REED Instruments R5800-NIST, R5800 User manual

Voltage Current Simulator
R5800
Instruction Manual
www.GlobalTestSupply.com
Table of Contents
Introduction ................................................................................................ 3
Product Quality ........................................................................................... 3
Safety ......................................................................................................... 3
Features ...................................................................................................... 4
Specications .......................................................................................... 4-5
Output Functions ................................................................................... 4
Included ...................................................................................................... 5
Instrument Description ............................................................................... 6
Display Description .................................................................................... 7
Operating Instructions ........................................................................... 8-11
Power ON/OFF ...................................................................................... 8
Automatic Power-Off ............................................................................. 8
Output Function .................................................................................... 8
Output Operation Procedure ................................................................. 9
DC Voltage Output ................................................................................ 9
DC Current Output ................................................................................ 9
25% Step Current Output.................................................................... 10
Current Output Set for Zero Point & Full Scale ................................... 10
Simulating Transmitter Output (XMT) ................................................... 11
Battery Replacement ........................................................................... 11-12
Fuse Replacement ................................................................................... 12
Accessories and Replacement Parts ....................................................... 13
Product Care ............................................................................................ 13
Product Warranty ..................................................................................... 13
Product Disposal and Recycling .............................................................. 14
Product Support ....................................................................................... 14
www.GlobalTestSupply.com
Introduction
Thank you for purchasing your REED R5800 Voltage/Current Simulator. Please read the following instructions carefully before using your instrument. By following the steps outlined in this manual your meter will provide years of reliable service.
Product Quality
This product has been manufactured to meet stated product specications. If a certicate of calibration is required please contact the nearest authorized REED distributor or authorized Service Center. Please note an additional fee for this service will apply.
Safety
To prevent the user and the instrument from electric shock and other hazards, it is necessary to follow the following regulations:
• Never attempt to repair or modify your instrument. Dismantling your product, other than for the purpose of replacing batteries, may cause damage that will not be covered under the manufacturer's warranty. Servicing should only be provided by an authorized service center.
Do not operate the instrument in the presence of ammable or explosive gas or vapor. This is extremely dangerous.
• Never apply more than 30V between any two terminals, or between terminal and ground.
• For optimal accuracy, allow the instrument to warm up for 5 minutes before operating.
www.GlobalTestSupply.com
Features
• Sources voltage and current
• Large, 5-digit LCD display
• Automatic calibration
• Low battery indicator and auto shut off
Specifications
Output Functions
Applicable range from 18 to 28°C, within one year of calibration.
Output Range
DCV 10V
Output
Range
0.000 to
11.000V
Resolution Accuracy Note
1mV
0.05% of set value ±2mV
current: 2mA
Max output
DCA 20mA
Analog
transducer
Loop
power
0.000 to
22.000mA
-20mA
24V - - ±10%
0.000 to
-22.000mA
0.001mA
0.001mA
0.05% of set
value ±4μA
0.05% of set
value ±4μA
Max load:
1kΩ at 20mA
note 1
Max load:
1kΩ at 20mA
Max output
current up
to 25mA
Note 1: When the battery voltage exceeds 6.8V, the max load is 1KΩ at 20mA. When its voltage lies between 5.8V and 6.8V, the max load is 700Ω at 20mA.
Note 2: Temperature coefcient: ±0.005% of the range per °C for the temperature ranges 5 to 18°C and 28 to 40°C.
continued...
www.GlobalTestSupply.com
General Specifications
Display: 5-Digit LCD Kick Stand: Yes Battery Life: Approximately 20 hours Power Supply: 2 AA Batteries Auto Shut Off: Yes (after 15 minutes/off) Low Battery Indicator: Yes Replaceable Test Leads: Yes Product Certications: CE Operating Temperature: 32 to 122°F (0 to 50°C) Operating Humidity Range: 0 to 85% Storage Temperature: 14 to 122°F (-10 to 50°C) Dimensions: 7.1 x 3.5 x 1.9" (180 x 90 x 47mm) Weight: 8.2oz (500g)
Included
• Test Leads
• Alligator Clips
• Protective Holster
• Batteries
www.GlobalTestSupply.com
Instrument Description
R5800
3
4 5
6
Voltage/Current Simulator
7
8 9
10
1. LCD Screen
2. Unit V/mA Select Button
3. Power Button
4. Output ON/OFF Button
5. Output Value Setting Button
6. Output Digit Selection Button
www.GlobalTestSupply.com
7. Unit mA/% Select Button
8. Zero/FS Points Select Button
9. 25% Single Step Setting/Auto Ramp Button
10. Output Terminals
Display Description
Indicates that the instrument is in an output state Indicates that the instrument is in a calibration state Indicates that the instrument is in a calibration state, denoting
that the zero point or the full scale point is now in calibration Indicates that the battery power is low and needs to
be replaced Indicates that the output digits need to be set
V. mA. % Indicates the current output value (unit of measure)
Indicates that the output signal is on or off
www.GlobalTestSupply.com
Operating Instructions
Power ON/OFF
Press the POWER button to turn the instrument on. To turn the instrument off, press and hold the POWER button.
Automatic Power-Off
As a default the instrument will automatically turn off after 15 minutes of inactivity. Follow the steps below to Enable/Disable the Auto-Power Off function.
1. Turn the meter off.
2. Press the ON/OFF button (to display the full screen).
3. Quickly press the mA% button when the instrument is in the mainte­nance state as indicated by "1.8.8.888".
4. "AP-XX" will appear on the display.
5. Press the indicates that the automatic power-off function is disabled, while "AP-ON" indicates the automatic power-off function is enabled.
6. Press the mA 100% button to save the required setting.
7. Press and hold the ON/OFF button to exit the maintenance state and turn the instrument off.
Output Function
The output terminal of the instrument can produce DC voltages set by the user or simulating resistance.
Do not apply any voltage to the output terminal during the operation. If any improper voltage is applied to the output terminal, it will cause damage to the internal circuits.
button to toggle between "AP-ON" & "AP-OF". "AP-OF"
www.GlobalTestSupply.com
continued...
Output Operation Procedure
XMT
V
30V
MAX MAX
30V
30V
MAX
+mA-
XMT
V
30V
MAX
MAX 30V
30V
MAX
+mA-
Function
Operation
DCA 10mA 20mA% 0.000V
Range
Operation
Display Set Range
0.000 to 11.000V
-00.000 to 22.000mA
DC Voltage Output
1. Insert one end of the test leads into the V output jack and connect the other end to the input of the meter, as shown in the diagram.
2. Press the V/mA button to select V function and V will appear on the display.
3. Press the buttons to select the output digits.
4. Press the buttons to change the numerical value of the set digits. Hold the button and the value will keep varying.
5. Press the ON/OFF button to turn the output signal on and off as indicated by ON or OFF on the LCD display.
DC Current Output
1. Insert one end of the test leads into the +mA output jack and connect the other end to the input of the meter, as shown in the diagram.
2. Press the V/mA button to select mA function and mA will appear on the display.
3. Press the mA/% button to select mA or % function to display the mA or % unit, in which 0% is 4mA and 100% is 20mA.
4. Press the buttons to select the output digits.
5. Press the buttons to change the numerical value of the set digits. Hold the button and the value will keep varying.
6. Press the ON/OFF button to turn the output signal on and off as indicated by ON or OFF on the LCD display.
www.GlobalTestSupply.com
continued...
25% Step Current Output
1. Connect the test leads to the meter as stated in the Current Output procedures.
2. Press the V/mA button to select mA function and mA will appear on the display.
3. Press the mA 25% button and
4. Press the mA/% button to select the set output mA or % and mA or mA% will appear on the display.
5. Press the button to change the output value in 25% increments in which 0% indicates 4mA and 100% indicates 20mA
6. Press the ON/OFF button to turn the output signal on and off as indicated by ON or OFF on the LCD display.
7. Press the mA 25% button to exit the 25% current output setup.
will appear on the display.
,
.
Current Output Set for Zero Point & Full Scale
1. Connect the test leads to the meter as stated in the Current Output procedures.
2. Press the V/mA button to select the mA function and mA will appear on the display
3. Press the mA 100% button.
4. Press the mA/% button to select the set output mA or % and mA or mA% will appear on the LCD display.
5. Press the buttons to change the output values at 100%, in which 0% indicates 4mA and 100% indicates 20mA.
6. Press the ON/OFF button turn the output signal on and off as indicated by ON or OFF on the display.
7.
Press the mA 100% button to exit the full scale current output set up.
, 0 and FS will appear on the display.
www.GlobalTestSupply.com
continued...
10
Simulating Transmitter Output (XMT)
1. Insert one end of the test lead to the 'XMT' output jack of the calibrator and connect the other end with the input terminal of the user's instrument as shown in the following diagram:
XMT
+mA-
V
5--25VDC POWER
MAX MAX 30V
MAX 30V
30V
2. The button-operation is the same as that as indicated in the Current Output section.
Note:
Power supply range: 5 to 25V DC.
During an output operation, use a external 24V DC power supply in
order to prolong battery life.
Battery Replacement
When the appears on the LCD, the batteries need to be replaced. Follow the instructions below to properly replace the batteries.
1. Turn the power off the meter and remove any test leads that may be attached to the meter.
2. Lift the tilt stand on the back of the unit to access the battery compartment door, which can be removed using a Phillips head screwdriver.
3. Replace the 2 x "AA" batteries in the lid of the battery compartment.
continued...
11
www.GlobalTestSupply.com
4. Reinstall the compartment lid by ensuring that battery terminals touch the unit's contact points and snap into place.
5. Tighten the screw to secure the battery compartment door.
Ensure battery door is closed and secure in place before
using the meter. To ensure proper operation, wait 5 seconds
before turning meter on after changing batteries.
Fuse Replacement
Figure 1
1. Remove the test leads from the meter and turn the meter OFF.
2. Take off the protective boot (Figure 1), remove the four screws by using a standard-blade screwdriver, and then remove the cover (Figure 2).
3. Replace the blown fuse(s).
4. Reinstall the cover.
5. Reinstall the meter's protective boot.
Figure 2
12
www.GlobalTestSupply.com
Accessories and Replacement Parts
FC-300 Fused Test Lead Set
R1000 Safety Test Lead Set, Double Insulated
CA-05A Soft Carrying Case
R9940 Hard Shell Carrying Case
Don't see your part listed here? For a complete list of all accessories and replacement parts visit your product page on www.reedinstruments.com.
Product Care
To keep your instrument in good working order we recommend the following:
• Store your product in a clean, dry place.
• Change the battery as needed.
• If your instrument isn't being used for a period of one month or longer
please remove the battery.
• Clean your product and accessories with biodegradable cleaner. Do not
spray the cleaner directly on the instrument. Use on external parts only.
Product Warranty
REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance. REED Instruments total liability is limited to repair or replacement of the product. REED Instruments shall not be liable for damages to goods, property, or persons due to improper use or through attempts to utilize the instrument under conditions which exceed the designed capabilities. In order to begin the warranty service process, please contact us by phone at 1-877-849-2127 or by email at info@reedinstruments.com to discuss the claim and determine the appropriate steps to process the warranty.
www.GlobalTestSupply.com
13
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your instrument. Your product contains electronic components and must be disposed of separately from standard waste products.
Product Support
If you have any questions on your product, please contact your authorized REED distributor or REED Instruments Customer Service by phone at 1-877-849-2127 or by email at info@reedinstruments.com.
Please visit www.REEDINSTRUMENTS.com for the most
up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice. All rights reserved. Any unauthorized copying or reproduction of this manual is strictly prohibited without prior written permission from REED Instruments.
www.GlobalTestSupply.com
14
TEST & MEASURE
WITH CONFIDENCE
CHECK OUT OUR LATEST PRODUCTS!
www.GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...