Measuring Range(s): Lux: 0 to 50,000
Fc: 0 to 5,000
Accuracy: <10,000 Lux/Fc: ±(5% rdg.+ 10 dgt)
>10,000 Lux/Fc: ±(10% rdg.+ 10 dgt)
Resolution: Lux/Fc: 0.1
Response Time: <1 sec.
Sensor Type: Photo diode & color correction lter
Autoranging: No (Manual)
Display: 4-digit LCD
Data Hold: Yes
Max: Yes
Overrange Indicator: Yes
Sampling Rate: 1.5 times/sec.
Auto Shut-off: Yes (after 15 mins)
Kick Stand: Yes
Low Battery Indicator: Yes
Power Supply: 12V battery
Product Certications: CE
Operating Temperature: 32 to 122°F (0 to 50°C)
Storage Temperature: 14 to 140°F (-10 to 60°C)
Operating Humidity Range: 10-80%
Dimensions: 7.4 x 2.5 x 1” (188 x 64.5 x 24.5mm)
Weight: 5.6 oz (160g)
www
www.GlobalTestSupply. com
reedinstruments
com
3
Pantone 534 BluePantone123Yellow
Pantone 485 RedPantone123Yellow
Pantone 534 Blue
Black
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Panel Description
1- LCD display: 1999 counts LCD display with
LUX, Fc, LOBAT, MAX, HOLD indication
2- Power /Function/Range switch: Turn power ON or OFF
and select measurement function and ranges.
3- Photo Detector: Long life silicon photo diode inside
4- MAX. HOLD: If you press the MAX. button, the maximum reading
will be held. Pressing the button once again, will release the hold and
allow a further measurement.
5- DATA HOLD: The reading will be held when the Data Hold button
Switch is pressed. If the button Switch is pressed once again,
it will release the hold and allow a further measurement.
6- Function button: Selects measurement functions of Lux or Fc
www
www.GlobalTestSupply. com
reedinstruments
com
4
Pantone 534 BluePantone123Yellow
Pantone 485 RedPantone123Yellow
Pantone 534 Blue
Black
Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Operating Instructions
Measuring Light
1. Turn the Power/Function/Range switch to select the range to desired
(x1 Lux/Fc , x10Lux/Fc, x100Lux/Fc) range.
2. Remove the photo detector to the light source in a horizontal position.
3. Read the illuminance nominal from the LCD display.
4. Over-range: If the instrument only displays one “1” in the M.S.D. the
input signal is too strong, and a higher range should be selected.
5. When the measurement is completed, replace the photo detector from
the light source.
6. Spectral sensitivity characteristic: To the detector, the applied photo
diode with lters makes the spectral sensitivity characteristic almost
meet C.I.E. (International Commission on Illumination) photopia curve
Packing work, Entrance passage 150 ~ 300
Visual work at production line 300 ~ 750
Inspection work 750 ~ 1,500
Electronic parts assembly line 1500 ~ 3,000
If the sign “BAT” appears on the LCD display, it indicates that the battery
should be replaced. Open the battery case and replace the expired
battery with new battery. (1 x 12V battery)