• Memory capacity: Normal Mode: 1GB - 16 GB;
Peak Hold: 1000 data no. (max)
• Display units in Kg, lb, Newton
• Tension and compression capability
• Full capacity zero (tare) control capability
• Fast/Slow response time
• Positive or reverse display direction
• Over load protection
• Real time SD memory card datalogger with a built-in clock and
calendar
• No extra software needed, just plug the SD card into the computer
and it downloads directly to EXCEL
• SD card capacity: 1 GB to 16 GB
• Easy to read LCD with backlight
• Auto power off or manual power off
• High accuracy microcomputer circuit
• Power by UM3/AA (1.5 V) x 6 batteries
• USB/RS232 Computer interface
Specifications
Circuit: Custom microprocessor LSI circuit
Display: 52mm x 38mm LCD with backlight
Units: Kg, lb, Newton
Measuring Capacity: 100Kg / 220.5lb / 980.6N
www
reedinstruments
www.GlobalTestSupply.com
com
3
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Min. Display: 0.15Kg / 0.02lb / 0.2N
Accuracy: ±(0.5% + 2 digits), within 23±5°C
Sampling Time: 0.2 to 0.6 seconds
Auto Sampling Time: 1 second to 9 hours
Peak Hold: 10mS - 500mS
Full Scale Deection: Less than 1mm
Zero/Tare Control: Max full capacity
Memory Card: SD memory card, 1 GB to 16 GB
Data Output: USB/RS232 PC computer interface
Operating Temperature: 0 to 50°C (32 to 122°F)
Operating Humidity: Less than 85% R.H.
Power Supply: UM3/AA (1.5 V) x 6 batteries
Weight: 650g/1.43lb
Dimensions: 215 x 90 x 45mm (8.5 x 3.5 x 1.8”)
Includes: Separate load cell sensor with 2 hooks and
16GB Micro SD Memory Card w/Adapter
(RSD-16GB)
Test stand (FS-1001)
Wedge grip (WG-01)
USB cable (USB-01)
AC Adapter, 110V (RSD-ADP-NA)
AC Adapter, 220V (RSD-ADP-EU))
Data Acquisition Software (SW-U801-WIN)
For service on this or any other REED product or information on other
REED products, contact REED Instruments at info@reedinstruments.com
www
reedinstruments
www.GlobalTestSupply.com
com
4
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Instrument Description
1. Sensor
2. Display
3. Power &
Backlight Button
4. Up & Zero Button
5. Fast, Slow,
& ESC Button
6. Peak & Enter Button
7. Display Reverse
& Down Button
8. Time & Set Button
9. Logger & Sampling
Check Button
10. USB/RS232 Output
11. Reset Button
12. AC/DC 9V
Power Adapter
Input Socket
13. Mounting Holes
14. Battery Compartment/
Cover
15. Sensor Hook
16. Force Sensor
17. Sensor Plug
18. SD card slot
www
reedinstruments
www.GlobalTestSupply.com
com
5
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Operating Instructions
When measuring Compression, the meter will show a “-” symbol. While
measuring, be sure to have the Sensor aligned with the object being measured. Do not measure on an angle, as the Sensor may be damaged and
the readings will not be accurate.
1. Turn on the meter by pressing the Power Button. To turn the meter
off, hold the Power Button for 2 seconds.
2. Select the measuring unit. For instructions on this, please see the
Advanced Settings section.
3. Connect an Adapter and the measuring object to the Sensor. The
measuring object should be in a straight line. Do not apply any
force while in Standby Mode.
4. Zero Adjust the meter by pushing Zero Button before every measurement.
5. Start measuring by giving force (push or pull) to the Sensor. The
screen will display the Average reading value. To change the display direction, push the Reverse Button.
6. There are two kind sampling time of display, Fast and Slow. The
Display will indicate “FAST” if measuring in Fast Sampling Time,
and “SLOW” if measuring under Slow Sampling Time. Push the
Fast/Slow Button to switch between Fast and Slow Sampling.
Note: Over range of tension will display as “
compression will display as “
----
Peak Hold Measurement
The meter can measure the peak value of force both of tension & compression operation. While taking a measurement, as described above,
press the Peak Button to switch to Peak Hold Mode. The Display will
show the “PEAK” indicator, and during measurement the Display will
freeze on the Peak hold value.
Alarm beeper
If the measuring value is over 100.00 Kg, an internal buzzer will sound.
www
reedinstruments
www.GlobalTestSupply.com
----
” and over range of
”.
com
6
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Backlight ON/OFF
After powering the meter ON, the LCD Backlight will turn on automatically. While taking measurements, press the Backlight Button and the LCD
Backlight will turn off. Press the Backlight Button once again to turn the
LCD Backlight back ON.
Datalogger
Preparation Before Executing the Datalogger Function:
1. Insert the optional SD card into the SD card socket.
2. Before you use an SD card with this meter for the rst time, it is
recommend to format the SD card. See Advanced Settings section of this manual for instructions.
3. If this is the rst time the meter is used you need to adjust the
clock. See Advanced Settings section of this manual for instructions.
4. Now you need to set the decimal format. The numerical data
structure downloaded to the SD card is defaulted used the “.”
as the decimal, for example “20.6” “1000.53”. But in certain
countries the “,” is used as the decimal point, for example “20,
6” “1000,53”. See Advanced Settings section of this manual for
instructions on how to change the Decimal Character.
Auto Datalogger (Set sampling time ≥1 second)
1. Start Datalogging; press the REC Button, and the “REC” symbol
will appear on the LCD screen, then press the Logger Button, the
“REC” symbol will ash while the measuring data and time information is being saved in memory. To set the sampling time, and to
toggle the beeper sound on or off, refer to the Advanced Settings
section of this manual.
2. Pause the Datalogging; while Datalogging, if press the Logger
Button once. While paused, the “REC” symbol will stop ashing.
Press the Logger Button again to resume Datalogging, and the
“REC” symbol will begin to ash again.
www
reedinstruments
www.GlobalTestSupply.com
continued...
com
7
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
3. Stop Datalogging; while the Datalogger function is paused, press
the REC Button for 2 seconds. The “REC” symbol will disappear
indicating the Datalogging function has stopped.
Manual Datalogger (Set sampling time = 0 seconds)
1. Set sampling time is to 0 second; Press the REC Button, and the
“REC” symbol will appear on the LCD screen. Press the Logger
Button, and the “REC” symbol will ash once and one Beep will
sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the
Position (record) number, which is saved as well.
2. To Change the Position Number; press the Down Button and the
lower position number will ash on the display. Press the Up or
Down Buttons to set the Position Number (1 to 99) to help identify
the measurement location. The lower Display will show P x (x = 1
to 99). After the position number is selected, press the Enter Button to conrm.
3. Stop Datalogging; press the REC Button for 2 seconds, and the
“REC” symbol will disappear indicating the Datalogging function
has stopped.
Peak Hold Datalogger
1. Install the meter on to the optional test stand and turn on the
meter
2. Press the Peak Button and the Display will show “PEAK” & “FAST”
3. Press the Zero Button to set the Zero Value
4. Press the Logger Button and the screen will display “DATA
RECORD” while the sampling time value in ms will appear on
the bottom of the screen. The meter is now ready for Peak Hold
Datalogging.
5. If the applied force value is > 0.2 Kg (1% full capacity), the
measurement value and sampling period will save to the internal
memory circuit in sequence. To change the Sampling Time, please
see the Advanced Settings section of this manual.
www
reedinstruments
www.GlobalTestSupply.com
continued...
com
8
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
6. When the peak value is obtained, the indicator “DATA RECORD”
will disappear, while the “PEAK” indicator and the Peak Value will
remain. The bottom of the Display will show the data record number and count down to zero, while saving the data to the SD card.
Checking the Time
During normal functions (not Datalogging), press the Time Check Button
and the lower LCD display will show the Year, Month/Date, Hour/Minute.
Check Sampling Time Information
During normal functions (not Datalogging), press the Sampling Button and
the lower LCD display will show the Sampling Time Information.
SD Card Data Structure
1. The rst time the SD card is used in the meter, the SD card will
generate a folder: FGC01
2. The rst time you use the Datalogger, in the folder FGC01, a new
le name FGC01001.XLS will be created. The Datalogger will use
this le until the Data has reached to 30,000 rows. The meter
will then will generate a new le with a subsequent number, for
example FGC01002.XLS.
3. The folder FGC01 can hold 99.XLS les. When that number has
been reached, the meter will then will generate a new folder with
a subsequent number, for example FGC02. Max number of FGC-folders is 10.
Data Transfer from SD card to Computer (EXCEL Software)
1. After Datalogging, remove the SD card from the SD card slot.
2. Plug in the SD card into the Computer’s SD card slot or insert the
SD card into the optional SD card adapter and connect to your
Computer. Turn your computer on and a folder will appear on your
desktop representing you SD card.
www
reedinstruments
www.GlobalTestSupply.com
continued...
com
9
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
3. Open “Microsoft EXCEL”. Download the EXCEL les from the SD
Card to the computer by opening up the SD folder and selecting the desired EXCEL les, and drag-and-drop them onto your
Computer. Open the les with EXCEL (File – Open).
4. The EXCEL le will have the following column headers in this
order: Place (Position Number), Date (Year/Month/Day), Time (in
24h clock), Value, and Unit.
Advanced Settings
During normal functions (not Datalogging), press and hold the SET Button
for 2 seconds to enter the “Advanced Setting” mode. Press the Next Button scroll through eight main functions, shown on the lower display:
Sd F SD memory card Format
dAtE Set clock time (Year/Month/Date, Hour/Minute/Second)
SP-t Set sampling time (Hour/Minute/Second)
HSPt Set sampling time for peak record mode
PoFF Auto power OFF management
bEEP Set beeper sound ON/OFF
unit Set the measurement unit
dEC Set SD card Decimal character
ESC Exit Advanced Settings
While in the “Advanced Setting” function, press the Esc Button to exit and
to return to normal functioning.
SD memory card Format
Please Note: Formatting the SD card erases all data from that SD card.
1. When the lower display shows “Sd F”, use the Up or Down Buttons to select “yES” (format the SD card) or “no” (do not format
the SD card).
2. To format your SD card, select “yES” and press the Enter Button.
The Display will show “yES Enter”, to conrm. Press the Enter
Button to conrm.
www
reedinstruments
www.GlobalTestSupply.com
com
10
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Set Clock Time
1. When the lower display shows “dAtE”, press the Enter Button.
Use the Up and Down Buttons to adjust the Year. After the desired
value is set, press the Enter Button to adjust the Month, Date,
Hour, Minute, and Second values.
2. After all the time values have been set the screen will jump to “SD
card Decimal character” setting screen. To exit “Advanced Settings”, press the Esc Button.
Note: After the time value is set, the internal clock will run even when
the power is off, if the battery is under normal conditions.
Set sampling time
1. When the lower display shows “SP-t”, use the Up or Down Buttons to adjust the value to either 0, 1, 2, 5, 10, 30,60, 120, 300,
600, 1800, or 3600 seconds.
2. After the Sampling value is selected, press the press the Enter
Button to save the setting as the default. To exit “Advanced Settings”, press the Esc Button.
Set sampling time (Peak Mode)
1. When the lower display shows “HSPt”, use the Up or Down
Buttons to adjust the Sampling Time value between 10mS and
500mS.
2. After the Sampling value is selected, press the press the Set Button to save the setting. To exit “Advanced Settings”, press the Esc
Button.
Auto power OFF management
1. When the lower display shows “PoFF”, use the Up or Down Buttons to select the value “yES” (Enable Auto Power Off) or “no”
(Disable Auto Power Off.
2. After selecting “yES” or “no”, press the Enter Button to save the
setting as the default. To exit “Advanced Settings”, press the Esc
Button.
www
reedinstruments
www.GlobalTestSupply.com
com
11
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Set Beeper Sound ON/OFF
1. When the lower display shows “bEEP”, use the Up or Down
Buttons to select “yES” (Beeper Sound is ON) or “no” (Beeper
Sound is OFF).
2. After selecting “yES” or “no”, press the Enter Button to save the
setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Setting the Decimal point on the SD Card
1. When the lower display shows “dEC”, use the Up or Down Buttons to toggle between “bASIC” (“.” Decimal Point) or “Euro” (“,”
Decimal Point).
2. After the Decimal point character has been selected, press the
Enter Button to save the setting as the default. To exit “Advanced
Settings”, press the Esc Button.
Set Measurement Unit
1. When the lower display shows “unit”, use the Up or Down Buttons
to adjust the measurement unit, Kg, lb, or N.
2. After the Measuring Unit is selected, press the press the Enter
Button to save the setting. To exit “Advanced Settings”, press the
Esc Button.
ESC
When the lower display shows “ESC”, press the Enter Button to nish
the Advanced Settings procedures and return to the normal measuring
screen.
www
reedinstruments
www.GlobalTestSupply.com
com
12
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
PC Serial Interface
The instrument features an PC output via 3.5 mm terminal. The connector
output is a 16 digit data stream which can be utilized to the user’s specic
application. An USB RS232 lead with the following connection will be
required to link the instrument with the PC serial input.
Meter (3.5mm Jack Plug) PC (9W “D” Connector)
Center PinPin 2
Ground/ShieldPin 5
The 16 digit data stream will be displayed in the following format:
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
D0End Word
D1 to D4Upper Display reading, D1= LSD, D4= MSB
D5 to D8D5=? D6=? D7=? D8=?
D9Decimal Point ( DP) for display
If an error occurs, press the Reset Button with a Pin. If the Reset Button
does not x the error, please send in the unit to our Calibration Lab for
repair. E-mail info@reedinstruments.com for more information.
Battery Replacement
1. When the left corner of LCD display shows , it is necessary to
replace the battery
2. Loosen the screws of the Battery Cover and remove
3. Remove the batteries and replace with Six DC 1.5 V batteries
(UM3, AA, Alkaline/heavy duty)
4. Make sure the battery cover is properly secured after changing the
battery
For service on this or any other REED product or information on other
REED products, contact REED Instruments at info@reedinstruments.com
www
reedinstruments
www.GlobalTestSupply.com
com
14
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
www
reedinstruments
www.GlobalTestSupply.com
com
15
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
www
reedinstruments
www.GlobalTestSupply.com
com
16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.