Operating Instructions
Spring Driven Light Cord Reels
Model Number:
LD2040 163 2
IMPORTANT
Read this manual before attempting to operate
or service this unit.
Care and Operation of your New Fluorescent Worklight
CAUTION
1. Inspect cord regularly for damage and replace if necessary for user safety.
2. Do not submerge.
3. When hanging reel on ceiling (see bottom of second page):
• By hook: Close hook with pliers to prevent reel from falling down.
• By Bracket Pin: With reel in place, bend end of “L” shaped pin to prevent pin from falling out.
• Read mounting instructions carefully before installing.
4. Use in covered areas out of rain and weather.
5. Tool Tap Models:
• Do not exceed maximum Tool Tap amperage rating of 7 Amps.
• Pull cord all the way out of reel when using the tool tap.
CAUTION,IMPORTANTSAFETYINSTRUCTIONS - This portable lamp has a polarized plug (one blade is wider
than the other) as a feature to reduce the risk of electric shock. This plug will fit in a polarized outlet only one
way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use an extension cord unless plug can be fully inserted. Do not alter the plug.
Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725
Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605
Customer Service: 855-634-9109 • reelcraft@reelcraft.com • www.reelcraft.com
12/2012
Spring Driven Light Cord Reel
OPERATIONANDMAINTENANCEINSTRUCTIONS
1. Plug the unit into a 120V AC outlet. The power supply cord is UL listed and meets OSHA standards.
2. Disconnect the power supply before servicing.
3. Keep the unit free from grease and dirt by using a damp cloth with mild detergent, or waterless hand
cleaner. This removes dirt from scratches in the outer tube and will provide the best light output at all
times. If the tube is damaged or badly scratched, it is easily replaced and is available as a replacement
part (see opposite page for contact information).
4. Do not use solvents such as gasoline to clean unit or cord as it makes the parts brittle. Do not allow brake
fluid to contact the outer tube as it will cause permanent damage.
RELAMPING
1. Disconnect the power suppy (unplug).
2. Slide cord end cap down.
3. Remove screws and slide outer tube assembly off of light fixture.
4. Pull lamp out of socket and replace.
5. Reverse steps 1 - 3. Relamping finished.
Mounting Instructions
OptionalWallor
CeilingMount
180°Rotation
OptionalWallorCeilingMount
1. Select location within 2 feet of an electrical outlet.
2. Attach U shaped bracket “A” to solid part of the wall or ceiling using screws (provided).
3. Place hanger bracket “B” inside U shaped bracket “A” lining up small holes in bracket.
4. Insert locking pin “C” through lined-up holes. Be sure to bend the end of locking pin as shown.
OptionalCeilingMount
Installation
CeilingMount
360°Rotation
1. Select location within 2 feet of an electrical outlet.
2. Screw the hanger hook securely into the ceiling. Hook must screw into wood frame behind drywall.
3. Hang reel on hook.
4. Close hook with pliers to prevent reel from coming off. Refer to point “A”.
5. Adjust cord stop so light or outlet hangs at desired length when cord is retracted.
Page 2