RED) *
Output relays closed
Photocells free - Output relays opened
(only in manual mode)
Table 3
* REFER TO THE "FAULT DIAGNOSIS" SECTION TO HAVE A DETAILED EXPLANATION OF THE POSSIBLE FAULT
5 6 7 8
1 2 4
13 14 15 16
9 10 11 12
IN1
IN2
FAIL
GUARD
BREAK
AUS X
Safety category
2
Power supply
Vdc
24 20%
Power requirement W 5 max
Output
Relay
2 N.O. contacts (2A; 250V)
System Status Output
100mA; 24Vdc
Response time
ms
30 max
Operating modes
Manual or Automatic, selectable
from terminal block
External relay control
2 N.C. contacts (20mA; 24Vdc)
Number of connectable photocells
1 ÷ 4
Connections
Terminal block with protection
against reversal of polarity
Status indicators
Led
Power On – Photocell Status – Fail
Max. length of connections
m
100
Operating temperature
°C
0 ÷ 55
Enclosure protection rating
IP 20
Terminal block protection rating
IP 2X
Fastening
Fast attachment to rail according
to EN 50022-35
Dimensions (h x w x d)
mm
99 x 22,5 x 114,5
Weight
g
150
B10d
800.000
Device lifetime
20 years
Safety level
Type 2
EN 61496-1:2013
SILCL 1
IEC 62061(ed.1)
Cat.2
EN ISO 13849-1:2008
Load
Number of Commutations
PFHd *
DCavg #
MTTFd #
PL #
CCF #
2A@230Vac
1 every 30s
2,64E-08
98,92%
26,04
c
80%
1 every min
1,55E-08
98,85%
50,18
c
80%
1 every hour
4,98E-09
97,28%
100,00
c
80%
1 every day
4,82E-09
96,95%
100,00
c
80%
0,5A@24Vdc
1 every 30s
4,87E-08
98,96%
13,27
c
80%
1 every min
2,64E-08
98,92%
26,04
c
80%
1 every hour
5,16E-09
97,54%
100,00
c
80%
1 every day
4,83E-09
96,97%
100,00
c
80%
ON
RED
RED
Power on TEST
OFF
OFF
RED
Photocell INTERCEPTED,
outputs in OFF
ON
OFF
YELLOW
Photocell FREE,
outputs in OFF
ON
OFF
GREEN
Photocell FREE,
outputs in ON
Shows the
photocell_1 status
OFF
YELLOW: blinks 2
times per second
System TEST
ON
RED
RED
Power on TEST
OFF
OFF
RED
Photocell INTERCEPTED,
outputs in OFF
OFF
ON
RED
ON
OFF
RED
ON
ON
YELLOW
Photocell FREE,
outputs in OFF
ON
ON
GREEN
Photocell FREE,
outputs in ON
Shows the
photocell_1 status
Shows the
photocell_2 status
YELLOW: blinking 2
times per second
System TEST
OFF
ON
(2 pulses)
Possible fault to the
Microcontroller board
OFF
ON
(3 pulses)
Internal relays fault
OFF
ON
(4 pulses)
K1K2 external relays
fault
OFF
ON
(5 pulses)
User configuration
failure
OFF
ON
(6 pulses)
User configuration
changed without
system restart
OFF
ON
(7 pulses)
Possible overload or
SYSTEM STATUS
connection error
0 Vdc
+24 Vdc
Automatic
+24 Vdc
+24 Vdc through a N.O. contact
Manual
0 Vdc
0 Vdc
Non-permissible
conditions
+24 Vdc
+24 Vdc
SENSOR 1
SENSOR 2
MUTING
FIELD FREE
FIELD INTERRUPTED
TIMER 4 SEC
30s
SENSOR 1
SENSOR 2
MUTING
FIELD FREE
FIELD INTERRUPTED
TIMER 4 SEC
0 0 Normal operation
24VDC
24VDC
OVERRIDE request
0
24VDC
Normal operation
24VDC
0
OVERRIDE request
1
Input
Muting Sensor n°1
2
Input
Muting Sensor n°2
3
Input
Power supply 24Vdc
4
Input
Timeout selection n°1 *
5
Input
Timeout selection n°2 *
6
Input
Manual/Automatic configuration
7
Input
Override selection n°1 **
8
Input
Override selection n°2 **
9
Output
Safety photocell number 1 TEST
10
Output
Muting lamp output
11
Input
External muting enable input
12
Output
Safety relay B, contact 1 (N.O.)
13
Input
Power supply 0Vdc
14 - Ground connection
15
Input
Restart command Input
16
Input
Test of the system external request
17
Input
Safety photocell number 1 status
18
Input
Safety photocell number 2 status
19
Output
Safety photocell number 2 TEST
20
Input
K1K2 external contactors feedback
21
Output
Output safety relays status
22
Output
Safety relay B, contact 2 (N.O.)
23
Output
Safety relay A, contact 1 (N.O.)
24
Output
Safety relay A, contact 2 (N.O.)
0 Vdc
+24 Vdc
30s
+24 Vdc
0 Vdc
Infinite
0 Vdc
0 Vdc
Conditions
not allowed
+24 Vdc
+24 Vdc
0 Vdc
0 Vdc
Spring return key
0 Vdc
+24 Vdc
Push button
+24 Vdc
0 Vdc
Conditions
not allowed
+24 Vdc
+24 Vdc
Minimum switching voltage
18 Vdc
Minimum switching current
20 mA
Maximum switching voltage
250Vac
Maximum switching current
2A
Control contacts
K1-1 normally closed
K2-1 normally closed
Use contacts
K1-2 normally open
K2-2 normally open
YELLOW
Muting sensor 1 free
Muting sensor 1 interrupted
YELLOW
Muting sensor 2 free
Muting sensor 2 interrupted
YELLOW
Correct operation
Muting active
Override request Muting fail (only with FAIL led ON) *
Green
Photocell 1 interrupted
Photocell 1 free
Green
Red
Photocell 2 interrupted
Photocell 2 free
Failure detected *
Green
Red
YELLOW
Output relays closed
Output relays opened
The number of blinkings shows the
kind of FAIL (only with IN2/FAIL RED) *
Photocells free - Output relays opened
(only in manual operative mode)
Table 12
4 5 6 16 17 18
1 2 3 13 15
10 11 12 22 23 24
7 8 9 19 20 21
S1
S2
MUT.
AUS XM
IN1
IN2
FAIL
GUARD
BREAK
Safety category
2
Power supply
Vdc
24 20%
Power requirement W 5 max
Output
Relay
2 N.O. contacts (2A; 250V)
System Status Output
100mA; 24Vdc
Muting lamp output
24Vdc / 0,5 5 W
Response time
ms
30 max
Operating modes
Manual or Automatic, selectable
from terminal block
External relay control
2 N.C. contacts (20mA; 24Vdc)
Number of connectable photocells
1 ÷ 4
Muting sensors input
2 sens. (24VDC; PNP; dark-on)
Muting enable input 24VDC, PNP
Connections
Terminal block with protection
against reversal of polarity
Status indicators
Led
Power On – Photocell Status –
Fail - Muting active - Override active
Max. length of connections
m
100
Operating temperature
°C
0 ÷ 55
Enclosure protection rating
IP 20
Terminal block protection rating
IP 2X
Fastening
Fast attachment to rail according
to EN 50022-35
Dimensions (h x w x d)
mm
99 x 35 x 114,5
Weight
g
215
B10d
800.000
Device lifetime
20 years
Safety level
Type 2
EN 61496-1:2013
SILCL 1
IEC 62061(ed.1)
Cat.2
EN ISO 13849-1:2008
Load
Number of Commutations
PFHd *
MTTFd #
DCavg #
PL #
CCF #
2A@230Vac
1 every 30s
2,81E-08
25,94
98,89%
c
80%
1 every min
1,72E-08
49,82
98,78%
c
80%
1 every hour
6,63E-09
100,00
96,73%
c
80%
1 every day
6,47E-09
100,00
96,32%
c
80%
0,5A@24Vdc
1 every 30s
5,03E-08
13,24
98,94%
c
80%
1 every min
2,81E-08
25,94
98,89%
c
80%
1 every hour
6,81E-09
100,00
97,05%
c
80%
1 every day
6,48E-09
100,00
96,36%
c
80%
ON
RED
RED
Power up test
OFF
OFF
RED
Photocell interrupted
Output relays opened
ON
OFF
YELLOW
Photocell free
Output relays opened
ON
OFF
GREEN
Photocell free
Output relays closed
System test
OFF
YELLOW: blinking 2
times per second
System test
ON
RED
RED
Power up test
OFF
OFF
RED
Photocell interrupted
Output relays opened
OFF
GREEN
RED
ON
OFF
RED
ON
GREEN
YELLOW
Photocell free
Output relays opened
ON
GREEN
GREEN
Photocell free
Output relays closed
Shows the
photocell_1 status
Shows the
photocell_2 status
YELLOW: blinking 2
times per second
System test
ON
ON
ON
Power up test
OFF
OFF
OFF
Both the sensors are free
ON
OFF
OFF
Sensor 1 interrupted
OFF
ON
OFF
Sensor 2 interrupted
ON
ON
ON
Muting active
Shows the
sensor_1 status
Shows the
sensor_2 status
Blinking
Override request
OFF
ON
(2 pulses)
Possible fault to the
Microcontroller board
OFF
ON
(3 pulses)
Internal relays fault
OFF
ON
(4 pulses)
K1K2 external relays
fault
OFF
ON
(5 pulses)
User configuration
failure
OFF
ON
(6 pulses)
User configuration
changed without
system restart
OFF
ON
(7 pulses)
Possible overload or
SYSTEM STATUS
connection error
OFF
OFF
(2 pulses)
Bad connection of the muting lamp, lamp not present or in overload
OFF
OFF
(3 pulses)
Muting timeout wrong configuration
OFF
OFF
(4 pulses)
Wrong override configuration at the power up
Shows the
sensor_1
status
Shows the
sensor_2
status
(5 pulses)
Instable muting Sensor
Blinking
Blinking
Blinking
Override with pulse command expired
Precise, complete compliance with all the rules, instructions and prohibitions indicated in this handbook is an essential requirement for correct functioning of the control unit. ReeR s.p.a. therefore declines any responsibility for all and anything resulting from failure to comply, even partially, with such indications.